FT 7950/7960 1 RESET E# 101 & E# 541 --> E# 548 & E# 940 Vaøo SP# Mode --> Taét roài môû coâng taéc chính SERVICE CALL CONDITIONS SC101 - Exposure lamp malfunction - abnormal on/off Definition: [level: A] 1) An A/D conversion level higher than 21 is detected more than 50 times while the relay trigger is on and the lamp t rigger is off. 2) An A/D conversion level lower than 6 is detected more than 50 times while the exposure lamp is on. Possible causes  _ Exposure lamp open . _ Expo sure lamp thermoswitch open  _ Optics control board defective . _ AC drive bo ard defective SC102 - Exposure lamp malfunction - abnormal process control Definition: [level: A] 1) VL/VR correction not finished within 50 seconds. 2) ADS adjustment not finished within 15 seconds. Possible cause:  _ ADS sensor defective . _ Drum potential sen sor defective .  _ Main control board defective . _ Optics con trol board defective  _ AC drive board defective SC103 - Power source frequency detection error Definition: [level: D] Frequencies detected out of the 45Hz to 65Hz range. Possible causes:  _ Abnormal power source . _ Electrical nois e .  _ AC drive board defective . _ Optics control bo ard defective Definition: [level: D] The scanner start signal is received even if the main relay off condition is detected. Possible causes:  _ Main relay defective . _ Communication e rror between the main control board and the optics control board because of a poor harness connection.  _ Optics control board defective . _ Electrica l noise SC105 - Zero-cross abnormal Definition: [level: D] 1) The optics control board does not detect a zero-cross signal for more than 1 second when the main relay trigger on the optics control board is on. 2) The optics control board does not detect a zero-cross signal for more than 10 seconds when the main switch is turned on. Possible causes:  _ Main relay defective . _ Optics control board de fective .  _ AC drive board defective

Upload: hai-ha

Post on 05-Jul-2018

218 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 7950

8/16/2019 7950

http://slidepdf.com/reader/full/7950 1/15

FT 7950/7960

1

RESET E# 101 & E# 541 --> E# 548 & E# 940

Vaøo SP# Mode --> Taét roài môû coâng taéc chính

SERVICE CALL CONDITIONSSC101 - Exposure lamp malfunction - abnormal on/off Definition: [level: A]1) An A/D conversion level higher than 21 is detected more than 50 times whilethe relay trigger is on and the lamp trigger is off.2) An A/D conversion level lower than 6 is detected more than 50 times whilethe exposure lamp is on.Possible causes _ Exposure lamp open . _ Exposure lamp thermoswitch open

 _ Optics control board defective . _ AC drive board defectiveSC102 - Exposure lamp malfunction - abnormal process controlDefinition: [level: A]1) VL/VR correction not finished within 50 seconds.2) ADS adjustment not finished within 15 seconds.Possible cause: _ ADS sensor defective . _ Drum potential sensor defective . _ Main control board defective . _ Optics control board defective _ AC drive board defective

SC103 - Power source frequency detection error Definition: [level: D]Frequencies detected out of the 45Hz to 65Hz range.Possible causes: _ Abnormal power source . _ Electrical noise . _ AC drive board defective . _ Optics control board defectiveDefinition: [level: D]The scanner start signal is received even if the main relay off condition isdetected.Possible causes: _ Main relay defective . _ Communication error between the main control boardand the optics control board because of a poor harness connection.

 _ Optics control board defective . _ Electrical noiseSC105 - Zero-cross abnormalDefinition: [level: D]1) The optics control board does not detect a zero-cross signal for more than 1second when the main relay trigger on the optics control board is on.2) The optics control board does not detect a zero-cross signal for more than10 seconds when the main switch is turned on.Possible causes: _ Main relay defective . _ Optics control board defective . _ AC drive board defective

Page 2: 7950

8/16/2019 7950

http://slidepdf.com/reader/full/7950 2/15

FT 7950/7960

2

SC120 - Scanner home position sensor abnormal - stays off Definition: [level: D]The scanner home position sensor does not detect the on condition even if the

scanner returns home.Possible causes: _ Scanner home position sensor defective _ Optics control board defective . _ Scanner HP sensor short

