產品通報 Newsletter 1/53 Purpose: Release information about the application software DOPSoft 2.00.06 for DOP series products. Latest firmware for the DOP-B series: 3.0096 Latest firmware for the DOP-W series: 3.0083 Latest OS for the DOP-W series: 1.028 Latest firmware for the HMC: 3.0179 Latest DSP for the HMC: 1.0029 Description: Applicable models: DOP-B / DOP-W / DOP-H / HMC series 1. Software / firmware revisions: 1.1 Fix the DOP-B series HMI crash occurring when you enter the system menu and return to general screens if IP conflict occurs. 1.2 Fix the DOP-B series HMI crash occurring when it reads from or writes to devices with allocation unit size over 4K. 1.3 Fix the issue of exporting older history data in non-volatile memory in HMI. 1.4 Fix the DOP-B series HMI crash occurring when you insert an external device and set to save the non-volatile data in the external device. 1.5 Fix the communication setting error occurring when cycling the power to DOP-B07S410 HMIs. 1.6 Fix the continuous error of auto-detection window when the communication setting between DOP- B07S410 HMI and Delta ASDA-A2 is correct. 1.7 Fix the communication error between DOP-W series HMIs and the controller using Modbus TCP/IP when the communication is lost for 16 times or more. Technical Announcement Issued by IMSBU HMI Author(s) Daisy, Huang Security Classification General Confidential Issue No. HMI17070700 Released Date July 07, 2017 Recipient Product Manager, BU Sales Representative, Global Service Partners

Upload: dominh

Post on 26-May-2018

221 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

1/53

Purpose:

Release information about the application software DOPSoft 2.00.06 for DOP series products.

Latest firmware for the DOP-B series: 3.0096

Latest firmware for the DOP-W series: 3.0083 Latest OS for the DOP-W series: 1.028 Latest firmware for the HMC: 3.0179

Latest DSP for the HMC: 1.0029 Description:

Applicable models: DOP-B / DOP-W / DOP-H / HMC series

1. Software / firmware revisions:

1.1 Fix the DOP-B series HMI crash occurring when you enter the system menu and

return to general screens if IP conflict occurs.

1.2 Fix the DOP-B series HMI crash occurring when it reads from or writes to devices with

allocation unit size over 4K.

1.3 Fix the issue of exporting older history data in non-volatile memory in HMI.

1.4 Fix the DOP-B series HMI crash occurring when you insert an external device and set

to save the non-volatile data in the external device.

1.5 Fix the communication setting error occurring when cycling the power to

DOP-B07S410 HMIs.

1.6 Fix the continuous error of auto-detection window when the communication setting

between DOP- B07S410 HMI and Delta ASDA-A2 is correct.

1.7 Fix the communication error between DOP-W series HMIs and the controller using

Modbus TCP/IP when the communication is lost for 16 times or more.

Technical Announcement

Issued by IMSBU

HMI Author(s) Daisy, Huang

Security

Classification

General

Confidential

Issue No. HMI17070700 Released

Date July 07, 2017

Recipient Product Manager, BU Sales Representative, Global Service Partners

Page 2: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

2/53

1.8 Fix the copying failure occurring when the DOP-W series HMI screen data file contains

alarm data.

1.9 Fix the execution error of the momentary button with user security level settings for

DOP-W series HMIs.

1.10 Fix the execution error of the control section occurring when the DOP-W series HMI

enables the communication optimization function.

1.11 Fix the DOP-W series HMIs with no response for a short time when you trigger the bit

for saving as multiple files in history buffer.

1.12 Fix the DOP-W series HMIs with alarm clearance error when the number of alarms

exceeds the savable range in the history buffer.

1.13 Fix the screen download failure when DOPSoft is in Windows 10 environment.

1.14 Fix the DOPSoft crash issue when exporting multi-language texts in Windows 10.

1.15 Fix the calculation error (repeat calculation) when you compile projects in DOPSoft.

1.16 When HMI connects with eRemote, fix the HMI crash occurring if you go to the system

menu and return to general screens.

1.17 Fix the connection error between eRemote and the HMI when GridBox element is set

with an After Execute macro.

1.18 Fix the HMI with no response due to users' not removing the external device safely

before re-plugging in the device.

1.19 Fix the HMI crash occurring when it reads from or writes in NTFS-formatted storage

devices.

