7/31/2019 GDK Adm Pro Manual1
1/24
AdminPro
General Description
Overview
Connection to GDK System
Installation
How to Program
Grid Panel
MenuFile
Edit
AdminView
Help
GDK Admin Program
Numbering Plan (PGM 01)
Slot Assignment (PGM 02)
MSN Table (PGM 03)
Flexible DID Table (PGM 05)
ISDN - System Attribute (PGM 08)
COLP Table (PGM 09)ISDN - Station Attribute (PGM 23)
ISDN - CO Attribute (PGM 37)
Emergency Service Table (PGM 06)
ICM Tenancy (PGM 16)
System Attribute 1 (PGM 40, 41, 42, 45, 46)
Exec-Sec Pairs
System Attribute 2 (PGM 50, 51, 52, 53)
Authorization Code (PGM 54)
System Attribute 3 (PGM 55, 56, 57, 58, 62, 63)
TIE Routing Table (PGM 65)
System Gain Control (PGM 66)
System Speed Zone (PGM 67)
Tone Cadency, Frequency (PGM 68, 69)
World Time Attribute (PGM 71)
World Time (PGM 72)
Voice Mail Dialing Table (PGM 73)
CO Line Name (PGM 74)
Ring Frequency (PGM 75, 76)
DCO TX Gain (PGM 77)
Digit Insert Table (PGM 78)
LCR - Day of Week (PGM 07)
LCR - Time of Day (PGM 07)
LCR - Leading Digit Table (PGM 07)
-
7/31/2019 GDK Adm Pro Manual1
2/24
-
7/31/2019 GDK Adm Pro Manual1
3/24
PC Requirement
- PC OS : Windows 95 or Windows 98
- PC Memory : Minimum 16M bytes (32 Mbytes recommended)
- PC Free Disk Space : Minimum 10Mbytes (larger than 20 M Bytes recommended)
- PC Monitor Resolution : VGA or higher
Version Compatibility
GDK AdminPro supports currently GDK '99A series. But, it will also support '98 FEB version, in nearfeature.
Connection to GDK System
The GDK ADMIN Pro has no method to connection to GDK system. So, when a user wants toup/download ADMIN database to GDK system it is necessary to use GDK ADMIN. Mediation betweenGDK ADMIN and GDK ADMIN Pro is a user file, named "USR". User file is currently using GDK ADMINand contains ADMIN database information. GDK ADMIN Pro makes or reads a user file. GDK ADMINsends a user file to GDK system and receives a user file.
-
7/31/2019 GDK Adm Pro Manual1
4/24
-
7/31/2019 GDK Adm Pro Manual1
5/24
There are two types to program GDK Admin. One is "Input Box" type, the other is "Combo Box" one.
For your understanding, refer to figure. You can see both "Input Box" and "Combo Box".
Grid Panel
Grid is combination of row and columns.
Generally, row represents order of Station, CO, BIN, and Flexible Button, etc. And, column representseach field information.
Refer to the following figures. Column represents a series of stations and row is its attributes.
-
7/31/2019 GDK Adm Pro Manual1
6/24
File
New
Open
Save
Save As
Export To Excel
Print
Print Preview
Print SetupRecent File
Exit
New
This menu is for making a new database file of GDK system. You must select a system, version, andnation.
(Currently not available)
-
7/31/2019 GDK Adm Pro Manual1
7/24
Open
This menu is for opening an existed database file to download from GDK system. Usually, its extendedname is "USR".
After selecting a file, system will analyze its system, version, and nation.
Save
This is menu for flushing some modified value in current grid control to database file.
If you don't have this menu after modifying some value, there will be no change for an user databasefile.
Save As
This menu is for saving as an another name. If there is a duplicated file, you can choice whetheroverwriting or canceling.
Export To Excel
You can export your items in grid panel to Excel 97 format file. All information in current grid panel to beviewed is exported. But, header is not exported.
Print
This menu is for printing all items in current grid panel. Also, according to size of row and column, it canautomatically determine if the way of printing is normal or landscape mode.
-
7/31/2019 GDK Adm Pro Manual1
8/24
Print Preview
This menu is for previewing a layout to be printed
(Currently not available)
Print Setup
This menu is for setup for print. It is common interface of Windows 95 or 98.
Recent File
This menu is for opening one of recent files.
(Currently not available)
Exit
This menu is for exiting this program.
Edit
Undo
Copy
Cut
Paste
Move
Undo
This menu is for undoing previous command.
(Currently not available)
Copy
This menu is for copying some value in a row or column to clip board.
(Currently not available)
Cut
This menu is for cutting some value in a row or column. According to the characteristics of program
-
7/31/2019 GDK Adm Pro Manual1
9/24
field, one is deleted and the other is set to default.
(Currently not available)
Paste
This menu is for pasting some value in a row or column from clipboard.