SC121 - Scanner home position sensor abnormal - stays onDefinition: [level: D]The scanner home position sensor does not detect the off condition even if thescanner has moved 40 mm away from the scanner home position sensor.Possible causes: _ Scanner home position sensor defective . _ Scanner motor defective _ Scanner HP sensor open . _ Optics control board defective

SC124 - Scanner motor encoder abnormalDefinition: [level D]1) The scanner motor encoder connector is disconnected.2) The optics control board does not receive the encoder signal within 200 msafter the scanner motor starts rotating.Possible cause: _ Scanner motor encoder defective . _ Scanner motor defective _ Connector disconnected (CN514, 515, 516)

SC125 - Low scanner speedDefinition: [level: D]

1) The scanner speed, detected by the optics control board through theencoder, is lower than the specified speed.2) When the scanner returns to the home position, it stops before reaching thehome position sensor.Possible causes: _ Scanner drive motor defective . _ Optics control board defective _ Abnormal load of the scanner drive

SC126 - High scanner speedDefinition: [level: D]The scanner overruns by more than 12 mm after passing the scanner homeposition.

Possible causes: _ The scanner drive motor defective . _ Optics control board defective

SC127 - Scanner drive motor encoder failureDefinition: [level: D]The scanner rotating direction detected by the optics control board through theencoder is opposite to the specified direction.Possible causes: _ Scanner drive motor defective . _ Optics control board defective

Page 3: 7950

8/16/2019 7950

http://slidepdf.com/reader/full/7950 3/15

FT 7950/7960

3

SC128 - Scanning start speed abnormalDefinition: [level: C]The scanner motor speed does not reach the standard value before the

scanner reaches the original leading edge position.Possible cause: _ Scanner motor defective . _ Optics control board defective _ Scanner drive section defective

SC129 - Scanner motor speed abnormalDefinition: [level: C]The scanner motor speed is out of the ±10% tolerance limit while scanning theoriginal.Possible cause: _ Scanner motor defective . _ PSU (38V output) defective

SC140 - Lens vertical home position sensor abnormal - stays off Definition: [level: D]When the lens returns to the home position, the lens vertical home positionsensor does not detect the on condition within 2,100 pulses.Possible causes: _ Lens vertical home position sensor shorted _ Lens vertical drive motor defective . _ Optics control board defective

SC141 - Lens vertical home position sensor abnormal - stays onDefinition: [level: D]When the lens leaves the home position, the lens vertical home position sensor does not detect the off condition within 1,200 pulses.

Possible causes: _ Lens vertical home position sensor open _ Lens vertical drive motor defective . _ Optics control board defective

SC142 - Lens horizontal home position sensor abnormal - staysoff Definition: [level: D]When the lens returns to the home position, the lens horizontal home positionsensor does not detect the on condition within 1,400 pulses.Possible causes: _ Lens horizontal home position sensor short _ Lens horizontal drive motor defective . _ Optics control board defective

SC143 - Lens horizontal home position sensor abnormal - staysonDefinition: [level: D]When the lens leaves the home position, the lens horizontal home positionsensor does not detect the off condition within 1,000 pulses.Possible causes: _ Lens horizontal home position sensor open _ Lens horizontal drive motor defective . _ Optics control board defective

Page 4: 7950

8/16/2019 7950

http://slidepdf.com/reader/full/7950 4/15

FT 7950/7960

4

SC144 - 3rd scanner home position sensor abnormal - stays off Definition: [level: D]When the 3rd scanner returns to the home position, the 3rd scanner home

position sensor does not detect the on condition within 1,400 pulses.Possible causes: _ 3rd scanner home position sensor shorted _ 3rd scanner drive motor defective . _ Optics control board defective

SC145 - 3rd scanner home position sensor abnormal - stays onDefinition: [level: D]When the 3rd scanner leaves the home position, the 3rd scanner homeposition sensor does not detect the off condition within 700 pulses.Possible causes: _ 3rd scanner home position sensor open _ 3rd scanner drive motor defective . _ Optics control board defective

SC146 - Abnormal magnification operationDefinition: [level: D]The lens vertical drive motor, the lens horizontal drive motor, or 3rd scanner motor moves for no apparent reason in the ready condition.Possible causes: _ Lens vertical drive motor defective . _ Lens horizontal drive motor defective _ 3rd scanner drive motor defective . _ Optics control board defective

SC190 - Optics thermistor openDefinition: [level: D]The optics thermistor is open.

