installation manual - h2oasis installation, adjustment, alteration, service or maintenance can cause...
Post on 08-Mar-2018
224 Views
Preview:
TRANSCRIPT
1 7033-328C May 09, 2017
3100 Millennium Wood Appliance
Model(s):31M-ACC-MBK
WARNING
If the information in these instruc-tions is not followed exactly, a fire could result causing property damage, personal injury, or death.
• Donotstoreorusegasolineorotherflam-mablevaporsandliquidsinthevicinityofthisoranyotherappliance.
• Donotoverfire-Ifapplianceorchimneyconnectorglows,youareoverfiring.Overfiringwillvoidyourwarranty.
• Complywithallminimumclearancestocombustiblesasspecified.Failuretocomplymaycausehousefire.
HOT SURFACES! Glassandothersurfacesarehot duringoperationANDcooldown.
Hot glass will cause burns.• Donottouchglassuntilitiscooled• NEVERallowchildrentotouchglass• Keepchildrenaway• CAREFULLYSUPERVISE children in same room as
fireplace.• Alertchildrenandadultstohazardsofhightemperatures• High temperatures may ignite clothing or other
flammable materials.• Keepclothing, furniture,draperiesandotherflammable
materialsaway.
WARNING
WARNINGFire Risk.Forusewithsolidwoodfuelonly.Otherfuelsmayoverfireandgeneratepoisonousgases(i.e.carbonmonoxide).
Installation ManualInstallation & Appliance Set-Up
INSTALLER: Leave this manual with party responsible for use and operation. OWNER: Retain this manual for future reference.
NOTICE: DO NOT DISCARD THIS MANUAL
NOTEToobtainaFrenchtranslationofthismanual,pleasecontactyourdealerorvisitwww.quadrafire.com
Pourobtenirunetraductionfrançaisedecemanuel,s’ilvousplaîtcontactervotrerevendeurouvisitezwww.quadrafire.com
O-T LTested and Listed by
PortlandOregon USA
OMNI-Test Laboratories, Inc.C US
Installation and service of this appliance should be performed by qualified personnel. Hearth & Home Technologies recommends HHT Factory Trained or NFI certified professionals.
2 7033-328C May 09, 2017
3100 Millennium Wood Appliance
1 Important Safety Information ...........3A.ApplianceCertification.............................................3B.BTU&EfficiencySpecifications..............................3C.MobileHomeApproved........................................... 3D.GlassSpecifications................................................3E.Non-CombustibleMaterials......................................3F.CombustibleMaterials..............................................3
2 Getting Started ..................................4A.DesignandInstallationConsiderations....................... 4B.FireSafety................................................................4C.NegativePressure.................................................4D.ToolsAndSuppliesNeeded....................................5E.InspectApplianceandComponents........................5F.RemovalofAppliancefromShippingMaterials.......5G.InstallChecklist........................................................6
3 Dimensions and Clearances ............7A.ApplianceDimensions.............................................7B.HearthProtectionRequirements.............................8C.ClearancestoCombustibles...................................9
4 Chimney Systems ...........................10A.LocatingYourAppliance&Chimney.......................10B.ChimneyTerminationRequirements.......................11C.2-10-3Rule..............................................................11D.ChimneyHeight/RiseandRun.................................12E.VentingComponents................................................12F.ChimneySystems.....................................................12G.InstallingChimneyComponents..............................14H.ProperDraft............................................................14
5 Appliance Set-Up ............................15A.OutsideAirKitInstallation.......................................15B.DoorHandleAssembly............................................16C.Blower(Optional)....................................................16
6 Mobile Home Installation ................177 Reference Materials ........................188 Accessory List ................................19
TABLE OF CONTENTS
Safety Alert Key:• DANGER! Indicatesahazardoussituationwhich,ifnotavoidedwillresultindeathorseriousinjury.• WARNING!Indicatesahazardoussituationwhich,ifnotavoidedmayresultindeathorseriousinjury.• CAUTION! Indicatesahazardoussituationwhich,ifnotavoided,mayresultinminorormoderateinjury.• NOTICE:Indicatespracticeswhichmaycausedamagetotheapplianceortoproperty.
Quadra-FireisaregisteredtrademarkofHearth&HomeTechnologies.
May 09, 2017 7033-328C 3
3100 Millennium Wood Appliance
Model: 3100MillenniumWoodAppliance
Laboratory: OMNITestLaboratories,Inc.Report No: 0061WS066S
Type: ListedRoomAppliance,SolidFuelType
Standard: UL1482-11(R2015)andULCS627-00and(UM)84-HUD,MobileHomeApproved.
TheQuadra-Fire3100SeriesWoodAppliance(ACC)meetstheU.S.EnvironmentalProtectionAgency’scribwoodemis-sionlimitsforwoodappliancessoldafterMay15,2015.
EPACertification#: 649EPACertifiedEmissions: 1.1gramsperhour*LHVTestedEfficiency: 79.9%**HHVTestedEfficiency: 74%
***EPABTUOutput: 11,700to32,000/hr.****PeakBTU/HourOutput: 57,200
VentSize: 6inchesFireboxSize: 2cubicfeet
RecommendedWoodLength: 16inchesFuelOrientation: Front-to-Back
Fuel SeasonedCordWood*Weighted average LHV (Low Heating Value) efficiency usingDouglasFirdimensional lumberanddatacollectedduringEPAemissiontest.LHVassumesthemoistureisalreadyinavaporstatesothereisnolossinenergytovaporize.**WeightedaverageHHV(HighHeatingValue)efficiencyusingDouglasFirdimensional lumberanddatacollectedduringEPAemissiontest.HHVincludestheenergyrequiredtovaporizethewaterinthefuel.***ArangeofBTUoutputsbasedonEPADefaultEfficiencyandtheburnratesfromthelowandhighEPAtests,usingDouglasFirdimensionallumber.****ApeakBTUoutoftheappliancecalculatedusingthemax-imumfirsthourburnratefromtheHighEPATestandtheBTUcontentofcordwood(8600)timestheefficiency.