(Currently not available)
Move
This menu is for moving a column to another column or columns. When it is selected, you will see inputrange dialog box. Then, you input ranges (Station, CO, BIN, Hunt Group Number, Flexible Buttons, etc)
that you want, and all items in current column are moved to destinations.
Admin
This menu is dynamically created after database is opened. Configuration information determines whatAdmin menu creates.
You can program GDK Administration according to your selection in this menu.
See the figure.
-
7/31/2019 GDK Adm Pro Manual1
10/24
View
Toolbar
Status Bar
Toolbar
If this menu is checked, toolbar will be visible.
Status Bar
If this menu is checked, status bar will be visible.
Help
Help Topics
About AdminPro
Help Topics
You can see a help message using this menu.
About AdminPro
You can see information of this application.
Numbering Plan
Admin Feature is designed for change "Numbering Plan" or "Station Logical Number"."Station Port Number" is as following:
Port 0-191 (GDK186)
Port 0-135 (GDK100)
Port 0-77 (GDKFPII)
"Numbering Plans" are
Station Group Pilot Number assign
SLT Program mode select number
Internal Page Zone Numbers
Internal All Call Page Number
Meet Me Page Number
External Page Zone 1 Number
External Page Zone 2 Number (Not on FPII)
-
7/31/2019 GDK Adm Pro Manual1
11/24
External All Call Page Number
All Call Page Number
SMDR Account code Enter Number
Flash Command To CO Number
SLT Last Speed Dial
Do Not Disturb Number
Call Forward Number
Speed Dial Program Number
Message Wait Enable Number
Message Wait Return Number
Speed Dial Access Number
DND/FWD Cancel Number
Call Park Location Numbers
Alarm Reset Number
Group Call Pick up Number
Station DVU NumberNight Answer
Directed Call Pick-Up
CO Group Access [01-48:GDK186 01-24:GDK100 01-09:FPII]
CO Line Access [01-96:GDK186 01-48:GDK100 01-34:FPII)
Tie Routing Access
Retrieve Held CO Group
Retrieve Held CO Line
Access to Co Line in the 1st CO
ICM Call To Attendant Station
Print SMDR Station Base (ATD)
Print SMDR Account Group Base (ATD)
Delete SMDR Station Base (ATD)
Delete SMDR Account Group Base
Display Call Charge On LCD (ATD)
Abort Printing SMDR (ATD)
Door Phone Relay 1
Door Phone Relay 2
Door Phone Relay 3 (Not FPII)
Door Phone Relay 4 (Not FPII)
VM Message wait Enable
VM Message Wait Cancel (New topic text goes here.)
Slot Assignment
This menu consist of two part, Station and CO Slot assignment.
Maximum number of slot is as following:
GDK 186 : 17
GDK 100 : 12
GDK FPII : 8
-
7/31/2019 GDK Adm Pro Manual1
12/24
-
7/31/2019 GDK Adm Pro Manual1
13/24
Max digit in a bin no is 10
ISDN - Station Attribute
The menu supports as following:
Sub Addressing Enable (No/Yes)
Long / short configure (No/Yes)
MSN (No/Yes)
CO ATD or EXT
Progress Indicator
CO Message Wait
Station base CLIP
Station base COLP
Station base CPNStation base CLIR
ISDN - CO Attribute
The available entries are
COLP : input 2 digits
00 : Not assign
01-10: according to COLP table(PGM 09) bin no
11 : according to Extension No
DID RN : DID ignore digit No 2 digits00-99 (00 is default)
Emergency Service Table
User can input 10 bin no. Each bin no support max 5 digits.
ICM Tenancy
1. Group Attendant(STA No.)
2. Access Group No. in Sub menu
Access Group is 1-5 (GDK common) and 6-10(GDK 162).
System Attribute 1
HOLD Preference (System/Exclusive)
Auto Privacy (Yes/No)
Privacy Warning Tone (Yes/No)
Page Warning Tone (Yes/No)
-
7/31/2019 GDK Adm Pro Manual1
14/24
-
7/31/2019 GDK Adm Pro Manual1
15/24
In each entry, max 5 digit can be entered
When you input in ASCII, corresponding Numeric Data appears (ex: ABC ->"122223")
System Attribute 3
DID DIGIT CONVERSION - In this Program, User can program as following:
Receive Count : 2-4 (3: default)
Conversion : allow 0-9, "#", "*" (default"#***")
2nd Conversion: allow 0-9, (default "1234567890")
DID/DISA DESTINATION - In this Proram, User can program for incomming call
Busy_destination
Error_destination
PULSE DIAL SPEED RATIO - In this Proram, User can program
10 PPS 60/40 %10 PPS 66/33 %
20 PPS 60/40 %
20 PPS 66/33 %
MODEM ASSIGN - This attribute is for MODU
The available entries are
Modem : use MODU as "modem" or "by pass"
BAUD : MODU baud rate. for MODU 2400bps fixed.