Possible causes: _ Optics thermistor open

SC193 - APS abnormalDefinition: [level B]1) Abnormal rotation of the APS sensor motor is detected 4 times consecutivelyor 10 times totally after the main switch is turned on.2) The value of APS correction is more than 500 or less than –500.Possible cause: _ APS sensor defective

SC302 - Charge corona leakageDefinition: [level: D]1) When charge corona leakage is detected.2) Charge corona output is not detected for 200 ms.3) Grid voltage is more than 1295 V or no output for 100 ms.Possible causes: _ Main charge corona unit defective . _ Main charge power pack defective _ High voltage control board defective

Page 5: 7950

8/16/2019 7950

http://slidepdf.com/reader/full/7950 5/15

FT 7950/7960

5

SC303 - Charge corona wire cleaner failureDefinition: [level: C]The charge corona wire cleaner does not move back to the end block within 90

seconds.Possible causes: _ Charge corona wire cleaner drive motor defective _ High voltage control board defective

SC341 - Development motor lockedDefinition: [level: D]The development motor lock signal stays low for more than 1 second in thedevelopment motor on condition.Possible causes: _ Extra load in the development unit . _ Development motor defective

SC345 - Toner collection motor lockedDefinition: [level: D]The toner collection motor lock signal stays low for more than 2.5 seconds inthe toner collection motor on condition.Possible cause: _ Toner collection motor defective . _ Extra load of the toner collection mechanism

SC346 - Toner recycle motor disconnectedDefinition: [level: D]The toner recycle motor is disconnected for more than 1 second.Possible cause:

 _ The toner recycle motor connector is disconnected.SC351 - Abnormal VSG detection (VSG > 4.2V)Definition: [level: C]The detected VSG value is not 4 + 0.2 V.Possible causes: _ ID sensor defective . _ Main control board defective . _ Drum defective

SC352 - Incomplete TD sensor initial settingDefinition: [level: C]The output voltage of the TD sensor is higher than 2.1 V or lower than 1.75 Vduring the developer initial setting mode.VOUT to get 2.0 V for the TD sensor output is lower than 1.9 V.Possible causes: _ Connector [A] not connected correctly _ Toner density sensor defective . _ Abnormal toner concentration

SC353 - Abnormal VSP detection (VSP > 2.5 V: lighter pattern)Definition: [level: C]VSP is 2.5 V or higher.Possible causes: _ ID sensor defective . _ Drum . _ High voltage control board defective _ Poor development bias terminal contact

Page 6: 7950

8/16/2019 7950

http://slidepdf.com/reader/full/7950 6/15

FT 7950/7960

6

SC354 - Abnormal VSG detection (VSG < 2.5 V)Definition: [level: C]1) VSG is 2.5 V or less.

2) VSGP is 2.5 V or less.Possible causes: _ ID sensor defective . _ Drum . _ Dirty charge corona casing _ Quenching lamp defective . _ Erase lamp defective _ Cleaning blade defective . _ Dirty ID sensor 

SC355 - Abnormal VTD detection (VTD > 4.7 V)Definition: [level: C]VTD is 4.7 V or higher.Possible causes: _ Toner density sensor defective . _ Toner concentration too low

SC356 - Abnormal VTD detection (VTD < 0.5 V)Definition: [level: C]VTD is less than 0.5 V.Possible causes: _ Toner density sensor defective . _ Toner concentration is too high

SC358 - Abnormal VSP detection (VSP/VSG < 2.5%)Definition: [level: C]VSP/VSG is less than 2.5%.Possible causes: _ ID sensor defective . _ Drum . _ Toner scattering

SC361 - Incomplete drum potential sensor calibrationDefinition: [level: C]When the process control initial setting is performed and a development bias of  –100 V or –800 V is applied to the drum shaft, the drum potential voltage is outof these ranges: 0.1 < V–100 < 1.6 [V] or 2.3 < V–800 < 5.0 [V].Possible causes: _ Drum potential sensor defective . _ Drum shaft terminal not grounded _ Drum . _ Charge corona unit defective . _ Development power pack defective

