Publication Number: 53-1000205-01 Rev. A
iSCSI GatewayHardware Installation and
Operation Guide
Supporting Brocade iSCSI Gateway
-
8/18/2019 Brocade ISCSI Gateway v326 HW Install
2/26
Copyright © 2006, SANRAD, Inc..
ALL RIGHTS RESERVED. Publication Number: 53-1000205-01 Rev. A
This manual contains information that is proprietary to SANRAD. No part of this publication may be reproduced in any
form whatsoever without prior written approval by SANRAD.
Right, title and interest, all information, copyrights, patents, know-how, trade secrets and other intellectual property or
other proprietary rights relating to this manual and to the StoragePro Management System and any software componentscontained therein are proprietary products of SANRAD protected under international copyright law and shall be and
remain solely with SANRAD.
StoragePro Management System is a registered trademark of SANRAD. No right, license, or interest to such trademark
is granted hereunder, and you agree that no such right, license, or interest shall be asserted by you with respect to such
trademark.
Brocade, the Brocade B weave logo, Secure Fabric OS, and SilkWorm are registered trademarks and Tapestry is a
trademark of Brocade Communications Systems, Inc., in the United States and/or in other countries. All other brands,
products, or service names are or may be trademarks or service marks of, and are used to identify, products or services of
their respective owners.
Notice: The information in this document is provided “AS IS,” without warranty of any kind, including, without
limitation, any implied warranty of merchantability, noninfringement or fitness for a particular purpose. Disclosure of
information in this material in no way grants a recipient any rights under Brocade's patents, copyrights, trade secrets orother intellectual property rights. Brocade reserves the right to make changes to this document at any time, without
notice, and assumes no responsibility for its use.
The authors and Brocade Communications Systems, Inc. shall have no liability or responsibility to any person or entity
with respect to any loss, cost, liability, or damages arising from the information contained in this book or the computer
programs that accompany it.
Export of technical data contained in this document may require an export license from the United States Government.
Brocade Communications Systems, Incorporated
Document History
Corporate Headquarters
Brocade Communications Systems, Inc.
1745 Technology DriveSan Jose, CA 95110
Tel: 1-408-333-8000
Fax: 1-408-333-8101
Email: info@brocade.com
Asia-Pacif ic Headquarters
Brocade Communications Singapore Pte. Ltd.
9 Raffles Place#59-02 Republic Plaza 1
Singapore 048619
Tel: +65-6538-4700
Fax: +65-6538-0302
Email: apac-info@brocade.com
European and Latin American Headquarters
Brocade Communications Switzerland Sàrl
Centre Swissair
Tour A - 2ème étage
29, Route de l'Aéroport
Case Postale 105
CH-1215 Genève 15
Switzerland
Tel: +41 22 799 56 40Fax: +41 22 799 56 41
Email: emea-info@brocade.com
Document Title Publication Number Summary of Changes Publication
Date
Brocade iSCSI Gateway
Hardware and Installation and
Operation Guide
53-1000205-01 Rev. A New document March 2006
-
8/18/2019 Brocade ISCSI Gateway v326 HW Install
3/26
Regulatory Information
FCC-15 User Information
The Brocade iSCSI Gateway has been tested and found to comply with the limits of the Class A digitaldevice, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protectionagainst harmful interference when the Brocade iSCSI Gateway is operated in a commercialenvironment. The Brocade iSCSI Gateway generates, uses and can radiate radio frequency energy and,if not installed and used in accordance with the instruction manual, may cause harmful interference tothe radio communications. Operation of the Brocade iSCSI Gateway in a residential area is likely tocause harmful interference in which case the user will be required to correct the interference at theuser’s own expense.
Warning per EN 55022
The Brocade iSCSI Gateway is a Class A product. In a domestic environment, this product may causeradio interference, in which case the user may be required to take adequate measures.
Waste Electrical and Electronic Equipment WEEE) Directive
The WEEE directive places an obligation on manufacturers to take back electronics productsat the end of their useful life. For information about the directive and disposal of wasteequipment in the European Union, visit this Web site:http://www.brocade.com/support/WEEEcompliance.jsp
Safety Notices
Read and understand the following notices before installing the Brocade iSCSI Gateway.The power plug must be accessible at all times because it serves as the maindisconnecting vehicle.
