6sl3224 0xe42 0ua0 datasheet en
Post on 28-Feb-2018
221 Views
Preview:
TRANSCRIPT
-
7/25/2019 6SL3224 0XE42 0UA0 Datasheet En
1/2
6SL3224-0XE42-0UA0
Data sheet for SINAMICS Power Module PM240
Ordering data
Figure similar
Rated data
Ambient conditions
General tech. specifications
Input
Output
Ambient temperature
Relative humidity
Number of phases
Max. operation
Storage
Transport
Operation LO
Cooling air requirement
Cooling
Installation altitude
Rated power (LO)
Rated voltage
Number of phases
Line voltage
Line frequency
Rated current with line reactor
Rated current without line reactor
Rated power (HO)
Power factor
Offset factor cos
Sound pressure level (1m)
Power loss
Rated current (LO)
Pulse frequency
Rated current (HO)
Max. output current
Output frequency for V/f control
Overload capability
Output frequency for vector control
200.00 kW / 300.00 hp
250.00 kW / 400.00 hp
400 V
2 kHz
0.95
69 dB
5.50 kW
477.00 A
370.00 A
592.00 A
442.00 A
354.00 A
0.360 m/s
1000 m
Internal air cooling
1.1 output current rating (i.e., 110 % overload) for 57 s with a cycle t ime of 300 s 1.5 output current rating (i.e., 150 % overload) for 3 s with a cycle time of 300 s
Consignment no. :
Remarks :
Item no. :
Offer no. :Order no. :
Project :
Client order no. :
1.36 output current rating (i.e., 136% overload) for 57 s with a cycle time of 300 s 1.6 output current rating (i.e., 160% overload) for 3 s with a cycle time of 300 s
3 AC
3 AC
380 ... 480 V 10 %
47 ... 63 Hz
0 ... 200 Hz
0 ... 550 Hz95 % RH, condensation not permitted
-25 ... 55 C (-13 ... 131 F)
-40 ... 70 C (-40 ... 158 F)
0 ... 40 C (32 ... 104 F)
0.85
High Overload (HO)
Low Overload (LO)
Operation HO 0 ... 40 C (32 ... 104 F)
Efficiency 0.98
Technical data are subject to change! There may be discrepancies between calculated and rating plate values.Generated Sat Feb 20 23:58:00 CET 2016Page 1 of2
-
7/25/2019 6SL3224 0XE42 0UA0 Datasheet En
2/2
6SL3224-0XE42-0UA0
Data sheet for SINAMICS Power Module PM240
Ordering data
Figure similar
Compliance with standards
CE marking
Standards
According to low-voltage directive2006/95/EC
UL, cUL, CE, C-Tick (RCM), SEMI F47
Mechanical data
547.0 mm
Degree of protection IP20
326.0 mm
Height
Net weight 174.00 kg
Depth
Size
Width
1533.0 mm
FSGX
M10 bolt
Version
Unshielded 300 m
Version
185.00 ... 240.00 mm
Max. motor cable length
Conductor cross-section
Connections
M10 bolt
Motor end
200 m
Line side
Conductor cross-section
185.00 ... 240.00 mm
Shielded
Converter losses to EN 50598-2*
Comparison with the reference converter (90% /100%)
Efficiency class
-58.01 %
IE2
3000.7 W (0.91 %)
5731.3 W (1.73 %)
f
4703.0 W (1.42 %)
25%
100%
2655.1 W (0.80 %)
4037.3 W (1.22 %)
1868.1 W (0.57 %)
50%
1978 W (0.60 %)
50%2401.0 W (0.73 %)
90%
I
The diagram shows the losses for the points (as per standard EN 50598) of the relative torque
generating current (I) over the relative motor stator frequency(f). The values are valid for the basic
version of the converter without options/components.
The percentage values show the losses in relation to the rated apparent power of the converter.
*calculated values; increased by 10% according to the standard
Technical data are subject to change! There may be discrepancies between calculated and rating plate values.Generated Sat Feb 20 23:58:00 CET 2016Page 2 of2
top related