50byn-1sb

Upload: soineth-guzman

Post on 14-Apr-2018

217 views

Category:

Documents


0 download

TRANSCRIPT

  • 7/29/2019 50byn-1sb

    1/4

    50BYN006-014

    SINGLE-PACKAGED INDOORAIR-COOLED VERTICAL COOLING UNIT

    PERFORMANCE DATA CERTIFIED DIMENSION PRINT

    HEAD PRESSURE CONTROL AND

    HEATING COIL DIMENSION PRINT

    50BYN-1SB

  • 7/29/2019 50byn-1sb

    2/4

    Date: Supersedes: 50BYN006-014AIR-COOLED VERTICAL PACKAGE UNIT

    50BYNRev.:

    JOB NAME: LOCATION:

    BUYER: BUYER P.O. # CARRIER #

    UNIT NUMBER: MODEL NUMBER:

    PERFORMANCE DATA CERTIFIED BY: DATE:

    DESCRIPTION

    These indoor single packaged air-cooled vertical units are available with optional steam or hot water heating. Unitsare completely factory wired, piped, and ready for installation. Units are designed for vertical or horizontal evaporatorair discharge with rear air return. They are designed for ducted supply and free or ducted return applications. 50BYNunits have an internal air-cooled condenser with condenser air inlet and discharge on the same face of the unit. Thesefully painted vertical package units offer economical air conditioning for offices, restaurants, cinemas, factories, ware-houses, retail shops, and spot cooling applications.

    FEATURES

    Standard one-year product warranty.

    Four-year extended protection plan for the motor compressor.

    Side access filter frame for 1 or 2 disposable type filters. No tools re-quired to change filters.

    Three-phase TEFC (Totally Enclosed Fan Cooled) evaporator and con-denser fan motor with same voltage as unit. It has internal thermal over-load protection and permanently lubricated bearings.

    Built in 24-volt control system.

    Adjustable belt drive centrifugal forward curve fans on evaporator andcondenser are statically and dynamically balanced.

    Carrier scroll compressor mounted on vibration isolation on all sizes.

    Acoustically lined compressor compartment.

    Two-stage capacity control on 10 and 12 ton units.

    Cycle-LOC and 5-minute Time Guard protection on each circuit.

    High and low pressure switches on each circuit.

    Replaceable filter drier in each circuit.

    Adjustable thermostatic expansion valves.

    Sloped condensate pan and double wall construction in evaporator sectionfor optimum indoor-air quality.

    Dual drain connections for condensate pan overflow protection.

    Units are vertical air discharge or may be field converted to horizontal dis-charge (except 12 ton size).

    Return may be free blow or ducted.

    All units are UL and UL, Canada listed and rated in accordance withARI 210.

    All service may be done through the front of the unit.

    Baked enamel painted cabinet meets 500 hr salt spray requirements.

    Coils are aluminum plate fin mechanically bonded to copper tubes.

    Unit manufactured in ISO 9002 facility.

    PERFORMANCE DATA

    Unit Operating Weight lb

    COOLING:

    Gross Total Capacity Btuh

    Gross Sensible Capacity Btuh

    Outdoor Design dB

    Indoor Entering Air dB wB

    Indoor Leaving Air dB wB

    Outdoor cfm

    Condenser esp in. wg

    Rpm Bhp

    Evaporator-Fan cfm

    Esp in. wg

    Rpm Bhp

    ACCESSORY HEATING DATA

    Hot water SteamAccessory Heating Coil Capacity Btuh

    Outdoor Design dB F

    Indoor Entering Air dB F Leaving dB F

    Gpm Ewt F Lwt F

    Pressure Drop ft water

    Steam Pressure Psig

    Coil Air Pressure Drop in. water

    ELECTRICAL DATA

    Unit Power Supply Volts Ph Hz Condenser Fan Motor FLA Motor Hp

  • 7/29/2019 50byn-1sb

    3/4

    CERTIFIED DIMENSION PRINT

    DIMENSIONAL CHART

    DIMUNIT 006 UNIT 008 UNIT 012 UNIT 014

    mm ft-in. mm ft-in. mm ft-in. mm ft-in.