Unplug the gateway power cord before performing maintenance procedures.
Do not touch the power supplies when their power cords are connected. Line voltagesare present within the power supplies when their cords are connected.
The safety cover is an integral part of this product. Do not operate the unit without thesafety cover firmly in place. Operating the unit without the cover in place will invalidatethe safety approvals and pose a risk of fire and electrical hazards.
This product relies on the building’s wiring for short-circuit (overcurrent) protection.Ensure that a fuse or circuit breaker no larger than 120 VAC, 15a U.S. (240 VAC, 10Ainternational) is used on the phase conductors (all current-carrying conductors).
The Brocade iSCSI Gateway is intended to be grounded. Ensure that the gateway isconnected to earth ground during normal use.
There is a danger of explosion if the motherboard battery is replaced incorrectly.Replace the battery with the same or an equivalent type as recommended by themanufacturer. Dispose of the used battery according to the manufacturer’s instructions.
http://www.brocade.com/support/WEEEcompliance.jsphttp://www.brocade.com/support/WEEEcompliance.jsp
-
8/18/2019 Brocade ISCSI Gateway v326 HW Install
4/26
-
8/18/2019 Brocade ISCSI Gateway v326 HW Install
5/26
Brocade iSCSI Gateway Hardware Installation and Operation Guide iPublication Number: 53-1000205-01
Contents1
About this Guide....................................................................................................................... 1
2 Before You Begin ...................................................................................................................... 1
Shipping Box Contents.............................................................................................................................2
3 Mounting the Brocade iSCSI Gateway......................................................................................3
Single Mounting in Rack ..........................................................................................................................4 Dual Mounting in Rack ............................................................................................................................6
Surface Mounting the Brocade iSCSI Gateway ......................................................................................9
4
Brocade iSCSI Gateway........................................................................................................... 10
Front Panel..............................................................................................................................................10 Back Panel...............................................................................................................................................10 System Indicator LEDs.............................................................................................................................11 Storage Port Connection ....................................................................................................................... 12 Network Port Connection ..................................................................................................................... 13 Console Port Connection...................................................................................................................... 14 Powering Up ........................................................................................................................................... 15
5
Getting Started ........................................................................................................................ 16
Configuration of Storage Devices ......................................................................................................... 16 Brocade iSCSI Gateway Initial Configuration....................................................................................... 17 Working with Brocade iSCSI Gateway Manager.................................................................................. 18
-
8/18/2019 Brocade ISCSI Gateway v326 HW Install
6/26
ii Brocade iSCSI Gateway Hardware Installation and Operation GuidePublication Number: 53-1000205-01
FiguresFigure 1. Single Rack Mount ..........................................................................................................................4 Figure 2. Attaching Single Brocade iSCSI Gateway to Rack.........................................................................5 Figure 3. Dual Rack Mount for Left Brocade iSCSI Gateway .......................................................................6 Figure 4. Dual Rack Mount for Right Brocade iSCSI Gateway.....................................................................7 Figure 5. Attaching Left to Right Brocade iSCSI Gateway (dual mounting) ................................................8 Figure 6. Attaching dual Brocade iSCSI Gateway to Rack............................................................................9 Figure 7. Brocade iSCSI Gateway Front Panel ............................................................................................10 Figure 8. Brocade iSCSI Gateway Back Panel .............................................................................................10 Figure 9. Brocade iSCSI Gateway LEDs ........................................................................................................11 Figure 10. Brocade iSCSI Gateway Storage Ports ......................................................................................... 12 Figure 11. Brocade iSCSI Gateway Network Ports ....................................................................................... 13
Figure 12. Brocade iSCSI Gateway Console Port.......................................................................................... 14 Figure 13. Brocade iSCSI Gateway Power Supply........................................................................................ 15
Tables
Table 1. Brocade iSCSI Gateway Indicator LEDs ........................................................................................11 Table 2. FC Storage Port Connection Types .............................................................................................. 12 Table 3. Network Port Cable Connections................................................................................................ 13 Table 4. Pre-installation Checklist..............................................................................................................16
-
8/18/2019 Brocade ISCSI Gateway v326 HW Install
7/26
About this Guide Shipping Box Contents
Brocade iSCSI Gateway Hardware Installation and Operation Guide 1Publication Number: 53-1000205-01
1
About this Guide
This guide provides instructions on how to mount the Brocade iSCSI Gateway and perform the basicinitial configuration for the gateway operating with the Brocade iSCSI Gateway Manager in a SANenvironment. This guide is intended as a supplement to the additional configuration informationdescribed in the Brocade iSCSI Gateway documentation provided on the CD-ROM. The most recentdocumentation and Release Notes can be obtained from http://www.brocade.com.
