2010 professional catalog - marks supply · (nrc111-sv) save energy. save money. with a noritz...
Post on 13-Aug-2020
1 Views
Preview:
TRANSCRIPT
2010 Professional Catalog
13.8"
23.6"
13.1"
AIR INLET
AIR INLET GAS INLET
10.3"
7.1"
2.8"
4.5"
5.9"
1.4"
WIRING THROUGHWAY
WATER DRAIN VALVE
(WATER FILTER)
HOT WATER OUTLET
WATER DRAIN VALVE
COLD WATER INLET
(120VAC)WIRING THROUGHWAY
WIRING THROUGHWAY
HOT WATER OUTLET (3/4")
(VIEW FROM TOP)
4"
FLUE COLLAR
Noritz Residential
Tankless...Endless Comfort
Condensing Technology
• Neutralizer Included
• Zero clearance to combustibles• 3” or 4” PVC
• Built-in PVC Adapter
• Residual heat used to pre-heat incoming water• Durable & high strength• Corrosion resistant
• Stainless Steel Heat Exchanger
• Commercial grade copper• 25% thicker piping• Unique efficient heat distribution design
• Copper Heat Exchanger
• Temperature Settings from 100˚F-180˚F
Greenest NoritzIf “green” is your thing, then look no further. Noritz condensing units are over 93% efficient and because they are condensing, less expensive PVC venting can be used.
(NRC111-SV)
Save Energy. Save Money.With a Noritz tankless water heater, you'll save energy and thus, money. Our on-demand systems require no standing pilot light and can save about half the cost of your current water heating bill since there is no re-heating of water as with traditional water heaters.
$202
$520
$331 $333
$580$520
AVERAGE YEARLY OPERATING COSTS
Based on FTC Energyguide 16 CFR Part 305, using prices of $1.218/therm for Natural Gas, $1.87/ gal. for LP Gas, and 10.65 cents/kWh for electricity as published in the 08/29/2007 DOE Federal Register Notice, Vol. 72 No.167.
® 50 Gallon Tank Water Heaters
® 50 Gallon Tank Water Heaters
Thermal Efficiency
Temperature Settings
Included Accessories
Dimensions
Weight/ Connections
NG
LPGas Consumption
Capacity Range
Energy Factor
NRC111-SV NRC111-DV NR111-SV NR111-DV
NA*
84%
24.2” (H) x 18.3” (W) x 9.4” (Depth)
62 lbs./ 3/4” Water inlet, outlet & gas
Max. 250,000 Btuh- Min. 11,000 Btuh
Max. 250,000 Btuh- Min. 11,000 Btuh
0.5-11.1 Gal./min.
Remote Control & Cord, Anchoring Screws, Factory Installed Power Cord
24.2” (H) x 18.3” (W) x 9.4” (Depth)
62 lbs./ 3/4” Water inlet, outlet & gas
Max. 250,000 Btuh- Min. 11,000 Btuh
Max. 250,000 Btuh- Min. 11,000 Btuh
0.5-11.1 Gal./min.
NA*
84%
Remote Control & Cord, Anchoring Screws, Power Cord Kit
24.2” (H) x 18.3” (W) x 9.4” (Depth)
74 lbs./ 3/4” Water inlet & outlet, gas
Max. 199,900 Btuh- Min. 11,000 Btuh
Max. 199,900 Btuh- Min. 11,000 Btuh
0.5-11.1 Gal./min.
0.91 (NG), 0.93(LP)
Remote Control & Cord, Anchoring Screws, Condensate Neutralizer,Power Cord Kit
93%
100-150˚F (in 5˚F Intervals), 160, 170,180˚F
100-150˚F (in 5˚F Intervals), 160, 170,180˚F
100-150˚F (in 5˚F Intervals), 160, 170,180˚F
100-150˚F (in 5˚F Intervals), 160, 170,180˚F
24.4” (H) x 18.4” (W) x 9.4” (Depth)
74 lbs./ 3/4” Water inlet & outlet, gas
Max. 199,900 Btuh- Min. 11,000 Btuh
Max. 199,900 Btuh- Min. 11,000 Btuh
0.5-11.1 Gal./min.
0.92 (NG), 0.94(LP)
Remote Control & Cord, Anchoring Screws, Condensate Neutralizer, Factory Installed Power Cord
93.3% (NG), 93.9% (LP)
SV SV
DV
Condensing Condensing
Natural GasCondensing
Tankless Heater
PropaneCondensing
Tankless Heater
DV
Tankless Advantage With a properly sized Noritz, you won’t have to worry about running out of hot water. You will also be heating that water e�ciently, saving energy and money.
SafetyComfort and safety is one of the highest priorities when it comes to Noritz. Our units are equipped with safety features to prevent scalding water from exiting your �xtures.
Clean WaterWith a tankless, you won’t be using hot water that is stored in a tank that can accumulate scale and rust over time, or even worse possible Legionella bacteria.
Endless Hot WaterSince a Noritz tankless heats water on demand, the incoming water is heated as it passes through the heat exchanger, which delivers endless hot water.
Higher Volume Two identical units* can be linked together to double the output or for even higher demands. Up to 24 units* can be linked together to maximize output. (*Select models only.)
ENERGY STAR Quali�edNoritz residential models meet or exceed the criteria set forth for ENERGY STAR quali�cation. With ENERGY STAR certi�cation, you can rest with con�dence a Noritz tankless will save energy and money.
On Demand. Tankless water heaters heat water only when needed, eliminating the wasteful energy use of reheating stored hot water, which is standard with tank-type water heaters.
