ACTERNA E1 SERVICE TESTER EST-120

Setup Ber Tester for VODAFONE ro.\CD - Manualul echipei contractorului Vers 4.2\Manualul - Echipei contractorului\Anexa - d - Interconectarea echipamentelor ISS\Procedura test BER pe link-ul de acces.ppt

1. GSM/UMTS - 24 h(86400s)2. ISS/Data – 1 h (3600s)

Menu 1 Current test : 1- 8

Mode - RX/TX V.11 slot - OFFInterface - G.703 Rx slots - 1Line Code - HDB 3 Rx audio - OFFFraming - PCM31C Tx slots – 1

Termination – 75/120Ω Tx Clk src - Intern

Menu 2

Idle pattern - 0101 0101 Bits/Block - OFF Bert pattern - 0101 0101 Rx logic - Norm Tx logic - Norm

Menu 3

Timer - OFF Resolution – HRS/MINS Autoprint – OFF Beeper - ON G.821 – OFF Alarms - User Multiframe – ITU-T

RUN

Rx/Tx G.703,PCM31C Rx 0-15 16-31 Total seconds 3600 / 86400 Line rate 2048000 Bit err ratio 0.000E 0