Improper installation, adjustment, alteration, service ormaintenancecancauseinjuryorpropertydamage.Forassistanceoradditionalinformation,consultaqualifiedinstaller,serviceagencyoryourdealer.Hearth&HomeTechnologiesWILLNOTwarrantyappli-ancesthatexhibitevidenceofover-firing.Evidenceofover-firingincludes,butisnotlimitedto: • Warpedairtube • Deterioratedrefractorybrickretainers • DeterioratedbaffleandotherinteriorcomponentsD. Glass SpecificationsThisapplianceisequippedwith5mmceramicglass.Replaceglassonlywith5mmceramicglass.Pleasecon-tactyourdealerforreplacementglass.
NOTE:Hearth&HomeTechnologies,manufacturerofthisappliance,reservestherighttoalteritsproducts,theirspecificationsand/orpricewithoutnotice.
C. Mobile Home Approved • Thisapplianceisapprovedformobilehomeinstalla-
tions;whennotinstalledinasleepingroomandwhenanoutsidecombustionairinletisprovided.
• Thestructuralintegrityofthemobilehomefloor,ceil-ing,andwallsmustbemaintained.
• Theappliancemustbeproperlygroundedtotheframeofthemobilehomewith#8coppergroundwire.
• OutsideAirKit,partOAK-ACCmustbeinstalledinamobilehomeinstallation.
F. Combustible MaterialsMaterialmadeof/orsurfacedwithanyofthefollowingma-terials: -Wood -CompressedPaper -PlantFibers -Plastic -Plywood/OSB -SheetRock(drywall)
Anymaterialthatcanigniteandburn:flameproofedornot,plasteredornon-plastered.
E. Non-Combustible MaterialsMaterialwhichwillnotigniteandburn,composedofanycombinationofthefollowing:
-Steel -Plaster -Brick -Iron -Concrete -Tile -Glass -Slate
MaterialsreportedaspassingASTM E 136, Standard Test Method for Behavior of Metals, in a Vertical Tube Furnace of 750° C.
1 Important Safety InformationA. Appliance Certification
B. BTU & Efficiency Specifications
NOTE: Thisinstallationmustconformwithlocalcodes.Intheabsenceoflocalcodesyoumustcomplywith (UM) 84-HUD and NFPA211 intheU.S.A.andCAN/CSA-B365 Installation Codes in Canada.
4 7033-328C May 09, 2017
3100 Millennium Wood Appliance
Install Guide2 Getting Started
A. Design and Installation ConsiderationsConsiderationmustbegivento: • Safety • Convenience • Trafficflow • ChimneyandchimneyconnectorrequiredItisagoodideatoplanyourinstallationonpaper,usingexactmeasurements for clearancesand floor protection, beforeactuallybeginningtheinstallation.Ifyouarenotusinganexistingchimney,placetheappliancewheretherewillbeaclearpassageforafactory-builtlistedchimneythroughtheceilingandroof.Werecommendthataqualifiedbuildinginspectorandyourinsurancecompanyrepresentativereviewyourplansbeforeandafterinstallation.
Ifthisapplianceisinanareawherechildrenmaybenearitisrecommendedthatyoupurchaseadecorativebarriertogoinfrontoftheappliance. Remembertoalwayskeepchildrenawaywhile it is operatinganddonot let anyoneoperatethisapplianceunlesstheyarefamiliarwiththeseoperatinginstructions.
WARNING
• DONOTCONNECTTHISAPPLIANCETOACHIM-NEYFLUESERVICINGANOTHERAPPLIANCE.
• DONOTCONNECTTOANYAIRDISTRIBUTIONDUCTORSYSTEM.
Mayallowfluegasestoenterthehouse.
Asphyxiation Risk.
Checkbuildingcodespriortoinstallation.
• InstallationMUST complywith local, regional, state andnationalcodesandregulations.
• Consult insurance carrier, local building, fire officials orauthorities having jurisdiction about restrictions, installationinspection,andpermits.
CAUTION
NOTICE:HEARTH&HOMETECHNOLOGIESASSUMESNORESPONSIBILITYFORTHE IMPROPERPERFORMANCEOFTHEAPPLIANCESYSTEMCAUSEDBY:
• Inadequatedraftduetoenvironmentalconditions
• Downdrafts
• Tightsealingconstructionofthestructure
• Mechanicalexhaustingdevices
• Overdraftingcausedbyexcessivechimneyheights
• Idealperformance iswithheightofchimneybetween14-16feet(4.26-4.88m)measuredfromthebaseoftheappliance.
Toprovide reasonable fire safety, the following should begivenseriousconsideration:1. Install at least one smoke detector on each floor of
your home to ensure your safety. They should belocated away from the heating appliance and closeto the sleeping areas. Follow the smoke detectormanufacturer’splacementandinstallationinstructions,andbesuretomaintainregularly.
C. Negative Pressure
Negativepressure results from the imbalanceofair avail-ablefor theappliancetooperateproperly. Itcanbestron-gestinlowerlevelsofthehouse.
Causesinclude:
• Exhaustfans(kitchen,bath,etc.)• Rangehoods• Combustion air requirements for furnaces, water
appliancesandothercombustionappliances• Clothesdryers• Locationofreturn-airventstofurnaceorairconditioning• ImbalancesoftheHVACairhandlingsystem• Upperlevelairleakssuchas: - Recessedlighting - Attichatch - Ductleaks
WARNING
• Negativepressurecancausespillageofcom-bustionfumes,sootandcarbonmonoxide.
• Applianceneedstodraftproperlyforsafety.
Asphyxiation Risk.
B. Fire Safety
2. A conveniently locatedClassA fire extinguisher tocontendwithsmallfiresresultingfromburningembers.
3. ACOdetectorshouldbeinstalledintheroomwiththeappliance.
4. Apracticedevacuationplan,consistingofatleasttwoescaperoutes.
5. Aplantodealwithachimneyfireasfollows: Intheeventofachimneyfire:
a Evacuatethehouseimmediatelyb. Notifyfiredepartment.
