Features • Microcontroller based DIN rail mountable automatic source changeover with neutral isolation • Inbuilt SMPS for low power consumption • Operational status indication through LEDs • Manual reset provision for restoring supply, when in sleep mode • Automatic generator on/off facility (on special demand) • Staggered terminal design with bottom wiring for better isolation between phase & neutral Introducing Automatic Changeover with Current Limiter (ACCL) The intelligent start-up solution

Upload: unni-venugopal

Post on 21-Jul-2016

36 views

Category:

Documents


4 download

DESCRIPTION

Automatic Changeoverwith Current LimiterThe intelligent start-up solutionSPN(Sinle phase) and TPN (Three Phase)From Havells

TRANSCRIPT

Page 1: ACCL CATALOUGE

Features

• MicrocontrollerbasedDINrailmountableautomaticsourcechangeoverwithneutralisolation

• InbuiltSMPSforlowpowerconsumption

• OperationalstatusindicationthroughLEDs

• Manualresetprovisionforrestoringsupply,wheninsleepmode

• Automaticgeneratoron/offfacility(onspecialdemand)

• Staggeredterminaldesignwithbottomwiringforbetterisolationbetweenphase&neutral

Introducing

AutomaticChangeoverwithCurrentLimiter(ACCL)The intelligent start-up solution

Page 2: ACCL CATALOUGE

ACCL

Automatic Changeover with Current Limiter (ACCL) An indispensable tool to automate power distribution, protectexpensivegensetsandpreventfatalrisks-Thepowerinstabilityindevelopingcountriesalongwith the inefficient rationalizedpowerdistribution creates a need for the alternative source of power,tobackuptheutilitysupply,andhence,mostofthecommercialand residential complexesset-upalternatepowersources, suchas gensets, to provide efficient back-up for their power needs.However,mostof theseusersofalternatepowerstilldependonmanual change-over, which leads to issues such as increaseddowntime, disruption in key activities aswell as critical damageto the expensive equipment and could also prove fatal to theoperators.

HAVELLSINDIALTD–Nation’sleadingplayerinpowerdistributionequipment and solutions, now offers HAVELLS ACCL, afully automatic high precision microcontroller based ‘SourceChangeover’device,whichalsohascurrent limitingfunctionandoffers easy and ‘controllable’ changeover between main powersupplyandgeneratorsupply.

Withtheseinherentstrengths,HAVELLSACCLisbeingincreasinglyadoptedbyleadingpowerconsumers,bothatcommercialaswellas residential levels, as a strong and proven power distributionmanagementtool.

Sogoahead,andempoweryourpremisesandpowerdistributionwithHAVELLSACCLtoday!

Functions- When the Mains Supply is available:a. The ACCL allows unrestricted supply from Mains in case

currentisinallowablelimits.b. Ifthecurrentexceedthemainsrating,theloadisdisconnected

afteradelayof5secondsanditwillremaindisconnectedfor8secondsasawarningandthenautomaticallyreconnectsit.Duringthisperiod,theconsumerisexpectedtoswitchoffthenon-essentialloadsandbringitwithinthelimit.

c. Inanunlikelyevent,iftheconsumerdoesnotswitchoffthenonessentialloadstoreduceittowithinthelimit,supplytotheloadfromthemainsisautomaticallydisconnectedafter5cyclesofinterruption.

d. The supply from mains to the load can be restored afterpressingtheresetbuttonpresentinthefrontofACCL.

- When the Mains supply fails WithoutAGS(automaticgeneratorstartfeatures)-Whenthe

mainssupplygoesOFF,aconsumerisautomaticallyconnectedto thegenerator incasegeneratorsupply isavailableafteratimedelayof8to12secondsinordertolimitthesuddenloadonthegenerator.

With AGS (automatic generator start features) - ACCLProvidessignaling throughapotential freecontact forstartingthe Generator (Generator must have control unit for auto

Start/off) andthenconsumerisautomaticallyconnectedtothegeneratorafteratimedelayof8to12secondsinordertolimitthesuddenloadonthegenerator.

Once the supply goes to generator side then:a. ACCLlimitstheuserfromdrawingexcessloadcurrentbeyond

thepre-setlimit.b. Ifthecurrentexceedstheallowablelimit,theACCLwillindicate

theoverloadconditionbyglowingits“overload”LED.Duetothis the load isdisconnectedafteradelayof5secondsandwillremaindisconnectedfor8secondsasawarningandthenautomaticallyreconnects.Duringthisperiod,theconsumerisexpected toswitchoff thenon-essential loadsand reduce itwithinthelimit.

c. Inanunlikelyevent, if theConsumerdoesnotswitchoff thenonessential loads to reduce it towithin the limit, supply totheloadfromthemainsisautomaticallydisconnectedafter5cyclesofinterruptions.

d. The supply fromGen to the load canbe restoredonly afterpressingtheResetbuttonpresentinthefrontofACCL.