NR111-OD
NA*
84%
24.2” (H) x 18.3” (W) x 9.4” (Depth)
62 lbs./ 3/4” Water inlet, outlet & gas
Max. 250,000 Btuh- Min. 11,000 Btuh
Max. 250,000 Btuh- Min. 11,000 Btuh
0.5-11.1 Gal./min.
Remote Control & Cord, Anchoring Screws
100-150˚F (in 5˚F Intervals), 160, 170,180˚F
NR98-SV
100-150˚F (in 5˚F Intervals), 160, 170,180˚F
23.6” (H) x 13.8” (W) x 9.4” (Depth)
47 lbs./ 3/4” Water inlet, outlet & gas
Max. 199,900 Btuh- Min. 12,000 Btuh
Max. 199,900 Btuh- Min. 12,000 Btuh
0.5-9.8 Gal./min.
0.83 (NG), 0.83 (LP)
84%
Remote Control & Cord, Anchoring Screws, Power Cord Kit
NR98-DVC
100-150˚F (in 5˚F Intervals), 160, 170,180˚F
23.6” (H) x 13.8” (W) x 10.2” (Depth)
55 lbs./ 3/4” Water inlet, outlet & gas
Max. 199,900 Btuh- Min. 11,000 Btuh
Max. 199,900 Btuh- Min. 11,000 Btuh
0.5-9.8 Gal./min.
0.82 (NG), 0.84 (LP)
84%
Built-in Remote Controller, AnchoringScrews, Factory Installed Power Cord
NR98-OD
100-150˚F (in 5˚F Intervals), 160, 170,180˚F
Remote Control & Cord, Anchoring Screws
23.6” (H) x 13.8” (W) x 9.4” (Depth)
47 lbs./ 3/4” Water inlet, outlet & gas
Max. 199,900 Btuh- Min. 12,000 Btuh
Max. 199,900 Btuh- Min. 12,000 Btuh
0.5-9.8 Gal./min.
0.82 (NG), 0.86 (LP)
84%
DVCSVOD
OD* The US Dept. of Energy considers any water heater that is 200,000 BTU/h or greater to be a “commercial” water heater, and therefore does not allow such products to be rated with an Energy Factor, which is based on residential usage.
Annu
al Sa
vings
($/Y
ear)
Family Size
How Much Can Your Family Save By Going Tankless?
$50
$100
$150
$200
$250
$300
2.6 3 4 5 6
$115$130
$175
$220
$260
PLUMBING-HEATING-COOLINGCONTRACTORS ASSOCIATION
Noritz Residential
Thermal E�ciency
Temperature Settings
Included Accessories
Dimensions
Weight/ Connections
NG
LPGas Consumption
Capacity Range
Energy Factor
NR71-SV NR66-SV*20.5” (H) x 13.8” (W) x 6.7” (Depth)
36 lbs./ 3/4” Water inlet, outlet & gas
Max. 140,000 Btuh- Min. 20,000 Btuh
Max. 140,000 Btuh- Min. 20,000 Btuh
0.5-6.6 Gal./min.
0.82 (NG), 0.84 (LP)
83%
120, 130, 140˚F w/o remote
Anchoring Screws, Power Cord Kit
NR66-OD*20.5” (H) x 13.8” (W) x 6.7” (Depth)
36 lbs./ 3/4” Water inlet, outlet & gas
Max. 140,000 Btuh- Min. 20,000 Btuh
Max. 140,000 Btuh- Min. 20,000 Btuh
0.5-6.6 Gal./min.
0.83 (NG), 0.84 (LP)
83%
120, 130, 140˚F w/o remote
Anchoring Screws
23.6” (H) x 13.8” (W) x 6.7” (Depth)
41 lbs./ 3/4” Water inlet, outlet & gas
Max. 180,000 Btuh- Min. 25,000 Btuh
Max. 180,000 Btuh- Min. 25,000 Btuh
0.5-7.1 Gal./min.
0.83 (NG), 0.83 (LP)
83%
120, 130, 140˚F w/o remote
Anchoring Screws, PowerCord Kit
NR71-OD23.6” (H) x 13.8” (W) x 6.7” (Depth)
41 lbs./ 3/4” Water inlet, outlet & gas
Max. 180,000 Btuh- Min. 25,000 Btuh
Max. 180,000 Btuh- Min. 25,000 Btuh
0.5-7.1 Gal./min.
0.82 (NG), 0.83 (LP)
83%
120, 130, 140˚F w/o remote
Anchoring Screws
Flexible InstallationWith the compact size and broad selection, Noritz tankless water heaters can be installed virtually anywhere. Indoor or outdoor, Noritz has the unit, venting and accessories needed for the job.
Vertical venttermination
Horizontal venttermination
Basement DVinstallation
Outdoorinstallation
Recess boxinstallation
NR66Series
(For peak �ow rates in shaded areas, contact Noritz for proper setting.)
TempRise (˚F)
(NC380)Series
NR111(NC250)Series
NRC111(NCC199)Series
NR98(NC199)Series
NR71Series
NR66Series
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
13.2
13.2
13.2
13.2
12.5
11.3
10.4
9.6
8.9
8.3
7.8
7.9
6.9
6.6
6.2
11.1
11.1
10.5
9.3
8.4
7.6
7.0
6.5
6.0
5.6
5.3
4.9
4.7
4.4
4.2
11.1
10.6
9.3
8.4
7.4
6.8
6.2
5.8
5.3
5.0
4.6
4.4
4.1
3.9
3.7
9.8
9.2
8.4
7.5
6.7
6.1
5.6
5.2
4.8
4.5
4.2
4.0
3.7
3.5
3.4
7.1
7.1
7.1
6.3
5.8
5.2
4.8
4.4
4.1
3.8
3.6
3.4
3.2
3.0
2.9
6.6
6.6
5.7
5.3
4.6
4.2
3.8
3.5
3.3
3.1
2.9
2.7
2.6
2.4
2.3(Model numbers in parenthesis are commercial models. Assuming a standard 2.5 GPM shower head and 105˚F output water temperature).
