    ■ Processor

    - Intel 3rd Core i7-3555LE/Celeron 847E

    ■ Memory

    - 204-pin SODIMM DDR3 1333/1600MHz,

    Up to 8GB

    ■ Chipset

    - Intel 3rd Core i7-3555LE + QM77

    - Intel Celeron 847E + HM76

    ■ I/O Chipset

    - Fintek 81866D

    ■ Ethernet

    - Intel 82579LM & Intel 82583V

    - 10/100/1000 Base-TX

    - 2 x Gigabit Ethernet, 2 x RJ-45

    ■ BIOS

    - UEFI

    ■ Wake On LAN

    - Yes

    ■ Watchdog Timer

    - Programmable 255 level System Reset

    ■ H/W Status Monitoring

    - Supports Power Supply Voltage, FAN

    Speed and Temperature Monitoring

    ■ Expansion Interface

    - Mini Card

    - PCI – 104(optional), TPM(optional)

    ■ Battery

    - Lithium battery

    ■ Power Requirement

    - +12V, AT/ATX (default)

    ■ Power Consumption (Typical)

    - Intel Core i7-3555LE 2.5GHz, 8GB

    - 3.04A+12V

    ■ Board Size

    - 4.5” x 6.5” (115mm x 165mm)

    ■ Gross Weight

    - 1.2lb (0.5kg)

    ■ Operating Temperature

    - 32℉~140℉ (0℃ ~ 60℃)

    ■ Storage Temperature

    - -40℉~176℉ (-40℃~80℃)

    ■ Operating Humidity

    - 0%~90% relative humidity,

    non-condensing

    ■ MTBF (Hours)

    - 88,000

    ■ Display Chipset

    - Intel QM77/HM76 integrated

    ■ Display Resolution

    - Up to 2048 x 1536 for CRT

    - Up to 1920 x 1200 for HDMI

    - Up to 1920 x 1200 for DVI (optional)

    - Up to 1920 x 1080 for LCD

    ■ LCD Interface

    - Up to 24-bit Dual-Channel LVDS x 1

  • ALTSOFT

    ■ Storage

    - 2 x SATA, 1 x mSATA

    ■ Serial Port

    - 5 x RS-232, 1 x RS-232/422/485 (COM2)

    ■ Parallel Port

    - 1 x SPP/EPP/ECP

    ■ USB Port

    - 2 x USB3.0, 4 x USB2.0

    ■ PS/2 Port

    - 1 x Keyboard, 1 x Mouse

    ■ Digital I/O

    - Supports 16-bit (Programmable) Co-lay

    with LPT

    ■ Audio

    - Line-in, Line-out, Mic-in

    ■ Touch Screen

    - Support 4/5-wire Resistive Touch Screen

    (optional)

    ■ CODESYS Runtime

    - IEC 61131-3 (IL, ST, FBD, CFC, LD)

    - Fieldbus: EtherCAT

    - SoftMotion, CNC

    - Visualization (HMI, Target, Web)

  • ALTSOFT

    Connector Information

  • ALTSOFT

    Dimension

    Unit : mm

  • ALTSOFT

    목 차

    1. Block Diagram ..................................................................................................................................... 1

    2. Installation ............................................................................................................................................ 2

    3. AltPLC QM77과 연결 .......................................................................................................................... 3

    3.1 AltPLC QM77과 PC 연결 .......................................................................................................................................... 3

    3.2 IP 설정 .............................................................................................................................................................................. 3

    3.3 Ping Test ........................................................................................................................................................................... 4

    3.4 CODESYS 프로젝트 생성하기 ................................................................................................................................ 4

    3.5 디바이스 및 언어 선택 ............................................................................................................................................. 5

    ※ Note .................................................................................................................................................................................... 5

    3.6 디바이스 스캔 및 연결 ............................................................................................................................................. 6

    3.7 AltPLC QM77과 연결 확인 ...................................................................................................................................... 7

    3.8 Example Link .................................................................................................................................................................. 7

    4. Slave Device와 연결 ............................................................................................................................ 8

  • 1

    ALTSOFT

    1. Block Diagram

    Figure 1. AltPLC QM77 Block Diagram

    AltPLC QM77 는 인텔 3세대 i7-3555LE(3.20GHz 클럭, 4MB 캐시, 64비트 듀얼 코어 / Celeron 가

    능) 프로세서를 탑재하고 있습니다. 메모리는 Onboard 타입의 1333/1600 DDR3 8GB RAM이 장착

    되어 있으며, 저장 매체는 SATA 3.0과 mSATA 방식의 방식의 디스크가 지원됩니다.

    Ethernet RJ45 포트를 통해 10/100/1000 Gigabit Ethernet 사용이 가능하고, 디스플레이 단자로는

    CRT 또는 DVI, HDMI, 24-bit LVDS가 제공됩니다. 입력 전원은 12VDC 이며, COM, USB, PS/2 인터

    페이스를 포함하고 있습니다.

