aa-en-j02.350.4a-gmv_z3

3
J.02 Air conditioning and heatpumps GMV-Z3 Gree Digital Multi VRF with Heat Recovery Heatpump Indoor unit, floor/ceiling type www.airtradecentre.com VRF floor/ceiling indoor unit type GMV-Z3 Floor/ceiling VRF indoor unit wired or infrared remote control Product Indoor unit, floor/ceiling model Application Cooling or heating of office rooms, living rooms, apartments, workshops,... For area's between 60 and 350 m³ Function Heatpump, INVERTER Refrigerant R410A Features Ideal for shop, restaurant etc where there is no false ceiling Ultra quiet operation Compact and light weight Detachable and washable grill Long life and washable filter Wired remote control Infrared remote control Applicable outdoor units Individual outdoor units: Type GMV-Rh200W2/Na-M Type GMV-Rh250W2/Na-M Type GMV-Rh300W2/Na-M Applicable controller Wired controller Operating mode display (Cool, Dry, Fan, Heat) On/Off button Sleep mode display 10 Timer button Environmental temp. display / Malfunction display Swing button Fan control display (automatic, high, media, low) Swing display Set Temp. display J.02 GMV-Z3 1/3 - 2011/3/21 - AA-EN

Upload: dinop

Post on 23-Apr-2017

213 views

Category:

Documents


0 download

TRANSCRIPT

J.02

Air conditioningand heatpumps

GMV-Z3

GreeDigital Multi VRF with HeatRecoveryHeatpumpIndoor unit, floor/ceilingtype

www.airtradecentre.com

VRF floor/ceiling indoor unit typeGMV-Z3Floor/ceiling VRF indoor unit wired or infrared remote control

Product¾ Indoor unit, floor/ceiling model

Application¾ Cooling or heating of office rooms, living rooms, apartments, workshops,...¾ For area's between 60 and 350 m³

Function¾ Heatpump, INVERTER

Refrigerant¾ R410A

Features¾ Ideal for shop, restaurant etc where there is no false ceiling¾ Ultra quiet operation¾ Compact and light weight¾ Detachable and washable grill¾ Long life and washable filter¾ Wired remote control¾ Infrared remote control

Applicable outdoor unitsIndividual outdoor units:¾ Type GMV-Rh200W2/Na-M¾ Type GMV-Rh250W2/Na-M¾ Type GMV-Rh300W2/Na-M 

Applicable controllerWired controller¾ Operating mode display (Cool, Dry, Fan, Heat)¾ On/Off button¾ Sleep mode display  10  Timer button¾ Environmental temp. display / Malfunction display¾ Swing button¾ Fan control display (automatic, high, media, low)¾ Swing display¾ Set Temp. display

J.02 GMV-Z3 1/3 - 2011/3/21 - AA-EN

¾ Fan control button¾ Defrosting display¾ Temp. / Timer reducing button¾ Timer display¾ Temp. / Timer rising button¾ Signal receptor¾ Mode button Remote controller

¾ Operating mode display (Cool, Dry, Fan, Heat)¾ On/Off button¾ Sleep mode display¾ Timer button¾ Swing button¾ Fan control display (automatic, high, media, low)¾ Swing display¾ Set Temp. display¾ Fan control button¾ Defrosting display¾ Temp. / Timer reducing button¾ Timer display¾ Temp. / Timer rising button¾ Mode button

Order exampleGMV-Rh36Zd/Na-K ¾ GMV-Rh..Zd/Na-K = Type of VRF indoor unit¾ 36 = 3,6 kW cooling capacity

Specifications

Model

CapacityPower supply

Power Air volumeNoise

Connections WeightMotor output power Liquid Gas

Cooling Heating Standard[kW] [W] [m³/h] [dB(A)] ["] [kg]

GMV-Rh28Zd/Na-K 2.80 3.20

220-240V - 50Hz - 1Ph

10 550 43 1/4 3/8 26GMV-Rh36Zd/Na-K 3.60 4 10 600 44 1/4 1/2 26GMV-Rh50Zd/Na-K 5 5.80 40 700 50 1/4 1/2 27GMV-Rh71Zd/Na-K 7.10 8 100 1170 48 3/8 5/8 32GMV-Rh90Zd/Na-K 9 10 150 2100 51 3/8 5/8 48

GMV-Rh112Zd/Na-K 11.20 12.50 180 2200 54 3/8 5/8 48GMV-Rh125Zd/Na-K 12.50 13.50 180 2300 55 3/8 5/8 48

DimensionsA [mm] B [mm] C [mm] D [mm] E [mm]

GMV-Rh28Zd/Na-K 840 695 238 745 260GMV-Rh36Zd/Na-K 840 695 238 745 260GMV-Rh50Zd/Na-K 840 695 238 745 260GMV-Rh71Zd/Na-K 1220 600 188 1220 260GMV-Rh90Zd/Na-K 1500 695 238 1500 260GMV-Rh112Zd/Na-K 1500 695 238 1500 260GMV-Rh125Zd/Na-K 1500 695 238 1500 260

J.02

Air conditioningand heatpumps

www.airtradecentre.comJ.02 GMV-Z3 2/3 - 2011/3/21 - AA-EN

A

B

CD

E

J.02

Air conditioningand heatpumps

www.airtradecentre.comJ.02 GMV-Z3 3/3 - 2011/3/21 - AA-EN