2
Before You Begin
Before you begin to install the Brocade iSCSI Gateway, follow these steps:
1. Unpack and remove the gateway and accessory kit from the shipping box.
3. , page 2. If any itemis missing or damaged, contact your Brocade distributor for instructions.
2. Save the packing material and box for future use.
Verify that you have received all the items listed in Shipping Box Contents
-
8/18/2019 Brocade ISCSI Gateway v326 HW Install
8/26
Shipping Box Contents Before You Begin
2 Brocade iSCSI Gateway Hardware Installation and Operation GuidePublication Number: 53-1000205-01
Shipping Box Contents
Additional Necessary Hardware and Tools not supplied)
Additionally, you will need the following to rack-mount the Brocade iSCSI Gateway:
Rack-post screw suitable for the equipment rack.Philips screwdrivers suitable for all the screws.
-
8/18/2019 Brocade ISCSI Gateway v326 HW Install
9/26
Mounting the Brocade iSCSI Gateway Shipping Box Contents
Brocade iSCSI Gateway Hardware Installation and Operation Guide 3Publication Number: 53-1000205-01
3
Mounting the Brocade iSCSI Gateway
The Brocade iSCSI Gateway can be surface or rack mounted in a 19” rack.
Mounting the Brocade iSCSI Gateway as a single unit in a 19” rack is described in SingleMounting in Rack, page 4.
Two gateways can be joined and mounted together in a single 1U space in a 19” rack and isdescribed in Dual Mounting in Rack, page 6.
Mounting the Brocade iSCSI Gateway on a flat surface is described in Surface Mounting theBrocade iSCSI Gateway, page 9.
-
8/18/2019 Brocade ISCSI Gateway v326 HW Install
10/26
Single Mounting in Rack Mounting the Brocade iSCSI Gateway
4 Brocade iSCSI Gateway Hardware Installation and Operation GuidePublication Number: 53-1000205-01
Single Mounting in Rack
Attaching the Brackets to the Brocade iSCSI Gateway
Figure 1 shows the bracket assembly for mounting a single gateway in a 19” rack.
1. Attach the left front L-Bracket (MFD 93590) to the gateway (refer to 1, Figure 1) with four of theincluded screws (FDBD-0407CSB).
2. Attach the long arm L-Bracket (MFD-93593) to the gateway (refer to 2, Figure 1) with four ofthe included screws (FDBD-0407CSB).
3. Attach the rear L-Bracket (MFD 93595) to the left side of the gateway (refer to 3, Figure 1) withtwo of the included screws (FDBD-0407DSC-A). Make sure that you adjust the rear bracketto that the unit fits your rack’s depth.
Figure 1. Single Rack Mount
-
8/18/2019 Brocade ISCSI Gateway v326 HW Install
11/26
Mounting the Brocade iSCSI Gateway Single Mounting in Rack
Brocade iSCSI Gateway Hardware Installation and Operation Guide 5Publication Number: 53-1000205-01
Attaching the single Brocade iSCSI Gateway to the rack mounting posts
1. Insert the rear of the gateway between the rack mounting posts until the L-Brackets touch therack mounting posts (Figure 2).
2. Align the mounting holes on the L-Brackets with the mounting holes on the rack mountingposts (Figure 2).
3. Using screws that you provide, attach the gateway to the rack mounting posts through theL-Brackets and into the threaded holes in the rack mounting posts (Figure 2).
