PROFESOR:COJOCARU-FILIPIUC CARMEN
![Page 2: 137546860 Micromotoare de Curent Continuu Fara Perii](https://reader036.vdocuments.pub/reader036/viewer/2022081505/577cc9c41a28aba711a490b3/html5/thumbnails/2.jpg)
2
MASINI DE C.C. FARA PERII
![Page 3: 137546860 Micromotoare de Curent Continuu Fara Perii](https://reader036.vdocuments.pub/reader036/viewer/2022081505/577cc9c41a28aba711a490b3/html5/thumbnails/3.jpg)
3
SISTEME DE ACŢIONARE ELECTRICE
In masina de c.c. clasica excitatia este reprezentata de infasurari de c.c. instalate pe poli aparenti sau de magneti permanenti pe stator, in timp ce indusul este constituit de infasurari distribuite in crestaturi rotorice alimentate in c.c. printr-un sistem perii - colector.
Excitatie statorica – magneti permanenti
Indusul
Campul de excitatie statoric
Camp de reactie a indusului
![Page 4: 137546860 Micromotoare de Curent Continuu Fara Perii](https://reader036.vdocuments.pub/reader036/viewer/2022081505/577cc9c41a28aba711a490b3/html5/thumbnails/4.jpg)
4
SISTEME DE ACŢIONARE ELECTRICE
Pentru masina de c.c. cu colector sistemul perii-colector are doua functii:
Pentru masina de c.c. fara perii sistemul perii-colector a fost inlocuit cu un circuit electronic de comutatie
Comutatie mecanica Detectia pozitiei rotorice
Transforma c.c. furnizat de sursa in c.a. polifazat in sectiile rotorice. Frecventa curentilor rotorici este proportionala cu viteza de rotatie.
Detectia pozitiei axei campului magnetic rotoric.
![Page 5: 137546860 Micromotoare de Curent Continuu Fara Perii](https://reader036.vdocuments.pub/reader036/viewer/2022081505/577cc9c41a28aba711a490b3/html5/thumbnails/5.jpg)
5
SISTEME DE ACŢIONARE ELECTRICE
A
p
colector
Lamela rotorica l
Sectiunea s a indusului
T1
T2
D1
D2
A
Sectiunea s a indusului
Echivalenta intre comutatia mecanica si comutatie electronica
![Page 6: 137546860 Micromotoare de Curent Continuu Fara Perii](https://reader036.vdocuments.pub/reader036/viewer/2022081505/577cc9c41a28aba711a490b3/html5/thumbnails/6.jpg)
6
SISTEME DE ACŢIONARE ELECTRICE
Prima stare:
conductie
A doua stare:
comutatie
Al treia stare:
conductie
A
p
colector
T1
T2
D1
D2
A
A
p
colector
T1
T2
D1
D2
A
A
p
colector
T1
T2
D1
D2
A
VA pozitiv VA negativ
![Page 7: 137546860 Micromotoare de Curent Continuu Fara Perii](https://reader036.vdocuments.pub/reader036/viewer/2022081505/577cc9c41a28aba711a490b3/html5/thumbnails/7.jpg)
7
SISTEME DE ACŢIONARE ELECTRICE
De precizat:
Excitatia este instalata pe rotor, reprezentat de magneti permanenti
Infasurarile statorice sunt distribuite in crestaturi
Colectorul este suprimat
Este nevoie de un sistem de detectie a pozitiei partii mobile pentru alimentarea fazelor statorice
Inductorul
-dispus pe rotor
Indusul - dispus pe stator
![Page 8: 137546860 Micromotoare de Curent Continuu Fara Perii](https://reader036.vdocuments.pub/reader036/viewer/2022081505/577cc9c41a28aba711a490b3/html5/thumbnails/8.jpg)
8
SISTEME DE ACŢIONARE ELECTRICE
Detectia partii mobile
Directa – utilizand traductori de pozitie
Indirecta – fara senzori
( sensorless)
![Page 9: 137546860 Micromotoare de Curent Continuu Fara Perii](https://reader036.vdocuments.pub/reader036/viewer/2022081505/577cc9c41a28aba711a490b3/html5/thumbnails/9.jpg)
9
SISTEME DE ACŢIONARE ELECTRICE
U0
T’3
T3
T’2
T2 T1
T’1
D1
D’1
D2
D’2
D3
D’3
+
0
A
B
C
N
S1
S2 S 3 Pozitionarea senzorilor
![Page 10: 137546860 Micromotoare de Curent Continuu Fara Perii](https://reader036.vdocuments.pub/reader036/viewer/2022081505/577cc9c41a28aba711a490b3/html5/thumbnails/10.jpg)