    OS는 Windows XP 또는 Windows 7을 지원하고, Real-time CODESYS Runtime이 기본 설치됩니다.

  • 2

    ALTSOFT

    2. Installation

    • 아래의 사이트에서 설치방법을 확인하여 CODESYS 툴을 설치합니다.

    - http://www.altsoft.kr/ > 커뮤니티 > CODESYS 자료실 > CODESYS 툴 설치방법

    • Power Input 포트에 DC 12V 전원을 인가합니다.

    Figure 2. AltPLC QM77 전원 연결

    http://www.altsoft.kr/

  • 3

    ALTSOFT

    3. AltPLC QM77과 연결

    User PC와 AltPLC QM77 간 LAN 케이블을 연결합니다. User PC의 IP를 설정하고, Ethernet 통

    신 확인을 위해 PING 테스트를 합니다.

    CODESYS 프로젝트를 생성한 후, 디바이스 스캔을 합니다. Device 항목의 Communication

    Setting 탭에 AltPLC QM77의 Host Name이 나타나면 디바이스 연결은 완료됩니다.

    3.1 AltPLC QM77과 PC 연결

    AltPLC QM77의 LAN2포트와 User PC포트를 연결합니다. (AltPLC QM77 IP : 192.168.0.3)

    Figure 3-1. AltPLC QM77 와 PC 연결

    3.2 IP 설정

    User PC의 IP는 192.168.0.2로 설정합니다.

    Figure 3-2. User PC IP 설정

  • 4

    ALTSOFT

    3.3 Ping Test

    cmd.exe를 실행시켜 연결을 확인을 합니다. C:\~$〉 Ping 192.168.0.3

    Figure 3-3. PING 테스트를 통한 네트워크 연결 확인

    3.4 CODESYS 프로젝트 생성하기

    시작 메뉴 또는 바탕화면 아이콘을 통해 CODESYS 프로그램을 실행합니다. File 메뉴의 New

    Project를 선택하여 프로젝트 이름과 경로를 입력합니다.

    Figure 3-4. CODESYS 프로젝트 생성하기

  • 5

    ALTSOFT

    3.5 디바이스 및 언어 선택

    Standard Project 대화상자에서 CODESYS SoftMotion RTE V3 (3S- Smart Software Solutions

    GmbH) 디바이스와 ST 언어를 선택하고 OK 버튼을 누릅니다. (언어는 FBD, IL, LD, ST, SFC,

    CFC 중 선택 가능)

    Figure 3-5. 디바이스 및 언어 선택

    ※ Note

    Update Device는 현재 선택된 Device를 다른 Device로 변경하여 사용할 수 있도록 합니다.

    만약, CODESYS SoftMotion RTE V3(Smart Software Solutions GmbH)가 아닌 다른 디바이스

    를 선택하여 프로젝트가 생성된 경우, Device에서 우클릭 후 Update Device를 클릭합니다.

    Figure 3-5-1. Update Device를 통한 디바이스 변경 1

  • 6

    ALTSOFT

    Update Device 창에서 Action은 Update Device, Vendor는 로 지정하고,

    CODESYS SoftMotion RTE V3를 더블 클릭하여 디바이스를 변경합니다.

    Figure 3-5-2. Update Device를 통한 디바이스 변경 2

    3.6 디바이스 스캔 및 연결

    Device (CODESYS SoftMotion RTE V3) 더블 클릭 후 Scan network를 통해 해당 디바이스를 선

    택하고 OK 버튼을 누릅니다.

    Figure 3-6. EPIC-QM77 PLC 디바이스 스캔 및 연결

  • 7

    ALTSOFT

    3.7 AltPLC QM77과 연결 확인

    AltPLC QM77가 제대로 연결된 경우 아래와 같이 Gateway와 디바이스 연결 상태가 녹색으로

    변경됩니다.

    Figure 3-7. AltPLC QM77와 연결 확인

    3.8 Example Link

    AltPLC QM77과의 연결이 정상적으로 완료 되었습니다.

    당사 홈페이지 CODESYS 자료실(http://www.altsoft.kr/codesys-faq)에서 예제를 참고하시어

    다른 내용들도 확인하시길 바랍니다.

    http://www.altsoft.kr/codesys-faq

  • 8

    ALTSOFT

    4. Slave Device와 연결

    AltPLC QM77의 RJ45 Connector를 통해 Slave Device와 연결합니다.

    Figure 4. AltPLC QM77 와 EtherCAT Slave Device 연결

    FeaturesConnector InformationDimension목 차1. Block Diagram2. Installation3. AltPLC QM77과 연결3.1 AltPLC QM77과 PC 연결3.2 IP 설정3.3 Ping Test3.4 CODESYS 프로젝트 생성하기3.5 디바이스 및 언어 선택※ Note

    3.6 디바이스 스캔 및 연결3.7 AltPLC QM77과 연결 확인3.8 Example Link

    4. Slave Device와 연결