1.20 Fix the reading error occurring when the enhance recipe imported to the HMI is edited

with Excel.

1.21 Fix the HMI crash occurring if you plug in the external device to auto import the recipe

when HMI screen shows the message that the USB Disk does not exist.

1.22 Fix the HMI crashing error occurring when the alarm message contains more than 56

characters.

1.23 Fix the alarm number recording error that occurs when you set to save the non-volatile

data (alarm history) in the HMI.

1.24 Fix the issue of being unable to open the file by computer while you use “Save as

Multiple Files” function in the history buffer.

1.25 Fix the result error occurring when you use Modbus to access 16-bit recipe values.

1.26 Fix the reconnection error occurring when communication failure occurs for over 16

times between the HMIs and some network type PLCs.

Page 3: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

3/53

1.27 Fix the issue that the HMI keeps showing the alarm window when booting if the HMI

cannot automatically obtain the IP address.

1.28 Fix the HMI crash occurring when HMI updates the RTC (real-time clock) through

PLC.

1.29 Fix the HMI crash occurring when the barcode reader connecting to the HMI is

interfered.

1.30 Change the controller name Omron CJ2M TCP to CJ/NJ Series FINS TCP.

2. New functions of the software / firmware:

2.1 Add the FTP Client function.

2.2 Add operation log for DOP-W series HMIs.

2.3 Add the sorting function to the Alarm Frequency Table for DOP-B series HMIs.

2.4 Add internal system parameter KEY_CHAR for DOP-B and DOP-H series HMIs to

capture the keyboard input characters.

2.5 Add the ascending/descending sorting function in alarm history list for DOP-W series

HMIs.

2.6 Screen display becomes faster when DOP-W series HMIs connect to PLCs.

2.7 Add network type PLC information when you obtain the firmware version in DOPSoft.

2.8 Add the supporting MC protocol for FX3U Ethernet controllers.

2.9 Add the function for re-obtaining the Ethernet address (DHCP) during screen

operation.

2.10 Add a new macro EXALARMGROUP that exports the alarms based on groups for

DOP-B series HMIs.

2.11 Add the USB host waiting time setting in the [System Menu] for DOP-B series HMIs.

2.12 More controllers (listed below) can now connect with the Delta HMI.

Delta 15MC

Delta 15MC TCP Delta 10EMC TCP Delta CNC Controller ASCII

Fatek FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U

Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port Moeller EasyPLC 800/MFD

Siemens S7 1500 (ISO TCP)

Page 4: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

4/53

2.13 New models: B07SS411

3. Website to download the software:

http://www.deltaww.com/services/DownloadCenter2.aspx?secID=8&pid=2&tid=0&CID=06&ite

mID=060302&typeID=1&downloadID=DOP-B,&title=DOP-B&dataType=8;&check=1&hl=zh-TW

Page 5: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

5/53

1. Software / Firmware revisions

1.1. Fix the DOP-B series HMI crash occurring when you enter the system menu and return to

general screens if IP conflict occurs.

Before

If the DOP-B series HMI detects a device using an identical IP address, the IP

conflict alarm occurs. Then, when you enter the system menu, the HMI crashes.

After When the HMI detects a device using the same IP address and the IP conflict

alarm pops up, you can still go to the system menu.

1.2. Fix the DOP-B series HMI crash occurring when it reads from or writes to devices with

allocation unit size over 4K.

Before When the DOP-B series HMI continues to read from or write to devices with

allocation unit size over 4096 bytes, the HMI crashes.

After

When the DOP-B series HMI detects a device with allocation unit size over 4096

bytes, it prompts an alarm message and a reminder for formatting the memory

device by HMI. See the example below.

Page 6: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

6/53

Step 1: when plugging in the USB Disk which allocation size is over 4096 bytes, a

message showing “Allocation unit size is over 4k.” pops up. (If you are using the

previous DOPSoft version (not 2.00.06), the HMI displays “Error Cluster over 4K

size”.)

Step 2: press OK and the HMI prompts a window to ask whether to format the

storage device. Please press YES.

Step 3: press YES to start formatting the device. It takes some time, so please wait

and do not remove the storage device or switch off the HMI.

Step 4: if you press NO in Step 2 (not to format the device), then the storage

device is unavailable and the HMI prompts you that the device is not supported.