(NC380)
NR111(NC250)
NRC111(NCC199)
NR98(NC199)
NR71
NR66
Summer Water Supply 70˚FModel Winter Water Supply 45˚F
5.3Showers
4.2Showers
13.2 GPM
10.4GPM
4.4Showers
2.8Showers
11.1GPM
7.0GPM
4.1Showers
2.5Showers
10.6GPM
6.2GPM
3.7Showers
2.2Showers
9.2GPM
5.6GPM
2.8Showers
1.9Showers
7.1GPM
4.8GPM
2.6Showers
1.5Showers
6.6GPM
3.8GPM
Sizing Reference
SV SV
OD OD*Only available in the U.S.
Noritz Hydronic
Requirement TempActual TempBoiler Temp
Temp
Time
Wasted Energy
Unbalanced System/Uncomfortable Temperature
1st ASME certi�ed tankless hydronic boilers for residential & commercial applications.
Advanced features include:• Commercial-grade copper heat exchanger made thicker to help resist corrosion.
• Pipe with larger diameter specifically designed for the boiler dramatically reduces pressure loss through the multi-pass heat exchanger.
• Standard integrated priority controls for DHW and hydronic heating systems from a single controller on the front panel.
• Two temperature settings; 1 for the DHW and 1 for the heating system.
• High temperature capability (up to 180°F). Nine temperature option settings.
• Low maintenance – minimal moving parts (fan and flow switch only).
• Durable, fully solid state controls.
PLUMBING-HEATING-COOLINGCONTRACTORS ASSOCIATION
NH199-DV NH150-DV24.2” (H) x 18.3” (W) x 9.4” (Depth)
65 lbs./ 1” Water inlet & outlet, 3/4” gas65 lbs./ 1” Water inlet & outlet, 3/4” gas
Max. 150,000 Btuh- Min. 55,500 Btuh
Max. 150,000 Btuh- Min. 55,500 Btuh
45,500- 122,400 Btuh
Pressure & Temperature Gauge, Safety Relief Valve, Anchoring Screws, Terminals
83% (NG), 82.8% (LP)
24.2” (H) x 18.3” (W) x 9.4” (Depth)
Max. 199,900 Btuh- Min. 55,500 Btuh
Max. 199,900 Btuh- Min. 55,500 Btuh
45,500- 163,100 Btuh
Pressure & Temperature Gauge, Safety Relief Valve, Anchoring Screws, Terminals
82.7% (NG), 83% (LP)AFUE
Included Accessories
Dimensions
Weight/ Connections
NG
LP
Gas Consumption
Gas Consumption
Standard Output
Noritz Fully Modulating Burners The fully modulating burner on the NH Series tracks the needs of the system precisely and provides only the amount of energy required to maintain the system’s set point, reducing fuel consumption significantly.
DV DV
300 lbs +
Traditional non-condensing/ non-modulating boilerstake up valuable floor space and wastes energy.
The Noritz NH Series boiler is energyefficient & space saving.
Energy E�cient & Space Saving
66 lbs
Noritz NH Series Traditional Boilers
Noritz Commercial
ModularThe Noritz modular system is based on a single self-contained, interchangeable unit that can combine and communicate with like units to meet any hot water demand.
ModulationNoritz fully modulating technology can track any hot water demand with pin point accuracy, only using the energy necessary to heat the water that is used.
Intelligent SystemIn a multi-system setup, the Noritz commercial units will communicate with one
The Noritz Commercial Advantage
50%
0% 0%
80%
40%40%
24.4” (H) x 18.4” (W) x 9.4” (Depth)
62 lbs./ 3/4” Water inlet & outlet, gas62 lbs./ 3/4” Water inlet & outlet, gas
Max. 250,000 Btuh- Min. 11,000 Btuh
Max. 250,000 Btuh- Min. 11,000 Btuh
0.5-11.1 Gal./min.
Remote Control, & Cord, Anchoring Screws
84%84%
100-150˚F (in 5˚F Intervals), 160, 170,181.4˚F
24.4” (H) x 18.4” (W) x 9.4” (Depth)
Max. 250,000 Btuh- Min. 11,000 Btuh
Max. 250,000 Btuh- Min. 11,000 Btuh
0.5-11.1 Gal./min.
Remote Control & Cord, Anchoring Screws
100-150˚F (in 5˚F Intervals), 160, 170,181.4˚F
29.7” (H) x 19.1” (W) x 11.8” (Depth)
105 lbs./ 1” Water inlet & outlet, 3/4” gas
Max. 380,000 Btuh- Min. 22,500 Btuh
Max. 380,000 Btuh- Min. 22,500 Btuh
0.7-13.2 Gal./min.
Remote Control & Cord, Anchoring Screws
80% (NG), 84% (LP)
100-150˚F (in 5˚F Intervals), 160, 170,181.4˚F
NC380-SV-ASME NC250-SV-ASME NC250-DV-ASME
Thermal E�ciency
Temperature Settings
Included Accessories
Dimensions
Weight/ Connections
NG
LPGas Consumption
Capacity Range
SV
DV
The heater will turn on when the �ow is sensed.
1 heater will work solely until the demand grows greater than 80%.