4. Make sure that the gateway is level.
Figure 2. Attaching Single Brocade iSCSI Gateway to Rack
-
8/18/2019 Brocade ISCSI Gateway v326 HW Install
12/26
Dual Mounting in Rack Mounting the Brocade iSCSI Gateway
6 Brocade iSCSI Gateway Hardware Installation and Operation GuidePublication Number: 53-1000205-01
Dual Mounting in Rack
Attaching the Brackets to the Left Brocade iSCSI Gateway
The bracket assembly for the left gateway is shown in Figure 3.
1. For the left gateway, attach the left front L-Bracket (MFD 93590) to the gateway (refer to 1,Figure 3) with four of the included screws (FDBD-0407CSB).
2. Attach the right bracket (MFD 93591) to the right side of the gateway (refer to 2, Figure 3) withfour of the included screws (FDBD-0407CSB).
3. Attach the rear L-Bracket (MFD 93595) to the left side of the gateway (refer to 3, Figure 3) withtwo of the included screws (FDBD-0407DSC-A). Make sure that you adjust the rear bracketto that the unit fits your rack’s depth.
Figure 3. Dual Rack Mount for Left Brocade iSCSI Gateway
-
8/18/2019 Brocade ISCSI Gateway v326 HW Install
13/26
Mounting the Brocade iSCSI Gateway Dual Mounting in Rack
Brocade iSCSI Gateway Hardware Installation and Operation Guide 7Publication Number: 53-1000205-01
Attaching the Brackets to the Right Brocade iSCSI Gateway
The bracket assembly for the right gateway is shown in Figure 4.
1. Attach the left L-Bracket (MFD 93592) to the left side of the right gateway (refer to 1, Figure 4)with four of the included screws (FDBD-0407CSB).
2. Attach the right bracket (MFD 93590) to the right side of the gateway (refer to 2, Figure 4) withfour of the included screws (FDBD-0407CSB).
3. Attach the rear L-Bracket (MFD 93595) to the right side of the gateway (refer to 3, Figure 4)with two of the included screws (FDBD-0407DSC-A). Make sure that you adjust the rearbracket to that the unit fit your rack’s depth.
Figure 4. Dual Rack Mount for Right Brocade iSCSI Gateway
-
8/18/2019 Brocade ISCSI Gateway v326 HW Install
14/26
Dual Mounting in Rack Mounting the Brocade iSCSI Gateway
8 Brocade iSCSI Gateway Hardware Installation and Operation GuidePublication Number: 53-1000205-01
Joining Left Brocade iSCSI Gateway to Right Brocade iSCSI Gateway
1. Place the left gateway next to the right gateway so that the lip of the left gateway’s L-Bracket isin front of the lip of the right L-Bracket (Figure 5).
2. Attach the two by inserting two screws (FBDB-0607CSB) through the front holes of theoverlapping L-Brackets (Figure 5).
Figure 5. Attaching Left to Right Brocade iSCSI Gateway (dual mounting)
-
8/18/2019 Brocade ISCSI Gateway v326 HW Install
15/26
Mounting the Brocade iSCSI Gateway Surface Mounting the Brocade iSCSI Gateway
Brocade iSCSI Gateway Hardware Installation and Operation Guide 9Publication Number: 53-1000205-01
Attaching the dual Brocade iSCSI Gateway to the rack mounting posts
1. Insert the rear of the dual gateway unit between the rack mounting posts until the L-Bracketstouch the rack mounting posts (Figure 6).
2. Align the mounting holes on the L-Brackets with the mounting holes on the rack mountingposts (Figure 6).
3. Using screws that you provide, attach the dual gateway unit to the rack mounting poststhrough the L-Brackets and into the threaded holes in the rack mounting posts (Figure 6).
4. Make sure that the dual gateway unit is level.
Figure 6. Attaching dual Brocade iSCSI Gateway to Rack
Surface Mounting the Brocade iSCSI Gateway
The gateway can be mounted on any secure flat surface. The gateway hardware kit contains fiverubber feet for surface mounting.
Attach the rubber feet to the designated places marked on the bottom of the gateway.