SC364 - Abnormal VD detectionDefinition: [level: C]VD is out of specification (VR + 770 + 20 V).Possible causes: _ Drum potential sensor defective . _ Drum . _ Charge corona unit defective

SC365 - Abnormal VL detectionDefinition: [level: C]VL is out of specification (VR + 140 + 20 V).Possible causes: _ Drum potential sensor defective . _ Drum _ Charge corona unit defective . _ Optics too dirty

Page 7: 7950

8/16/2019 7950

http://slidepdf.com/reader/full/7950 7/15

FT 7950/7960

7

SC366 - Abnormal VRDefinition: [level: C]VR is larger than 360 V during the process control initialization.

Possible causes _ Drum . _ Drum shaft terminal not ground

SC402 - Transfer current leakageDefinition: [level: D]

1) The transfer power pack output voltage exceeds 360 µ A for 80 ms or more.2) No transfer current is detected.Possible causes: _ Transfer belt defective . _ Transfer power pack defective _ Poor contact at the transfer bias roller or discharge plate terminals

SC440 - Abnormal main motor speed

Definition: [level: D]The lock signal stays low for 1.0 second or more when the main motor is on.Possible causes: _ Main motor defective

SC500 - Abnormal manual feed drive motor speedDefinition: [level: D]The lock signal stays low for 1.0 second or more when the manual feed motor is on.Possible causes: _ Manual feed motor defective

SC501 - Abnormal paper feed drive motor speed

Definition: [level: D]The lock signal stays low for 1.0 second or more when the paper feed motor ison.Possible causes: _ Paper feed motor defective . _ Paper feed control board defective

SC502 - Abnormal 1st lift motor movementDefinition: [level: B]1) The 1st lift sensor detects a high condition for 10 seconds or more after the1st lift motor starts. The first time, after the paper tray is opened and closed,the 1st lift motor starts again.

2) The right tray down sensor does not turn on within 10 seconds after the 1stlift motor starts lowering the tray. If any of these conditions occur twice, this SC isdisplayed.Possible causes: _ 1st lift sensor shorted . _ 1st lift motor defective _ Paper feed control board defective . _ Right tray down sensor defective

Page 8: 7950

8/16/2019 7950

http://slidepdf.com/reader/full/7950 8/15

FT 7950/7960

8

SC503 - Abnormal 2nd lift motor movementDefinition: [level: B]The 2nd lift sensor detects a high condition for 10 seconds or more after the

2nd lift motor starts. The first time, after the paper tray is opened and closed,the 2nd lift motor starts again. If the above condition occurs twice, this SC isdisplayed.Possible causes: _ 2nd lift sensor shorted . _ 2nd lift motor defective . _ Paper feed control board defective

SC504 - Abnormal 3rd lift motor movementDefinition: [level: B]The 3rd lift sensor detects a high condition for 10 seconds or more after the 3rdlift motor starts. The first time, after the paper tray is opened and closed, the 3rdlift motor starts again. If the above condition occurs twice, this SC is displayed.Possible causes: _ 3rd lift sensor shorted . _ 3rd lift motor defective . _ Paper feed control board defective

SC506 - Abnormal 3.5 k LCT motor movementDefinition: [level: B]1) The LCT lift sensor detects a low condition for 30 seconds or more after theLCT motor starts.2) The LCT tray down sensor does not turn on within 30 seconds after the LCTmotor starts lowering the tray.3) If the above condition occurs twice, this SC is displayed.