Page 7: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

7/53

Step 5: after the initialization, a message “Please re-insert the device” displays.

Please press OK and re-plug in the device to start using the storage memory.

If you use Windows system to format the storage device instead of the HMI, select

the allocation size below 4096 bytes.

Page 8: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

8/53

1.3. Fix the issue of exporting older history data in non-volatile memory in HMI.

Before

If you keep the history buffer in non-volatile memory in the DOP-B series HMI, the

exported history data might contain old data as well as new data as shown in the

figure below.

After In the DOP-B series HMI, the history data exported from non-volatile memory is

correct and sorted by date and time.

1.4. Fix the DOP-B series HMI crash occurring when you insert an external device and set to

save the non-volatile data in the external device.

Before

To import the recipe file automatically, you must set the non-volatile data (recipe)

location to an external storage device first before exporting to the device. When

the storage device is plug into the HMI, the recipe file is automatically imported.

Old data

Page 9: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

9/53

If you used Excel to edit the recipe file, then the HMI crashes when it is imported to

the HMI.

After

In DOP-B series HMIs, if you set to save the non-volatile data (recipe) in an

external device before exporting the recipe to the device, you can use Excel to edit

the recipe. When you plug in the external device to the HMI, the edited recipe is

automatically imported to the HMI.

Page 10: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

10/53

1.5. Fix the communication setting error occurring when cycling the power to DOP-B07S410

HMIs.

Before

When connecting a DOP-B07S410 HMI with a Delta device, you can use

auto-detection to complete the communication setting if communication is off.

However, when you cycle the power to the HMI, the communication setting is in

error.

After

When connecting a DOP-B07S410 HMI with a Delta device, you can use

auto-detection to complete the communication setting. When you cycle the power

to the HMI, the previous communication setting remains and you can use

auto-detection to complete the communication setting.

1.6. Fix the continuous error of auto-detection window when the communication setting

between DOP- B07S410 HMI and Delta ASDA-A2 is correct.

Before

If you use DOP-B07S410 HMIs with Delta ASDA-A2 servo drives, when power-on,

the detection window pops up even when communication setting is correct.

After

When connecting DOP-B07S410 HMIs and Delta ASDA-A2 servo drives with

RS-485, no detection window displays during power-on if the communication

setting is correct. If incorrect, the detection window displays when power-on and it

can detect the communication setting for A2 servo drives. If you use RS-232 for

communication between DOP-B07S410 and ASDA-A2 and the communication

setting is correct, the detection window displays when power-on.

Page 11: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

11/53

1.7. Fix the communication error between DOP-W series HMIs and the controller using Modbus

TCP/IP when the communication is lost for 16 times or more.

Before

When the DOP-W series HMI and controller use Modbus TCP/IP for connection, if

the connection between the controller and HMI is lost for 16 times or more, then

the controller cannot connect to the HMI successfully anymore.

After

When the DOP-W series HMI and controller use Modbus TCP/IP for connection, if

the connection between the controller and HMI is lost, you can always connect

them again.

1.8. Fix the copying failure occurring when the DOP-W series HMI screen data file contains

alarm data.

Before

When there are more than two DOP-W series HMIs, if HMI A has the alarm data saved, go to [System Menu] > [System Setting] > [File Manager] > [Copy File] to copy the screens to an external storage device, then copy this screen data file to

HMIB, a message “Copy fail” shows on HMI B and HMI B is restored to the

default.

After When there are more than two DOP-W series HMIs, whether HMI A has the alarm

data or not, the screen data file can be successfully copied to HMI B.

1.9. Fix the execution error of the momentary button with user security level settings for DOP-W

series HMIs.

Before

If you use a momentary button with user security level settings in DOP-W series

HMI, after entering the password, the momentary button remains in ON state and

does not switch to OFF. See the example below:

Step 1: create a momentary button on the screen. Go to [Details] and set the [User

Security Level] to 6.

Page 12: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

12/53

Step 2: for this momentary button, set $1 = 1 for the ON macro and $2 = 1 for the

Off macro. Then, set two numeric entry elements which memory addresses are $1

and $2 to see whether the ON macro and OFF macro for the momentary button

are executed.

Step 3: download the project to the DOP-W HMI, when the user security level is

not high enough, execute the momentary button and enter the password.

