meru opdatering connection, marts 2013 brian andersen, systems engineer
Post on 31-Mar-2015
215 Views
Preview:
TRANSCRIPT
Meru opdateringConnection, Marts 2013
Brian Andersen, Systems Engineer
Agenda
• Forskellen på Meru og alle de andre producenter.
• Vores produkt portofølge.
• Hvilken produkter til hvilke typer af krav.
• Eksempler på nogle typiske konfigurationer.
• NSP – Support – Partner Status
• Og forhåbentlig en lang række spørgsmål undervejs.
Kort om WiFi og hvorfor Meru
Radio Physics Review
• Transmission on channels (similar to individual wires)
– Typically multiple channels available at once
• Channel is a shared medium (like a hub)
– Contention for access
– Radio is half-duplex
– Throughput is divided amongst all wireless devices
• Airtime is most precious resource
• Transmission subject to RF interference
WiFi Review – Roaming
Wired LAN (Ethernet)
Channel 1 Channel 6
Station A
BSSID=xx:xx:xx:xx BSSID=xx:zz:zz:zz:zz
Station B
WiFi Review – Roaming
• Station A is associated with AP 1 and decides to move towards AP 2.
Wired LAN (Ethernet)
Channel 1 Channel 1
Station A
VC: BSSID=xx:xx:xx:xx VC: BSSID=xx:xx:xx:xx
Station B
Channel design for service
1st kanal lag til interne brugere, 2nd kanal lag er til VoIP.3rd kanal lag er til private enheder
Meru’s produkter
Meru’s Extensive Product Portfolio
Indoor Access Points
Controllers- Appliance & VE -
Services Appliance- Appliance & VE -
Applications
MC4200500 APs5,000 clients
MC3200200 APs2,000 clients
SA200
SA2000
Scale
Service Assurance Manager
E(z)RF NMS
Spectrum
Manager
Identity ManagerGuest Management
& Smart Connect
Compliance Manager & WIP
MC60005,000 APs50,000 clients
MC155030 APs500 clients
SA250
Q3! AP8323X3:3802.11ac
AP433 & AP332 3x3:3 MIMO, 3X3:2 MIMO802.11n
AP320 3x3:2 MIMO 802.11n
OAP3803x3:2 MIMO(Outdoor)
AP10002x2:2 MIMO802.11n
AP1102x2:2 MIMO802.11n
Oct 2012
System Director 5.3 operating systemOct 2012
Service Assurance Application Suite
Simplify – How are various WLANs doing?
# of clients
Bandwidth Usage
Controller Availability
AP Availability
Mix of clients
RF Monitoring Console Displays
Spectrogram with Event Overlay
Spectrum Analyzer
Persistence
Centralized Interference and Event Log
IDM: POLICY BASED GUEST PORTALS> Dynamically generate guest portal based upon your policy using:
Location IP Address Cookies HTTP HeaderLanguage Time of Day Web Browser GET ParameterDevice OS Mobile Device POST Parameter
AUTOMATED CLIENT CONFIGURATION WITH SMARTCONNECT
1. Authenticate using web authentication
2. Download an applet to configure 802.1x
Access Point
Encrypted
Encrypted
3. Automatically connect with 802.1x
Windows iPad/iPhone Apple Mac Android
and More..
Supported Today:
Identity Manager automates the configuration through a downloadable agent from the guest portal
Meru’s Extensive Product Portfolio
Indoor Access Points
Controllers- Appliance & VE -
Services Appliance- Appliance & VE -
Applications
MC4200500 APs5,000 clients
MC3200200 APs2,000 clients
SA200
SA2000
Scale
Service Assurance Manager
E(z)RF NMS
Spectrum
Manager
Identity ManagerGuest Management
& Smart Connect
Compliance Manager & WIP
MC60005,000 APs50,000 clients
MC155030 APs500 clients
SA250
Q3! AP8323X3:3802.11ac
AP433 & AP332 3x3:3 MIMO, 3X3:2 MIMO802.11n
AP320 3x3:2 MIMO 802.11n
OAP3803x3:2 MIMO(Outdoor)
AP10002x2:2 MIMO802.11n
AP1102x2:2 MIMO802.11n
Oct 2012
System Director 5.3 operating systemOct 2012
Typisk konfiguration
MC1500Qty Product ID Description
Products
1 MC1500-XX
Wireless Controller International (NOT FOR U.S.) with support for up to 5 APs. Platform can be upgraded to support up to 30 APs. Maximum throughput of 800 Mbps, and includes System Director software (release 5.3 or higher) with Air Traffic Control, element management system, wireless security, rogue AP detection. Supports N+1 Wireless Controller Redundancy. Add -xx country code suffix for power cord: CA (Canada), JP (Japan), UK (United Kingdom), EU (Europe). US/Canada power cord will be provided if no country code.