May 09, 2017 7033-328C 5
3100 Millennium Wood Appliance
Figure 5.1
• Installationanduseofanydamagedappliance.• Modificationoftheappliance.• Installation other than as instructed byHearth &Home
Technologies.• Installationand/oruseofanycomponentpartnotapproved
byHearth&HomeTechnologies.• Operatingappliancewithoutfullyassemblingallcomponents.• Operatingappliancewithoutlegsattached(ifsuppliedwith
appliance).• DoNOTOverfire-Ifapplianceorchimneyconnectorglows,
youareoverfiring.Any such action that may cause a fire hazard.
WARNINGFire Risk.Hearth&HomeTechnologiesdisclaimsanyresponsibilityfor,andthewarrantywillbevoidedby,thefollowingactions:
D. Tools And Supplies NeededBeforebeginningtheinstallationbesurethefollowingtoolsandbuildingsuppliesareavailable:
Reciprocatingsaw Framingmaterial
Pliers Hightempcaulkingmaterial
Hammer Gloves
Phillipsscrewdriver Framingsquare
Flatbladescrewdriver Electricdrillandbits
Plumbline Safetyglasses
Level Tapemeasure
Misc.screwsandnails 7/16socketorwrench
1/2-3/4in.length,#6or#8self-drillingscrews
• Removeapplianceandcomponentsfrompackagingandinspectfordamage.
• Reporttoyourdealeranypartsdamagedinshipment.• Read all the instructions before starting the installation.
Follow these instructions carefully during the installation to ensure maximum safety and benefit.
E. Inspection of Appliance and Components
Inspectapplianceandcomponentsfordamage.Damagedpartsmayimpairsafeoperation.
WARNING
• DoNOTinstalldamagedcomponents.• DoNOTinstallincompletecomponents.• DoNOTinstallsubstitutecomponents.
Reportdamagedpartstodealer.
Fire Risk.
Tominimizetheeffectsofnegativeairpressure:• Install optional outside air kit with the intake facing
prevailingwindsduringtheheatingseason• Ensureadequateoutdoorairforallcombustionappliances
andexhaustequipment• Ensurefurnaceandairconditioningreturnventsarenot
locatedintheimmediatevicinityoftheappliance• Avoid installing theappliancenear doors,walkwaysor
smallisolatedspaces• Recessedlightingshouldbea“sealedcan”design• Attichatchesweatherstrippedorsealed• Atticmountedductworkandairhandlerjointsandseams
tapedorsealed• Basementinstallationsshouldbeavoided
1.Removeboxand2x4structuralboardsbeingcarefulnottodamageproduct.
2.Using7/16socketorwrenchremoveoneboltlocatedinsidefrontpartofappliance(Figure 5.1).
3.Movingtothebackoftheapplianceandusing7/16socketorwrenchremovetwobolts(Figure 5.1).
4.Carefullypullapplianceoffofpalletandputindesiredlocation following Hearth Pad and Clearance toCombustiblesonpages8and9.
F. Removal of Appliance from Shipping Materials
2
3
6 7033-328C May 09, 2017
3100 Millennium Wood Appliance
G. Install Checklist
Appliance Install
Appliance is leveled and connector is secured to appliance.Hearth extension size/height decided. Outside air kit installed.Floor protection requirements have been met.If appliance is connected to a masonry chimney, it should be cleaned and inspected by a professional. If installed to a factory built metal chimney, the chimney must be installed according to the manufacturer’s instructions and clearances.
Chimney
Chimney installed, locked and secured in place with proper clearance. Chimney meets recommended height requirements (14-16 feet).
Terminations installed and sealed.
ClearancesCombustible materials not installed in non-combustible areas.
Mantels and wall projections comply with installation manual requirements. Protective hearth strips and hearth extension installed per manual requirements.
Appliance SetupAll packaging and protective materials removed.
All labels have been removed from the door.All packaging materials are removed from inside/under the appliance.Manual bag and all of its contents are removed from inside/under the appliance and given to the party responsible for use and operation.
ATTENTION INSTALLER:Follow this Standard Work Checklist
This standard work checklist is to be used by the installer in conjunction with, not instead of, the instructions contained in this installation manual.
Customer: __________________________________________________________________________Date Installed: __________________________________________________________________________Lot/Address: __________________________________________________________________________Location of Appliance: ______________________________________________________________Installer: __________________________________________________________________________Dealer/ Distributor Phone #: ______________________________________________________________Serial #: __________________________________________________________________________Model : __________________________________________________________________________
WARNING! Risk of Fire or Explosion!
Hearth & Home Technologies recommends the following:
• That this checklist remain visible at all times on the appliance until the installation is complete.
Comments: Further description of the issues, who is responsible (Installer/Builder/Other Trades, etc.) and corrective action needed:Comments communicated to party responsible by on (Builder/Gen. Contractor) (Installer) (Date)
YES IF NO, WHY?
May 09, 2017 7033-328C 7
3100 Millennium Wood Appliance
24-3/8 in [618mm]
26-5/8 in [677mm]
31-3/8 in[796mm]
19-3/4 in [501mm]
Figure 7.1 Front View
Figure 7.3 Side View
25-1/4 in [641mm]
29-1/2 in[749mm]
15-1/8 in [383mm]
21 in [533mm]
11 in[278mm]
Figure 7.2 Top View
3-1/2 in[89mm]
6-11/16 in[170mm]
12-3/4 in [323mm]
3 Dimensions and ClearancesA. Appliance Dimensions NOTE:FlueCollarsizeis6inch(152mm)diameter(ID)
8 7033-328C May 09, 2017
3100 Millennium Wood Appliance
B. Hearth Protection RequirementsEMBER PROTECTION: It isnecessaryto installaTypeIfloorprotector.Floorprotectormustbenon-combustiblematerial,extendingbeneathappliancewithaminimumof16inches(406mm)infrontofglassand8inches(203mm)tobothsidesofthefuelloadingdoor.Openthedoorandmeasure8inches(203mm)fromthesideedgeoftheopeninginthefaceoftheappliance.
In Canada, It is required to install emberprotectionof 18inches(457mm)infrontand8inches(203mm)fromthesidesandrearoftheappliance.Figure 8.2 *See exception.
*EXCEPTION: Non-combustible floor protectionsmustextendbeneaththefluepipewheninstalledwithhorizontalventingandextend2inches(51mm)beyondeachside.See Figure 8.2
WARNINGFire Risk. Hearthpadsmustbeinstalledexactlyasspecified.Hightemperaturesorhotembersmayigniteconcealedcombustibles.