The load will equalize among 2 or more heaters to meet high volume demand.
Single Unit
23 : 1 Turndown Ratio11,000- 250,000 BTU Range
24 Units (Modular)
545 : 1 Turndown Ratio11,000- 6 Million BTU Range
(Specs based on NC250 model)
Fully Modulating BurnerNoritz's fully modulating burner technology is the most precise and e�cient method of heating high �uctuating demands of water.
another and work in unison to even out the load on each individual unit, maximizing output and system life. With the ability to modulate between multiple units with the use of a system controller makes Noritz commercial water heaters the most e�cient water heating system on the market today.
SV
Noritz Commercial InstallationNoritz tankless water heaters were installed at the headquarters of a sunglass manufacturer in Lake Forest, CA. This job has a total of 25 NC380-SV-ASME with 10 multi-system units, and 15 multi-system units. These units supply hot water to 25 lens cleaning machines.
24.2” (H) x 18.3” (W) x 9.4” (Depth)
73 lbs./ 3/4” Water inlet & outlet, gas
Max. 199,900 Btuh- Min. 11,000 Btuh
Max. 199,900 Btuh- Min. 11,000 Btuh
0.5-11.1 Gal./min.
Remote Control & Cord, Anchoring Screws,Condensate Neutralizer
93%
100-150˚F (in 5˚F Intervals), 160, 170,181.4˚F
24.4” (H) x 18.4” (W) x 9.4” (Depth)
73 lbs./ 3/4” Water inlet & outlet, gas
Max. 199,900 Btuh- Min. 11,000 Btuh
Max. 199,900 Btuh- Min. 11,000 Btuh
0.5-11.1Gal./min.
Remote Control & Cord, Anchoring Screws, Condensate Neutralizer
93.3% (NG), 93.9% (LP)
100-150˚F (in 5˚F Intervals), 160, 170,181.4˚F
NCC199-SV NCC199-DV
DVC
DV OD
Condensing Condensing
NC199-DVC
100-150˚F (in 5˚F Intervals), 160, 170,181.4˚F
23.6” (H) x 13.8” (W) x 10.2” (Depth)
55 lbs./ 3/4” Water inlet, outlet & gas
Max. 199,900 Btuh- Min. 11,000 Btuh
Max. 199,900 Btuh- Min. 11,000 Btuh
0.5-9.8 Gal./min.
84%
Built-in Remote Control,Anchoring Screws
NC199-OD
100-150˚F (in 5˚F Intervals), 160, 170,181.4˚F
Remote Control & Cord, Anchoring Screws
23.6” (H) x 13.8” (W) x 9.4” (Depth)
47 lbs./ 3/4” Water inlet, outlet & gas
Max. 199,900 Btuh- Min. 12,000 Btuh
Max. 199,900 Btuh- Min. 12,000 Btuh
0.5-9.8 Gal./min.
84%
Advantages• RedundancyAny one of the Noritz commercial units on a multi-system can be taken o�ine and serviced without compromising your business. Hot water will still be provided by the other units.
• EfficiencyBecause of the modulating technology, a Noritz commercial system heats water using only the energy necessary to meet the demand, reducing energy consumption signi�cantly and saving on water heating costs.
• Versatile InstallationNoritz commercial units can be installed indoors or outdoors and because of its size and weight, they can be wall hung or racked, making spaces once thought impossible, possible.
Electric tank water heaters were previously used on this installation but were not able to supply the demand of the lens cleaning machines, which are operated twenty-four hours a day. The Noritz units are able to supply an endless stream of hot water and save much needed room within the building as well.
PLUMBING-HEATING-COOLINGCONTRACTORS ASSOCIATION
SV
Vertical Installation Snorkel Kit
Horizontal InstallationHorizontal- Kits Horizontal- Build Your Own
Wall Thickness RangeFrom 5.8"-13.2"
Wall Thickness RangeFrom 10.3"-17.8"
1
2
4
6
5
77
1
2
4
Direct connectionwithout straight
4
1
4
8
1
3
3Direct connectionwithout straight
4
Standard Wall KitIncludes inner & outer platesCVK-H
Thick Wall KitIncludes inner & outer platesCVK-H2
• CVK-V-F(0-15 Degrees)
• CVK-V-A(15-45 Degrees)
Vertical KitWarm Weather
CVK-V-F Contents
CVK-V-A Contents
Storm Collar
Storm Collar
No Description Part Number1
3
Rain Cap w/ Air Intake Pipe
Rain Cap w/ Air Intake Pipe
CRCAICSCR
Flat Roof Flashing (0-15 Degrees) CFRF
No Description Part Number123 Angled Roof Flashing (15-45 Degrees) CARF
2
CRCAICSCR
Features:• Push-on connection.• Single-wall penetration.• No need to cut- adjustable for easy installations.
• Zero clearance to combustibles.• Use of superior anti-corrosion material 316L for outlet port.• Heat and chemical resistant fluorine rubber O-ring for secure sealing.
No
Description
Part Number
1Straight Bird Screen
w/ Outer Plate
CVT-S
3
CWF
Straight Vent Pipe w/ Wall Flange
2
CWF-90ELB
90˚ Adj w/ Wall Flange
4
CVP-4/12/24/36STR
Straight
5
CVP-11/16/40ADJ
Adjustable
CVP-45/90ELB
6
45/ 90 Degree
CDT-V
7
Drain Tee
• CVK-V-CF(0-15 Degrees)
• CVK-V-CA(15-45 Degrees)
5
1
234
Vertical KitCold Weather
CVK-V-CF Contents
CVK-V-CA Contents
No Description Part Number12345
Rain Cap
Storm Collar
Storm Collar
CRCCAIP1CSCR
Flat Roof Flashing (0-15 Degress) CFRF
No Description Part Number12345
Rain Cap CRCCAIP1CSCR
Angled Roof Flashing (15-45 Degrees) CARF
Drain Tee CDT-V
Air Intake Pipe W/ Snap Connection
Air Intake Pipe W/ Snap Connection
Drain Tee CDT-V
13.2
- 15
.7 in
.