-
8/18/2019 Brocade ISCSI Gateway v326 HW Install
16/26
Front Panel Brocade iSCSI Gateway
10 Brocade iSCSI Gateway Hardware Installation and Operation GuidePublication Number: 53-1000205-01
4
Brocade iSCSI Gateway
This section describes the gateway port connections and LEDs, as well as how to power up thegateway.
Front Panel
Figure 7 shows the gateway front panel.
1. RS232 console port2. Two 1 Gb copper Ethernet network port interfaces3. Two FC storage port interfaces
4.
Reset
1 0 2 0 9 b
2
iSCSI Gateway
3 41
Figure 7. Brocade iSCSI Gateway Front Panel
Back Panel
Figure 8 shows the gateway back panel.
5. Redundant Fan6. Power supply
s
1 0 2 1 4
5 6
Figure 8. Brocade iSCSI Gateway Back Panel
-
8/18/2019 Brocade ISCSI Gateway v326 HW Install
17/26
Brocade iSCSI Gateway System Indicator LEDs
Brocade iSCSI Gateway Hardware Installation and Operation Guide 11Publication Number: 53-1000205-01
System Indicator LEDs
Table 1 lists the gateway Indicator LEDs shown in Figure 9.
1 0 2 1 0 b
2 2 53 3
iSCSI Gateway
41 1
Figure 9. Brocade iSCSI Gateway LEDs
Table 1. Brocade iSCSI Gateway Indicator LEDs
No LED Status Indication Color
1 act Network port is active Greenslow blink: activefast blink: port traffic
2 1Gb Network port is operating at 1 Gb Green
3 lnk FC port is functioning at 1 or 2 Gb Green: 1 GbOrange: 2 Gb
4 Power Power is on Green
5 Sys OK All systems functioning properly Green
-
8/18/2019 Brocade ISCSI Gateway v326 HW Install
18/26
Storage Port Connection Brocade iSCSI Gateway
12 Brocade iSCSI Gateway Hardware Installation and Operation GuidePublication Number: 53-1000205-01
Storage Port Connection
Connect the SAN storage devices or FC Switch to the Brocade iSCSI Gateway using the storageports. The storage ports are located on front of the gateway. The gateway supports two FCstorage ports.
1 0 2 1 1 b
FC Storage
Ports
iSCSI Gateway
Figure 10. Brocade iSCSI Gateway Storage Ports
Note:
To connect a fiber optic cable you need a Small Form Factor Pluggable (SFP) optical transceiver tocouple to the fiber optic cable and insert into the network SFP port.
Table 2. FC Storage Port Connection Types
FC Connector Length Type
Fiber Channel 1 Gbit / 2 Gbit SFP
Short-Wave laser for multimode fiber Up to 550m SW SFP
Long-Wave laser for single-mode fiber Up to 10km LW SFP
Copper (1 Gbit) Up to 25m Copper SFP
-
8/18/2019 Brocade ISCSI Gateway v326 HW Install
19/26
Brocade iSCSI Gateway Network Port Connection
Brocade iSCSI Gateway Hardware Installation and Operation Guide 13Publication Number: 53-1000205-01
Network Port Connection
The network ports, labeled Eth1 and Eth2, are located on the front of the Brocade iSCSI Gateway(Figure 11). Each network port has a copper connector.
1 0 2 0 6 b
Copper
RJ45
Network Ports
iSCSI Gateway
Figure 11. Brocade iSCSI Gateway Network Ports
Table 3. Network Port Cable Connections
Ethernet Connector Length Type
1000BASE-TX (twisted-pair) over Category 5 UTP Up to 100m RJ45
-
8/18/2019 Brocade ISCSI Gateway v326 HW Install
20/26
Console Port Connection Brocade iSCSI Gateway
14 Brocade iSCSI Gateway Hardware Installation and Operation GuidePublication Number: 53-1000205-01
Console Port Connection
The console port is located on the front left of the gateway. Connect the console or dumbterminal with the included serial cable (male-female straight cable) to the gateway.