16 in. from glass 8 in.
Fuel loading door
.
31-5/8 in.minimum
39 in.minimum
USA
Figure 8.2Figure 8.1 Figure 8.3
203mm
203mm 203mm
457mm
1243mmminimum
1041mmminimum
Must extend 51mmbeyond each sideof pipe (shaded area)
CANADA
33-1/4 in.
38-15
/16 in
.
3-1/16
in.
135°
optio
nal
cove
rage
52-1/2 in.
31-5/
8 in
60-5/
8 in.
27-3/
8 in.
USA
Corner hearth pad dimensionswithsinglewallpipe
Corner hearth pad dimensionswithdoublewallpipe
27-3/
8 in.
31-3/4 in.
38-15
/16 in
.
3-1/16
in.
135°
optio
nal
cove
rage
51 in.
31-5/
8 in
58-1/
2 in.
USA
Figure 8.4
776m
m
806mm
1243
mm
135°
optio
nal
cove
rage
1562mm
1041
mm
1538
mm
CANADA
851mm
1243
mm
135°
optio
nal
cove
rage
1400mm
1041
mm
1592
mm
776m
m
CANADAFigure 8.5 Figure 8.6
May 09, 2017 7033-328C 9
3100 Millennium Wood Appliance
C. Clearances to CombustiblesMINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS in inches (Millimeters)
Note: A, C, and F Dimensions are to the center of the flue collar 3100 Millennium
INSTALLATION: FULL VERTICAL A B C D E F G H
SINGLE WALL PIPE 18-1/4 (464) 11-3/4 (298) 28-1/2 (724) 16 (406) 8 (203) 20 (508) 48 (1219) 12 (305)
DOUBLE WALL PIPE 13-1/2 (343) 6-1/2 (165) 25 (635) 13 (330) 6-1/2 (165) 18-1/2 (470) 48 (1219) 9 (229)
INSTALLATION: 90 DEGREE ELBOW OFF TOP OF APPLIANCE THROUGH BACKWALL
SINGLE WALL PIPE 15 (381) 8-1/2 (216) 25 (635) 13 (330) 8 (203) 20 (508) 48 (1219) 12 (305)
DOUBLE WALL PIPE 11 (279) 4-1/2 (114) 20-1/2 (521) 8-1/2 (216) 6-1/2 (165) 18-1/2 (470) 48 (1219) 9 (229)
INSTALLATION: ALCOVE
DOUBLE WALL PIPE 14-3/4 (375) 8-1/4 (210) 26-1/2 (673) 14-1/2 (368) N/A N/A 48 (1219) N/A
For alcove only: Six inch diameter listed Double wall air insulated connector pipe with UL103 HT listed factory built Class A chimney or masonry chimney. Maximum depth of Alcove shall be no more than 48 inches (1219mm) and the referenced
alcove clearances. Canada must comply with CAN/ULC-S269 M87 for the 650° factory built chimney.
NOTE: Clearances may only be reduced by means approved by the regulatory authority having jurisdiction
Fire Risk.• Complywithallminimumclearancesto
combustiblesasspecified.• Failuretocomplymaycausehousefire.
WARNINGNOTE: Service Space
Inordertoreplacethetubechannelassemblyaclearanceof19inches(483mm)isrequiredontherightsideofapplianceinordertoremovethetubeswiththeapplianceinplace.Ifspaceisnotavailable,theappliancewillhavetobediscon-nectedfromthechimneytoproceedwiththetubereplace-ment.
BACKWALL / SIDEWALL
A B
C
D
EF
F
E
CORNER INSTALLATION
C
ALCOVE TOP VIEW
G A
ALCOVE SIDE VIEW
G90° OFF TOP UP & OUT CEILING CLEARANCE
H
10 7033-328C May 09, 2017
3100 Millennium Wood Appliance
Recommended Location
Marginal Location
Location Not
Recommended
Recommended
Location
Location NOT
Recommended
Multi-level Roofs
Windward
Leeward Outside Air Kit Termination Cap
Figure 10.1
A. Locating Your Appliance & ChimneyLocation of the appliance and chimney will affect perfor-mance.AsshowninFigure 10.1thechimneyshould: • Installthroughthewarmspaceenclosedbythebuild-
ingenvelope.Thishelpstoproducemoredraft,espe-ciallyduringlightinganddiedownofthefire.
• Penetratethehighestpartoftheroof.Thisminimizestheaffectsofwindturbulenceanddowndrafts.
• Considertheappliancelocationinordertoavoidfloorandceilingatticjoistsandrafters.
• Locate termination cap away from trees, adjacentstructures,unevenrooflinesandotherobstructions.
Yourlocaldealeristheexpertinyourgeographicareaandcanusuallymakesuggestionsordiscoversolutionsthatwilleasilycorrectyourflueproblem.
4 Chimney Systems
May 09, 2017 7033-328C 11
3100 Millennium Wood Appliance
3ft.(91cm)Minimum
Lessthan10ft.(305cm)
2ft.(61cm) 3ft.(91cm)Minimum
10ft.(305cm) ToNearestRoofline2ft.(61cm)
PitchedRoofFigure 11.1
Figure 11.2
10 ft. (305cm) or more
3 ft. (91cm) Minimum
Less than 10 ft. (305cm)
2 ft. (61cm) Minimum
3 ft. (91cm) Minimum
Wall or Parapet
Flat Roof
C. 2-10-3 Rule These are safety requirements and are not meant to
assure proper flue draft.
Thisapplianceismadewitha6inch(152mm)diameterchimney connector as the flue collar on the appli-ance.
• Changingthediameterofthechimneycanaffectdraftandcausepoorperformance.
• It isnot recommended touseoffsetsandelbowsataltitudesabove4000feetabovesealevelandorwhenthereareotherfactorsthataffectfluedraft.
B. Chimney Termination RequirementsFollowmanufacturer’sinstructionsforclearance,securingflashingandterminatingthechimney.Fig. 11.1 & 11.2 • MusthaveanapprovedandListedcap
• Mustnotbelocatedwhereitwillbecomepluggedbysnoworothermaterial
• Mustterminateatleast3feet(91cm)abovetheroofandatleast2feet(61cm)aboveanyportionoftheroofwithin10feet(305cm).