13.2
- 15
.7 in
.
5.3 in. 5.3 in.
Concentric Venting for DVC Models DVC
Part Number1 CVT-SNRK-90ELB2 CVP-90ELB3 CVP-90ADJELB4 CVP-16ADJ5 CVP-11ADJ6 CVK-SNRK-C-SUS7 SS-88 SS5-3ADJ
Snorkel Kit Contents
Termination elbow90 degree elbow
90 degree adjustable elbowVertical vent pipe
Horizontal vent pipeSnorkel case
Screw setSupport strap
DescriptionNo
Available February 2010
5.04 in.
7.89 in.1.57 in. 26.18 in.
1
2
3
Inner2.02.02.02.02.02.02.0
L1Outer
Inner Outer
Inner Outer
3” 5”
3” 5”
3” 5”
3” 5”
3” 5”
3.311.823.635.4
L
8.3-11.211.0-16.722.8-40.6
CONCENTRICVENT PIECES
Rigid
4” Straight12” Straight24” Straight36” Straight
11” Adjustable16” Adjustable40” Adjustable
45 Degree
90 Degree
AdjustableVent Length
Elbow
WallPiece
CondensationDrain
RoofPieces
(up to 55 degreeswith optional
piece)
Termination
Others
Roof FlashingPipe*
0 – 20 Degrees *(pitch roofs 4/12 pitch & less)
20-40 Degrees(5/12 – 10/12 pitch)
40-55 Degrees(11/12 pitch and 17/12)
Straight Bird Screenw/ Outer Plate
(FP-5-OUT) Outer Plate
Concentric VentOuter Plate
Inner Outer
3” 5”Air IntakePipe with Thread*
L2
L
L1L2
90 DegreeAdjustable
Elbow
90 DegreeAdjustable
Elbow w/ Wall Flange3” 5”
3” 5”
3” 5”
3” 5”
L
L
L1
L2
L2
LL1
18.5
L
8.3
23.6
10.9
L1
0.47
3.0
Inner Outer
L1
17.3
17.3
L2
8.1
14.5
L3
25.3
29.1
20˚
40˚
Inner Outer
3” 5”
Straight Vent Pipe
w/ Wall Flange
12.6~15.8
L2
L2
2.2
4.9
12.6~15.8
L
8.7
L
L
5.3
8.1
4.9
8.7
D
D
L1
L1
2.0
2.0
2.0
2.0
L1
Rain Cap*
H
H
19.9 4.9
L1
L1 L
L1
10.6
L2
L2
L3
L2
L31.6
D1
D1
3.1
D
D
6.0
3.9 1.1 11.0
A
H D
L1 L2 L
ADSIZE
Support Strap 2
Vertical Drain Tee
0.6
5.0 6.0
8.7
Note: The DVC water heater and vent pipe are considered one system and have been approved as such. The DVC-Vent Line is approved for use on Noritz products only. *CRF-20 is required for installation.
H6.87.89.8
11.8
C1”2”4”6”
Part Name Type Description Drawing Dimensions (inches)Diameter
1
5 Sets5 Sets5 Sets5 Sets
6
1
1
1
1
1
1
6
6
6
6
6
6
6666666
Qty/Box
FP-5-OUT
SS5-1SS5-2SS5-4SS5-6
CVT-S
CRC
CRFA-40(req. CRF-20)
CRFB-55(req. CRF-20)
CRF-20
CRFP
CAIP
CDT-V
CWF-90ELB
CVP-90ADJELB
CWF
CVP-45ELB
CVP-90ELB
CVP-4STRCVP-12STRCVP-24STRCVP-36STRCVP-11ADJCVP-16ADJCVP-40ADJ
Part Number
Concentric Venting for DVC Models DVC
*must be purchased together
Noritz N-Vent is available in three sizes: 3”, 4” and 5”. N-Vent is UL-Listed and ideal for tankless installations such as direct vent, horizontal, vertical and outdoor applications. Adjustable venting o�ers �exibility for di�erent vent runs.
The N-Vent Termination Kits
The Line-up: 3”, 4” & 5”
Noritz N-Vent is UL approved Category III venting. Underwriter’s Laboratories (UL), an independent not-for-pro�t product safety testing and certi�cation organization is one of the most recognized safety agencies in the world. N-Vent is approved for tankless and boiler stainless steel exhaust installations at a fraction of the industry standard cost.
UL Listed
N-Vent Horizontal Vent KitVK4-H-*Speci�cations & Features• Stainless Steel• 4” Diameter• Flexibility for different wall thicknesses• Easy installation• Professional appearance
N-Vent Vertical Vent KitVK4-V1Speci�cations & Features• Stainless Steel• 4” Diameter• Easy installation• Professional appearance
Noritz supplies easy-to-connect venting components- the most simple in the industry to install. Unlike other brands, there’s no need to tighten as the Noritz N-Vent
Easy Connection
has a Quick-Snap feature that allows for an easy connection while forming a tight seal. In addition, Noritz o�ers a special appliance adapter that connects N-Vent components to other manufacturers’ tankless heaters or boilers.
