AIRBORNE AND RADAR STUDIES OF THE EFFECTS OF DRY ICE SEEDING ON CLOUDS AND PRECIPITATION IN WASHINGTON STATE Report Prepared by Professor Peter V. Hobbs Atmospheric Sciences Department Universi ty of Washington Seattl e, WA 981 95 for PACIFIC NORTHWEST REGIONAL COMMISSION (Fi nal Report for Contract 10990127) BONNEVILLE POWER ADMINISTRATION [Final Report for Contract DE-AC79-80BP18278) and NATIONAL SCIENCE FOUNDATION (Fi nal Report for Grant ATM-79-00948) February 11, 1981

Upload: others

Post on 05-Jul-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 0.1µm 0.5µm DK110A B Integral multiple of 50 ns or 100 ns 50ns 100ns 300ns 500ns 200ns 400ns 1.2μs 2μs Phase A/B Minimum phase difference Counter’s permissible frequency 5MHz

A

B

Integral multiple of 50 ns or 100 ns

50ns100ns300ns500ns

200ns400ns1.2μs2μs

Phase A/BMinimum phase difference

Counter’s permissiblefrequency

5MHz2.5MHz833kHz500kHz

Resolution 0.1 μm80m/min42m/min14m/min8.4m/min

Phase A single cycleMaximum response speed

Resolution 0.5 μm250m/min100m/min33m/min20m/min

DK800SA standard productDK800SB standard product

Special specificationsSpecial specifications

Remarks

Alarm sectionPhase A/B is in high impedance state.

19.5 m or less (excluding 2.5 m standard cable)

Line driver

Output: A/B/reference point

Receiver Line receiver AM26C32 or equivalent

A

BReference-pointoutput

A

B50 ns

200 ns (5 MHz)

DK800SA output signal at maximum response speed (at approx. 80 m/min)

A

B100 ns

400 ns (2.5 MHz)

DK800SB output signal at maximum response speed (at approx. 42 m/min)

A

B50 ns

200 ns (5 MHz)

DK10/25/100/155/205/110 output signal at maximumresponse speed (at approx. 250 m/min)

PR A

VP

EXE

AIRAIR

Pressuresource

Mist separator

Air filter

Speed controller

Regulator Solenoid valve Vacuum ejector

* If extending the cable (Magnescale-specific cable), the supply voltage should be +5 V ±5% at the extension destination. *For an extension cable with spread-out end, use the CE22 Series.

Fig. 2 Pneumatic circuit (vacuum suction)Fig. 1 Pneumatic circuit (pneumatic push)

PR A

Regulator Solenoid valve Precision regulatorPressure

source

Mist separator

Air filter Speed controller

18 19

DK DK110

DT(MT)

UMG

LTLY

DKSDK

DT(MT)

UMG

LTLY

DKSDK

DK110Gauge Cable

I/F unit

I/F unit

Counter

Counter

*1 The measuring force can be changed by mounting optional balancer DZ581 and changing weights.*2 Excluding the interpolation box and connector *3 Excluding cable section and interpolation box

SpecificationsModel DK110NLR5

Measuring range 110 mmMaximum resolution 0.5 µmAccuracy (at 20°C/68°F) 4 µmMeasuring force (at 20°C/68°F)*1 Downward: 1.55±0.15 N (Spindle weight)Maximum response speed 250 m/minReference point Position at spindle movement of 5 mmReference-point response speed Same as the noted maximum response speedOutput A/B/reference point Voltage-differential line driver output (conforming to EIA-422)Protection grade*2 IP50Vibration resistance 10 to 2000 Hz 150 m/s2

Impact resistance 1500 m/s2 11 msOperating temperature 0 to 50 °CStorage temperature −20 to 60 °CPower supply 5 VDC±5 %Power consumption 1 WMass*3 Approx. 800 gOutput cable length 2.4 mFeeler Carbide ball tip, Mounting screw M2.5Accessories Instruction Manual, +P M4 × 5 screw (2pc), Lift lever DZ-161

