Diatron MI PLC Papírgyár u. 58-59. H-1038 Budapest, HUNGARY Phone: (36-1) 436 9800, fax: (36-1) 436 9809 www.diatron.com E-mail: [email protected] Abacus 5 * Diatron reserves the right to change any of the specificaons without prior noce. ** Usage of original Diatron reagents is recommended Full specificaons are available on request or can be obtained from www.diatron.com (select ”products”.) Parameters CBC+5 DIFF mode (24 parameters) - 2 histograms: RBC, PLT; 2 scaergrams: 4 diff , BASO WBC, LYM, MON, NEU, EOS, BAS, LYM%, MON%, NEU%, EOS%, BAS%, RBC, HCT, MCV, RDW (sd/cv), HGB, MCH, MCHC, PLT, PCT, MPV, PDW (sd/cv) Technology Laser light scaer technology for 5-part WBC differenal Impedance method for CBC: WBC (80 μm), RBC and PLT (70 μm) Light absorbance for HGB measurement Cyanide-free reagent system Throughput Up to 60 tests/hour Sample volume 100 μl (open/closed, whole blood) Sampling method Closed and open tube sampling, auto-sampler (oponal) Calibraon Stat & Rack mode, specific control material (external reference – oponal) Quality Control Separate QC database, Levey-Jennings Charts Mul user mode Mullevel user modes with individual idenficaon (username, password) User interface 600x800 color graphics LCD, touch screen (10.4”) User languages Mullingual user interface Soware upgrade Via USB port (USB memory sck) Data storage capacity 100.000 records Printout External, Microso ® Windows TM compable printers External keyboard PS/2 or USB Interfacing capabilies RS232, USB (4 pcs), Ethernet Size (W x H x D) 40 x 50 x 45 cm Weight 35 kg, with auto-sampler 45 kg Operang environment Temperature: 15–35 °C Relave humidity: max 80% (non-condensing) Autoloader Sample capacity 100 tubes: 10 racks with 10 sample tubes each Acceptable primary tubes Monovee®, Vacutainer®, Vacuee® Other features Built-in bar code reader Built-in sample mixer Cap recognion (only tubes with caps are mixed and processed) Reagents** Diatro Dil-Diff (D50) Diluent Diatro Lyse-5P Lysing reagent for quantave and qualitave determinaon of WBC, and HGB concentraon Diatro Diff-5P Lysing reagent for quantave determinaon of WBC, leukocyte five-part differenaon (LYM, MON, NEU, EOS, BAS) and hemoglobin (HGB) concentraon Diatro Hypoclean CC External cleaner for removing blood component precipitates from capillaries, tubings and chambers Abacus 5 Innovave Soluons in Hematology Your distributor: Abacus 5 Abacus 5

Upload: draknith

Post on 28-Aug-2014

47 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Abacus 5 - Presentation

Diatron MI PLCPapírgyár u. 58-59.

H-1038 Budapest, HUNGARY

Phone: (36-1) 436 9800, fax: (36-1) 436 9809www.diatron.com

E-mail: [email protected]

Abacus 5

* Diatron reserves the right to change any of the specifi ca� ons without prior no� ce. ** Usage of original Diatron reagents is recommendedFull specifi ca� ons are available on request or can be obtained from www.diatron.com (select ”products”.)

Parameters CBC+5 DIFF mode (24 parameters) - 2 histograms: RBC, PLT;

2 sca� ergrams: 4 diff , BASO

WBC, LYM, MON, NEU, EOS, BAS, LYM%, MON%, NEU%, EOS%, BAS%,

RBC, HCT, MCV, RDW (sd/cv), HGB, MCH, MCHC,

PLT, PCT, MPV, PDW (sd/cv)

Technology Laser light sca� er technology for 5-part WBC diff eren� al

Impedance method for CBC: WBC (80 μm), RBC and PLT (70 μm)

Light absorbance for HGB measurement

Cyanide-free reagent system

Throughput Up to 60 tests/hour

Sample volume 100 μl (open/closed, whole blood)

Sampling method Closed and open tube sampling, auto-sampler (op� onal)

Calibra� on Stat & Rack mode, specifi c control material

(external reference – op� onal)

Quality Control Separate QC database, Levey-Jennings Charts

Mul� user mode Mul� level user modes with individual iden� fi ca� on (username, password)

User interface 600x800 color graphics LCD, touch screen (10.4”)

User languages Mul� lingual user interface

So� ware upgrade Via USB port (USB memory s� ck)

Data storage capacity 100.000 records

Printout External, Microso� ® WindowsTM compa� ble printers

External keyboard PS/2 or USB

Interfacing capabili� es RS232, USB (4 pcs), Ethernet

Size (W x H x D) 40 x 50 x 45 cm

Weight 35 kg, with auto-sampler 45 kg

Opera� ng environment Temperature: 15–35 °C

Rela� ve humidity: max 80% (non-condensing)

Autoloader

Sample capacity 100 tubes: 10 racks with 10 sample tubes each

Acceptable primary tubes Monove� e®, Vacutainer®, Vacue� e®

Other features Built-in bar code reader

Built-in sample mixer

Cap recogni� on (only tubes with caps are mixed and processed)

Reagents**

Diatro Dil-Diff (D50) Diluent

Diatro Lyse-5P Lysing reagent for quan� ta� ve and qualita� ve determina� on of WBC, and HGB concentra� on

Diatro Diff -5P Lysing reagent for quan� ta� ve determina� on of WBC, leukocyte fi ve-part diff eren� a� on

(LYM, MON, NEU, EOS, BAS) and hemoglobin (HGB) concentra� on

Diatro Hypoclean CC External cleaner for removing blood component precipitates from capillaries, tubings and chambers

Abacus 5

Innova� ve Solu� ons in Hematology Your distributor: Ab

acus

5Ab

acus

5

Page 2: Abacus 5 - Presentation

is one of the high-end models of Diatron’s range of Hematology Analyzers.Its patented laser-based op� cal measurement technology was developed by Diatron.It guarantees precise and accurate 5 part diff eren� al results for human samples, and provides maximum value at low running costs.

Abacus 5

Ease of use

• The instrument features an easy-to-use, logically constructed mul� lingual opera� ng menu

• Embedded so� ware enables easy connec� on to a computer

• Windows® compa� ble printers are supported

• Closed and open tube sampling method

• Autoloader can be added at any � me

• Integrated bar code reader for rapid data processing

Abacus 5

High performance

• Complete 24 parameter CBC profi le including the op� cal determina� on of the 5 part WBC diff eren� al count

• 60 samples per hour throughput (both in Stat & Rack mode)

• Large color touch-screen, allowing fast and effi cient work. Results are analyzed on 2 histograms and 2 sca� ergrams

• More than 100.000 results database capacity

• 4 USB ports

Reliable and effi cient

• The long life� me laser diode ensures op� mal performance using a high-tech fl ow cuve� e

• Abacus 5 requires minimal maintenance and so minimizes opera� onal disrup� on

• Its compact size makes it suitable for laboratories with low desktop space

• Diagnos� c fl agging system • Uses only 3 reagents• Walk-away system• Autoloader with a capacity of 100 vials• Cap recogni� on mechanism to avoid sampling errors