10
SISTEME DE ACŢIONARE ELECTRICE
S1
S2
S3
/3 2/3 4/3 5/3 2
Tem1
Tem2
Tem3
Forma de variatie a semnalelor de la senzorii de pozitie
Forma de variatie a tensiunilor electromotoare induse in infasurarile statorice
![Page 11: 137546860 Micromotoare de Curent Continuu Fara Perii](https://reader036.vdocuments.pub/reader036/viewer/2022081505/577cc9c41a28aba711a490b3/html5/thumbnails/11.jpg)
11
SISTEME DE ACŢIONARE ELECTRICE
VARIANTE CONSTRUCTIVE
![Page 12: 137546860 Micromotoare de Curent Continuu Fara Perii](https://reader036.vdocuments.pub/reader036/viewer/2022081505/577cc9c41a28aba711a490b3/html5/thumbnails/12.jpg)
12
SISTEME DE ACŢIONARE ELECTRICE
In functie de pozitia rotorului
Cu rotor interior Cu rotor exterior
stator
rotor
![Page 13: 137546860 Micromotoare de Curent Continuu Fara Perii](https://reader036.vdocuments.pub/reader036/viewer/2022081505/577cc9c41a28aba711a490b3/html5/thumbnails/13.jpg)
13
SISTEME DE ACŢIONARE ELECTRICE Cu rotor interior
Prin forma partii mobile:
Cu rotor disc Cu rotor inel
Dezavantaje:
Suprafata curbata a magnetului permanent
Consolidarea mecanica a magnetilor permanenti
Intrefier relativ mare
![Page 14: 137546860 Micromotoare de Curent Continuu Fara Perii](https://reader036.vdocuments.pub/reader036/viewer/2022081505/577cc9c41a28aba711a490b3/html5/thumbnails/14.jpg)
14
SISTEME DE ACŢIONARE ELECTRICE
In functie de directia fluxului magnetic in intrefier
Cu flux radial Cu flux axial
Cu rotor exterior
Avantaje:
Moment de inertie ridicat, ceea ce permite utilizarea lor in sisteme de actionare cu viteza constanta
Mod de instalare simplu al magnetilor permanenti
Schimb termic mai bun
Mult mai usor de integrat intr-un sistem
![Page 15: 137546860 Micromotoare de Curent Continuu Fara Perii](https://reader036.vdocuments.pub/reader036/viewer/2022081505/577cc9c41a28aba711a490b3/html5/thumbnails/15.jpg)
15
SISTEME DE ACŢIONARE ELECTRICE
uk
R
L
uMk
~
M
uqk
ik
qkMkk
kk uudt
diLRiu
Rezistenta fazei k
Inductanta proprie a fazei k
Tensiunea indusa datorata inductantelor mutuale
Tensiunea indusa de magnetul permanent
Pentru inductante mutuale nule sau pentru curenti constati ea devine zero
![Page 16: 137546860 Micromotoare de Curent Continuu Fara Perii](https://reader036.vdocuments.pub/reader036/viewer/2022081505/577cc9c41a28aba711a490b3/html5/thumbnails/16.jpg)
16
SISTEME DE ACŢIONARE ELECTRICE
Cuplul mediu determinat de o faza:
kqkkk
iuPm
Cuplul total dezvoltat de o masina cu f faze:
f
1k
T
0
kdtmT
1M
2T Fiecare faza are o contributie egala
f
1k
T
0
kqk dtiu2
1
T
0
kqk dtiu2
1f
![Page 17: 137546860 Micromotoare de Curent Continuu Fara Perii](https://reader036.vdocuments.pub/reader036/viewer/2022081505/577cc9c41a28aba711a490b3/html5/thumbnails/17.jpg)
17
SISTEME DE ACŢIONARE ELECTRICE
M
De-a lungul unei perioade in care ik nu e zero uqk este constanta cu valoarea maxima
T
0
kdtifT
1I
Valoarea medie a curentului
kuqk ˆ
kIM
Valoarea de varf a tensiunii induse de magnetul permanent:
O constanta dependenta de geometria motorului si de numarul de faze
T
0
kqk dtiu2
1f
TIuqk
ˆ2
1
![Page 18: 137546860 Micromotoare de Curent Continuu Fara Perii](https://reader036.vdocuments.pub/reader036/viewer/2022081505/577cc9c41a28aba711a490b3/html5/thumbnails/18.jpg)
18
SISTEME DE ACŢIONARE ELECTRICE
Cerinte:
Magnetii permanenti trebuie instalati in circuitul magnetic astfel incat sa se obtina inductia magnetica necesara.
Magnetii trebuie sa aiba:
Stabilitate a caracteristicilor magnetice
Rezistenta la socuri si la agenti chimici.
