Data Center Products
Pat GentileConsulting Engineer Specialist
APC by Schneider Electric
Who is APC? A Heritage of leadership, experience and innovation
● APC was acquired by Schneider Electric in 2007● MGE UPS Systems, another division of Schneider
Electric, merged with APC● Together they represent the IT Business Unit of Schneider Electric
APC by Schneider Electric
Symmetra LX Symmetra PX Symmetra MW
Smart-UPS Smart-UPS VT MGE Galaxy MGE EPS
The broadest UPS portfolio in the industry with solutions from the wiring closet to the data center to the factory floor.
Portfolio from 10kVA to 1600kVA
APC by Schneider Electric
Where does the power go?
POW
ER
syst
em
POW
ER
syst
em
COOLI
NG
syst
em
COOLI
NG
syst
em
Infrastructure
IT
APC by Schneider Electric
Typical UPS efficiency curve
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
0%100%90%80%70%60%50%40%30%20%10%0%
Nominal 92% efficiency only applies when UPS load is over 70%
Below 30% loadefficiency drops rapidly
UPS Load% of full power rating
APC by Schneider Electric
Scalable Modular UPS● White space or backroom install● Double conversion online topology● 96% efficiency – highest in its class● Input PF regulated to unity● 400 or 480VAC input/output● 1.0 output PF (kW=kVA)● Dual mains● Internal bypass static switch● On-the-fly/ off-line firmware
upgrades● Event logging w/ graphs● Regulated fan speed (reduces
noise)● Extended life batteries (5 – 8 yrs)● Predictive maintenance● Waveforms graphically displayed
Redundant, Scalable, High Availability Power Protection
Key Features
APC by Schneider Electric
25kW50kW75kW100kW125kW150kW175kW200kW225kW250kW275kW300kW325kW350kW375kW400kW425kW450kW475kW500kW of High-Efficiency Scalable Power Protection
Symmetra®® PX250/500kW
APC by Schneider Electric
Instrumented with local display and networked to central management system
Integral row-based air conditioners
Air conditioners return neutralized (ambient room temperature) air to the front of the racks
Hot air is exhausted to the hot aisle andreturns to the back of the air conditioners
Cold aisle
Modular Designs
Hot aisle
APC by Schneider Electric
400 VAC Data Center Power Distribution
400 VAC Configuration Utilizes no PDUs to Transform UPS voltage to Server Power Supply Voltages 400Y/230 VAC, 3 Phase, 4 W + G
to Rack. Distribution More Closely Sized to
the System Rating. Single Autotransformer or 400 VAC
UPS System can be used. Greatly Reduced Weight and
Footprint Considerations in the Data Center White Space.
No or Reduced XFMR Heat Losses 400Y/230 VAC. Five Conductors, A,
B, C, N, G, Lower Amperage
APC by Schneider Electric – Name – Date
What is Modular Power Distribution?
●A simple, cost effective solution to install 3PH Power Distribution infrastructure
●Populated with Breaker Modules as capacity is needed
●No hot-work●No downtime
●Includes:●Enclosure●Breaker Module with whip (cord set)
and connector●Branch Current Monitoring●Breaker Position Monitoring
APC by Schneider Electric – Name – Date
High Density, High Efficiency Distribution
Distribution Modules
• 20A • IEC309 connector• 3XC19 • Circuit monitoring included• Breaker position monitoring
½ Rack Power Distribution Unit (PDU)½ Rack Remote Power Panel (RPP)
RPP400V RPP (transformerless)• 277 kW 400A• 72 Poles• 24 Modules
PDU480V:415V/240Y• 266kW @320A• 72 Poles• 24 Modules
APC by Schneider Electric – Name – Date
• RMS:• Voltage available to load at each phase• Current in each phase of distribution cable
• Percent current loading in each phase of distribution cable• Total KW usage of each distribution cable• Total KWh usage for each distribution cable• Individual reset of KWh usage per distribution cable• User programmable string to identify:
• Location of load equipment fed by distribution cable• Load of equipment, fed by distribution cable
• User programmable upper and lower• Warning current thresholds for each distribution cable• Critical current thresholds for each distribution cable
Power Monitoring Features
APC by Schneider Electric – Name – Date
Next Gen Rack PDU Design Benefits
IndustryStandard
APCLow
Profile
51.2mm 90 mm
IndustryStandard
APCLow
Profile
51.2mm 90 mm
Locking IEC Cords
Optional solution to secure your power cords
Temperature/Humidity
Probe input cord allows use of external temperature/humidity probes
Low profile breakers
New low profile breaker for decreased interference with rack mounted IT equipment and increased airflow efficiency (select AP8000 series Rack PDUs)
Space saving form factors
Low profile 0U designs maximize available space
Local display
Local display allows users to make real-time decisions
Outlet Status LED
Indicate on/off status of each individual outlet (AP8900 and AP8600 series only)
APC by Schneider Electric
Next Generation Rack PDU Features
Industry’s FirstUltra Low-Profile Breakers
Avoid space interference with IT equipment and improve airflow with these low profile branch-rated, hydraulic-
magnetic type breakers – The best overcurrent protection for high temperature rack enclosure environments!
