A
N
I
L
O
V
I
A
L
E
X
T
E
R
N
O
-
U
N
I
V
E
R
S
I
D
A
D
N
A
C
I
O
N
A
L
SALA DE PROYECCION
BODEGA / DEPOSITO
AREA: 24m
CUARTOS TECNICOS
AREA: 25m
CUARTO DE BOMBAS
SALIDA DE EMERGENCIA /
EVACUACION
ASCENSORES
HALL DE ACCESO
AREA: 80m²
BATERÍAS DE BAÑOS Y SERVICIOS
SALIDA DE EMERGENCIA /
EVACUACION
BODEGA / DEPOSITO
T
R
A
M
O
1
P
E
N
D
I
E
N
T
E
1
2
%
TR
AM
O 2
PE
ND
IE
NT
E 1
2%
T
R
A
M
O
3
P
E
N
D
IE
N
T
E
1
2
%
T
R
A
M
O
1
P
E
N
D
I
E
N
T
E
1
2
%
T
R
A
M
O
2
P
E
N
D
I
E
N
T
E
1
2
%
T
R
A
M
O
3
P
E
N
D
I
E
N
T
E
1
2
%
P
E
N
D
IE
N
T
E
1
0
%
P
E
N
D
I
E
N
T
E
1
0
%
CUARTO
PLANTA ELÉCTRICA
ASEO
TANQUE DE AGUA LLUVIA
DESARENADA
TANQUE DE INCENDIO Y
ALL TRATADA
44 M3
TANQUE AGUA POTABLE
22 M3
PISO -1
NF. -2.63
PISO -1NE. -2.70
BOMBASNE. -4.10
PISO 1
NF. 0.00
PISO -1
NF. -0.97
PISO -1
NF. -1.83
PISO -1
NF. -1.76
PISO -1
NF. -1.13
PISO 1
NF. 0.00
PISO -1
NF. -3.83
PISO -1
NF. -3.83
PISO -1
NF. -2.63
PISO -1
NF. -2.63
PISO -1
NF. -2.63
PISO -1NE. -3.90
PISO -1NE. -3.36
PISO -1NE. -2.70
PISO -1NE. -3.90
PISO -1NE. -3.36
PISO -1NE. -3.90
PISO -1NE. -2.70
PISO -1NE. -3.90
PISO -1NE. -2.70
SOTANO
NF. -2.70
ON
OFF A1B1
A2
B2 A0
B0
U V W
y Pn
z xU V W
UA
VA
WA
UB
VB
WB
ELECTRODO DE P.T.
5/8"X2.44MTS
Cable de Cu
2/0 AWG desnudo
2Ø4"PVC
Malla eslabonada galvanizada
con separacion de eslabones de 2"
Varillas
Ø ½"
Alambre de puas galvanizado
soldado al tubo (cinco)
Tubo Galvanizado Ø2"
Centro de Transformacion de
Pedestal según Norma CTS 531
Foso de Aceite
ELECTRODO DE P.T.
5/8"X2.44MTS
CS 276
CAJA DE INSPECCION SPT
30X30X30
ELECTRODO 5/8"X2.40MTS
4Ø6" PVC
3X70mm² XLPE Al
ELECTRODO DE P.T.
5/8"X2.44MTS
6.0
0
6.0
0
CAJA DE INSPECCION SPT
30X30X30
ELECTRODO 5/8"X2.40MTS
CAJA DE INSPECCION SPT
30X30X30
ELECTRODO 5/8"X2.40MTS
Cable de Cu
2/0 AWG desnudo
ELECTRODO DE P.T.
5/8"X2.44MTS
Malla para Puesta
a Tierra según Norma CTS 523-2
2Ø4"PVC
3X2Cu15kv
ELECTRODO DE P.T.
5/8"X2.44MTS
ELECTRODO DE P.T.