Rezistenta electrica suficienta
O temperatura de functionare superioara celei a circuitului magnetic.
![Page 19: 137546860 Micromotoare de Curent Continuu Fara Perii](https://reader036.vdocuments.pub/reader036/viewer/2022081505/577cc9c41a28aba711a490b3/html5/thumbnails/19.jpg)
19
ALIMENTARE SI COMANDA PRIN TENSIUNI CVASI-DREPTUNGHIULARE
SISTEME DE ACŢIONARE ELECTRICE
![Page 20: 137546860 Micromotoare de Curent Continuu Fara Perii](https://reader036.vdocuments.pub/reader036/viewer/2022081505/577cc9c41a28aba711a490b3/html5/thumbnails/20.jpg)
20
Alimentarea sondelor Hall
Rotor
Stator
Motorul de c.c. fara perii
Invertor trifazat
Circuit de limitare a curentului
Bloc logic de comanda
Convertor frecventa/tensiune
Regulator de tensiune
Sens de rotatie Start/Stop
Viteza impusa +
-
Sursa de c.c. Curent maxim
SISTEME DE ACŢIONARE ELECTRICE
![Page 21: 137546860 Micromotoare de Curent Continuu Fara Perii](https://reader036.vdocuments.pub/reader036/viewer/2022081505/577cc9c41a28aba711a490b3/html5/thumbnails/21.jpg)
21
OBSERVATII
Invertorul este de tip trifazat, cu 6 celule de comutatie, permitand
alimentarea bidirectionala a fiecarei faze a motorului.
Comutatoarele statice sunt tranzistoare MOSFET sau IGBT avand ca
avantaje:
Comanda in tensiune cu consum redus de putere
Frecventa inalta de comutatie
Posibilitatea integrarii diodei in tranzistor
Pentru comanda Start/Stop se poate utiliza un circuit de tip ‘latch’
SISTEME DE ACŢIONARE ELECTRICE
![Page 22: 137546860 Micromotoare de Curent Continuu Fara Perii](https://reader036.vdocuments.pub/reader036/viewer/2022081505/577cc9c41a28aba711a490b3/html5/thumbnails/22.jpg)
22
Pentru controlul vitezei se poate utiliza:
Un control de tensiune la intrarea invertorului prin variator de
tensiune continua
Control al tensiunii prin utilizarea unui invertor PWM
Trebuie prevazut un circuit de limitare a curentului pentru a evita
curentii periculosi in timpul comutatie! ! Pentru controlul cuplului trebuie stabilita o lege de variatie
tensiune/frecventa.
Motorul trebuie alimentat printr-un invertor controlat in curent. !
SISTEME DE ACŢIONARE ELECTRICE
![Page 23: 137546860 Micromotoare de Curent Continuu Fara Perii](https://reader036.vdocuments.pub/reader036/viewer/2022081505/577cc9c41a28aba711a490b3/html5/thumbnails/23.jpg)
23
ALIMENTARE SI COMANDA PRIN CURENTI CVASI-DREPTUNGHIULARI
SISTEME DE ACŢIONARE ELECTRICE
![Page 24: 137546860 Micromotoare de Curent Continuu Fara Perii](https://reader036.vdocuments.pub/reader036/viewer/2022081505/577cc9c41a28aba711a490b3/html5/thumbnails/24.jpg)
24
Comanda invertorului
Detectia pozitiei rotorice
Sistem de control al curentului
Valoare de referinta
Iref
|Id|
+
-
Control bipozitional de curent
Control liniar de curent cu regulator PI
SISTEME DE ACŢIONARE ELECTRICE
![Page 25: 137546860 Micromotoare de Curent Continuu Fara Perii](https://reader036.vdocuments.pub/reader036/viewer/2022081505/577cc9c41a28aba711a490b3/html5/thumbnails/25.jpg)
25
Control bipozitional de curent
SISTEME DE ACŢIONARE ELECTRICE
![Page 26: 137546860 Micromotoare de Curent Continuu Fara Perii](https://reader036.vdocuments.pub/reader036/viewer/2022081505/577cc9c41a28aba711a490b3/html5/thumbnails/26.jpg)
26
|Id|
2ΔI
e1
e2
i2
e3
i3
i1
SISTEME DE ACŢIONARE ELECTRICE
![Page 27: 137546860 Micromotoare de Curent Continuu Fara Perii](https://reader036.vdocuments.pub/reader036/viewer/2022081505/577cc9c41a28aba711a490b3/html5/thumbnails/27.jpg)
27
Curent de referinta
+
-
Curent masurat
Modulatie cu frecventa variabila
-ΔI ΔI
Comparator cu histerezis
SISTEME DE ACŢIONARE ELECTRICE