• MustbelocatedawayfromtreesorotherstructuresNOTICE:• Chimneyperformancemayvary.• Trees,buildings,rooflinesandwindconditionsaffect
performance.• Chimneyheightmayneedadjustmentifsmokingor
overdraftoccurs.
NOTICE: Locating the appliance in a basement or in alocationofconsiderableairmovementcancauseintermittentsmokespillagefromappliance.Donotlocateappliancenear• Frequentlyopendoors• Central heat outlets or returns
12 7033-328C May 09, 2017
3100 Millennium Wood Appliance
NOTE: InCanadawhenusingafactory-builtchimneyitmustbesafetylisted, Type UL103 HT (2100oF) CLASS “A” or conformingtoCAN/ULC-S629M, STANDARD FOR 650oC FACTORY-BUILT CHIMNEYS.
FloorProtector
ChimneyConnector
Insulated " T "
Flashing
Listed Termination Cap
Trim Collar onInside Wall
Listed Chimney
Storm Collar
Wall Support
Roof Brace (if required)
Thimble
Figure 12.1 Prefabricated Exterior Chimney
E. Venting Components Chimney Connector:Itisalsoknownasfluepipeorappliancepipe.Thechimneyconnectorjoinstheappliancetothechimney.Itmustbea6inch(152mm)minimumdiameter24gaugemildsteelblackor26gaugebluedsteel,oranapprovedair-insulateddoublewallventingpipe.Thimble:Amanufactured or site-constructed device installed incombustiblewalls throughwhich the chimney connectorpasses to the chimney. It is intended to keep thewallsfrom igniting. Site constructed thimblesmustmeetNFPA211Standards.PrefabricatedmustbesuitableforusewithselectedchimneyandmeetUL103TypeHTStandards.Followinstructionsprovidedbythemanufacturerformanufacturedthimblesformasonrychimneyandprefabricatedchimneys.
F. Chimney Systems
Prefabricated Metal Chimney• Mustbeminimum6inch(152mm)diameter(ID)high
temperaturechimneylistedtoUL103HT(2100oF)orULCS629M.
• Mustusecomponentsrequiredbythemanufacturerforinstallation.
• Mustmaintainclearancesrequiredbythemanufacturerforinstallation.
• Refertomanufacturersinstructionsforinstallation.
D. Chimney Height / Rise and RunThisproductwasdesignedforandtestedona6inch(152mm)chimney,14to16feet(420-480cm)high,(includesapplianceheight)measuredfromthebaseoftheappliance.Thefurtheryourstackheightordiametervariesfromthisconfiguration,thegreaterthelikelihooditmayaffectperformance.Chimneyheightmayneed tobe increasedby2 -3%pereach1000feetabovesealevel.Itisnotrecommendedtouseoffsetsorelbowsataltitudesabove4000feetabovesealevelorwhenthereareotherfactorsthataffectfluedraft.
WARNINGAsphyxiation Risk.• DONOTCONNECTTHISApplianceTOACHIM-
NEYFLUESERVICINGANOTHERAPPLIANCE.• DONOTCONNECTTOANYAIRDISTRIBUTION
DUCTORSYSTEM.Mayallowfluegasestoenterthehouse.
Improperinstallation,adjustment,alteration,serviceormain-tenancecancauseinjuryorpropertydamage.Refertotheowner’sinformationmanualprovidedwiththisappliance.Forassistanceoradditionalinformationconsultaqualifiedinstaller,serviceagencyoryourdealer.
WARNING
Fire Risk.InspectionofChimney:•Chimneymustbeingoodcondition.•MeetsminimumstandardofNFPA211
• Factory-builtchimneymustbe6inch(152mm)UL103HT.
WARNING
Chimney:Thechimneycanbeneworexisting,masonryorprefabricatedandmustmeetthefollowingminimumrequirementsandasspecifiedinSection4F.
May 09, 2017 7033-328C 13
3100 Millennium Wood Appliance
FloorProtector
ChimneyConnector
Ceiling Support
Listed Chimney
Listed Termination Cap
Storm Collar
Flashing
Figure 13.1 - Prefabricated Interior Chimney
ThimbleSiteconstructedformasonrychimneyinstallation:
Components• A minimum length of 12 inches [305mm] (longer for
thicker walls) of solid insulated factory-built chimneylengthconstructedtoUL103TypeHT6inch(152mm)insidediameter.Chimneyneedstoextendaminimumof2inches(51mm)fromtheinteriorwallandaminimumof1inch(25mm)fromtheexteriorwall.
• Wall spacer, trimcollarandwallband tofit solidpackchimneyselected.
• Minimum8inch(203mm)diameterclaylinersection(ifnotalreadypresentinchimney)andrefractorymortar.
• When jurisdiction requires install approved chimneylinerinmasonrychimney.
Air Clearances•MasonrychimneyclearancemustmeetNFPA211mini-mumrequirementof2inches(51mm)tosheetmetalsup-portsandcombustibles.
•Minimumof1 inch(25mm)clearancearoundthechim-neyconnector.
•Top of wall opening is a minimum of 13-1/2 inches(343mm) from ceiling or 4-1/2 inches (114mm) belowminimum clearance specified by chimney connectormanufacturer.NFPA211minimumverticalclearanceof18inches(457mm)fromchimneyconnectorandceilingorminimumrecommendedbychimneyconnectormanu-facturer.Figure 13.2
Instructions:1. Openinsidewallatproperheightforthechimneycon-
nectortoentrythemasonrychimney. Figure 13.22. Entryholetomasonrychimneymustbelinedwithan8
inch (203mm)minimumdiameter clay liner, orequiva-lent,securedwithrefractorymortar.