Page 13: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

13/53

Step 4: after you enter the password, please press OK and then the momentary

button stays in ON state without the OFF macro being executed.

After

When you execute a momentary button with user security level settings in DOP-W

series HMI, after entering the password, the momentary button is ON and then

goes OFF, which means both ON macro and OFF macro are executed.

ON state OFF macro not executed

Page 14: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

14/53

1.10. Fix the execution error of the control section occurring when the DOP-W series HMI

enables the communication optimization function.

Before

When you enable the communication optimization function for the project in

DOP-W series HMI and use PLC address for the control, the execution result in

the control section is in error (unable to switch screens).

Page 15: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

15/53

After

When you enable the communication optimization function for the project in

DOP-W series HMI and use PLC address for the control, the execution result in

the control section is correct.

Control with PLC address

Page 16: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

16/53

1.11. Fix the DOP-W series HMIs with no response for a short time when you trigger the bit for

saving as multiple files in history buffer.

Before

In the DOP-W series HMIs, after you trigger the “Save as Multiple Files” bit for the

history buffer and execute the elements for screen change or numeric entry, there

is no response from the HMI lasting 10 – 20 seconds.

After After you trigger the “Save as Multiple Files” bit for the history buffer, there is no

problem with executing elements for switching screens or inputting values.

Step 1 Step 2

Page 17: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

17/53

1.12. Fix the DOP-W series HMIs with alarm clearance error when the number of alarms

exceeds the savable range in the history buffer.

Before

In DOP-W series HMIs, when the number of alarms exceeds the savable number,

you cannot clear the alarms by clearing the buffer. The alarms to be cleared are

still in the active alarm list. See the example below:

Step 1: set the maximum savable alarms (Max Records) to 5.

Step 2: trigger Alarm 1 – 5.

Page 18: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

18/53

Step 3: trigger Alarm 6 and the total alarms are 6, which exceeds the maximum. In

the alarm history, you can see that Alarm 6 overwrites Alarm 1.

Step 4: clear the alarms in the buffer.

Page 19: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

19/53

Step 5: clear Alarm 1. It cannot be cleared. The list still shows Alarm 1.

Page 20: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

20/53

After

In DOP-W series HMIs, when the number of alarms exceeds the maximum

savable number, after you clear the history buffer, the list does not display the

alarms that are cleared.

1.13. Fix the screen download failure when DOPSoft is in Windows 10 environment.

Before You cannot download screens when DOPSoft is in Windows 10 environment.

After You can download screens when DOPSoft is in Windows 10 environment.

1.14. Fix the DOPSoft crash issue when exporting multi-language texts in Windows 10.

Before

When using DOPSoft in Windows 10, you export the multi-language texts by going

to [Edit] > [Export Multi-language Text], but DOPSoft crashes and shows the

Exception window.

After When using DOPSoft in Windows 10, you can export the multi-language texts by

going to [Edit] > [Export Multi-language Text] without error.

Alarm 1 is not cleared

Page 21: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

21/53

1.15. Fix the calculation error (repeat calculation) when you compile projects in DOPSoft.

Before

If you compile the project in DOPSoft, the memory calculates repeatedly and so an

error message “Memory is not enough to open (page name)” displays when there

is still memory available.

After The compiling results are correct and DOPSoft correctly calculates the available

memory.

1.16. When HMI connects with eRemote, fix the HMI crash occurring if you go to the system

menu and return to general screens.

Before

In the HMI project, if you set the [System Error Display Time] to 0 by going to

[Configuration] > [Default] and enable the offline alarm window in [Configuration] >

[Network Application], the HMI crashes if you go to the system menu and return to

the HMI screen by using eRemote to connect the HMI.

Page 22: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

22/53

After When you use eRemote to connect the HMI and then go to the system menu and

return to the HMI screen, you can continue to control the HMI with eRemote.

1.17. Fix the connection error between eRemote and the HMI when GridBox element is set

with an After Execute macro.

Before

If the GridBox element on the screen is set with the After Execute macro, the

eRemote cannot connect with the HMI and the message "Parsing…." stays on the

screen.

Page 23: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

23/53

After eRemote can connect with the HMI and you can use the GridBox element without

error.

1.18. Fix the HMI with no response due to users' not removing the external device safely

before re-plugging in the device.