1 MC1500-SD-10AP MC1500/MC1550 Software Upgrade License for 10 APs. Increases number of supported APs by 10 (MC1500 supports up to 30 APs). Note: Corresponding Support SKUs must be ordered for Software Upgrades and patches.
15 AP1020i Dual radio 802.11a/b/g/n access point (AP) with integrated antennas providing 180 degrees coverage. AP can be mounted horizontally and vertically. Other optional mounting brackets and screws also available.
Support
1 S3-MC1500CO 7x24x365 TAC, L1, L2 & L3 Support. Includes SW upgrades, patches & Advanced Controller HW Replacement. Duration 3 years
1 S3-MC1500-SD-10AP 7x24x365 TAC, L1, L2 & L3 Support. Includes SW upgrades and patches on System Director OS. Duration 3 years
Training
MC3200 redundant
Qty Product ID Description
Products
2 MC3200-XX
Wireless Controller International (NOT FOR U.S.) with ZERO AP licenses. Requires AP licenses to operate (part number starting with MCx000-SD). Platform can be upgraded to support up to 200 APs. Includes System Director software (5.0 or higher) with Air Traffic Control. Supports N+1 Wireless Controller Redundancy. Add -xx country code suffix for power cord: CA (Canada), JP (Japan), UK (United Kingdom), EU (Europe). US/Canada power cord will be provided if no country code.
1 MCx000-SD-100AP MC3200/MC4200/MC6000 100 AP Software Upgrade License
1 MC3200RN-1-MAX Software Module to upgrade a N+1 Slave Wireless controller for N=1 only. Note: Does NOT include hardware, software only license. For support, use base controller options.
80 AP320i Dual radio 802.11a/b/g/n access point (AP) with integrated antennas providing 180 degrees coverage. AP can be mounted horizontally (below the ceiling) and vertically (on a wall). Includes mounting bracket and screws.
Support
2 S3-MC3200CO 7x24x365 TAC, L1, L2 & L3 Support. Includes SW upgrades, patches & Advanced Controller HW Replacement. Duration 3 years.
1 S3-MCx000-SD-100AP 7x24x365 TAC, L1, L2 & L3 Software Support Only. No HW Support. Includes SW upgrades & patches. Duration 3 years
Training
MC3200 og BOYD pakke
Qty Product ID Description
Products
1 MC3200-50-XX
Wireless Controller International (NOT FOR U.S.) with 50 AP licenses. Platform can be upgraded to support up to 200 APs. Includes System Director software (5.0 or higher) with Air Traffic Control. Supports N+1 Wireless Controller Redundancy. Add -xx country code suffix for power cord: CA (Canada), JP (Japan), UK (United Kingdom), EU (Europe). US/Canada power cord will be provided if no country code.
45 AP320i Dual radio 802.11a/b/g/n access point (AP) with integrated antennas providing 180 degrees coverage. AP can be mounted horizontally (below the ceiling) and vertically (on a wall). Includes mounting bracket and screws.
1 IDM-VMW-BYOD Small Network Bundle #1 - Virtual Service Appliance for Identity Manager, Guest Management License for up to 100 concurrent users, Smart Connect software license for 500 Active Users. 1 year software technical support included.
Support
1 S3-MC3200-50-CO 7x24x365 TAC, L1, L2 & L3 Support. Includes SW upgrades, patches & Advanced Controller HW Replacement. Duration 3 years.
Training
Større sager og tilbud
• Non Standard Pricing = NSP
– Priser via disti samt Eivind Lunde
• Deal registration via partner portalen.
– Denne kommer så til Eivind
• Konfigurationer typisk via Brian
Support generelt
• Support.merunetworks.com, skal have en konto
• Mail til support@merunetworks.com og der oprettes en ticket.
• Hvis hardware fejl sender support sagen videre til RMA
• Med controller replacement aftale sendes ny controller til kunde, hvorefter kunde sender den defekte retur.Der kommer en ”tom” controller som kunde/partner skal sætte i drift......
• På AP’er er der lifetime warrenty, med sende ind service, efter RMA godkendelse i support.
802.11ac standard
Indholdet I 802.11ac Standarden
• Very High Throughput (VHT) – op til 10x sammenlignet med .11n
– Bredere kanaler: 80MHz, 160MHz, 80+80MHz (4X)
– Ny modulation: 256-QAM (1.3X)
– Flere MIMO streams: op til 8 (2X)
• Veldefineret BeamForming
• Multi-User-MIMO (MU-MIMO) – Tillader samtidge transmissioner for op til fire stationer.