Possible causes: _ LCT motor defective . _ LCT lift sensor shorted . _ LCT tray down sensor defective

SC507 - Abnormal 3.5 k LCT feed motor movementDefinition: [level: B]The LCT feed motor is locked for 1 second or more after this motor starts.Possible causes: _ LCT feed motor defective

SC508 - Abnormal tandem rear fence drive motor movementDefinition: [level: B]1) It takes 10 seconds or more for the rear fence return sensor to detect the on

condition after the rear fence drive motor starts.2) It takes 10 seconds or more for the rear fence home position sensor todetect the on condition after this fence starts moving to the home position.3) When the tray is set, the rear fence return sensor and the rear fence homeposition sensor are both on.Possible causes: _ Rear fence drive motor defective . _ Rear fence HP sensor defective _ Rear fence return sensor defective

Page 9: 7950

8/16/2019 7950

http://slidepdf.com/reader/full/7950 9/15

FT 7950/7960

9

SC510 - Abnormal tandem side fence home position detectionDefinition: [level: B]1) Both the rear side fence open sensor and the rear side fence close sensor 

are on.2) Both the front side fence open sensor and the front side fence close sensor are on.Possible cause: _ Rear side fence open sensor defective . _ Rear side fence close sensor defective _ Front side fence open sensor defective _ Front side fence close sensor defective

SC511 - Abnormal tandem side fence home position detection -stays onDefinition: [level: B]When the side fence goes back to the home position or the side fence drivemotor is closing the fence, the side fence positioning sensor stays on.Possible causes: _ Side fence drive motor defective . _ Side fence positioning sensor shorted

SC520 - Abnormal fusing/duplex drive motor movementDefinition: [level: D]The lock signal stays low for 1.0 second after the fusing/duplex drive motor starts.Possible causes: _ Fusing/duplex drive motor defective

 _ The cleaning roller is too dirty and applies an excessive load to thefusing/duplex drive motor.

SC522 - Abnormal jogger home position sensor detection - staysoff Definition: [level: B]When the jogger returns to the home position, the jogger home position sensor does not detect the on condition within 600 pulses.Possible causes: _ Jogger motor defective . _ Jogger HP sensor open

SC523 - Abnormal jogger home position sensor detection - stays

onDefinition: [level: B]The jogger home position sensor does not detect the off condition within 50pulses after its sensor detects the on condition in the initializing mode.Possible causes: _ Jogger drive motor defective . _ Jogger HP sensor shorted

Page 10: 7950

8/16/2019 7950

http://slidepdf.com/reader/full/7950 10/15

FT 7950/7960

10

SC541 – Fusing thermistor openDefinition: [level: A]The A/D conversion value of the fusing themistor voltage stays over 252

(detected temperature is lower than 3_C) for 10 seconds.Possible cause: _ Fusing thermistor open . _ Optics control board defective

SC542 – Start key stays redDefinition: [level: A]Before reaching the specified temperature for the ready condition, the fusingtemperature does not increase 5_C or more within 30 seconds.Possible cause: _ Fusing lamp defective . _ AC drive board defective . _ Fusing thermistor defective

SC543 - Fusing overheat (detected by the main control board)Definition: [level: A] A fusing temperature higher than 230_C is detected for 5 seconds.Possible cause: _ Fusing thermistor defective . _ Main control board defective

SC544 - Fusing overheat (detected by the optics control board)Definition: [level: A] A fusing temperature higher than 225_C is detected for 5 seconds.Possible cause: _ AC drive board defective . _ Optics control board defective _ Main control board defective . _ Poor cable connection

SC546 - Low fusing temperature (detected by the optics controlboard)Definition: [level: A]The fusing temperature stays lower than 100_C for 5 seconds after themachine becomes ready.Possible causes: _ Fusing thermistor defective . _ AC drive board defective _ Fusing lamp open . _ Main control board defective . _ Optics control board defective

SC547 - Fusing lamp continuously lit

Definition: [level: A] After the machine becomes ready, the fusing temperature does not increase5_C or more even though the fusing lamp fully lights for more than 30 seconds.Possible cause: _ Fusing lamp defective . _ AC drive board defective . _ Optics control board defective

Page 11: 7950

8/16/2019 7950

http://slidepdf.com/reader/full/7950 11/15

FT 7950/7960

11

SC548 - Unstable fusing temperatureDefinition: [level: A]If the fusing temperature changes by 20_C/second three times in 1 minute, this

SC is displayed.Possible causes: _ AC drive board defective . _ Thermistor defective

SC600 - Communication error (main control board and operationpanel)Definition: [level: D]The main control board does not communicate with the operation panel.Possible causes: _ Main control board defective . _ Operation panel defective _ Cable defective

