accesorios para adss-preformed
DESCRIPTION
Catalogo de Accesorios para ADSSTRANSCRIPT
![Page 1: Accesorios Para ADSS-Preformed](https://reader031.vdocuments.pub/reader031/viewer/2022020518/577c80c61a28abe054aa1f4d/html5/thumbnails/1.jpg)
Section 6 — Page 79
PREFORMED LINE PRODUCTSFIBERLIGN® Lite Tension Dead-end for ADSS
Nomenclature:1. LOOP LENGTH: Length from the color mark to the
end of the loop.
2. LOOP DIAMETER: The loop has a formed diameterdesigned to interface with standard fittings
3. COLOR MARK: The dead-end color mark or cross-over mark locates the beginning of dead-end con-tact with the cable during installation. It is used foridentification as well.
4. DEAD-END LEGS: The legs wrap onto the cablebeginning at the crossover mark.
5. FLARED ROD ENDS: Special rod end treatment toprevent jacket damage.
6. LATEX COATING: Pliable coating applied overthe dead-end legs.
7. PRODUCT ID TAG: Red Tag includes productdescription and application information.
8. PITCH LENGTH: The distance along the leg thatrepresents one complete wrap of the formed helixaround the circumference of the cable (360 de-grees).
FIBERLIGN® Lite Tension Dead-end for All Dielectric
Self-Supporting (ADSS) Fiber Optic Cable
Installed
Application:
The FIBERLIGN Lite Tension Dead-end is a dielec-tric dead-end designed to terminate short span, lowtension ADSS fiber optic cables in low voltage envi-ronments. Unlike the Limited, Medium, and HighTension FIBERLIGN® Dielectric Dead-end designsfound later in this section, the Lite Tension Dead-endis reduced to a single layer component that offers aneconomical solution for very light loads. The producteffectively transfers the low axial load on the cable atthe end of the dead-end legs to low uniform radialcompression near the dead-end loop.
SUPERIOR FATIGUE STRENGTH: The small diam-eter wires that comprise each dead-end are a mixtureof aluminum and aluminum clad steel to assure longterm performance.
1.3.
8.
2. 7.
6.
4.
5.
![Page 2: Accesorios Para ADSS-Preformed](https://reader031.vdocuments.pub/reader031/viewer/2022020518/577c80c61a28abe054aa1f4d/html5/thumbnails/2.jpg)
Section 6 — Page 80
PREFORMED LINE PRODUCTSFIBERLIGN® Lite Tension Dead-end for ADSS
Dead-end performance depends upon a number offactors including cable brand and design, tensionload requirements, temperature and environmentaloperating conditions among others.
The FIBERLIGN Lite Tension Dead-end has a pli-able latex coating and flared rod end treatment thatavoids possible damage to the cable jacket duringand after installation.
ATTACHING TO THE STRUCTURE: The loopdiameter of the Lite Tension Dead-end will fit over aminimum diameter of 1.5" (38mm) and a maximumdiameter of 2-1/4" (57 mm). The Lite Tension Dead-end is designed to accept common guy wire dead-end pole fittings like thimble eyes and guy hooks.
Appropriate Fittings
The extended loop of the dead-end reduces theneed for an extension link; however, PLP can provideother FIBERLIGN® fittings including extension links(with thimble clevis) if desired. PLP offers the TC-5AThimble Clevis, Thimble Eye, and LCE-55-14 Exten-sion Link.
In general, Lite Tension Dead-ends are in-tended for use with these conditions andlimitations:• Light Tensions, approximately:
-600# (2.7 kN) maximum initial (stringing/nominal axial/long-term) tension-800# (3.5 kN) maximum loaded (working/loaded axial/short- term) tension
• Short Spans:-300' (91 m) maximum spans-not recommended for critical crossing spans(highways, rivers, etc.) see Medium or HighTension Dead-ends
• Very low strength cables• "Standard" jackets• Most cable brands• No excessive operating conditions, cable
motion or high temperatures
Lite Tension Dead-end features:• Standard design parameters• Broad cable OD ranges, listed on ID tags• Economical single component design• Optimized compact length• Fast easy installation• Accepts standard pole line fittings• Latex coated with flared rod ends• Uniform pressure design• Superior fatigue strength wire design
*golataCrebmuN
egnaRretemaiDelbaCedoCroloC
htgneLllarevO
)ni(niM )ni(xaM )mm(niM )mm(xaM sehcni retem
1005782 573. 414. 01 11 deR 82 17.