Before

When you set to save the history buffer in an external storage device and you

directly remove the external storage device without executing “Remove Storage”

button, the file written in the external device may be in error. If you remove the

power from the HMI, re-plug in the external device, and cycle the power, the HMI

stays at the reading screen.

After

If you directly remove the external storage device without executing the “Remove

Storage” button, the file written in the external device is in error. Meanwhile, if you

remove the power from the HMI, re-plug in the external device, and cycle the

power, the HMI shows the general screen, ignoring the previous error and reading

the content that is correctly written in the history buffer.

1.19. Fix the HMI crash occurring when it reads from or writes in NTFS-formatted storage

devices.

Before The HMI currently only supports storage devices in FAT32 format. If the HMI reads

from or writes in NTFS-formatted devices, it crashes.

Page 24: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

24/53

After

If the HMI reads from or writes in NTFS-formatted storage devices, the HMI

prompts a message showing the device is not supported.

Go to [System menu] > [System Setting] > [File Manager] > [Format Removable

Disk] to format the device. Or, you can format the device and convert it to FAT32

format by Windows.

Page 25: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

25/53

1.20. Fix the reading error occurring when the enhance recipe imported to the HMI is edited

with Excel.

Before If you use Excel to edit the recipe, after you import this recipe to the HMI, the HMI

shows the CSV file reading error message.

After You can use Excel to edit the recipe file and no error occurs when you import this

recipe to the HMI.

1.21. Fix the HMI crash occurring if you plug in the external device to auto import the recipe

when HMI screen shows the message that the USB Disk does not exist.

Before

To automatically import the recipe file, you must set to save the non-volatile data

(recipe) to an external device. Then, export the recipe so that the external device

has the recipe file saved. After the external device connects to the HMI, the recipe

is imported automatically.

However, if the HMI prompts you that the USB Disk does not exist and you plug in

the external device, the HMI crashes when importing the recipe.

Page 26: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

26/53

After

If you set to save the non-volatile data (recipe) in the external device, when the

HMI prompts you that the USB Disk does not exist and you plug in the external

device, the HMI automatically imports the recipe file.

1.22. Fix the HMI crashing error occurring when the alarm message contains more than 56

characters.

Before

If the non-volatile data is set to be saved in the external device and the alarm

message contains over 56 characters, the HMI crashes when the alarm is

triggered.

Page 27: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

27/53

After The HMI alarm message can contain up to 61 characters. The HMI displays the

message properly and you can also export the CSV file to an external device.

1.23. Fix the alarm number recording error that occurs when you set to save the non-volatile

data (alarm history) in the HMI.

Before

When you set to save the non-volatile memory for the alarm history in the HMI and

the number of alarm occurrences is over 255, the number showing on the alarm

frequency list is incorrect. If the alarm occurrence time is 255, the HMI displays

255; but if it is 256, it shows 0.

After The HMI can correctly display the number of alarm occurrences when you set to

save the non-volatile data for alarm history in the HMI.

56 characters

Page 28: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

28/53

1.24. Fix the issue of being unable to open the file by computer while you use “Save as

Multiple Files” function in the history buffer.

Before

If you use the “Save as Multiple Files” function in the history buffer, after the buffer

accumulates some files, you cannot open these files by the computer and the

computer shows file access failure.

After If you use the “Save as Multiple Files” function in the history buffer, you can access

all files through the computer.

1.25. Fix the result error occurring when you use Modbus to access 16-bit recipe values.

Before

When two HMIs communicate through Modbus, HMI B reads the 16-bit recipe

values from or writes the 16-bit recipe values to HMI A by Modbus TCP/IP. If HMI

A’s recipe group number (RCPNO) changes to a non-first group recipe, the recipe

value read by HMI B is incorrect.

After

If two HMIs communicate through Modbus, the reading result is correct when HMI

B reads the 16-bit recipe values from or writes the 16-bit recipe values to HMI A by

Modbus TCP/IP.

1.26. Fix the reconnection error occurring when communication failure occurs for over 16 times

between the HMIs and some network type PLCs.

Before

When the HMI connects to the following network type PLCs and communication

failure occurs over 16 times, the HMI cannot connect to the PLC again unless you

reboot the HMI.

