a summary on polarisation in run-12 100gev and first results for 250 gev
DESCRIPTION
A summary on Polarisation in Run-12 100GeV and first results for 250 geV. E.C. Aschenauer presenting the work done by Alan, anders , Bill and Dima. Run 12 p C polarimeters. Run 12 p C polarimeters. Known complications: 100 GeV : - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: A summary on Polarisation in Run-12 100GeV and first results for 250 geV](https://reader036.vdocuments.pub/reader036/viewer/2022062517/56812ca5550346895d914d74/html5/thumbnails/1.jpg)
A SUMMARY ON POLARISATION IN RUN-12100GEV AND FIRST RESULTS FOR 250 GEV
E.C. ASCHENAUERPRESENTING THE WORK DONE BY ALAN,
ANDERS, BILL AND DIMA
![Page 2: A summary on Polarisation in Run-12 100GeV and first results for 250 geV](https://reader036.vdocuments.pub/reader036/viewer/2022062517/56812ca5550346895d914d74/html5/thumbnails/2.jpg)
STAR Spin PWG 2012/03/22 2
RUN 12 pC POLARIMETERS
E.C. Aschenauer
![Page 3: A summary on Polarisation in Run-12 100GeV and first results for 250 geV](https://reader036.vdocuments.pub/reader036/viewer/2022062517/56812ca5550346895d914d74/html5/thumbnails/3.jpg)
STAR Spin PWG 2012/03/22 3
RUN 12 pC POLARIMETERS
Known complications: 100 GeV:
o noise due to pickup especially at injection less significant at flat top method to correct for it was developed by Dima and Bill and
implemented shown data have this correction included noise was correlated to stochastic cooling sitting before / after
the polarimeterso B2D is a test polarimeter new detector types
255 GeVo noise is gone most likely due to grounding improvements
and removing of antennas at the polarimeters and the stochastic cooling
o polarimeters not yet normalized to jet, need 10 long fills at least normalization is polarimeter dependent ratios like Y1D to Y2U need not to be 1 at the moment
E.C. Aschenauer
![Page 4: A summary on Polarisation in Run-12 100GeV and first results for 250 geV](https://reader036.vdocuments.pub/reader036/viewer/2022062517/56812ca5550346895d914d74/html5/thumbnails/4.jpg)
STAR Spin PWG 2012/03/22 4
255 GEV RESULTS
polarisation at injectionBlue and Yellow
Caveat:pC numbers not normalized to jet
E.C. Aschenauer
![Page 5: A summary on Polarisation in Run-12 100GeV and first results for 250 geV](https://reader036.vdocuments.pub/reader036/viewer/2022062517/56812ca5550346895d914d74/html5/thumbnails/5.jpg)
STAR Spin PWG 2012/03/22 5
255 GEV RESULTS
E.C. Aschenauer
polarisation at flat topBlue and Yellow
H-Jet
longitudinalH-Jet Run-11
![Page 6: A summary on Polarisation in Run-12 100GeV and first results for 250 geV](https://reader036.vdocuments.pub/reader036/viewer/2022062517/56812ca5550346895d914d74/html5/thumbnails/6.jpg)
STAR Spin PWG 2012/03/22 6
255 GEV RESULTS
E.C. Aschenauer
0.9%±0.11/hour0.62%±0.13/hour
Run-110.39%±0.07/hour
Run-110.78%±0.07/hour
Polarisation lifetime very similar run-11 and run-12 so 255 GeV did notdo the trick
![Page 7: A summary on Polarisation in Run-12 100GeV and first results for 250 geV](https://reader036.vdocuments.pub/reader036/viewer/2022062517/56812ca5550346895d914d74/html5/thumbnails/7.jpg)
STAR Spin PWG 2012/03/22 7
255 GEV RESULTS
E.C. Aschenauer
1.288%±0.18/hour0.71%±0.28/hour
H-Jet:Fills: 16570-16592trans + longitudinal
H-Jet:Fills: 16586-16592longitudinal
![Page 8: A summary on Polarisation in Run-12 100GeV and first results for 250 geV](https://reader036.vdocuments.pub/reader036/viewer/2022062517/56812ca5550346895d914d74/html5/thumbnails/8.jpg)
STAR Spin PWG 2012/03/22 8
255 GEV RESULTS TRANSVERSE FILLS
E.C. Aschenauer
1.4%±0.21/hour0.10%±0.23/hour Polarisation lifetime inyellow very similar to longitudinal 255 GeV fills
![Page 9: A summary on Polarisation in Run-12 100GeV and first results for 250 geV](https://reader036.vdocuments.pub/reader036/viewer/2022062517/56812ca5550346895d914d74/html5/thumbnails/9.jpg)
