Chapter 10

Atomic Emission Spectrometry

10A EMISSION SPECTROSCOPYBASED ON PLASMA SOURCES

歐亞書局

Inductively coupled plasma (ICP)

Direct current plasma (DCP)

Microwave induced plasma (MIP)

10A-1 The Inductivity Coupled Plasma Source

歐亞書局

FIGURE 10-1

A typical

ICP source. Position A

shows radial viewing of

the torch, and position B

shows axial viewing.

歐亞書局

歐亞書局

歐亞書局

歐亞書局

Sample introduction

歐亞書局

FIGURE 10-2 The Meinhard nebulizer. The nebulizing gas flows

through an opening that surrounds the capillary concentrically. This causes a reduced pressure at the tip and aspiration of the sample. The high-velocity gas at the tip breaks up the solution into a mist.

歐亞書局

Plasma Appearance and Spectra

Analyte Atomization and Ionization

歐亞書局

FIGURE 10-3 Device for electrothermal vaporization.

歐亞書局

FIGURE 10-4 Temperatures in a typical ICP course.

10A-2 The Direct Current Plasma Source

歐亞書局

FIGURE 10-5 A three-electrode DC

plasma jet.

歐亞書局

10A-3 Plasma Source

Spectrometers

歐亞書局

Instruments for emission spectroscopy are of three

basic types: sequential, simultaneous multichannel, and

Fourier transform.

歐亞書局

TABLE 10-1 Desirable Properties of an Emission Spectrometer

歐亞書局

Sequential Instruments

Slew-Scan Spectrometers

Scanning Echelle Spectrometers

歐亞書局

FIGURE 10-6 Optical diagram of a sequential ICP optical emission spectrometer. All

moving parts are under computer control, and their modes of motion are indicated bythe three-dimensional arrow. Moving parts include the grating, a mirror for transducer selection, a refractor plate for optimizing signal throughput, and a viewing mirror to optimize the plasma viewing position. The spectrometer contains a mercury lamp for automatic wavelength calibration. Notice the axial viewing geometry.

歐亞書局

歐亞書局

FIGURE 10-7 Schematic of an echelle spectrograph system.

歐亞書局

Multichannel Spectrometers

Polychromators.

歐亞書局

FIGURE 10-8 Direct-reading ICP emission spectrometer. The polychromator is of the Paschen-Runge design. It features a concave grating and produces a spectrum around a Rowland circle. Separate exit slits isolate each spectral line,and a separate photomulitiplier tube converts the optical information from each channel into an electrical signal. Notice the radial viewing geometry. PMT= photomultiplier tube.

歐亞書局

ICP-AES

歐亞書局

A Charge-Injection Device Instrument

歐亞書局

FIGURE 10-9 Optical diagram of an echelle spectrometerwith a charge-injection detector.

歐亞書局FIGURE 10-10

歐亞書局

FIGURE 10-10(a) Schematic representing the surface of a CID. The short horizontal lines represent the read windows. A magnified image of one of the read windows is also shown. The nine central elements form the examination window, where a line is positioned.

歐亞書局

FIGURE 10-10(b)

Intensity profile for an iron

line. All of the radiation

from the line falls on the

3 × 3 examination window.

歐亞書局

A Charge-Coupled Device Instrument

A Combination Instrument

歐亞書局

FIGURE 10-11 An echelle spectrometer with segmentedarray of CCDs.

歐亞書局

FIGURE 10-12 Schematic of an array segment showing

phototransducers, storage and output registers, and readout

circuitry.

歐亞書局

Fourier Transform Spectrometers

Fourier, Joseph

歐亞書局

10A-4 Applications of

Plasma Sources

歐亞書局

Sample Preparation

Elements Determined

歐亞書局

Line Selection

Calibration Curves

歐亞書局

FIGURE 10-13 Periodic table characterizing the detection power and number of useful emission lines of ICP by using a pneumatic nebulizer. The color and degree of shading indicate the range of detection limits for the useful lines. The area of shading indicates the number of useful lines.

歐亞書局

FIGURE 10-14 Typical calibration curves in ICP emission spectrometry.

歐亞書局

FIGURE 10-15 Internal

standard calibration

curves with an ICP

source. Here, an yttrium

line at 242.2 nm served

as an internal standard.

Notice the lack of

interelement

interference.

歐亞書局

Interferences

Detection Limits

歐亞書局

歐亞書局

10B EMISSION SPECTROSCOPY BASEDON ARC AND SPARK SOURCES

歐亞書局

These spectra permitted the qualitative and quantitative determination of metallic elements in

a variety of sample types, including metals and alloys,

soils, minerals, and rocks,

歐亞書局

TABLE 10-2 Effect of Standardization Frequency on Precision of ICP Data

歐亞書局

10B-1 Sample Types and Sample Handling

歐亞書局

Metals

Nonmetallic Solids

歐亞書局

TABLE 10-3 Comparison of Detection Limits for Several Atomic spectral Methods

歐亞書局

FIGURE 10-16 Some typical graphite electrode shapes.

Narrow necks are to reduce thermal conductivity.

歐亞書局

10B-2 Instruments for Arc and

Spark Source Spectroscopy

歐亞書局

Spectrographs

歐亞書局

FIGRUE 10-17 The Eagle mounting for a grating spectrograph.

歐亞書局

Multichannel Photoelectric Spectrometers

Multichannel Photomultiplier Instruments.

Array-Based Multichannel Instruments.

歐亞書局

10B-3 Arc Source Emission Spectroscopy

歐亞書局

Characteristics of Arc Sources

Cyanogen Spectral Bands.

Rates or Emission.

歐亞書局

Applications of Arc Sources

歐亞書局

歐亞書局

歐亞書局

10B-4 Spark Sources and Spark Spectra

歐亞書局

Applications of Spark Source Spectroscopy

歐亞書局

10C MISCELLANEOUS SOURCESFOR OPTICAL EMISSION SPECTROSCOPY

歐亞書局

10C-1 Flame Emission Sources

歐亞書局

10C-2 Glow-Discharge Sources

歐亞書局

10C-3 Laser Microprobe Sources

歐亞書局

歐亞書局

歐亞書局