Data Rater I 802.11ac
20MHz 40MHz 80MHz 160MHz
1 stream 86.7 200 433.3 866.7
2 streams 173.3 400 866.7 1733.3
3 streams 288.9 600 1300 2340
4 streams 346.7 800 1733.3 3466.7
5 streams 433.3 1000 2166.7 4333.3
6 streams 577.8 1200 2340 5200
7 streams 606.7 1400 3033.3 4095
8 streams 693.3 1600 3466.7 6933.3
Forventet I første generation af chips
Rates in Mbps
DFS
Not allowed in Europe
Bredere kanaler: 80Mhz og 160Mhz
Region DFS 40 MHz 80 MHz 160 MHz 80+80 MHz
USYes 8 4 1 2
No 4 2 - 1
EuropeYes 9 5 2 2
No 2 1 - -
Available Channels for 802.11ac
48IEEE channel #20 MHz40 MHz
80 MHz
5170MHz
5330MHz
5490MHz
5730MHz
5735MHz
5835MHz
160 MHz
36 40 44 6052 64 116
56 136
132
124
120
108
100
104
128
112
165
161
157
140
153
Weather radar
Not allowed in North America
149
144
Dynamic Frequency Selection
Beam Forming
• Sender signalet I retning af klienten. Giver øget dækning ved samme båndbredde
• Fordelen er når klienter befinder sig ved kanten af et AP’s dækning
• Specielt vigtigt for MU-MIMO
• Men men, der er begrænset effekt når AP og klient er tætte (RSSI > -60)
Meru 11ac
Klient 1
Klient 2
Standard omni-directional antenne
Design af Meru net
Configuration Topology
• Goal is to push wireless service parameters out to access points
• “Profiles” contain sets of configuration parameters
• The arrows show information flow
• Not necessarily a 1-to-1 mapping between profiles
Actually ESS-Interface Tables
Best Practice - kanal valg ,, Virtual Cell ol..
• Check at parent BSSID er ens pr. radio interface
– Via ESS-AP table
• Fra SD 5.3 kan vi på AP1000/AP332 vælge mellem 2 typer af Virtuel Cell:
– VC = shared BSSID (default setting)
– VP = privat BSSID
Check ap kommandoer m.m.
• Show ap-neighbor (4 kolonner L1,L2,L3,L4)
• Show ap-neighbor ap-id interface-id
– Show ap-neighbor 5 2 (ap-id 5 og interface 2 (5Ghz))
• Station dashboard: signal strength
• På radio diagnostics kan noice level ses
• Til sammen giver det SnR. Helst over 20. 25 ved voice
• Radio dashboard: channel utilization
• Packet loss / retry
Backup af controllere
• Show controller
• Copy running-config startup-config
• Copy running-config filnavn
• Filnavn = for eksempel dato-v-SD-version.cfg
• 091112-5096.cfg
• Copy running-config ftp://kunde-091112-5096.cfg
• Så kan vi begynde at opgradere
Opgradering af controllere
• Show controller
• Show flash (viser hvilke software image der er på controller)
• Copy ftp://bruger:pwd@ip-på-ftp/filnavn .
• Filnavn = meru-5.1-90-MC1500-rpm.tar
• Show flash
• Configure terminal -> Auto-ap-upgrade disable
• Upgrade controller 5.1-90 => reboot controller
• Upgrade ap same all
• Configure terminal -> Auto-ap-upgrade enable
Support og fejlsøgning
Support generelt
• http://support.merunetworks.com , også meget gerne på vores partner portal: http://www.merunetworks.com/partners/partners.html
•Mail til support@merunetworks.com og der oprettes en ticket.
• Hvis hardware fejl sender support sagen videre til RMA
• Med controller replacement aftale sendes ny controller til kunde, hvorefter kunde sender den defekte retur.Der kommer en ”tom” controller som kunde/partner skal sætte i drift......
• På AP’er er der lifetime warrenty, med sende ind service, efter RMA godkendelse i support.
Recommended SD Matrix
Recommended SD Matrix
Stages of Connection
What are We Trying to Do?
SwitchGateway/Firewall
NTPRADIUS
Switch
SIPDHCPDNS
SD - Station Dashboard
SD - Station Logging
1. 40
SD - Interactive Station Logging
• Used to track stations
• Needs to be enabled in 5.2 and beyond
• Station logs sent to NM without being enabled
totoro(15)# station-logInteractive Per-Station Event Logging Shell (enter "help" for help)By default logging is Disabled (enter "enable" to Enable logging)station-log> ?
Interactive Event Logging Shell Usage:
help, ? This help messageexit, quit Exit/Quit
enable Enable logging of events to consoledisable Disable logging of events to console
SD – Radio Dashboard
• Check Retry and Loss
• Check Ambient Channel Noise
• Check Association count
• Check Channel Utilization
• Check Management Overhead
SD - Filtering Packets
• The built-in ethereal sniffer lets you filter packets.
• Syntax:
– -R primitive[[equivalence value]
– No spaces are allowed in filter specification
– Equivalences are: == (equal to), != (not equal to)
• Capture only SIP packets:
– name# capture-packets -R sip
• Capture traffic from an IP address:
– name# capture-packets -R ip.addr==192.168.10.50
• For more complex filtering, capture files to laptop and use Wireshark
top related