PLCs with connectivity issues to the HMI:

Manufacturer Series

Delta Delta RTU-EN01 (Ethernet)

Modbus TCP/IP (6 Digitals)

FUJI Electronic MICREX SX Series TCP

XINJE XINJE XC series PLC (Modbus TCP)

Yaskawa SIO UDP

Page 29: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

29/53

After The HMIs and PLCs can always re-connect after communication failures occur.

1.27. Fix the issue that the HMI keeps showing the alarm window when booting if the HMI

cannot automatically obtain the IP address.

Before

If you set the HMI to automatically obtain the IP address when booting, but the HMI

fails to get the IP address due to problems such as loose connection cable or

DHCP Server error, the screen shows “DHCP can’t be started!!”. Then, you have

to press OK to enter the screen.

After

When the HMI cannot automatically obtain the IP address and shows the alarm

message, you can go to the HMI screen without pressing OK.

After the HMI boots, if you need to obtain the IP address, use bit 10 in the control

block to get the IP address. For more information, please refer to 3.9 Function for

re-obtaining the Ethernet address during screen operation (DHCP) in this

document.

Page 30: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

30/53

Page 31: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

31/53

1.28. Fix the HMI crash occurring when HMI updates the RTC (real-time clock) through PLC.

Before

When the HMI enables the RTC (real-time clock) and you update the RTC through

PLC, the HMI crashes after some communication time.

After The HMI can update the RTC through PLC. You can update the HMI time to the

PLC or update PLC time to the HMI.

1.29. Fix the HMI crash occurring when the barcode reader connecting to the HMI is interfered.

Before If the barcode reader connecting to the HMI is being interfered for a while, the HMI

crashes.

Page 32: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

32/53

After If the barcode reader connecting to the HMI is being interfered, the HMI does not

crash and you can continue to use the barcode reader.

1.30. Change the controller name Omron CJ2M TCP to CJ/NJ Series FINS TCP.

Before

In the HMI project, you can set the controller Omron CJ2M TCP to connect Omron

CJ and Omron NJ series network type PLC, but these names are confusing.

After Now the controller name is changed to Omron CJ/NJ series FINS TCP which can

Page 33: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

33/53

connect Omron CJ and Omron NJ series network type PLC. In DOPSoft 2.00.06,

when you open the project file created by DOPSoft 2.00.05 or earlier versions, the

controller changes to Omron CJ/NJ Series FINS TCP.

2. Software / Firmware new functions

2.1. Add the FTP Client function.

For details about the FTP setting, please refer to the technical announcement for FTP Client.

2.2. Add operation log for DOP-W series HMIs.

For more information, please refer to the technical announcement for the operation log.

2.3. Add the sorting function to the Alarm Frequency Table for DOP-B series HMIs.

The Alarm Frequency Table of DOP-B series HMIs sorts based on “alarm number”, and now it

can also sort by “number of alarm occurrences” and you can use the variable to trigger this

new sorting function.

Page 34: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

34/53

You can enable the sorting function in the property list as well as by triggering the variable

using the memory address. When you set the value to 1, the sorting function is enabled and

the list sorts by number of alarm occurrences. When you set to 0, the sorting function is

disabled and the list sorts by alarm number.

Variable

Type

Internal

memory

PLC

register Constant

Sorting trigger bit ◎ ◎

Page 35: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

35/53

See the example below. The figure on the left shows the list with the sorting function

enabled. The list sorts the number of alarm occurrences in descending order. The figure on

the right shows the list sorting the alarm number in ascending order.

2.4. Add internal system parameter KEY_CHAR for DOP-B and DOP-H series HMIs to capture

the keyboard input characters.

The HMIs provide internal system parameter KEY_CHAR to capture the characters input by

external keyboard and enables you to see whether the conditions are met for the macro.

Number of the alarm occurrences

sorting in descending order

Alarm number sorting in

ascending order

Page 36: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

36/53

Please refer to the example below:

Step 1: create a character entry element in the project and set the write address to

KEY_CHAR.

Step 2: download the project to the HMI and connect the keyboard using the USB connector.

Page 37: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

37/53

Step 3: enter the text to display on the character entry element in the project by keyboard.

Enter character “A”, the character entry element displays “A”.