3. Constructa17inchx17inch(432mmx432mm)outsidedimensionframefrom2x2framinglumbertofitintowallopening.Insideopeningofframeshouldbenolessthan14inchx14inch(356mmx356mm).Figure 13.2
4. Attachthewallspacertothechimneysideoftheframe.5. Nailtheframeintothewallopening.Thespacershould
beonthechimneyside.6. Insertthesectionofthesolidinsulatedchimneyintothe
outerwallofthemasonrychimney.7. Tightlysecurethelengthofthesolidinsulatedchimney
withthewallbandtothemasonrychimney.8. Insertasectionofchimneyconnectorintothechimney.
Makesureitdoesnotprotrudepasttheedgeoftheclaychimneylinerinsidethechimney.
9. Sealtheendofthechimneyconnectortotheclaylinerwithrefractorymortar.
10. Installtrimcollararoundthesoldpackchimneysection.
Figure 13.2
1.5”
1.0”
2.0”
2.0”1.5”
14.0” ID17.0” OD
ceiling
Minimum18.0” NFPA 211
13.5” below ceiling to top of opening
1.0”8.0”
1.5 2x2 framing stud2.0 min air clearance1.0 min air clearance4.5
or top of opening is a min.of 4.5” below min.clearance specified by connector mfg.
Center of HoleThimble
CL
CL
Wall
Include depth of hearth pad
14 7033-328C May 09, 2017
3100 Millennium Wood Appliance
Trim Collar
Chimney Section with 2 inch
(51mm) Clearance to Combustibles
Chimney Connector
Fire Clay Flue Liner
with Airspace
Masonry Chimney
Wall Band to Secure Chimney
Section
Wood Studs Used for Framing - Spaced
2 inch (51mm) clearance from
Masonry Chimney
Wall Spacer
Solid Pack Chimney with Metal Supports as a Thimble
Figure 14.1
Fire Risk.DoNOTpackinsulationorothercombustiblesbetweenspacers.• ALWAYSmaintainspecifiedclearancesaroundvent-ingandspacers.
• Installspacersasspecified.Failuretokeepinsulationorothermaterialawayfromventpipemaycausefire.
WARNING
Flue GasDirection
CrimpedEnd
TowardAppliance
Secure pipe sections with aminimum of 3 screws
Figure 14.3 Chimney Connector (Appliance Pipe)
WARNING
ONLYuseconnector:• Withintheroom,betweenapplianceandceilingorwall.ConnectorshallNOTpassthrough:• Atticorroofspace• Closetorsimilarconcealedspace• Floororceiling
Maintainminimumclearancestocombustibles
Fire Risk.FollowChimneyConnectorManufacturer’sInstructionsforProperInstallation.
Chimney FlueLiner
FireclayLiner or
Equivalent
Masonry ChimneyConstructed to NFPA 211
Wall SpacerWall Band
Trim Collar
Chimney Connector
1 inch (25mm) AirSpace to Chimney
Section
Min. Clearance2 inch (51mm)
Min. Chimney Clearance toWall Spacer and
Combustibles - 2 inch (51mm)
Chimney Section
Figure 14.2
Solid Pack Chimney with Metal Supports as a Thimble (Cont’d)
G. Installing Chimney Components
Chimney Connector
Singlewallconnectororappliancepipe.Thismustbeatleast24gaugemildsteelor26gaugebluesteel.Thesectionsmustbeattachedtotheapplianceandtoeachotherwith thecrimped(male)endpointingtowardtheappliance.Alljoints,includingtheconnectionatthefluecollar,shouldbesecuredwith3sheetmetalscrews.Makesure to follow theminimum clearances to combustibles.Wherepassagethroughthewall,orpartitionofcombustibleconstructionisdesiredinCanada,theinstallationshallcon-formtoCAN/CSA-B365.Factory-builtlistedchimneyconnector(vented).A listed connector (vented)must be usedwhen installingthisapplianceinamobilehome.Thelistedconnectorsmustconformtoeachothertoensureaproperfitandseal.
H. Proper Draft
TobesurethatyourQuadra-Fireinsertburnsproperly,thechimneydraft(staticpressure)shouldbeapproximately-0.10incheswater column (W.C.) during a high burn and -0.04inchesW.C.duringalowburn,measured6inches(152mm)abovethetopoftheinsertafteronehourofoperationateachburnsetting.
May 09, 2017 7033-328C 15
3100 Millennium Wood Appliance
Figure 15.1 - Floor & Rear Installation
Flex Line Wire Tie
Wire Tie Flex Adapter
Termination Cap
For Floor Installa-tions Remove Circular “Knock-Out” in Base of Pedestal.
Figure 15.2
CoverPlate
Rope to SealPedestal
Items Needed for Installation (not supplied) • 4inchflexaluminumpipe,orifusingalternatematerial,
thenitshallbemadefromdurable,non-combustible,heatresistantmaterialupto350oF.Cutthepipetotherequiredlengthforyourinstallation.
•Phillipsheadscrewdriver •Siliconesealant •Drillsandsawsnecessaryforcuttingholesthroughthe
wallorflooringinyourhome.1. Removeallmaterialsfrompackingbox.2. Usinga#2Phillipsscrewdriverattachtheflexadapterto
theapplianceusing4screws.Figure 15.1 3. For floor installations, remove circular” knock-out” in the
baseofthepedestal.4. Floor & Rear Installation:Cuta4inch(102mm)holein
outsidewallorfloortoaccommodateoutsideairpiping.Use4inch(102mm)aluminummetalflexorrigidpipingtodirectlyconnectoutsideairtoapplianceintake.Usethesuppliedterminationcapwitharodentscreen.Sealbetweenthewall(orfloor)andthepipewithsiliconetopreventmoisturepenetration.
5. Floor Installation Alternative: InsomeinstancesyoumaynotbeabletoinstalltheflexpipeasshowinFigure
A. Outside Air Kit Installation Asourceofair (oxygen) isnecessary inorder forcombus-tion to take place. Whatever combustion air is consumedbythefiremustbereplaced.Airisreplacedviaairleakagearoundwindowsandunderdoors.Inhomesthathavetightlysealeddoorsandwindows,anoutsideairsourceisneeded.AnoptionalOutsideAirKitisavailable. WARNING
Fire Risk.Asphyxiation Risk.Donotdrawoutsidecombustionairfrom:
• Wall,floororceilingcavity
• Enclosedspacesuchasanatticorgarage
• Closeproximitytoexhaustventsorchimneys
Fumesorodormayresult
Asphyxiation Risk.Outsideairinletmustbelocatedtopreventblockagefrom:
• Leaves
• Snoworice
• Otherdebris
Blockmaycausecombustionairstarvation
Smokespillagemaysetoffalarmsorirritatesensitiveindividuals.