Technical Specifications

Standard Conformity IEC60947-6-1

No. of Poles 1P+N

Rated current (In) 30Aonmains,1.5-20Aongenerator

Rated voltage (Ue) 240Vac

Rated frequency 50Hz

Rated insulation voltage 500V

Transfer time 8to12sec

Restoring Time 2to4sec

Utilization Category AC31B

Class of Equipment PC

Environment B

Indication Mains,Generator,Load,Overload

Ambient Temp. -5to+55°C

Electrical Life 6000operations

Rated Impulse Voltage 1.5kV

Duty Uninterrupted

Pollution Degree 2Conditional Short Circuit Current

3kA

Protection Class IP20

Mounting standardmountingRAIL(35x7.5mm)

Mounting Position Vertical/Horizontal

Terminal Capacity mm² 10

Weight 350gms.

Page 3: ACCL CATALOUGE

ACCL

Feature Benefits of Havells ACCL

L N

Main supply

N L

Input from mains supply

Input from GEN supply

Auto GEN start control unit

GEN with auto start control unit

Ignition signal to remote GEN start terminals

OutputMCB /RCCB

NLoad

ACCL

L

SCPD 1

SCPD 2

Terminals available in ACCL forGEN. ON/OFF feature

*SCPDcanbe32AHRCFUSEor32AMCB

Features Advantage of Havells ACCL Other Competitor Products

Compact DesignRequireslessinstallationspace,itcanbefittedinanyDBsasdimensionissameas4PoleMCB

(87.5x71.8x63)108x72x68

Terminals for External ConductorsPreventconnectionerror(Indirectpressuretype)

Directpressuretype

Conditional Short Circuit Current 3kA Notmentioned

Eco Friendly Housings Thermoplastic,PA6FRGrade Thermoplastic

Local Reset Facility Resetbuttonprovided,sono

extraswitchrequiredforrestoringsupplyExtraswitchingdevicerequired

forrestoringsupply

Overload Indication Customerknowsimmediatelyincaseofoverload Notprovided

Standard Conformity AsperIEC60947-6-1 Nomarkingonproduct

Rated Impulse Voltage 1.5kV Notmentioned

Operational Voltage 80-300Vac 180-240Vac

Electrical Life Longerlifeproduct(>6000ops.) Notmentioned

Pre-Trip Indication Under Overload Condition

Provided Notprovided

Utilization Category Longercontactlife(AC31B/IEC60947-6-1) Notmentioned

Vents Provided for Cool Running Lowtemperaturerise Novents

ACCL Wiring Arrangement during Installation

Page 4: ACCL CATALOUGE

SW

I/Z

HD

LE00

012/

JUL1

1/A

PR

12

71.8

87.5

Front view36 45

63

Side view

Dimensions (in mm)

Mains Rating Gen Rating Product Code Description

ACCL

SPN30(6000W) SPN1.5(300W) DHACOSN301X 30A/1.5AACCLW/OGENSTART/STOP

SPN30(6000W) SPN2.5(500W) DHACOSN302X 30A/2.5AACCLW/OGENSTART/STOP

SPN30(6000W) SPN3(600W) DHACOSN3003 30A/03AACCLW/OGENSTART/STOP

SPN30(6000W) SPN4(800W) DHACOSN3004 30A/4AACCLW/OGENSTART/STOP

SPN30(6000W) SPN5(1000W) DHACOSN3005 30A/5AACCLW/OGENSTART/STOP

SPN30(6000W) SPN6(1200W) DHACOSN3006 30A/06AACCLW/OGENSTART/STOP

SPN30(6000W) SPN9(1800W) DHACOSN3009 30A/09AACCLW/OGENSTART/STOP

SPN30(6000W) SPN12(2400W) DHACOSN3012 30A/12AACCLW/OGENSTART/STOP

SPN30(6000W) SPN15(3000W) DHACOSN3015 30A/15AACCLW/OGENSTART/STOP

SPN30(6000W) SPN20(4000W) DHACOSN3020 30A/20AACCLW/OGENSTART/STOP

ACCL with Generator ON/OFF

SPN30(6000W) SPN3(600W) DHACWSN3003 30A/03AACCLWITHGENSTART/STOP

SPN30(6000W) SPN6(1200W) DHACWSN3006 30A/06AACCLWITHGENSTART/STOP

SPN30(6000W) SPN9(1800W) DHACWSN3009 30A/09AACCLWITHGENSTART/STOP

SPN30(6000W) SPN12(2400W) DHACWSN3012 30A/12AACCLWITHGENSTART/STOP

SPN30(6000W) SPN15(3000W) DHACWSN3015 30A/15AACCLWITHGENSTART/STOP

SPN30(6000W) SPN20(4000W) DHACWSN3020 30A/20AACCLWITHGENSTART/STOP

Price List

Havells India Ltd. CorpOffice:QRGTowers,2D,Sector-126,Expressway,Noida-201304(U.P),Ph.+91-120-4771000,Email:[email protected],www.havells.comConsumerCareNo.:1800110303(Tollfree),011-41660303(Landline),18001031313(AllConnections)JoinusonFacebookatwww.facebook.com/havellsandshareyourwaystosavetheplanet!