SC601 - Communication error (main control board and opticscontrol board)Definition: [level: D]The main control board does not communicate with the optics control board.Possible causes: _ Main control board defective . _ Optics control board defective _ Cable defective

SC620 - Communication error (main control board and DJF mainboard)Definition: [level: C]The main board does not communicate with the DJF main board.Possible causes: _ Main control board defective . _ DJF main board defective _ Cable defective . _ Fiber optics defective

SC621 - Communication error (main control board and sorter staplers main board)Definition: [level: D]The main control board does not communicate with the sorter stapler mainboard.Possible causes: _ Main control board defective . _ Sorter stapler main board defective

 _ Cable defective . _ Fiber optics defectiveSC700 - Abnormal DJF feed-in motor movementSC701 - Abnormal DJF transport belt motor movementSC702 - Abnormal DJF feed out motor movementDefinition: [level: C]Encoder pulses are not detected by the DJF main board when the main motor is on. The first time, a jam occurs. The second time, the SC counter isincreased.Possible causes: _ DJF feed motor defective . _ DJF transport motor defective

Page 12: 7950

8/16/2019 7950

http://slidepdf.com/reader/full/7950 12/15

FT 7950/7960

12

 _ DJF feed out motor defective . _ DJF inverter motor defective

SC703 - Size detection encoder pulse defectiveDefinition: [level: C]

Pull-out roller in the registration section encoder pulses are not detected by theDJF main board. The first time, a jam occurs. The second time, the SC counter is incremented.Possible cause: _ Encoder defective . _ DJF main board defective

SC704 - Friction belt drive motor encoder pulse defectiveDefinition: [level: C]Friction belt drive motor encoder pulses are not detected by the DJF mainboard. The first time, a jam occurs. The second time, the SC counter isincremented.Possible cause: _ Encoder defective . _ DJF main board defective

SC730 - Abnormal main motor sorter stapler movement (sorter staplers)Definition: [level: D]When the encoder pulse is not detected by the SS main board for 200 ms after the main motor starts, a jam is indicated. If this occurs twice, an SC is displayed.Possible causes: _ SS main motor defective

SC731 - Abnormal bin drive (lift) motor movement (sorter staplers)Definition: [level: B (A821), D (A658)]1) If the wheel sensor (bin lift timing sensors) is not off 200 ms after the bindrive (lift) motor starts, jam “R2” is indicated.2) If the wheel sensor (bin lift timing sensors) is not on 200 ms after it turnedoff, jam “R2” is indicated. If any of these conditions occur twice, an SC occurs.Possible causes: _ Wheel sensor (bin lift timing sensors) defective . _ Bin drive (Lift) motor defective

SC735 - Abnormal jogger motor movement (sorter staplers)Definition: [level: B (A821), D (A658)]

1) When the jogger moves back to the home position, the jogger home positionsensor does not detect the on condition within 650 pulses. Then, a jam isindicated.2) When the jogger moves from the home position forward, and moves back tothe home position, the jogger home position sensor does not detect the off condition within 40 pulses or the sensor does not detect the on conditionwithin 60 pulses when it moves back. Then, a jam is indicated. If any of theseconditions occur twice, an SC occurs.Possible causes: _ Jogger motor defective . _ Jogger home position sensor defective

Page 13: 7950

8/16/2019 7950

http://slidepdf.com/reader/full/7950 13/15

FT 7950/7960

13

SC737 - Abnormal gripper motor movement (sorter staplers)Definition: [level: B (A821), D (A658)]1) When the gripper moves to the staple position, the gripper home position

sensor does not detect the on condition. Then a jam is indicated.2) When the gripper moves from the staple position to the bin position, thegripper home position sensor does not detect the on condition within 1,045pulses. Then a jam is indicated.3) When the gripper moves to the home position, the gripper home positionsensor does not detect the on condition within 1,250 pulses. Then a jam isindicated.4) When the gripper moves from the home position forward, and moves back tothe home position, the gripper home position sensor does not detect the off condition within 200 pulses or the sensor does not detect the on conditionwithin 220 pulses when the gripper moves back. Then a jam is indicated.