WARNING
Asphyxiation Risk.LengthofoutsideairsupplyductshallNOTexceedthelengthoftheverticalheightoftheexhaustflue.• Firewillnotburnproperly• Smokespillageoccurswhendoorisopeneddue
toairstarvation.
WARNING
Included in OAK-ACC: Termination cap, (2) wire ties, flexadapter,andfasteners
Included in SRV7033-041:Cover plate and sealing rope (seeFloor InstallationAlternativebelow,Figure 15.2)
15.1.Ifthatisthecase,youwillneedtoorderSRV7033-041which includesacoverplateandsealing ropeasshowninFigure 15.2.Thegoalistosealthepedestalsonoroomaircanleakintothepedestalorforcoldairinfiltration.
5 Appliance Set-Up
16 7033-328C May 09, 2017
3100 Millennium Wood Appliance
B. Door Handle Assembly
Figure 16.1
Install spring handle using a counter-clockwisemotion until thespringhandlehasa2inchclearancefrombendofdoorhandrod(Figure 16.1).
Tools Required:#2Phillipsheadscrewdriver1.Locateboltssuppliedwiththeblower.2.Alignholesinmountingflangeofblowerwithboltholesin
appliance.BlowershouldbepositionedatbottomofrearouterskinasshowninFigure 16.2
3.Re-insert and tighten bolts, securing blower onto outerwallofappliance.
Shock Risk.• DoNOTremovegroundingprongfromplug.• Routecordawayfromappliance.• DoNOTroutecordunderorinfrontofappliance.
• Plugdirectlyintoproperlygrounded3prongreceptacle.
CAUTION
Figure 16.2
MANUAL: Over-rides the Snap Disc
AUTO: Fan will turn ON/OFF Automatically by the Snap Disc
Controls the Fan Speed
Snap Disc Bracket with Magnet
MANUAL
FAN
AUTO
LOW
HIGH OFF
Secure wires with wire tie
Secure blower with 3 bolts
4.Place the bracket containing the snap disc and magnetunderthebottomleftrearcorner.
SeeOwner’s Manualfordetailedoperatinginstructionsfortheblowerandsnapdisc.
C. Blower (Optional)
Door Handle
Spring Handle
2 inch (51mm) clearance required from bend in door handle rod to end of spring handle.
May 09, 2017 7033-328C 17
3100 Millennium Wood Appliance
CAUTIONTHESTRUCTURALINTEGRITYOFTHEMOBILEHOMEFLOOR,WALLANDCEILING/ROOFMUSTBEMAINTAINEDDoNOTcutthrough:• Floorjoist,wall,studsorceilingtrusses.• Anysupportingmaterialthatwouldaffectthestructuralinteg-
rity.
NEVERINSTALLINASLEEPINGROOM.Consumesoxygenintheroom.
WARNINGAsphyxiation Risk.
1. AnoutsideairinletmustbeprovidedforcombustionSeepage 15forinstallationinformation.
2. Appliancemustbesecuredtothemobilehomestructurebyboltingthepedestalthroughhearthpadandintofloor.
3. Appliancemust be grounded with #8 solid coppergroundingwireorequivalentandterminatedateachendwithN.E.C.approvedgroundingdevice.
4. AppliancemustbeinstalledwithanapprovedUL103HTventilated chimney connector,UL103HTchimney, andterminalcapwithsparkarrestor.Neveruseasinglewallconnector(appliancepipe)inamobilehomeinstallation.Use only double-wall connector pipe,Dura-VentDVL,Selkirk Metalbestos DS or Security DL double-wallconnectororanylisteddouble-wallconnectorpipe.
5. InCanada,thisappliancemustbeconnectedtoa6 inch(152mm) factory-built chimney conforming toCAN/ULC-629M,STANDARDFORFACTORYBUILTCHIMNEYS.
6. Followthechimneyandchimneyconnectormanufacturer’sinstructionswhen installing thefluesystemforuse inamobilehome.
7. Maintainclearancetocombustibles.8. Floorprotectionrequirementsmustbefollowedprecisely.9. Use silicone to create aneffective vapor barrier at the
locationwherethechimneyorothercomponentpenetratestotheexteriorofthestructure.
NOTE: Offsets from the vertical, not exceeding 45°, areallowedperSection905(a)oftheUniformMechanicalCode(UMC).Offsetsgreaterthan45°areconsideredhorizontalandarealsoallowed,providingthehorizontalrundoesnotexceed75%oftheverticalheightofthevent.Construction,clearanceandterminationmustbeincompliancewiththeUMCTable9C.ThisinstallationmustalsocomplywithNFPA211.NOTE:Topsectionsofchimneymustberemovabletoallowmaximumclearanceof13.5feet(411cm)fromgroundlevelfortransportationpurposes.
10. Burnwoodonly. Other types of fuelsmaygeneratepoisonousgases(e.g.,carbonmonoxide).
11. Ifapplianceburnspoorlywhileanexhaustblowerisoninhome,(i.e.,rangehood),increasecombustionair.
12. InstallationshallbeinaccordancewiththeManufacturersHome&SafetyStandard(HUD)CFR3280,Part24.
You must use a Quadra-Fire Outside Air Kit Part OAK-ACC and (depending on floor installation), Part SRV7033-041 for installation in a mobile home.
6 Mobile Home Installation
18 7033-328C May 09, 2017
3100 Millennium Wood Appliance
7 Reference MaterialsDate of Service Performed By Description of Service
May 09, 2017 7033-328C 19
3100 Millennium Wood Appliance
Service PartsR
31M-ACCBeginning Manufacturing Date: July 2006
Ending Manufacturing Date: Active
IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized dealer.