![Page 28: 137546860 Micromotoare de Curent Continuu Fara Perii](https://reader036.vdocuments.pub/reader036/viewer/2022081505/577cc9c41a28aba711a490b3/html5/thumbnails/28.jpg)
28
Control liniar de curent prin regulator PI
SISTEME DE ACŢIONARE ELECTRICE
![Page 29: 137546860 Micromotoare de Curent Continuu Fara Perii](https://reader036.vdocuments.pub/reader036/viewer/2022081505/577cc9c41a28aba711a490b3/html5/thumbnails/29.jpg)
29
Curent de referinta
+
-
Curent masurat
Modulatie cu frecventa
fixa
Comparator
Regulator PI +
-
Tensiune de faza statorica
Semnal Pi
SISTEME DE ACŢIONARE ELECTRICE
![Page 30: 137546860 Micromotoare de Curent Continuu Fara Perii](https://reader036.vdocuments.pub/reader036/viewer/2022081505/577cc9c41a28aba711a490b3/html5/thumbnails/30.jpg)
30
CONCLUZII
SISTEME DE ACŢIONARE ELECTRICE
![Page 31: 137546860 Micromotoare de Curent Continuu Fara Perii](https://reader036.vdocuments.pub/reader036/viewer/2022081505/577cc9c41a28aba711a490b3/html5/thumbnails/31.jpg)
31
Avantaje ale masinilor de c.c. fara perii:
Fiabilitate, robustete si simplitate structurala
Neajunsurile comutatiei mecanice sunt eliminate
Control usor de viteza
Mult mai mici din punct de vedere al gabaritului
Posibilitatea alimentarii de la o sursa de c.c. pentru echipamente portabile
SISTEME DE ACŢIONARE ELECTRICE
![Page 32: 137546860 Micromotoare de Curent Continuu Fara Perii](https://reader036.vdocuments.pub/reader036/viewer/2022081505/577cc9c41a28aba711a490b3/html5/thumbnails/32.jpg)
32
SISTEME DE ACŢIONARE ELECTRICE
Aplicatii ale MCC fara perii
roboti
Masini unelte
Vehicule echipate cu motor de tractiune in roata
Scule portabile
Sisteme de calcul
![Page 33: 137546860 Micromotoare de Curent Continuu Fara Perii](https://reader036.vdocuments.pub/reader036/viewer/2022081505/577cc9c41a28aba711a490b3/html5/thumbnails/33.jpg)
![Page 34: 137546860 Micromotoare de Curent Continuu Fara Perii](https://reader036.vdocuments.pub/reader036/viewer/2022081505/577cc9c41a28aba711a490b3/html5/thumbnails/34.jpg)
Moczala H. et al., "Elektrische Kleinmotoren. Wirkungsweise, Bauformen,
Eigenschaften- Hinweise fur den Einsatz", Expert Verlag, 1993.
Simion A., "Maşini electrice speciale pentru automatizări", Ed. Universitas,
Chişinău, 1993.
I.A. VIOREL – G. Henneberger – R. Blissenbach – L Lövenstein: “Transverse
Flux Machines. Their behavior, design, control and applications”, MEDIAMIRA,
Cluj-Napoca, 2003,
Yeadon PW.H., Yeadon A.W, "Handbook of small electric motors", McGraw-Hill,
New York, 2001.
Bibliografie
![Page 35: 137546860 Micromotoare de Curent Continuu Fara Perii](https://reader036.vdocuments.pub/reader036/viewer/2022081505/577cc9c41a28aba711a490b3/html5/thumbnails/35.jpg)
Armensky E.V., Falk G.B., "Fractional horsepower electrical machines", MIR Publisher, Moscova, 1978.
Bart S.F. et al., "Measurements of electric micromotor dynamics", Proc. of
ASME Winter Annl. Meeting, Dallas, vol. 19 (1990), pp. 19-29.
Boldea, I.: “Reluctance synchronous machines and drives”, Clarendon Press,
Oxford, 1996
Biro K.A.,Viorel I.A.,Syabo L.,Henneberger G. “ Maşini electrice speciale ”,
Editura MEDIAMIRA, Cluj-Napoca, 2005.
Galan N., "Motorul electric cu histerezis", Ed. Tehnică, Bucureşti, seria Maşini şi
aparate electrice, 1974.
G. Henneberger, I. A. Viorel: “Variable Reluctance Electrical Machines”
Shaker Verlag, Aachen, Germania 2001
Măgureanu R., Vasile N., "Servomotoare fără perii tip sincron", Ed. Tehnică,
Bucureşti, seria Maşini şi aparate electrice, 1990.
Miller, T.J.E.: „Switched reluctance motors and their control”. Clarendon
Press, Oxford 1993.
Bibliografie