~Lstore avg Goal
HISTORY
![Page 10: A summary on Polarisation in Run-12 100GeV and first results for 250 geV](https://reader036.vdocuments.pub/reader036/viewer/2022062517/56812ca5550346895d914d74/html5/thumbnails/10.jpg)
INTENSITY DEPENDENCE OF POLARISATION
transverse
longitudinal
longitudinal
![Page 11: A summary on Polarisation in Run-12 100GeV and first results for 250 geV](https://reader036.vdocuments.pub/reader036/viewer/2022062517/56812ca5550346895d914d74/html5/thumbnails/11.jpg)
STAR Spin PWG 2012/03/22 11
POLARISATION LOSS THROUGH ROTATOR RAMP
E.C. Aschenauer
Shown are the polarisationmeasurements before and after the rotator ramp at 255 GeV
Blue Beam
Yellow Beam
![Page 12: A summary on Polarisation in Run-12 100GeV and first results for 250 geV](https://reader036.vdocuments.pub/reader036/viewer/2022062517/56812ca5550346895d914d74/html5/thumbnails/12.jpg)
STAR Spin PWG 2012/03/22 12
100 GEV RESULTS
E.C. Aschenauer
polarisation at injectionBlue and Yellow
Caveat:only first round of cleaningup noise in polarimeters was done
pC numbers not normalized to jet
![Page 13: A summary on Polarisation in Run-12 100GeV and first results for 250 geV](https://reader036.vdocuments.pub/reader036/viewer/2022062517/56812ca5550346895d914d74/html5/thumbnails/13.jpg)
STAR Spin PWG 2012/03/22 13
polarisation at flat topBlue and Yellow
100 GEV RESULTS
H-JET
E.C. Aschenauer
![Page 14: A summary on Polarisation in Run-12 100GeV and first results for 250 geV](https://reader036.vdocuments.pub/reader036/viewer/2022062517/56812ca5550346895d914d74/html5/thumbnails/14.jpg)
STAR Spin PWG 2012/03/22 14E.C. Aschenauer
0.47%±0.040/hour 0.97%±0.047/hour
![Page 15: A summary on Polarisation in Run-12 100GeV and first results for 250 geV](https://reader036.vdocuments.pub/reader036/viewer/2022062517/56812ca5550346895d914d74/html5/thumbnails/15.jpg)
STAR Spin PWG 2012/03/22 15E.C. Aschenauer
0.46%±0.11/hour0.80%±0.11/hour
H-JetFills: 16386-16439
![Page 16: A summary on Polarisation in Run-12 100GeV and first results for 250 geV](https://reader036.vdocuments.pub/reader036/viewer/2022062517/56812ca5550346895d914d74/html5/thumbnails/16.jpg)
STAR Spin PWG 2012/03/22 16E.C. Aschenauer
0.90%±0.095/hour0.42%±0.08/hour
![Page 17: A summary on Polarisation in Run-12 100GeV and first results for 250 geV](https://reader036.vdocuments.pub/reader036/viewer/2022062517/56812ca5550346895d914d74/html5/thumbnails/17.jpg)
STAR Spin PWG 2012/03/22 17E.C. Aschenauer
1.85%±0.13/hour0.41%±0.07/hour
![Page 18: A summary on Polarisation in Run-12 100GeV and first results for 250 geV](https://reader036.vdocuments.pub/reader036/viewer/2022062517/56812ca5550346895d914d74/html5/thumbnails/18.jpg)
STAR Spin PWG 2012/03/22 18E.C. Aschenauer
1.77%±0.17/hour0.18%±0.118/hour
H-JetFills: 16502-16511
![Page 19: A summary on Polarisation in Run-12 100GeV and first results for 250 geV](https://reader036.vdocuments.pub/reader036/viewer/2022062517/56812ca5550346895d914d74/html5/thumbnails/19.jpg)
STAR Spin PWG 2012/03/22 19E.C. Aschenauer
0.76%±0.08/hour0.35%±0.11/hour
![Page 20: A summary on Polarisation in Run-12 100GeV and first results for 250 geV](https://reader036.vdocuments.pub/reader036/viewer/2022062517/56812ca5550346895d914d74/html5/thumbnails/20.jpg)
STAR Spin PWG 2012/03/22 20
SUMMARY
100 GeV: main loss in polarisation through decay in fill polarisation decay varies from week to week for the two
beams jet and pC polarimeters consistent observing the same
trends
255 GeV: the polarisation loss through decay in fill and on the
ramp jet and pC polarimeters consistent observing the same
trends observed polarisation consistent with 2011 average polarisation decay in fill “comparable” to 2011
E.C. Aschenauer