2005782 514. 954. 11 21 egnarO 13 97.
3005782 064. 505. 21 31 neerG 33 48.
4005782 605. 755. 31 41 kniP 73 49.
5005782 855. 516. 41 61 wolleY 24 70.1
6005782 616. 086. 61 71 eulB 54 41.1
7005782 186. 057. 71 91 nworB 94 42.1
tundnatlobm61ro"8/5htiwtnuoM-rebmuN)5-ET.oN.taC(eyEelbmihTedulcniotETedocxiffusddA*
ThimbleClevis
GuyHook
ThimbleEye
![Page 3: Accesorios Para ADSS-Preformed](https://reader031.vdocuments.pub/reader031/viewer/2022020518/577c80c61a28abe054aa1f4d/html5/thumbnails/3.jpg)
Section 6 — Page 81
PREFORMED LINE PRODUCTSFIBERLIGN® Dielectric Dead-end for ADSS
FIBERLIGN Dielectric Dead-endinstalled
General Information:The FIBERLIGN Dielectric Dead-end product line
has been designed to securely but gently terminateAll Dielectric Self-Supporting (ADSS) aerial fiberoptic cable. A two component design consisting ofappropriate size and length of Structural ReinforcingRods and dead-end component is required to trans-fer axial tensile loads and distribute radial compres-sive forces through the plastic jacket and onto theinternal strength members without damaging thefragile plastic jacket or internal optical fibers.
Application & Product Selection:Specific dead-end design and performance de-
pends upon a number of factors such as cable brandand design, strength member construction, jackettype, tension load requirements, temperature andenvironmental operating conditions, and so on. Dueto these factors, three types of dead-ends are of-fered:
• Limited Tension Dielectric Dead-ends• Medium Tension Dielectric Dead-ends• High Tension Dielectric Dead-ends
Limited Tension Dead-ends:Intended for relatively low tension application usu-
ally associated with short span construction. Theyare not cable or line design specific but are designedto fit broad diameter ranges. Holding performancewill vary by specific cable brand and operating con-ditions. Therefore, no specific holding strength rat-ing is possible.
In general, Limited Tension Dead-ends are in-tended for use with these conditions and limitations:• Low tensions, approximately:
-1,000# (4.4kN) maximum initial (stringing/nominal axial/long-term) tension -2,500# (11.1 kN)maximum loaded (working/loaded axial/short-term) tension
• Short spans:-300' - 600' (91-183 m) typical maximum spansdepending upon cable OD and tensions-not recommended for critical crossing spans(highways, rivers, etc.); see Medium or HighTension Dead-ends
• Low strength cables• “Standard” jackets• Most cable brands• No excessive operating conditions, cable motion
or high temperatures
Nomenclature
Dead-end ComponentCrossover marks
Structural Reinforcing Rod Component
5/8" Eyenut
TC-5F or TC-5A Thimble
Clevis
14" Extension Link
ID tag
ID tag
![Page 4: Accesorios Para ADSS-Preformed](https://reader031.vdocuments.pub/reader031/viewer/2022020518/577c80c61a28abe054aa1f4d/html5/thumbnails/4.jpg)
Section 6 — Page 82
PREFORMED LINE PRODUCTSFIBERLIGN® Dielectric Dead-end for ADSS
Limited Tension Dead-ends:
(continued)Limited Tension Dead-end features:• Standard design parameters• Broad cable OD ranges, listed on ID tags• Short Structural Reinforcing Rods• Short dead-end component• Structural Reinforcing Rods and Dead-end
components packaged in same carton.• Fast, easy installation• Utilizes economical TC-5A Thimble Clevis
Medium Tension Dead-ends:Designed for medium tension applications. Hold-
ing performance will vary by specific cable brand
*To include accessories in same carton, add suffix code(s) toDead-end catalog number. Example: Cat. No. 2872001C1E1includes Dead-end #2872001, TC-5F Thimble Clevis and Ex-tension Link #71002366 in the same carton. See DielectricDead-end accessories in this section.