2.5. Add the ascending/descending sorting function in alarm history list for DOP-W series HMIs.

The Alarm History Table in the DOP-W series HMI can sort the display order using the control

address based on options such as triggering time and alarm counts. Before the revision, the

table can only sort in ascending order. Now the control address for ascending and descending

sorting is added to the HMI. Setting 0 means ascending sorting while setting 1 means

descending sorting. If you do not set this sorting control address, the Alarm History Table sorts

in ascending order (default).

See the following example.

Step 1: please set the sorting order control address. $3006 is used in the example below.

Page 38: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

38/53

Step 2: create a numeric entry element and set the write memory address to the

ascending/descending sorting control address. Take $3006 as a setting example.

Page 39: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

39/53

Step 3: download and execute the project after the alarm occurs. Select “Sorting by Alarm

Number” and set $3006 to 1 to sort in descending order.

Page 40: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

40/53

Step 4: set $3006 to 0, the list sorts in ascending order.

Alarm number sorts in

descending order

Page 41: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

41/53

2.6. Screen display becomes faster when DOP-W series HMIs connect to PLCs.

Before the revision, when DOP-W series HMIs connect to PLCs, the communication element

updates only after a communication cycle finishes. Now, the elements update their statuses

right after you trigger the button or update values. The HMI display becomes smoother with very

little display lag.

2.7. Add network type PLC information when you obtain the firmware version in DOPSoft.

Before the revision, when you obtain the firmware version by going to [Tools] > [Get Firmware

Information], DOPSoft only shows information about PLCs that connect through COM ports.

Now, DOPSoft shows the information about PLCs connecting through COM ports and Ethernet.

As shown in the figure below, Driver 4 shows the settings for all network type PLCs. This

example uses two network-type PLCs, one is Modbus TCP/IP which is displayed as

MODTCPIP and its version is VER1.7; the other is Delta DVP TCP/IP which is displayed as

Alarm number sorts in

ascending order

Page 42: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

42/53

DELDVPTCP and the version is 2.4. Contents in the square brackets represent the connection

number using this controller. In the example below, 0 means connection No. 0 uses Modbus

TCP/IP, and connection No. 1 and No.2 use Delta DVP TCP/IP.

2.8. Add the supporting MC protocol for FX3U Ethernet controllers.

The PLC Mitsubishi FX3U Ethernet uses MELSOFT protocol for communication. When using

the MELSOFT protocol, the port has to be 5556 so that the HMI can connect with Mitsubishi

FX3U network type PLC.

Now, MC protocol is provided for communication between HMIs and Mitsubishi FX3U network

type PLCs. The MC protocol can work with the PLC software based on the user-defined

communication port.

Page 43: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

43/53

2.9. Add the function for re-obtaining the Ethernet address (DHCP) during screen operation.

In the past, if the HMI is set to automatically obtain the IP address, the HMI can only obtain the

IP address when booting. Now, you can set a control bit so that the HMI can automatically get

the IP address during screen operation. See the example below.

Step1: go to [Options] > [Configuration] > [Control Block] and check [Recipe Control].

Page 44: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

44/53

Step 2: create a button to trigger the bit for “Enable DHCP again” on the screen. For this

example, please create a button with the write address as $7.10.

Step 3: create the elements for displaying the IP address, SUBMASK address, and Gateway

address on the screen.

Page 45: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

45/53

Step 4: download the screen to the HMI. Do not connect the DHCP server when the HMI boots.

The HMI displays an alarm message “DHCP can’t be started!” while booting, meaning it cannot

obtain the IP address. Meanwhile, the IP address, SUBMASK address, and Gateway address

are all 0.

Page 46: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

46/53

Step 5: connect the HMI with DHCP server and then press the button for “Enable DHCP again”

so the HMI can obtain the IP address immediately.

2.10. Add a new macro EXALARMGROUP that exports the alarms based on groups for

DOP-B series HMIs.

You can export all alarm data by using the macro EXALARM, and now you can specify the

alarm groups and export them by macro EXALARMGROUP.