Page 5: ACCL CATALOUGE

Features

•Microcontroller based automatic changeover with isolated neutral

• Current limitation on generator side

•Operational status indication through membrane keypad

•Manual reset provision for restoring supply, when in sleep mode

•Mode selection feature i.e automatic or manual

• Automatic generator on/off facility (on special demand)

Introducing

Three Phase Automatic Changeover with Current Limiter (TPN ACCL)The Intelligent start-up solution

Page 6: ACCL CATALOUGE

ACCL

Three Phase Automatic Changeover with Current Limiter (TPN ACCL) The Power instability in developing countries along with the inefficient rationalized power distribution creates a need for the alternative source of power, to back up the utility supply. This further necessitates the automation, in the distribution system as the rate of power outage & low voltage output becomes predominantly high. Most of the Residential & commercial processes are dependent on power supply & if the process of changeover is manual, this will not only create the hindrance in important activities but it may also damage the device or machine from human error during the changeover.

Havells TPN ACCL is a fully automatic high precision microcontroller based device and is ideally suited for proper/efficient utilization of standby generator used in multi-storied apartments, commercial complexes, etc.

Functions1. When the Mains Supply is available: Automatic mode:• TheTPNACCLallowsfullloadcurrentoneachphasewhenall

the 3 phases of mains supply is available, and when any one of the phase fails, TPN ACCL will automatically senses and actuates the inbuilt changeover mechanism to the generator supply.

Manual mode:• IfRphaseisavailable,itwillcountinuetoruntheloadonmain

supply irrespective of the availability of other phases. But if R phase fails, the TPN ACCL will automatically senses and actuates the inbuilt changeover mechanism to the generator supply.

Note:ItisrecomendedtoconnectallessentialloadtoRphase.

2. When the Mains supply fails With AGS (automatic generator start feature):• TPN ACCL provides signaling through a potential free contact

for starting the Generator.

Without AGS (automatic generator start feature):• When the mains supply goes OFF, a consumer is automatically

connected to the generator in case generator supply is available, after a time delay of 8-12 seconds in order to limit the sudden load on the generator.

• TheTPNACCLhasacurrent limitingfeatureonthegeneratorside.Iftheloadexceedstheallowablelimit,TPNACCLwillgiveapre-trip indication and after a delay of 5 second, TPN ACCL will trip and goes on hold. After a predetermined time delay (say 8 sec), it will again check the connected load and gives the supply if the load is under the allowable limit. During this period, the consumer is expected to switch off the non-essential loads and reduce it within the limit. The overloaded phase will be indicated through LED.

• Inanunlikelyevent,iftheconsumerdoesnotswitchoffthenon-essential loads to reduce it to within the limit, supply to the load is automatically disconnected after 5 cycles of interruption.

• Thesupply frommains to the loadcanbe restoredonly afterpressing the Reset button present in the front of TPN ACCL.

3. When Mains supply is restored

• As soon as the main supply restores, the load is automatically transferred to the mains supply after a delay of 2-4 sec.

• WithAGS,TPNACCLitselfgeneratesthesignaltoautomaticallystop the generator

Technical Specifications

Standard Conformity IEC60947-6-1

No. of Poles 3P+N

Rated current (In)40A/63A/100A on mains, 10-100A on generator

Rated voltage (Ue) 415 / 220 Vac

Rated frequency 50 Hz

Transfer Time 8-12 sec

Restoring Time 2-4 sec

Rated Impulse Voltage (Uimp)

6kV

Utilization Category AC 31A

Class of Equipment PC

Environment B

IndicationMains, Generator, Load, Overload (R,Y,B), mode of operation (auto/manual)