Figure 12. Brocade iSCSI Gateway Console Port
-
8/18/2019 Brocade ISCSI Gateway v326 HW Install
21/26
Brocade iSCSI Gateway Powering Up
Brocade iSCSI Gateway Hardware Installation and Operation Guide 15Publication Number: 53-1000205-01
Powering Up
The gateway power supply is located on the back panel.
1 0 2 1 4
5 6
Figure 13. Brocade iSCSI Gateway Power Supply
1. Plug the power cable into the gateway power supply and then into the power source.
2. Push the power switch to the ON position. The gateway powers up.
3. Make sure that:
The Power indicator LED turns green.
SYS OK LED turns green.
Each network port 1 Gb indicator LED turns green only if connected to the network andoperating at 1 Gb.
Each storage port indicator LED is green if connected to storage. With FC storage, theLED is green if connected to storage operating at 1 Gb and orange if connected to storageoperating at 2 Gb.
The fans start operating.
-
8/18/2019 Brocade ISCSI Gateway v326 HW Install
22/26
Powering Up Getting Started
16 Brocade iSCSI Gateway Hardware Installation and Operation GuidePublication Number: 53-1000205-01
5
Getting Started
This section describes the basic installation and configuration procedures, including checklists andtroubleshooting tips, for operating the Brocade iSCSI Gateway together with the Brocade iSCSIGateway Manager in a SAN environment.
Configuration of Storage Devices
Complete this pre-installation checklist of your storage devices before proceeding with theBrocade iSCSI Gateway Initial Configuration.
Table 4. Pre-installation Checklist
FC terminator A terminator is present to terminate the arbitratedloop.
RAID – multiple RAIDSETs Each RAIDSET (SLICE) is assigned a unique LUN ortarget.
RAID – multiple channel All storage targets (LUN or devices) that should bevisible to the gateway are exposed to the controllerchannel that is connected to the gateway.
Active/Passive failover All LUNs are exposed on the active controller, and the
gateway is connected to an interface belonging to it.
Active/Active failover All controllers’ interfaces expose the same storagetargets.
FC zoning The correct WWN of the gateway interface is zonedwith the storage that is designated to be used throughthe gateway.
Controller ACL Controllers are configured to allow gateway FC WWPNin the list of hosts that can access the presented LUNs.For test purposes ACL should be disabled. Use the CLI
commandf c i nt er f ace show
to list the gatewayWWPN.
-
8/18/2019 Brocade ISCSI Gateway v326 HW Install
23/26
Getting Started Brocade iSCSI Gateway Initial Configuration
Brocade iSCSI Gateway Hardware Installation and Operation Guide 17Publication Number: 53-1000205-01
Brocade iSCSI Gateway Initial Configuration
Complete the following steps to complete initial gateway configuration.
STEP 1.
Connect the storage devices
a)
Connect the storage devices to the gateway storage ports (refer to SystemIndicator LEDs, page 11).
STEP 2.
Connect the network ports
a)
Connect the GbE ports to your network or IP-SAN (refer to Network PortConnection, page 13).
STEP 3. Power up the Brocade iSCSI Gateway
a)
Follow the power up procedure described in Powering Up, page 15.
b) At power-up the gateway performs an auto-discovery and registers all attachedand powered-up storage devices.
STEP 4.
Connect and configure the management console
Do one of the following:
a) Telnet/SSH to the default IP (10.11.12.123) of the gateway.
or
b)
Use the RS232 port to connect a console or dumb terminal (refer to Console PortConnection, page 14) for initial system configuration. Use these parameters:115200-8-N-1-N, and Auto-Detect as emulation.
STEP 5.
Login to the Brocade iSCSI Gateway
a)
Press Enter on your keyboard to open the gateway Login window.b)
Enter the default user name: admin.
c)
Enter the default user password: admin.
d)
Press Enter on your keyboard.
e)
The CLI prompt > appears.
STEP 6.
Configure initial Brocade iSCSI Gateway parameters
Accept or change the default values for:
a)
IP Address.
b)
IP Mask.
c)
Brocade iSCSI Gateway name.
Note: Unless you change the default name, iSCS Gateway Manager uses the IPaddress.
d) Management port (eth1).