Stocked at Depot
ITEM DESCRIPTION COMMENTS PART NUMBERBlower, Convection - Replacement Blower 812-4900 YHinge Pins, 1/2”, Gold
Pre SN 0071959142832-0250
Hinge Pins, 1/2”, Nickel SRV430-5320Hinge Pins, 1/2”, Black Post SN 0071959142 7000-606/2
Logo, Quadra-FireGold 200-3180Nickel 200-3240
Spring Handle, 1/2”, GoldPre SN 0071959142
832-0620 YSpring Handle, 1/2”, Nickel 250-8330 YSpring Handle, 1/2”, Black Post SN 0071959142 SRV7000-613 YSpring Handle, 1/4”, Gold
Pre SN 0071959142832-0630 Y
Spring Handle, 1/4”, Nickel 250-8340 YSpring Handle, 1/4”, Black Post SN 0071959142 SRV7000-614 YComponent Pack (Includes Touch-Up Paint, Spring Handles (1) 1/2” and (2) 1/4”, Trimount Plug, Owners Manual and Warranty Card).
Black & Gold Trim 7033-027
Nickel Trim 7033-029Paint Touch-Up 812-0910Plug, Trimount, .250” Pkg of 24 229-0880/24 Y
Door Handle Assembly 832-0540 YUpgrade, Door, Nickel UK-DRNLGasket, Manifold Pkg of 4 7038-168/4 Y
ACCESSORIESBlower Assembly BK-ACC
Blower Control Box w/Switch SRV7000-194 YComponent Pack 7033-051Snap Disc Bracket Assembly SRV7033-036Snap Disc, # 1, Convection Blower SRV230-0470 YWire Harness, Blower 7033-262
Outside Air Kit, Floor & Rear OAK-ACCOutside Air Collar Assembly 7033-039Outside Air Shield 33271 YOutside Air Cover Plate Assembly SRV7033-041 Y
FASTENERSAvk Rivnut Repair Kit - 1/4-20 & 3/8-16 Rivnut Tools RIVNUT-REPAIR YBolt, Hex Head, 1/4-20 x 1 Pkg of 10 25221A/10 YButton Head 1/4-20 x .5 Pkg of 20 32328/20 YNut, Keps Lock, 10-32 Pkg of 40 226-0050/40 YNut, Keps Lock, 8-32 Pkg of 40 226-0060/40 YNut, Ser Flange Small 1/4-20 Pkg of 24 226-0130/24 YScrew, Sheet Metal #8 x 1/2 S-Grip Pkg of 40 12460/40 YWasher, 1/4 Sae Pkg of 24 28758/24 Y
Service PartsR
31M-ACCBeginning Manufacturing Date: July 2006
Ending Manufacturing Date: Active
IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized dealer.
Stocked at Depot
ITEM DESCRIPTION COMMENTS PART NUMBERBlower, Convection - Replacement Blower 812-4900 YHinge Pins, 1/2”, Gold
Pre SN 0071959142832-0250
Hinge Pins, 1/2”, Nickel SRV430-5320Hinge Pins, 1/2”, Black Post SN 0071959142 7000-606/2
Logo, Quadra-FireGold 200-3180Nickel 200-3240
Spring Handle, 1/2”, GoldPre SN 0071959142
832-0620 YSpring Handle, 1/2”, Nickel 250-8330 YSpring Handle, 1/2”, Black Post SN 0071959142 SRV7000-613 YSpring Handle, 1/4”, Gold
Pre SN 0071959142832-0630 Y
Spring Handle, 1/4”, Nickel 250-8340 YSpring Handle, 1/4”, Black Post SN 0071959142 SRV7000-614 YComponent Pack (Includes Touch-Up Paint, Spring Handles (1) 1/2” and (2) 1/4”, Trimount Plug, Owners Manual and Warranty Card).
Black & Gold Trim 7033-027
Nickel Trim 7033-029Paint Touch-Up 812-0910Plug, Trimount, .250” Pkg of 24 229-0880/24 Y
Door Handle Assembly 832-0540 YUpgrade, Door, Nickel UK-DRNLGasket, Manifold Pkg of 4 7038-168/4 Y
ACCESSORIESBlower Assembly BK-ACC
Blower Control Box w/Switch SRV7000-194 YComponent Pack 7033-051Snap Disc Bracket Assembly SRV7033-036Snap Disc, # 1, Convection Blower SRV230-0470 YWire Harness, Blower 7033-262
Outside Air Kit, Floor & Rear OAK-ACCOutside Air Collar Assembly 7033-039Outside Air Shield 33271 YOutside Air Cover Plate Assembly SRV7033-041 Y
FASTENERSAvk Rivnut Repair Kit - 1/4-20 & 3/8-16 Rivnut Tools RIVNUT-REPAIR YBolt, Hex Head, 1/4-20 x 1 Pkg of 10 25221A/10 YButton Head 1/4-20 x .5 Pkg of 20 32328/20 YNut, Keps Lock, 10-32 Pkg of 40 226-0050/40 YNut, Keps Lock, 8-32 Pkg of 40 226-0060/40 YNut, Ser Flange Small 1/4-20 Pkg of 24 226-0130/24 YScrew, Sheet Metal #8 x 1/2 S-Grip Pkg of 40 12460/40 YWasher, 1/4 Sae Pkg of 24 28758/24 Y
8 Accessory List
20 7033-328C May 09, 2017
CONTACT INFORMATION
Hearth & Home Technologies352 Mountain House Road
Halifax, PA 17032Division of HNI INDUSTRIES
Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer
log onto www.quadrafire.com
DO NOT DISCARD THIS MANUALCAUTION
• Important operating and maintenance instruc-tions included.
• Leave this manual with party responsible for use and operation.
• Read, understand and follow these instruc-tions for safe installa-tion and operation.
DO NOTDISCARD
We recommend that you record the following pertinent information for your heating appliance.
Date purchased/installed:_________________________________________________________________________
Serial Number:____________________________________ Location on appliance:___________________________
Dealership purchased from:________________________________________ Dealer phone:_1(_____)_____-______
Notes:________________________________________________________________________________________
______________________________________________________________________________________________
______________________________________________________________________________________________
______________________________________________________________________________________________
This product may be covered by one or more of the following patents: (United States) 5341794, 5263471, 6688302, 7216645, 7047962 or other U.S. and foreign patents pending.
top related