If any of these conditions occur twice, an SC occurs.Possible causes: _ Gripper motor defective . _ Gripper home position sensor defective

SC738 - Abnormal staple motor movement (sorter staplers)Definition: [level: B]The staple home position sensor does not detect the off condition within 150ms after the motor starts, or does not detect the on condition within 600 ms.Then a jam is indicated. If this occurs twice, this SC is displayed.Possible causes: _ Staple unit (staple motor) defective . _ A staple is jammed in the staple unit.

SC740 - Abnormal staple unit drive motor movement (sorter stapler)Definition: [level: B]1) When the staple unit has moved from the home position to the stapleposition, the stapler unit home position sensor is on. A jam is indicated.2) The staple unit home position sensor does not detect the off condition (within1640 pulses) when the staple unit moves to the home position. A jam isindicated.3) The staple unit home position sensor does not detect the off condition (within120 pulses) when the staple unit moves forward from the home position or does not detect the on condition within 160 pulses when it moves back to the

home position. A jam is indicated. If any of these conditions occur twice, an SCoccurs.Possible causes: _ Staple unit drive motor defective . _ Staple unit home position sensor defective

SC741 - Abnormal bin rear plate motor movement (A821 sorter stapler only)Definition: [level: B]1) When the rear bin plate is open, the bin rear plate open sensor does notdetect the on condition for 750 ms or more after the motor starts. Then a jamis indicated.

Page 14: 7950

8/16/2019 7950

http://slidepdf.com/reader/full/7950 14/15

FT 7950/7960

14

2) When the rear bin plate is closed, the bin rear plate home position sensor does not detect the on condition for 750 ms or more after the motor starts.Then a jam is indicated.

3) In the initial condition, the bin rear plate open sensor does not detect the oncondition for 1.25 seconds or more after the motor starts. Then a jam isindicated. If any of these conditions occur twice, an SC occurs.Possible causes: _ Bin rear plate drive motor defective . _ Bin rear plate open sensor defective _ Bin rear plate home position sensor defective

SC743 - Punch motor abnormal (sorter stapler with punch)Definition: [level: B]1) After turning on the main switch, the punch home position sensor is notactivated within 1,100 pulses. Then an R2 jam is indicated.2) In punch mode, the punch home position sensor is not activated within 950

pulses after starting the punch motor. Then an R2 jam is indicated. If any of these conditions occur twice, an SC occurs.Possible causes: _ Punch motor . _ Punch home position sensor 

SC744 - Staple jam release abnormal (A821 sorter stapler only)Definition: [level B]In the initial condition, the paper sensor is activated and the staple home positionsensor is de-activated. Then, an R3 (staple) jam is indicated. If this conditionoccurs 4 times in a row, this SC is displayed.Possible causes:

 _ Stapler SC745 - Grip unit motor abnormal (A821 sorter stapler)Definition: [level: B]1) When the grip unit has moved to the staple position, the grip unit homeposition sensor is on. Then an R2 jam is indicated.2) When the grip unit returns from the staple position to the home position, thegrip unit home position sensor does not turn on within 1070 pulses. Then anR2 jam is indicated.3) When the grip unit moves from the home position forward, and moves backto the home position, the grip unit home position sensor does not turn off within 350 pulses. Then an R2 jam is indicated. If any of these conditions occur 

twice, an SC occurs.Possible cause: _ Grip unit home position sensor defective . _ Grip unit motor defective

SC900 - Total counter failure (staying in the on condition)Definition: [level: D]The mechanical total counter stays in the on condition.Possible causes: _ Total counter defective . _ Main control board defective

Page 15: 7950

8/16/2019 7950

http://slidepdf.com/reader/full/7950 15/15

FT 7950/7960

15

SC901 - Total counter failure (staying in the off condition)Definition: [level: D]The mechanical total counter stays in the off condition.

Possible causes: _ Total counter defective

SC902 - Electrical counter abnormalDefinition: [level: A]The contents of the electrical counter are abnormal.Possible cause: _ RAM board defective

SC - Full used toner bottleDefinition: [level: A]The toner overflow switch is activated.Possible causes: _ Toner collection bottle full . _ Toner overflow switch defective

SC940 - Main switch abnormalDefinition: [level: A]DC5V does not drop under 4.2 V within 3 seconds after the main switch isturned off.Possible causes: _ Main switch defective _ Main control board defective