Pollution Degree II

Conditional Short Circuit Current

5kA

Ambient Temp. - 5 to + 55 ˚C

Electrical Life 6000 operations

Mounting Surface mounting

Mounting Position Vertical

Terminal Capacity 16 mm2 / 35 mm2

Duty Uninterrupted

Weight 4.5 Kg / 9.4 Kg

Dimensions260 x 243 x 115 mm3

260 x 243 x 150 mm3

383 x 333 x 150 mm3

Page 7: ACCL CATALOUGE

Main supply

MCB/RCCB

Load

Generator

L N

SCPD 2

R Y B N

SCPD 1

Auto GEN start control unit

MAINS LOAD IGNGEN

R Y B N R Y B N L N X1 X2

ACCL

ACCL TPN/TPN Wiring Arrangement during Installation

Main supply

MCB/RCCB

Load

Generator

R Y B N

SCPD 2

R Y B N

SCPD 1

Auto GEN start control unit

MAINS LOAD IGNGEN

R Y B N R Y B N R Y B N X1 X2

* SCPD can be - 40A MCB or fuse for 40A TPN ACCL - 63A MCB or fuse for 63A TPN ACCL - 100A MCB or fuse for 100A TPN ACCL

* SCPD can be - 40A MCB or fuse for 40A TPN ACCL - 63A MCB or fuse for 63A TPN ACCL - 100A MCB or fuse for 100A TPN ACCL

InTPN/SPN,theACCLwillrestricttheloadifthecumulativecurrentofallthe3phases(ieR+Y+B)exceedsratedgeneratorcurrent.

InTPN/TPN,theACCLwillrestricttheloadifthecurrentinanyofthephase(ieRorYorB)exceedsratedgeneratorcurrent.

ACCL TPN/SPN Wiring Arrangement during Installation

Page 8: ACCL CATALOUGE

ACCL

Features Advantage of Havells TPN ACCL Other Competitor Products

Mode Selectioncan be operated in two different modes ie

automatic or manual as per customer requirementnot provided

Separate LED indication for individual overloaded phase

customer immediately comes to know the overloaded phase & can easily reduce the load

running on that phasenot available

Local reset facilityreset button provided, so no extra switch required

for restoring supplyextra switching device required for restoring

supply

Rated impluse voltage 6kV not mentioned

Pre-trip LED indication under overload condition

provided not provided

Standard conformity asperIEC60947-6-1 no marking on the product

Conditional short circuit Current 5kA not mentioned

Operating range 150 - 415 Vac 150 - 360 Vac

Automatic gen ON/OFF available (on special demand) not available

Feature Benefits of Havells TPN ACCL

Dimension (in mm)

Side Front

BAC

DE

Rating A B C D E

40A TPN ACCL 115 243 205 224 260

63A TPN ACCL 150 243 205 224 260

100A TPN ACCL 150 333 293 337 383

Page 9: ACCL CATALOUGE

SW

I/Z

HD

LE00

015/

SE

P11

/AP

R12

Havells India Ltd. Corp Office: QRG Towers, 2D, Sector-126, Expressway, Noida-201304 (U.P), Ph. +91-120-4771000, Email: [email protected], www.havells.com Consumer Care No.: 1800 11 0303 (Tollfree), 011-4166 0303 (Landline), 1800 103 1313 (All Connections)Join us on Facebook at www.facebook.com/havells and share your ways to save the planet!

TPN ACCL

TPN ACCL (TPN/SPN)(Automatic Source Changeover with Current Limiter)

TPN ACCL (TPN/TPN)(Automatic Source Changeover with Current Limiter)

Gen Rating Description Cat. No. Cat. No. with GEN Start/Stop

20A 40A/20A TPN/SPN ACCL DHACOTN4020 DHACWTN4020

25A 40A/25A TPN/SPN ACCL DHACOTN4025 DHACWTN4025

30A 40A/30A TPN/SPN ACCL DHACOTN4030 DHACWTN4030

40A 40A/40A TPN/SPN ACCL DHACOTN4040 DHACWTN4040

20A 63A/20A TPN/SPN ACCL DHACOTN6320 DHACWTN6320

25A 63A/25A TPN/SPN ACCL DHACOTN6325 DHACWTN6325

30A 63A/30A TPN/SPN ACCL DHACOTN6330 DHACWTN6330

40A 63A/40A TPN/SPN ACCL DHACOTN6340 DHACWTN6340

Gen Rating Description Cat. No. Cat. No. with GEN Start/Stop

20A 40A/20A TPN/TPN ACCL DHACOTT4020 DHACWTT4020

25A 40A/25A TPN/TPN ACCL DHACOTT4025 DHACWTT4025

30A 40A/30A TPN/TPN ACCL DHACOTT4030 DHACWTT4030

40A 40A/40A TPN/TPN ACCL DHACOTT4040 DHACWTT4040

20A 63A/20A TPN/TPN ACCL DHACOTT6320 DHACWTT6320

25A 63A/25A TPN/TPN ACCL DHACOTT6325 DHACWTT6325

30A 63A/30A TPN/TPN ACCL DHACOTT6330 DHACWTT6330

40A 63A/40A TPN/TPN ACCL DHACOTT6340 DHACWTT6340