Wall Thickness4.1”- 7.4”7.4”- 14”
DescriptionWall Thimble with Built-in
Hood Termination90 Degree Elbow
7”- 9.4” Adjustable Vent
Description
Drain Tee
90 Degree Elbow
Firestop
Support Clamp
Roof Jack
Storm Collar Pipe
Rain Cap
9”- 13.4” Adjustable Vent
Part Number
DT4
VP4-90ELB
FS4
SC4
RJ4
SCP4
RC4
VP4-13.4ADJ
Quantity
1
2
1
1
1
1
1
1
Part NumberWT4-H-#-1 (# Based on wall thickness)
VP4-90ELB)
VP4-9.4ADJ
Quantity1
1
1
*Venting Kit NumberVK4-H-8-1
VK4-H-14-1
Stainless Steel Venting for SV and DV Models DVSV
N-Vent Direct Vent Long TerminationSpeci�cations & Features• Stainless Steel• 4” Diameter• Easy installation• Professional appearance
Use a listed Category III vent adaptor to connect the flue collar to the vent system. Use Category III vent pipe for the entire length of the exhaust pipe.
**Sleeve and termination (L2) can be adjusted in increments of 0.4 inch
Components included in the Termination Kits are shown in bold and listed in the charts. Note: Additional venting components will be needed to complete most vent runs. **Sleeve and termination (L2) can be adjusted in increments of 0.4 inch
N-Vent Direct Vent Short TerminationSpeci�cations & Features• Stainless Steel• 4” Diameter• Easy installation• Professional appearance
Part Name Type Description Drawing Size DimensionsD
D L1 L D1
3
4
5
3.0
4.0
5.0
3.0
3.0
3.0
4.0
4.0
4.0
5.0
5.0
5.0
2.0
2.1
2.7
3
3
4
4
3
4
5
3
4
5
5
L1 LPart Number QTY/Box
6” Straight12” Straight24” Straight36” Straight48” Straight
7”- 9.4” Adjustable9”- 13.4” Adjustable
13”- 21.4” Adjustable36”- 60” Adjustable
Rigid
VENT PIPE
AdjustableVent
Length
Adapter Appliance Adapter
Flexible 18” Flexible
Elbow 45 Degrees
Elbow 90 Degrees
12.024.035.448.06.0
11.823.635.548.06.0
11.823.635.548.0
14.026.037.450.07.9
13.925.737.550.18.6
14.526.338.150.7
VP3- 12STRVP3-24STRVP3-36STRVP3-48STRVP4- 6STR
VP4- 12STRVP4-24STRVP4-36STRVP4-48STRVP5- 6STR
VP5- 12STRVP5-24STRVP5-36STRVP5-48STR
VP3- 9.4ADJVP3- 13.4ADJVP3- 21.4ADJVP3-60.0ADJVP4- 9.4ADJ
VP4- 13.4ADJVP4- 21.4ADJVP4- 60.0ADJVP5- 9.4ADJ
VP5- 13.4ADJVP5-21.4ADJ
66666666666666666666666666
6
6
6
6
6
66
6
6
6.8”- 9.1”9.5”- 14.6”
15.4”- 26.5”36.0”- 60.0”
6.8”- 9.1”9.5”- 14.6”
15.4”- 26.5”36.0”- 60.0”
6.8”- 9.1”9.5”- 14.6”
15.4”- 26.5”
2.0
2.1
2.7
2.0
2.1
2.7
3.6
4.0
5.4
5.2
6.2
7.9
VP3- 45ELB
VP4- 45ELB
VP5- 45ELB
VP3- 90ELB
VP4- 90ELB
VP5- 90ELB
VP3-ADAPT-1VP4-ADAPT-1
17.7
17.7
4.0
5.0
4
5
19.8
20.4
VP4- 18FLEX
VP5-18FLEX
3.04.0
1.21.2
4.94.9
3.24.0
Part Name
VentTermination
Part Name
VentTermination
Type
Long
Type
Long
3.5”- 5.1”
5.1”- 8.3”
8.3”- 14.6”
14.6”- 27.2”
3.5”- 5.1”
5.1”- 8.3”
8.3”- 14.6”
14.6”- 27.2”
3.5”- 5.0”
5.0”- 8.0”
8.0”- 15.0”
15.0”- 27.0”
3.5”- 5.0”
5.0”- 8.0”
8.0”- 15.0”
15.0”- 27.0”
7.0”- 8.5”
8.5”- 12.0”
12.0”- 18.0”
18.0”- 30.5”
7.0”- 8.5”
8.5”- 12.0”
12.0”- 18.0”
18.0”- 30.5”
VT4-TL-5
VT4-TL-8
VT4-TL-14
VT4-TL-27
VT4-TS-5
VT4-TS-8
VT4-TS-14
VT4-TS-27
1
1
1
1
1
1
1
1
Wall Thickness
Wall Thickness
Dimensions (inches)
Dimensions (inches)
Sleeve**
Sleeve**
Termination** (L2)
Termination** (L2)
Part Number
Part Number
Qty/ Box
Qty/ Box
Stainless Steel Venting for SV and DV Models DVSV
Straight Birdscreen
HorizontalVENT
TERMINATION
VENTTERMINATION
CONDENSATIONDRAIN
ROOF PIECE
Horizontal
Horizontal
Vertical
Vertical
