DESCRIPTION

SUMARE PAYLOAD. CONTENTS Objectives. Sensors choice. Sensors performances. Implant possibilities. Sensors conditioning. Schedule. Sensors integration drawings. Fins navigation trials. Fresh water tank measurement sensors. 2. OBJECTIVES - PowerPoint PPT Presentation

TRANSCRIPT

RESERVE SOCIETE

SUMARE PAYLOAD

TMS SAS 00/S/EDA/NC/088 - MP

RESERVE SOCIETE

CONTENTS

• Objectives.• Sensors choice.• Sensors performances.• Implant possibilities.• Sensors conditioning.• Schedule.• Sensors integration drawings.• Fins navigation trials.• Fresh water tank measurement sensors.

2

TMS SAS 00/S/EDA/NC/088 - MP

RESERVE SOCIETE

OBJECTIVES

The “Payload” will assume two main operational functions.

• Monitoring of the volumetric evolution of sand banks.• Obstacles avoidance.

3

TMS SAS 00/S/EDA/NC/088 - MP

RESERVE SOCIETE

SENSORS CHOICE

Altimeter.

Acoustic high frequency transducer ( Resolution)

Obstacles avoidance.

The inner Mauve transducer is not available (Software limits / Discrimination).

The transducer is the same than for altimeter.

4

TMS SAS 00/S/EDA/NC/088 - MP

RESERVE SOCIETE

5

TMS SAS 00/S/EDA/NC/088 - MP

SENSORS PERFORMANCES

Measurement limit : 50 mMeasurement mode : Free runMeasurement speed : 10 HzPower supply : 12 or 24 VDCInterface : RS 232 or RS 485Frequency : 500 kHzConical beam : 6°

RESERVE SOCIETE

TMS SAS 00/S/EDA/NC/088 - MP

IMPLANT POSSIBILITIES

1 : Risk on Payload structure (depth)Obstacle avoidance sensor not possible.

2 : Risk on launching.

3 : chosen solution

6

1

2

3

RESERVE SOCIETE

SENSORS CONDITIONING

Conditioning electronic : two output

Two output are available on MMNS

1 RS 2321 RS 485

The two electronic signal conditioning units will be connected on these outputs

7

TMS SAS 00/S/EDA/NC/088 - MP

RESERVE SOCIETE

SCHEDULE

8

TMS SAS 00/S/EDA/NC/088 - MP

2000 20015 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12

fins dummy productionVillefranche Fins dummy navigation sea trials Measurement system specificationPayload implant proposalfins prototype productionVillefranche Fins prototype navigation sea trials Software / Payload validatePayload productionFresh water tank Payload measurementVillefranche sea trials

RESERVE SOCIETE

SENSORS INTEGRATION.

4 configurations will be tested at sea.

• 1 :Fins 60 mm long in front of the payload.• 2 :Fins 60 mm long in back of the payload.• 3 :Fins 120 mm long in front of the payload.• 4 :Fins 120 mm long in back of the payload.

9

TMS SAS 00/S/EDA/NC/088 - MP

RESERVE SOCIETE

1 :Fins 60 mm long in front of the payload.10

TMS SAS 00/S/EDA/NC/088 - MP

FRONT VIEWSIDE VIEW

TOP VIEW

RESERVE SOCIETE

1 :Fins 60 mm long in back of the payload.11

TMS SAS 00/S/EDA/NC/088 - MP

FRONT VIEWSIDE VIEW

TOP VIEW

RESERVE SOCIETE

3 :Fins 120 mm long in front of the payload.12

TMS SAS 00/S/EDA/NC/088 - MP

FRONT VIEWSIDE VIEW

TOP VIEW

RESERVE SOCIETE

4 :Fins 120 mm long in back of the payload.13

TMS SAS 00/S/EDA/NC/088 - MP

FRONT VIEWSIDE VIEW

TOP VIEW

RESERVE SOCIETE

fins with their moulds14

TMS SAS 00/S/EDA/NC/088 - MP

RESERVE SOCIETE

FRESH WATER TANK MEASUREMENT SENSORS

15

TMS SAS 00/S/EDA/NC/088 - MP

Computer

Signal generatorPower amplifier

Amplifier

Oscilloscope

Rotating unit

Reference hydrophone

top related