Easy to install and space saving solution to secure critical power cords
New Interactive LCD Display and Advanced Remote Management Connectivity
APC ExclusiveLocking IEC Connectors
IndustryStandard
3.5”
APCLowProfile
51.3mm2.0”
88.9mm
APC by Schneider Electric
What is ‘In-Row’ Cooling?
Traditional (Perimeter) Design
In-Row Design
APC by Schneider Electric
● InRow Cooling● Close coupled heat source and heat removal● Raised floor not required for air distribution
InRow Cooling Architecture
APC by Schneider Electric
Row Cooling Product SolutionsModel # ACRD1XX,
ACRD5XXACRD2X
XACRC1XX, ACRC 5XX ACRP1XX ACRP5XX ACSC1XX
Product Family InRow RD InRow
RD InRow RC InRow RP InRow RP InRow SC
Heat Rejection Air-Cooled Water/
GlycolChilled Water Air Cooled Chilled
WaterSelf
Contained
Nominal Capacity
2.8 Ton / 10kW
8.2Ton / 29 kW
2.8 Ton
/10kW
5 Ton / 18kW,
12.3 Ton / 43 kW
8.2 Ton / 29kW
23.3 Ton / 43kW
1.4 Ton / 5kW
Nominal Width
12 in (300 mm), 24 in (600mm)
12 in (300 mm)
12 in (300mm),
24 in (600mm)
24 in (600 mm)
24 in (600 mm)
12 in (300 mm)
APC by Schneider Electric
Air ContainmentRack Air Containment System (RACS)
Hot Aisle Containment System (HACS)
APC by Schneider Electric
InRow OA System Architecture
Refrigerant Distribution Unit
(RDU)
Chilled Water Piping (RDU to Chiler)
R-134a Piping (RDU to InRow OA)
InRow OA Mounting Kit
InRow OA
IT Racks
Air Containment Curtain
Modular Piping Headers
APC by Schneider Electric
InRow OA Design Benefits
Primary and Secondary Power Inputs
Micro Channel Heat Exchanger
Integrated Lighting
Variable Speed Hot Swappable Fans
Rollers
Aisle Width: Independent
All content in this presentation is protected – © 2008 American Power Conversion Corporation
Uniflair Room Cooling
Technical Presentation
APC by Schneider Electric
Immersed Electrode Humidifier (Carel)
Backward Curved EC Fans (EBM Pabst)
30% Efficiency Air Filters (MERV 7)
Temperature and Humidity Sensor (Carel)
Microprocessor Controller (Carel)
Manual Disconnect Switch (Schneider Electric)
User Interface (Carel)
Blue-Fin Coated Cooling Coil (Heatcraft/Luvata)
2 or 3-Way Valve & Actuator (Schneider Electric)
Integrated Airflow Switches
Front Service Access
1
2
3
4
5
6
7
8
9
10
11
1
2
3
4
56 7
8
9
10
11
Pictured: TDCV2500 (25-Ton est. capabity)
Efficient - Components
APC by Schneider Electric
EcoBreeze – Theory of OperationHigh Level Application
● Sits outside the data center● Optional ground or roof placement● Turn-key solution
●Set it in place●Run power and water to the unit●Duct it to the space
*Not to scale
APC by Schneider Electric
3. Does their data center design allow space for the EcoBreeze outside the building?
●The EcoBreeze is a large footprint. The customer site will need the required space to fit the system, including service clearances
●40’ Frame area 320ft2
●20’ Frame area 160ft2
●Total 40’ frame area with service clearances is 1024 ft2
●Total 20’ frame area with service clearances is 544ft2
●This includes clearance on a ground or roof installation
clearances
4ft8ft – 10ft
APC by Schneider Electric
Hot Air is returned from the Data Center
98°F-102°F(~37°C-39°C)
Cool Ambient Air is brought in by the Scavenger Fan
Indirect Heat exchange between the IT and ambient airstreams (Evaporative or Air-to-Air)
Cool IT Air is supplied through the evaporator coil and back to the Data Center
77°F(~25°C)
Hot ambient air is expelled through the condenser to the
atmosphere
All content in this presentation is protected – © 2008 American Power Conversion Corporation