45 Degree Birdscreen
Hood
Louver
Rain Cap
Drain Tee
Vertical Drain Tee
Flat Roof Flashing
Angled Roof Flashing
Roof Jack
Storm Collar Pipe
Storm Collar
Part Name Type Description Drawing Dimensions (inches)D L1 L
3.04.05.0
2.02.12.0
5.96.27.9
4.0
5.0
2.1
2.7
4.0
5.4
L5.5
6.1
6.6
3.2
3.7
6.8
6.6
7.2
D13.2
7.4
7.4
7.4
7.4
6.3
7.8
11.0
Size
345
3
4
5
4
5
4
5
3
4
5
3
4
5
3
4
5
4
5
3
4
5
3
4
5
4
5
3
4
D
3.0
4.0
5.0
4.0
5.0
3.0
4.0
5.0
3.0
4.0
5.0
3.0
4.0
5.0
5.3
6.3
B
5.0
6.0
7.0
4.0
5.0
6.0
D
4.0
5.0
3.0
4.0
7.1
7.2
8.0
L
5.1
5.1
6.2
C
17.0
18.0
16.0
17.0
18.0
23.6
25.2
H
3.0
4.0
Part Number
VT3-SH
VT4-SH
VT5-SH
VT3-SVT4-SVT5-S
VT4-S45
VT5-S45
VT4-SL
VT5-SL
RC3
RC4
RC5
DT3
DT4
DT5
DT3-V
DT4-V
DT5-V
FRF4
FRF5
ARF3
ARF4
ARF5
RJ3
RJ4
RJ5
SCP4
SCP5
SCR3
SCR4
L1
1.8
2.1
2.8
2.1
2.8
2.0
2.0
2.0
2.0
2.1
2.7
L1
2.0
2.1
2.7
H
11.5
11.5
6.0
6.0
6.0
18.0
18.0
18.0
7.8
8.9
A
7.8
7.9
6
6
1
1
6
6
6
1
1
1
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
Qty/Box
6
6
666
Stainless Steel Venting for SV and DV Models DVSV
Horizontal
Size
D3.44.45.4
15.018.020.4
C
Termination** (L2)
345
3.04.05.0
6.06.07.0
Size
D
D A H C
C
5.0- 6.07.0- 9.0
9.0- 14.54.1- 7.86.0- 7.07.0- 8.0
8.0- 10.310.5- 14.5
5.0- 6.06.0- 7.07.0- 8.0
8.0- 10.310.5- 14.5
D1
4.84
L1
.281
E
G
CDB
F
0- 3.10- 5.80- 8.10- 4.8
0- 5.60- 11.1
0- 6.60- 9.6
1.5
Horizontal
DIRECTVENT
TERMINATION
OUTDOORVENT CAP
Part Name
WALLPENETRATION
WALLTERMINATION
SUPPORT
FIRE STOP Vertical Fire Stop
DirectVent
Long
Short
3.5”- 5.1”
5.1”- 8.3”
8.3”- 14.6”
14.6”- 27.2”
Sleeve**
D
7.84
3.5”- 5.0”
5.0”- 8.0”
8.0”- 15.0”
15.0”- 27.0”
3.5”- 5.0”
5.0”- 8.0”
8.0”- 15.0”
15.0”- 27.0”
7.0”- 8.5”
8.5”- 12..0”
12.0”- 18.0”
18.0”- 30.5”
7.0”- 8.5”
8.5”- 12..0”
12.0”- 18.0”
18.0”- 30.5”
3.5”- 5.1”
5.1”- 8.3”
8.3”- 14.6”
14.6”- 27.2”
Vent SleeveCover
Type
Strap
Wall Thimble
Vent Cap
AdjustableWall Thimble
w/ Built-inHood Termination
Clamp
Description Drawing Dimensions (inches)
4.0
7.0
10.7
B
3.1
4.0
5.0
D
6.0
10.0
12.2
C
3
4
5
Size
1
1
1
Qty/Box
Size D E F G
3
4
5
3
4
5
3.0
4.0
5.0
4.0
4.7
6.0
4.65.66.67.65.76.68.7
10.76.87.89.8
11.8
1”2”3”4”1”2”4”6”1”2”4”6”
3.0
4.0
5.0
5.8
B
6.5
7.1
10.7
11.0
C
9.0
10.0
12.2
7.97.9
B
18.9
6.26.2
H
7.6
FS3FS4FS5
FP-4
VT4-TL-5
VT4-TL-8
VT4-TL-14
VT4-TL-27
SC3SC4SC5
VT4-TS-5
VT4-TS-8
VT4-TS-14
VT4-TS-27
SS3-1SS3-2SS3-3SS3-4SS4-1SS4-2SS4-4SS4-6SS5-1SS5-2SS5-4SS5-6
VC-3VC-4-1
WT3-H-6WT3-H-9
WT3-H-14WT4-H-8-1
WT4-H-6WT4-H-7
WT4-H-10WT4-H-14WT5-H-5WT5-H-6WT5-H-7
WT5-H-10WT5-H-14
WT3
WT4
WT5
Part Number
VC-132
666
1
1
1
1
5 Sets5 Sets5 Sets
5 Sets5 Sets5 Sets5 Sets5 Sets5 Sets5 Sets5 Sets5 Sets5 Sets5 Sets5 Sets
66
1111111111111
1
1
1
1
1
1
**Sleeve and termination (L2) can be adjusted in increments of 0.4”
Stainless Steel Venting for SV and DV Models DVSV
Vertical Vent TerminationPVC/CPVC Materials Only
Fire stop
Fire stop/Support
RoofFlashing
StormCollar
HangerStrap
PVC/CPVCAdapter*
**1' Min
* Not supplied with water heater, order separately.
**1' minimum recommended,but not required.
Support
Insert BirdScreen* inend of 45 ° elbow
PVC/CPVCCoupling
Slope ventUpwards
(NCC199 Series Only)
(VT_-PVCS )
Horizontal Vent Termination- PVC/CPVC Materials Only
PVC/CPVCAdapter*
HangerStraps
**1' Minimum
Slope ventUpwards
* Not supplied with water heater, order separately.