Expression Definition of the variable Note

Var1 = EXALARMGROUP(Var2,

Var3,Var4)

Var 1

Return value

Failed 0

Successful 1

Var 2 Alarm group number

Var 3 Exported file name

Var 4

External

storage

device

USB Disk 2

SD Card 3

Command description

Export the alarm data to the external device

Page 47: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

47/53

Variable Type

Internal memory PLC register String Constant

Var 1 ◎ ◎

Var 2 ◎ ◎ ◎

Var 3 ◎ ◎

Var 4 ◎ ◎ ◎

Example

Step 1: complete the alarm setting as follows. Set the reading address to $1000, select the

“output to CSV file”. Set Alarm 1 - Alarm 3 to Group 1, Alarm 4 – Alarm 6 to Group 2, and Alarm 7

– Alarm 9 to Group 3.

based on the specified groups

Note:

1. You must select “output to CSV file” in the alarm setting.

2. Automatically adds the filename extension “-group number” and “.csv” after exporting.

Filenames cannot contain the following characters: \, /, :, *, ?, ”, <, >, and |.

x00 means the end of the filename string.

Page 48: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

48/53

Step 2: create a maintained type element for the alarm triggering bit on the screen to trigger the

alarm. Set the write address respectively to $1000.0, $1000.1, $1000.2…$1000.9.

Step 3: create an alarm history element on the screen for displaying the current alarm history. Set

the group number to a variable which reading address is $302.

Page 49: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

49/53

Step 4: create a value display element which address is $304 and string length is 20. Create two

numeric entry elements which addresses are $302 and $301. Create a drop down menu which

address is $303 and the total state number is 2. In State 0, the State Index is 3 and the text is SD.

For State 1, the State Index is 2 and the text is USB.

Step 5: create a maintained type button which address is $300.0 with the addition of an On

macro.

Page 50: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

50/53

The macro instruction is as follows:

Line 1: set to record the system time at $200 - $206 (Year, Month, Day, Day of the Week,

Hour, Minute, Second)

Line 2: set the file name as “Alarm” with the addition of

“_year_month_day_hour_minute_second” and “_Group” and specify the start

address as $304.

Line 3: export the history buffer to the specified external device based on the specified

group number and filename.

Step 6: download the edited screens to the HMI and plug in the USB Disk to the HMI.

Step 7: trigger Alarm 1 – Alarm 10. Input “1” to the Group No. and select “USB” for the external

storage device on the screen.

Step 8: press the “EXALARMGROUP” button. After the execution, the filename displays and the

return value changes to 1.

Page 51: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

51/53

Step 9: this step is the same as Step 8. Carry on to set Group No. 2 and No. 3 and then press the

“EXALARMGROUP” button respectively.

Step 10: after removing the USB Disk, the exported files in the USB Disk are shown as below:

2.11. Add the USB host waiting time setting in the [System Menu] for DOP-B series HMIs.

Sometimes the HMI cannot detect the USB device when booting and the screen auto-update

does not work properly. It is because the reading speed differs with the USB device

manufacturers. To solve this problem, Delta has added a new function for you to set the waiting

time for USB Disk detection when booting. You can set it by going to [System Menu] > [System

Setting] > [MISC.] > [USBH Insert WaitTime]. In this case, the HMI can execute the auto update

function when booting even if the reading time for the USB Disk is longer. The parameter setting

range is 400 ms – 2500 ms.

Page 52: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

52/53

This parameter setting restores to the default only when you go to [Tools] > [Reset HMI].

Otherwise, the setting remains during HMI screen update and firmware update. For the four

models, DOP-B03S211, DOP-B03S210, DOP-B03E211, and DOP-B05S111, the default value

is 1000 ms. For other models, the default is 400 ms.

Page 53: 產品通報 Newsletter - deltaww.com FBseries TCP LS XBM/XBC/XGK CPU Direct Mitsubishi FX5U Mitsubishi FX5U Ethernet Mitsubishi QnA Series CPU Port ... 產品通報 Newsletter

產 品 通 報 Newsletter

53/53

2.12. More controllers (listed below) can now connect with the Delta HMI.

Manufacturer Connection

method Series

Delta

COM Delta 15MC

Ethernet Delta 15MC TCP

Ethernet Delta 10EMC TCP

COM Delta CNC Controller ASCII

Fatek Ethernet Fatek FBseries TCP

LS COM XBM/XBC/XGK CPU Direct

Mitsubishi

COM FX5U

Ethernet FX5U Ethernet

Ethernet QnA Series CPU Port

Moeller COM EasyPLC 800/MFD

Siemens Ethernet S7 1500 (ISO TCP)

2.13. Add model B07SS411.