    A 1800 5-1058 1800 5-1058 1780 5-1058 1780 5-10

    B 1040 3- 5 1231 4- 012 1613 5- 312 1804 5-11

    C 690 2- 318 690 2- 318 745 2- 338 745 2- 338

    D 765 2- 618 765 2- 618 825 2- 812 825 2- 812

    E 355 1- 2 420 1- 412 608 2- 0 675 2- 258

    F 170 0- 63

    4

    158 0- 61

    4

    191 0- 71

    2

    193 0- 75

    8

    G 320 1- 058 357 1- 2 402 1- 378 452 1- 534

    H 310 0- 014 350 0- 134 372 1- 258 424 0- 434

    J 593 1-1138 593 1-1138 665 1- 214 665 0- 214

    K 554 1- 978 554 1- 978 457 1- 1 457 0- 6

    L 584 1-11 584 1-11 584 1-11 584 1-11

    M 23 0- 078 23 0- 078 21 0- 078 21 0- 078

    N 17 0- 058 17 0- 058 17 0- 058 17 0- 058

    P 116 0- 012 116 0- 012 116 0- 012 116 0- 012

    Q 43 0- 134 43 0- 134 43 0- 134 43 0- 134

    R 605 1-1134 605 1-1134 605 1-1134 605 1-1134

    S 50 0- 2 55 0- 218 55 0- 218 55 0- 218

    T 360 1- 21

    8

    400 1- 33

    4

    357 0- 2 357 0- 2V 50 0- 2 20 0- 078 24 0- 1 24 0- 1

    W 660 2- 2 660 1- 2 660 2- 2 660 2- 2

    X 535 1- 918 535 1- 918 590 1-1114 590 1-1114

    Y 190 0- 712 190 0- 712 190 0- 712 190 0- 712

    Z 124 0- 478 124 0- 478 124 0- 478 124 0- 478

    AA 475 1- 634 475 1- 634 475 1- 634 475 1- 634

    AB 140 0- 512 140 0- 512 140 0- 512 140 0- 512

    AC 60 0- 238 60 0- 238 60 0- 238 60 0- 238

    AD 21 0- 078 21 0- 078 21 0- 078 21 0- 078

    AE 225 0- 878 225 0- 878 225 0- 878 225 0- 878

    AF 155 0- 618 155 0- 618 155 0- 618 155 0- 618

    AG 190 0- 71

    2

    190 0- 71

    2

    190 0- 71

    2

    190 0- 71

    2

    AH 73 0- 278 61 0- 238 59 0- 238 59 0- 238

    AJ 895 2-1114 111 0 3 - 934 1495 4-1078 1686 5- 638

    AK 386 1- 314 405 1- 4 260 0-1058 356 1- 2

    AL 433 1- 5 480 1- 678 433 1- 5 433 1- 5

    AM 275 0-1078 2 75 0 -1 078

    AN 433 1- 5 433 1- 5

    AP 80 0- 318 80 0- 318 80 0- 318 80 0- 318

    AQ 55 0 2 -1 058 1070 3- 618 1455 4- 914 1645 5- 434

    AR 41 0- 158 41 0- 158 41 0- 158 41 0- 158

    AS 533 1- 9 605 1-1178 807 2- 734 920 3- 014

    AT 347 1- 158 355 1- 2 375 1- 234 395 1- 312

    AV 50 0- 2 50 0- 2 50 0- 2 50 0- 2AW 231 0- 918 231 0- 918 169 0- 612 169 0- 612

    NOTES:1. Dimensions in [ ] are in millimeters.

    2. Center of gravity.

    3. Direction of airflow.4. One side of unit must have minimum of 3 [914] clear-

    ance for filter removal

    CORNER WEIGHTS

    UNIT 006 UNIT 008 UNIT 012 UNIT 014

    kg lb kg lb kg lb kg lb

    A 65.3 144 84 185 107 236 108 238

    B 68.5 151 81 179 107 236 113 248

    C 69.4 153 89 136 108 239 127 280

    D 65.8 145 92 203 108 239 119 263

    3

    CUT ALONG DOTTED LINE CUT ALONG DOTTED LINE

    - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

  • 7/29/2019 50byn-1sb

    4/4

    CERTIFIED HEAD PRESSURE CONTROL AND HEATING COILS DIMENSION PRINT

    4