CAUTION: Some ADSS cables are not suitable for use withLimited Tension Dead-ends. Limited Tension Dead-ends are notrecommended for track-resistant jacket applications. Consult PLPfor specifics.
sdne-daeDnoisneTdetimiL
golataC*rebmuN
.D.OelbaCegnaR)hcni(
.D.OelbaCegnaR)mm(
llarevOhtgneL)m(.ni
roloCedoC
1002782 424.-004. 11-01 )2.1(84 kcalB
2002782 154.-524. 11-11 )2.1(84 wolleY
3002782 184.-254. 21-21 )2.1(84 neerG
4002782 015.-284. 31-21 )2.1(84 egnarO
5002782 245.-115. 41-31 )2.1(84 eulB
6002782 775.-345. 51-41 )2.1(84 etihW
7002782 316.-875. 61-51 )2.1(84 deR
8002782 156.-416. 71-61 )2.1(84 kcalB
9002782 296.-256. 81-71 )2.1(84 wolleY
0102782 737.-396. 91-81 )2.1(84 neerG
1102782 487.-837. 02-91 )2.1(84 egnarO
2102782 438.-587. 12-02 )2.1(84 eulB
3102782 988.-538. 32-12 )2.1(84 etihW
4102782 549.-098. 42-32 )2.1(84 deR
5102782 700.1-649. 62-42 )2.1(84 kcalB
6102782 370.1-800.1 72-62 )5.1(06 wolleY
7102782 041.1-470.1 92-72 )5.1(06 neerG
8102782 212.1-141.1 13-92 )5.1(06 egnarO
9102782 882.1-312.1 33-13 )5.1(06 eulB
sdne-daeDnoisneTmuideM
golataCrebmuN
.D.OelbaCegnaR)hcni(
.D.OelbaCegnaR)mm(
llarevOhtgneL)m(.ni
roloCedoC
0012782 015.-284. 31-21 )2.2(58 egnarO
1012782 245.-115. 41-31 )2.2(58 eulB
2012782 775.-345. 51-41 )2.2(58 etihW
3012782 316.-875. 61-51 )2.2(58 deR
4012782 156.-416. 71-61 )2.2(58 kcalB
5012782 296.-256. 81-71 )2.2(58 wolleY
6012782 737.-396. 91-81 )2.2(58 neerG
7012782 487.-837. 02-91 )2.2(58 egnarO
8012782 438.-587. 12-02 )3.2(09 eulB
9012782 988.-538. 32-12 )3.2(09 etihW
0112782 549.-098. 42-32 )4.2(59 deR
1112782 700.1-649. 62-42 )4.2(59 kcalB
2112782 370.1-800.1 72-62 )5.2(79 elpruP
3112782 041.1-470.1 92-72 )5.2(001 kniP
4112782 212.1-141.1 13-92 )6.2(301 nworB
5112782 882.1-312.1 33-13 )7.2(501 egnarO
and operating conditions; therefore no, specific hold-ing rating is possible.
In general, Medium Tension Dead-ends are intendedfor use with these conditions:• Moderate tensions, approximately
-2,000# (8.9 kN) maximum initial (everyday/stringing) tension -4,000# (17.8 kN) maximum loaded(short-term/working) tension maximum spanlength is dependent on cable O.D. and tensions
• For “standard” and most “track-resistant” jackettypes of ADSS cables. (Contact PLP to verify ac-ceptable track-resistant cable.)
• For severe operating temperatures and conditions• Structural Reinforcing Rod length ranges from 85"
to 105" (2.2 m — 2.7 m)
Medium Tension Dead-end features:• Standard design parameters• Broad cable OD ranges, listed on ID tags• Moderate length• Structural Reinforcing Rods and Dead-end
components packaged in same carton• Utilize TC-5F (or TC-6F) Thimble Clevis• Accessories can be ordered with Dead-end com-
ponents using suffix codes
![Page 5: Accesorios Para ADSS-Preformed](https://reader031.vdocuments.pub/reader031/viewer/2022020518/577c80c61a28abe054aa1f4d/html5/thumbnails/5.jpg)
Section 6 — Page 83
PREFORMED LINE PRODUCTS
Figure 8 Fiber Optic Cable:For All-Dielectric messengers, the messenger with
jacket intact is separated from the fiber bundle and atwo piece Dielectric Dead-end is applied over thejacketed messenger. For metallic messengers, a con-ventional strand dead-end is applied directly to thebare messenger. Consult PLP for specifics for eitherstyle messenger.
Component Reuse:Once installed, the structural reinforcing rods and
formed dead-end components may be removed andreinstalled once for repositioning purposes; do notreuse after this initial installation. The hardware maybe reused as desired if in good condition. Do notmodify any component.
Ordering Instructions:For Limited Tension and Medium Tension Dead-
ends, use the appropriate table in this section if yourinstallation meets the restrictions for this product.For all other dead-ends, contact PLP with cable speci-fications, line design details and advise of unusualoperating conditions or high temperature environ-ments so that proper dead-end designs can be se-lected.