Associate Device : Allow dumy station such as "STAxxx" (2xxx within 5 dgt)
or dedicated CO line (1xx with 3 dgt)
LCD DISPLAY MODE - The available entries are
12/24 Hour
DDMMYY/MMDDYY
SMDR Attribute I - The available entries are
SMDR SAVE
SMDR PRINT ENABLE
LONG DISTANCE/ALL CALL RECORD
PRINT INCOMING CALL
RECORD IN DETAIL
BAUD RATE : Setting GDK SMDR baud rate
available Baud are
1:300 baud
2:600 baud
3:1200 baud4:2400 baud
5:4800 baud
6:9600 baud
SMDR CURRENCY UNIT 3 characters
SMDR Attribute II - This entry is for SMDR COST Unit change
COST : 6 digits
FRACTION : 1 digit
Tie Routing Table
TIE LINE ROUTING - This is TIE Routing table (CO Number)
-
7/31/2019 GDK Adm Pro Manual1
16/24
System Gain Control
This feature can change System Gain control on "DKTU", "EKTU", "SLT", "COL", "DVU", "DTMFReceiver", "External Page", "MODU", "CPT rx level', "DCO(ISDN CO or CEPT)", "WTIB", and "R2DCO".
Input Range : 00-63
System Speed Zone
User can device external page zone into 10 zone no. The available zone range is
400-999 : GDK186
300-399 : GDK100/FPII
Note that the overlapped zone range in zone number is not allowed. The Station range means allowedto access that speed zone and the overlapped station range in zone number is not allowed. The maxstation range depent on system.
Tone Cadency, Frequency
ACNR TONE CADENCE - Ring back tone, Busy tone, Error tone and secondary dial tone can beprogrammed for ACNR.
SYSTEM TONE FREQUENCY - Frequency, user entered (dial tone, ring back tone, error tone, busytone), may change to the closest System frequency that provides.
World Time Attribute
1. Display World time or not
2. Temperature type (C/F)
3. ISD Code length : determine the length of ISD code
4. ISD code
World Time
This is world time attributes
- Nation : input within 3 digits
- Area : input within 4 digits
- Time : input time range [00-23], when restore to defalut press '00'
- Temperature : Press desired Month with flex button, and then input 3 digits within 255 for averagetemperature.
Voice Mail Dialing Table
Input digits up to 12 digits.
-
7/31/2019 GDK Adm Pro Manual1
17/24
-
7/31/2019 GDK Adm Pro Manual1
18/24
Input 4 is Zone 1 (max 6 digits).
Input 5 is Zone 2 (max 6 digits).
Input 6 is Zone 3 (max 6 digits).
LCR - Digit Modification Table
Input 1 is assigned to change Bin no (max 100)
Input 2 is A(Added Digits) up to 16 digits
Input 3 is RP(Removal Position) (01-12)
Input 4 is RN(Removal Digit No) (00-12)
Input 5 is AP (Add Position)
Input 6 is C(CO Group)
Input 7 is ALT DMT Index[0-99(with MEMU)].
Station Attribute 1
DND ( Do-Not-Disturb )
Speed Dial Access
Page Access
Call Forward Access
PLA (Preferred Line Answer)
Auto Speaker Select
Warm Line
SMDR Dial Digit Hidden DisplayCO Line Queuing
3-Minute Warning Tone
Override Priviledge
Automatic CO Hold(is Attendant?)
Data Line Security
Group Listening
Speaker-Phone/Headset
Howling Tone To SLT
Alarm/Door Bell Signaling
ICM Box Signaling
CO Individual Access
No Touch Answer
DVU Access
Voice over
Suppress Rx Data connected DM
Prepaid Call
STATION ID ASSIGN 18 consist of type and value
Keyset
DSS MAP 1 : assigned station number
DSS MAP 2 (Not on FPII) : assigned station number
DSS MAP 3 (Only on GDK186) : assigned station number
DSS MAP 4 (Only on GDK186) : assigned station number
DLS MAP 1 : assigned station number
-
7/31/2019 GDK Adm Pro Manual1
19/24
-
7/31/2019 GDK Adm Pro Manual1
20/24
Type is one of Empty, CO Line, CO Group, Loop, program feature, Speed, etc.
Value is associated one of each type.
CO Attribute 1
CO Line Group Assign
Coline COS
CO Line Group Account
DISA: for DISA input "03",
for DVU announce "02"
default is "00"
DISA Account Code
COL Name Bin No.: 00 is not assignCO/PABX
DTMF/Pulse
Universal Night Answer(UNA)
Flash type(Ground/LOOP)
Metering Type (No:0,50Hz:1,12k:2,16k:3,S-pol:4,p-pol:5)
Voice/Data For CEPT(is VOICE?)