**1' minimum recommended,but not required.
Insert BirdScreen* ineach end of tee
Insert BirdScreen* ineach end of tee
PVC/CPVCCoupling
(VP4-ADAPT-PVC)
(VT_-PVCS )
(VT_-PVCS )
1for NCC199 & NRC111 only.2items required for use with PVC venting. 3for NCC199-DV only.
VP4-ADAPT-PVC (4”)
VC-4C VP4x3-ADAPT-PVC (3”)
VT3-PVCS (3”) VT4-PVCS (4”) VT4-TS-ADAPT
Outdoor Vent Cap(VC-4C)
NCC199 & NRC111 PVC Vent Pieces
PVCV E N T I N G
ZERO CLEARANCE
VK3-H-PVCSpeci�cations & Features:3” Diameter for intake/exhaust5” Diameter for terminationEasy Installation
3” PVC Concentric Horizontal Termination Kit
39”
5”3”
3”
Follow all vent system requirements in accordance with relevant local or state regulation, or, in the absence of local or state code, the National Fuel Gas Code ANSI Z233.1/NGPA 54- latest edition.
(NCC199-DV & NRC111-DV only)
(NCC199 Series Only)
Part NumberDescription
Outdoor Vent Cap1
PVC Adapter2
Bird Screen for PVC2
Short Termination Adapter3
(For NCC199 Series Only)
Tax Credit/ Rebate InformationLocal Utility Rebates
Many local utility companies are recognizing the bene�ts of tankless water heaters and are encouraging this through rebates.Check with your installer, local utility company or www.noritz.com/1500 for available rebates.
Federal Tax CreditThe Federal tax credit allows homeowners who install any of our ENERGY STAR models to claim 30% of the full purchase and installation price up to a maximum of $1500. Units must be installed by December 31, 2010.
PVC Venting for Condensing Models
WarrantyResidential
Warranty
CommercialWarranty
BoilerWarranty
Noritz o�ers a 12-year residential warranty on the heat exchanger, a 5-year warranty on parts and 1-year reasonable labor. (Labor will be paid to an authorized Noritz Service Representative on pre-approved warranty repairs.)
Noritz o�ers a 5-year warranty on the heat exchanger and a 5-year warranty on parts.
Noritz o�ers a 10-year warranty on the heat exchanger and a 1-year warranty on parts.
12 Years
5 Years
10 Years
NR66Accessories Descriptions Part Number
NR71 NR98NRC111NCC199
NR111NC250
NC199 NC380 NH
Remote Controller
Remote ControllerCord
RC-7649MRC-7650M (CAN)
NCC199 NCC199
RC-CORD26
0700757
RC-CORD10
Pipe Covers
RC Outdoor Junction Box
QC-1
SC-201-6M
SC-201-12M
SC-201-24M
IK-WV-7-TH
IK-WV-7-SW
IK-WV-8-TH
IK-WV-8-SW
IK-WV-9-TH
IK-WV-9-SW
IK-AK-2
RB-500
RB-600
RB-700
RB-900
SS-HB-1
SS-HB-2
HBC-1
HBC-2
TPG1-30
HTGSRV-1
HGA-1
Quick-Connect Cable
System ControllerUp to 6 units
Up to 12 Units
Up to 24 Units
Isolation Valves(Includes Pressure
Relief Valve)
Isolation Valve Adapter
Remote Controller
10’ Length
26’ Length
RC-OJB
Pipe Cover
Pipe Cover
Pipe Cover
Stainless Steel
Stainless Steel
Pipe Cover
2-units only
PC-1S
PC-2S
PC-3S
PC-3S-SUS
PC-4S-SUS
PC-5S
Isolation Valves
Recess Box
NR66-OD
NR71-OD
NR98-OD
NR111-OD
ScaleShield ScaleShield
1 Each
1 Each
(75 PSI, 320˚ F)
Safety Relief Valve
Concentrate (2.68 Gal)
ScaleShield Re�ll Cartridges
Temp/Pressure GaugeSafety Relief Valve
Anti-Freeze
199
*
*
OD
*
*
***
DV
*
*
OD
*
*
DV
*
*
DVC
OD
*
*
SV
*
*
**
**
DVC
*
*
***
SV
*
*
SV
*
*
NCC199 NCC199
NCC199 NCC199
NCC199 NCC199
NRC111 NRC111
SV
*
*
SV
SV
OD
OD
150
*
*
SV= Standard Vent, DV= Direct Vent, OD= Outdoor Model, DVC= Concentric Vent * Included with heater purchase. ** Two units required. *** RC-Cords will need to be purchased.
Remote Controller Outdoor Junction Box Temp/ Pressure GaugeRecess Box ScaleShieldPipe Cover Isolation Valves
Accessories
Noritz Showrooms & O�ces
2010 JANUARY© 2010 Noritz America® Corporation. All rights reserved.
Headquarters11160 Grace Avenue
Fountain Valley, CA 92708Fax: (714) 241-1196
Atlanta1220 Kennestone Circle, Ste 126Marietta, GA 30066Fax: (770)422-0184
Chicago861 Busse RoadElk Grove Village, IL 60007Fax: (847) 472-6885
Dallas720 Industrial Blvd., Ste 200Grapevine, TX 76051Fax: (817) 421-0033
New York12 Skyline DriveHawthorne, NY 10532Fax: (914) 345-3288
www.noritz.com/proToll Free: (888) 382- 6568
top related