To have accessories included with any Dead-end,add the appropriate suffix to the dead-end catalognumber. Example: #2872001C1E1 includes Dead-end #2872001, Thimble Clevis TC-5F and ExtensionLink kit. See next page for available accessories.
High Tension Dead-end features:
• Custom design parameters• Designed for specific cable diameter and OD
ranges, listed on ID tags• Custom length Structural Reinforcing Rods
and Dead-ends to match tension applications• Structural Reinforcing Rods and Dead-end
components packaged in same carton• Utilizes either ATC-20M and TC-6F Thimble
Clevis• Accessories can be ordered with Dead-end
components using suffix codes
High Tension Dead-ends:Custom designed and manufactured for more strin-
gent holding requirements and operating conditionsthan Limited and Medium Tension Dead-ends. Hold-ing performance will vary depending upon the spe-cific cable brand and operating conditions, thereforeno general holding strength rating is possible. Con-sult PLP® for the proper dead-end application.
In general, High Tension Dead-ends are intendedfor use with these conditions:• High tensions, approximately
- over 2,000# (8.9 kN) initial (everyday/stringing)tension- over 4,000# (17.8 kN) loaded tension
• Long spans - varies according to cable ODand tensions
• High strength circular cables• “Standard” and “track resistant” jackets• All cable brands• Selection and design considers excessive operat-
ing conditions, cable motion and high temperatureenvironments
FIBERLIGN® Dielectric Dead-end for ADSS
![Page 6: Accesorios Para ADSS-Preformed](https://reader031.vdocuments.pub/reader031/viewer/2022020518/577c80c61a28abe054aa1f4d/html5/thumbnails/6.jpg)
Section 6 — Page 84
PREFORMED LINE PRODUCTSFIBERLIGN® Dielectric Dead-end Accessories
All Dielectric Dead-ends require a proper size andstrength Thimble Clevis and may utilize an ExtensionLink.
To include accessories with dead-end, add suffixcode(s) to Dead-end catalog number.
Thimble Clevis:Limited and Medium Tension Dead-ends require
the Catalog No. TC-5F Thimble Clevis (Rated Strength26,900# (119 kN)) suffix Code "C1" or Cat No. TC-5AThimble Clevis (Rated Strength 12,000# (53 kN)). Thegalvanized ductile iron #TC-5F is standard with a2-1/4" minimum seat and 7/8" minimum groove di-ameter. The aluminum #TC-5A is optional with thesame dimensional characteristics.
High Tension Dead-ends require at least the 20,000#(89 kN) ATC-20M Thimble Clevis (code C2) or equalwith 3" minimum seat and 1-1/2" minimum groovediameters. For higher loads, use the 42,400# (188 kN)TC-6F (code C4) galvanized iron Thimble Clevis orequal with 2-1/2" minimum seat diameter and 1-1/16"minimum groove diameter.
Extension Link:An optional 15,000# (67 kN) 14" (356 mm) Exten-
sion Link with 5/8" Eye Nut (Cat. #71002366, codeE1) is suggested and sometimes recommended bycable suppliers to increase the cable bending radiusand reduce stress to the optical fibers at Dead-endlocations. This link kit can be used with any typeFIBERLIGN Dielectric Dead-end.
For higher loads, use the 25,000# (111 kN), 14" (356mm) Extension Link (Cat.# LCE-66-14 or P/N00060132).
Loads up to 36,000 pounds can be handled withCat. No. 000601325 (not shown).
Banding Bracket:Dielectric Dead-ends can be banded to concrete or
steel structures using the 12Klb Banding Bracket Kit(Cat. #710010745, code B1). The kit includes a5/8"-11x2" long bolt, lockwasher, hex nut and band-ing bracket. This connects to the Extension Link with5/8" eye nut referenced above (Cat #71002366).The bracket is rated for 12,000# (53 kN) and should beused with two high strength 1-1/4" steel bands (bandspurchased separately).
TC-5F Thimble Clevis(Code C1)
ATC-20M Thimble Clevis(Code C2)
TC-6F Thimble Clevis(Code C4)
(A) 14" Extension Link with Eye Nut, 15K(Cat. No. 71002366, code E1)
(B) 25K EXTENSION LINK(Cat. No. LCE-66-14, code E2)
Banding Bracket Kit(Cat. No. 710010745, code B1)
12Klb
A
B