Line Drop using CPT
Incomming call Night DVU
CO Attribute 2
FLASH TIMER - The available range is 00-30 (100msec unit)
OPEN LOOP DETECT - The available range is 00-20 (100msec unit)
CO/TIE LINE ASSIGN - The available entries are
Normal Ring
Ring/Down
Loop/Dial
Ear/Mouth Continuous
Polarity Reverse
Ear/Mouth Discontinuous
DID Line For Digital CO Line
DID LINE ASSIGN - The available entries are
Immediate Start
Wink Start
Delayed Dial Start
Note that it is not available in GDK FPII
RING(0-4)
MOH(0-4)
Dial Tone
In Signal : 0:Pulse 1:DTMF (Only GDK 186)
Out Signal: 0:Pluse 1:DTMF (Only GDK 186)
B Signal : 0:Charge 1:Free 2-9: Option (Only GDK 186)
-
7/31/2019 GDK Adm Pro Manual1
21/24
Station Ring Assign - Ring Mode
You can choose one of as following lists:
Not assign
Day
Night
Both
Station Ring Assign - Ring Count
You can choose one of 0-9
Station On Demand Ring Assign
You can choose one of 0-9 and Empty.
Hunt Group Ring Assign
You can choose one of as following lists:
Not assign
Day
Night
Both
Hunt Group On Demand Assign
You can choose one of 0-9 and Empty.
Timer 1
Exclusive Hold Recall Timer
System Hold Recall Timer
Transfer Recall Timer
I-Hold Recall Timer
ATD Recall Timer
CO Ring Detect Timer
Pause Timer
CO Release Guard TimerCO Warning Tone Timer
-
7/31/2019 GDK Adm Pro Manual1
22/24
CO Dial Delay Timer
Call Park Timer
Preset Call Forward Timer
Unsupervised Conference Timer
ACNR Retrial Pause Timer
ACNR Retrial Delay Timer
Flexible DID Time out
ACNR No Answer Timer
ACNR Retry Counter
Warm Line Timer
PBX Code Print
Prepaid Call Warning Tone Timer
DISA Retry Counter
COS on DISA seize COL
DVU Forward Answer
R2 Manage Timer(GDK186 Only)R2 Pulse Timer(GDK186 Only)
DT Delay Timer(GDK186 Only)
ACNR No Tone Retry Counter
Switch Pause Timer
Override 1st CO Group(Yes/No)
Timer2
MSG Wait Reminder Tone Time
Hook Switch Flash Timer
Hook Switch Bounce Timer
DID/DISA No Answer Timer
ICM Box Timer
Door Open Timer
Call FWD No Answer Timer
Dial Tone Timer
Inter Digit Timer
Automatic Release Timer.
Paging Timeout Timer
Ring Stop Detection Timer
Wink TimerMinimum Hook Flash Timer
SMDR Timer
DVU User Record Timer
CO Digit Analysis Counter
ACD Print Timer
Ring Phase Timer
CAMP-ON Recall Timer
Station Auto Release Timer
DCOB TYPE
DCOB Ready Timer(Only GDK186)
Erase Wakeup Ring
-
7/31/2019 GDK Adm Pro Manual1
23/24
Hunt Group Assign
In this menu user can select Station Group type and Input member. The Station Group types are
Circular
Terminal
UCD
VM
Ring
Pickup : Pickup can be any combionation with above
Max Hunt members are depend on system
64 : GDK186
32 : GDK100 /FPII
Hunt Group Attribute
If PGM 47 is already programmed, user can program this entry. This menu is divided into as following
[Circular/Terminal]
Almost the same attribute, but Pilot Hunt (Circular dedicated)
[UCD]
[VM]
[RING]
Pickup combined with any of this catacory follows above list
[PICKUP]
Canned Toll Exception Table
This entry is for Station Class 5,6 Toll check Table. This entry is divided into following
[ALLOW Table]
- 10 bin no.
- max 8 digits
[DENY Table]
- 10 bin no.
- max 8 digits
Toll Table
The Allow/Deny Tables are organized into 2 sets of tables to support 2 different toll plans at oneinstalled site. Each allow table may contain up to 20 number strings and each deny table 10 numberstrings. All bins of allow and deny tables have no entries by default. Each number string can contain upto 8 numbers including any number 0-9, *, #, "Don't care".
The following rules should be remembered when setting up the
Allow/Deny Tables:(1) If the tables have no entries, no restriction is applied.
-
7/31/2019 GDK Adm Pro Manual1
24/24
(2) If entries are made in the allow table and only there, then only those numbers are allowed.
(3) If entries are made in the deny table and only there, then only those numbers are denied.
(4) If there are entries in both tables, the allow table is searched first and if number is found, it isallowed. If not found, the deny table is searched and if number is found, it is denied If it is not found in
either table, it is allowed.