nexiva insertion guide - bd · bd nexiva™ closed iv catheter system bd nexiva™ closed iv...
Post on 12-Jul-2020
11 Views
Preview:
TRANSCRIPT
BD NEXIVA™ Closed IV Catheter System
BD Nexiva™
Closed IV Catheter System
BD NEXIVA™ Closed IV Catheter System BD NEXIVA™ Closed IV Catheter System
Secure Connections • Vent plug
- Must remain in place during insertion for • Flashback and
• Blood containment
• BD Q-Syte™ luer access split-septum
BD Q-Syte™
DeviceVent Plug
Air
BD NEXIVA™ Closed IV Catheter System BD NEXIVA™ Closed IV Catheter System
Release Seal • Loosens catheter for
easier advancement
• Pull back ~ 1/8 inch
BD NEXIVA™ Closed IV Catheter System BD NEXIVA™ Closed IV Catheter System
Colour to WhiteEverything Tight
• Push coloured platform
and white grip back
together
BD NEXIVA™ Closed IV Catheter System BD NEXIVA™ Closed IV Catheter System
Keep it Sharp
X
BD NEXIVA™ Closed IV Catheter System BD NEXIVA™ Closed IV Catheter System
BD Instafl ash™ Needle Technology
• Immediate blood
return is seen within
the catheter
Initial Blood Return
BD NEXIVA™ Closed IV Catheter System BD NEXIVA™ Closed IV Catheter System
Lower and Advance
• Lower catheter almost parallel to skin
• Slightly advance entire unit to ensure catheter tip is within vessel
BD NEXIVA™ Closed IV Catheter System BD NEXIVA™ Closed IV Catheter System
Forward First
X
Pad to tab
Forward fi rst
Don’t pull back
Not fi ngernail
BD NEXIVA™ Closed IV Catheter System BD NEXIVA™ Closed IV Catheter System
Forward First
X
BD NEXIVA™ Closed IV Catheter System BD NEXIVA™ Closed IV Catheter System
Secondary Flash
• Blood return continues up the extension
• Continuous fl ow confi rms the catheter tip is within the vessel lumen
• Quickens as needle is withdrawn
Blood Return
BD NEXIVA™ Closed IV Catheter System BD NEXIVA™ Closed IV Catheter System
Stabilize & Remove
BD NEXIVA™ Closed IV Catheter System BD NEXIVA™ Closed IV Catheter System
Stabilize Site
• Transparent dressing should cover the septum
Septum
BD NEXIVA™ Closed IV Catheter System BD NEXIVA™ Closed IV Catheter System
Clamp & Replace Vent Plug
• Clamp extension - Prevents blood leakage
• Replace vent plug with BD Q-Syte™ device; fl ush this same port
1
2
BD NEXIVA™ Closed IV Catheter System BD NEXIVA™ Closed IV Catheter System
Unclamp & Flush • Unclamp
• Flush • CLAMP BEFORE DISCONNECT - Helps prevent blood
refl ux into catheter tip
• Keep clamped when not in use • Single lumen catheter - Compatible meds only
BD NEXIVA™ Closed IV Catheter System BD NEXIVA™ Closed IV Catheter System
BD Medical 2771 Bristol CircleOakville, OntarioL6H 6R5www.bd.com/ca