Resolution0.1µm

Resolution0.5µm

Resolution1µm

Resolution5µm

Stemφ8

Stemφ20

Stemφ32

Stroke5mm

Stroke10mm

Stroke12mm

CommunicationCC-Link

OutputBCD

I/O出力 OutputRS-232C

OutputGo/no-gojudgment

CommunicationEthernet

Stroke32mm

Stroke60mm

Stroke25mm

Stroke30mm

Stroke50mm

Stroke100mm

Stroke110mm

Stroke155mm

Stroke205mm

OutputA/B phase

A/B出力MT接続時

Resolution0.1µm

Resolution0.5µm

Resolution1µm

Resolution5µm

Stemφ8

Stemφ20

Stemφ32

Stroke5mm

Stroke10mm

Stroke12mm

CommunicationCC-Link

OutputBCD

I/O出力 OutputRS-232C

OutputGo/no-gojudgment

CommunicationEthernet

Stroke32mm

Stroke60mm

Stroke25mm

Stroke30mm

Stroke50mm

Stroke100mm

Stroke110mm

Stroke155mm

Stroke205mm

OutputA/B phase

A/B出力MT接続時

Resolution0.1µm

Resolution0.5µm

Resolution1µm

Resolution5µm

Stemφ8

Stemφ20

Stemφ32

Stroke5mm

Stroke10mm

Stroke12mm

CommunicationCC-Link

OutputBCD

I/O出力 OutputRS-232C

OutputGo/no-gojudgment

CommunicationEthernet

Stroke32mm

Stroke60mm

Stroke25mm

Stroke30mm

Stroke50mm

Stroke100mm

Stroke110mm

Stroke155mm

Stroke205mm

OutputA/B phase

A/B出力MT接続時

Resolution0.1µm

Resolution0.5µm

Resolution1µm

Resolution5µm

Stemφ8

Stemφ20

Stemφ32

Stroke5mm

Stroke10mm

Stroke12mm

CommunicationCC-Link

OutputBCD

I/O出力 OutputRS-232C

OutputGo/no-gojudgment

CommunicationEthernet

Stroke32mm

Stroke60mm

Stroke25mm

Stroke30mm

Stroke50mm

Stroke100mm

Stroke110mm

Stroke155mm

Stroke205mm

OutputA/B phase

A/B出力MT接続時

φ4.8

8.512 (111.8)

(489.3)

314

2 - φ4.5 hole

φ8

3

0 −0.1

φ29

0 −0.0

13φ

20

φ4 34

.528φ20

(31)

Cable length 2 m

40

(Ste

m)

(28)

101110

Cable length 0.3 m

Thickness: t = 15.2 mm 2 - φ4.5 hole

ø4.8 17

.4

Unit: mm

* Upon installation, clamp the stem.

DK Series measuring unit output signals

DK Series operating cautions

The signal output from these measuring units are A/B/Z reference point, voltage differential line driver output compliant with EIA-422.

• For the pneumatic push type, use of the pneumatic circuit shown in Fig. 1 enables the feeler to be air driven. Pressure regulation is required depending on the usage condition. A precision pressure regulator (e.g., SMC IR2010 or equivalent) should be used. • For the vacuum suction type, use of the pneumatic circuit shown in Fig. 2 enables the feeler to be air driven.

Moving length of the measuring unit is detected every 50 ns for the DK800SA/DK

and every 100 ns for the DK800SB, and the phase difference proportional

to the amount traveled is output.

The amount of phase difference changes in integer multiples of 50 ns or 100 ns.

Also, the minimum phase difference for the phase A and B is 50 ns

for the DK800SA/DK and 100 ns for the DK800SB.

If the response speed is exceeded, the phase A/B output from this measuring unit changes to high impedance state for about 400 ms as an alarm.

The A/B quadrature output signal by measuring unit is 5 MHz maximum

with a minimum phase difference of 50 ns for DK800SA and is 2.5 MHz maximum

with a minimum phase difference of 100 ns for DK800SB.

The counter or control devise capable of processing these signals should be used.

For DK the A/B quadrature output signal by measuring unit is 5 MHz

maximum with a minimum phase difference of 50 ns .

The counter or control devise capable of processing these signals should

be used.

In the standard specifications, the minimum phase difference is fixed at 50 ns for the DK800SA and 100 ns for the DK800SB, however, the minimum phase differences in the following table below are available as special specifications.

The reference point is the synchronized reference point that is at Hi level when the signal A and signal B are at the Hi level.

Output Signal Phase Difference

Output Signal Alarm Receiver