-
8/18/2019 Brocade ISCSI Gateway v326 HW Install
24/26
Working with Brocade iSCSI Gateway Manager Getting Started
18 Brocade iSCSI Gateway Hardware Installation and Operation GuidePublication Number: 53-1000205-01
Working with Brocade iSCSI Gateway Manager
STEP 1.
Install Brocade iSCSI Gateway Manager
a)
You must have the supported JAVA Runtime Environment (JRE) installed on themanagement station in order to install and run gateway manager. The appropriate JRE version is supplied on the CD supplied with the gateway.
b)
It is recommended to have IIS installed.
c)
Install the gateway software, by running theiS SI_Gateway_Manager_x_x_x_x_Setup exe file, located on the CD under theBrocade iSCSI Gateway folder.
STEP 2. Open Brocade iSCSI Gateway Manager client
Do one of the following:
a)
Run gateway manager client on the local machine from Start Programs Brocade
iSCSI Gateway Manager
Server Local Client
or
b) Run through a Web browser connection to the gateway manager URL:http:///iSCSI Gateway Manager/index.html.
STEP 3.
Login to Brocade iSCSI Gateway Manager
a)
Enter the default user name: admin.
b)
Enter the default password: admin.
STEP 4.
Add the Brocade iSCSI Gateway to Brocade iSCSI Gateway Manager
a)
From the gateway manager screen, right click the gateway manager icon found in
the navigation pane on the left side of the screen and select New iSCSIGateway...
b)
Enter the iSCSI Gateway Management IP Address
If you are building a cluster, select New Cluster... and add both gateways.
STEP 5.
Configure Brocade iSCSI Gateway Properties
a)
From the navigation pane, right-click the gateway icon, and select Properties. Thegateway Properties dialog box will appear, with several tabs available.
Configure IPs for iSCSI Traffic
1) Toggle to the IP tab.2) Click Add... and enter the Network Port IP address parameters.
3) Click OK.
Configure iSCSI Portals
1) Toggle to the Portals tab.2) Click Add... and enter the TCP port for each network IP address selected from
the list. The default port number is 3260.
-
8/18/2019 Brocade ISCSI Gateway v326 HW Install
25/26
Getting Started Working with Brocade iSCSI Gateway Manager
Brocade iSCSI Gateway Hardware Installation and Operation Guide 19Publication Number: 53-1000205-01
Configure IP Routing
1) If routing is needed, toggle to the IP Route tab.2) Click Add... and enter the routing values.3) A default gateway can be assigned by adding a route with the destination IP
address of 0.0.0.0 and IP Mask of 255.255.255.255.
STEP 6.
Expose Volumes
a)
From the navigation pane, select Storage.
b) Select the disk to expose from the list of available storage. Right click and selectExpose… The Expose dialog box opens.
c)
Click New Target. Enter the new target parameters, including Target Alias, TargetName, and the Default Access.
Note:
Target names must be lower-case and contain no special characters. The default forDefault Access is Read-Write ( RW . If you plan on using ACL, change the Default Access to Not Available ( NA ).
d) Assign a LUN. Additional LUNs can be added to the targets as needed.
e)
Click OK to expose the volume.
STEP 7. Volume Security optional)
a)
The Access Control List (ACL) for all targets can be set using Identities. See theBrocade iSCSI Gateway Manager GUI User Manual for details on how control andmanage the access to your iSCSI disks.
STEP 8.
Host Operations Microsoft Initiator 2.0 Example)
a) Open the Microsoft iSCSI initiator GUI on the host.
b) Toggle to Discovery tab.
c)
Click Add (Target Portals). The Add Target Portal dialog box opens.
d)
Enter the IP address of the target portal and the socket (the TCP port). Click OK.
e)
Toggle to the Targets tab to view all available targets. Select a target and click LogOn... and click OK. After Log On, the target’s status is Connected.
f)
The volumes are now available to the OS, and can be accessed and controlledthrough Computer Management.
-
8/18/2019 Brocade ISCSI Gateway v326 HW Install
26/26
Working with Brocade iSCSI Gateway Manager Getting Started
20 Brocade iSCSI Gateway Hardware Installation and Operation GuidePublication Number: 53-1000205-01