5/8"X2.44MTS
Foso de Aceite
CS 276
.40
.15
Cable de Cu
2/0 AWG desnudo
CAJA DE INSPECCION SPT
30X30X30
ELECTRODO 5/8"X2.40MTS
CAJA DE INSPECCION SPT
30X30X30
ELECTRODO 5/8"X2.40MTS
CAJA DE INSPECCION SPT
30X30X30
ELECTRODO 5/8"X2.40MTS
4(3#350+1#350+1#4/0T) Cu
6Ø4"PVC
Centro de Transformacion de
Pedestal según Norma CTS 531
Malla eslabonada galvanizada
con separacion de eslabones de 2"
Puerta en Celosia
ICTAACCESO PEATONAL
CALLE 26ENTRADA PEATONAL
Cll. 45ACCESO PEATONAL
Y PEAT. TRANSV.38A
CA
RR
ER
A 3
0
CALLE 53
ACCESO VEHIC. Y
AVENIDA "EL DORADO"
701
TRANSVERSAL
38A
OFICINA DE PLANEACION
INSTITUCIONAL
Y DEL TERRITORIO
UNIVERSIDADNACIONAL
DE COLOMBIA
564-AULAS CIENCIAS
OBSERVACIONES:
N
VICERRECTORIA DE SEDE
SEDE BOGOTA
PLANCHA No.:
PLANO No.:
REVISION:
DE:
CONTIENE:
FECHA:ESCALA:
ARCHIVO: FECHA REVISION:
ELABORACION:DIBUJO:
PROYECTO:
LOCALIZACION:
REVISIONES:
1
0 1 2 5 10m
2 3 4 5 6 7 8
D
B
A
1 2 3 4 5 6 7 8
D
C
B
A
C
B
DIRECTORA OFICINA DE PLANEACION
INSTITUCIONAL Y DEL TERRRITORIO:
ARQ. GUILLERMO FISCHER
VICERRECTOR GENERAL:
DR. JORGE IVÁN BULA ESCOBAR
RECTOR UNIVERSIDAD NACIONAL:
DR. IGNACIO MANTILLA
VICERRECTOR DE SEDE - BOGOTA:
Ing. DIEGO HERNANDEZ LOZADA
DECANO FACUTAD DE CIENCIAS
DR. JESÚS SIGIFREDO VALENCIA
Mat. Profesional No:
CONVENCIONES:
MAT.25205-14197 C/MARCA
VALIDA :
ING. OSCAR RODRIGUEZ Q.
MAT.CN 205 -102403
ING. RONALD SUSA SUTACHAN
MAT. 25348 - 231465 CND
ING. NELSON RODRIGUEZ
REVISA:
DISEÑA:
MAT.CN 205 -109124
ING. VIVIANA ESTUPIÑAN PINILLA
MODIFICA :
2
AE-001
S.BOTERO
UN ACOMETIDAS.dwg
1:125
ACOMETIDAS ELECTRICAS
1
5
PLANTA SUBTERRANEO
EMISION INICIAL19-12-2012REV.0
17-02-2016
01-02-2017
04-03-2017
REVISION CLIENTE17-02-2016REV.1
APROBADO PARA CONSTRUCCION20-03-2016REV.2
REV.301-02-2017
ACTUALIZACION ARQUITECTONICA
AutoCAD SHX Text
SUBE A T-2 Y T-REG2
AutoCAD SHX Text
EN PISO 2
AutoCAD SHX Text
C.P.50X50X20Cms
AutoCAD SHX Text
C.P.60X60X30Cms
AutoCAD SHX Text
TRANSFERENCIA
AutoCAD SHX Text
3#6+1#6+1#8T Cu
AutoCAD SHX Text
1%%C1½" PVC
AutoCAD SHX Text
SUBE A CUBIERTA
AutoCAD SHX Text
TRANSFERENCIA
AutoCAD SHX Text
T-BOMBAS
AutoCAD SHX Text
PUNTO DE CONEXION
AutoCAD SHX Text
DESDE PLANTA
AutoCAD SHX Text
EMERGENCIA T-INC.
AutoCAD SHX Text
3#1/0+1#2T Cu
AutoCAD SHX Text
1%%C3" PVC
AutoCAD SHX Text
SUBE Y VA TRANSFORMADOR T-INC.
AutoCAD SHX Text
+3#6+1#4+1#8T Cu
AutoCAD SHX Text
2%%C3"+1%%C1½" EMT
AutoCAD SHX Text
2(3#1/0+1#1/0+1#2T) Cu
AutoCAD SHX Text
T-2 Y T-REG.2
AutoCAD SHX Text
3#1/0+1#1/0+1#2T Cu
AutoCAD SHX Text
1%%C3" EMT
AutoCAD SHX Text
SUBE Y VA TRANSFORMADOR
AutoCAD SHX Text
4(3#350+1#350+1#4/0T) Cu
AutoCAD SHX Text
6%%C4"PVC
AutoCAD SHX Text
VA A PUNTO DE CONEXION
AutoCAD SHX Text
PLANTA DE EMERGENCIA
AutoCAD SHX Text
3#6+1#6+1#8T Cu
AutoCAD SHX Text
1%%C1½" EMT
AutoCAD SHX Text
4(3#500+1#500+1#350T)Al
AutoCAD SHX Text
4%%C4"PVC
AutoCAD SHX Text
2(3#1/0+1#1/0+1#2T) Cu
AutoCAD SHX Text
2%%C3" PVC
AutoCAD SHX Text
3#1/0+1#1/0+1#2T Cu
AutoCAD SHX Text
3#1/0+1#1/0+1#2T Cu
AutoCAD SHX Text
3#1/0+1#1/0+1#2T Cu
AutoCAD SHX Text
3#1/0+1#1/0+1#2T Cu
AutoCAD SHX Text
3#1/0+1#2T Cu
AutoCAD SHX Text
1%%C3" PVC
AutoCAD SHX Text
+2(2#8+1#8T) Cu
AutoCAD SHX Text
2%%C1¼"+2%%C1" EMT
AutoCAD SHX Text
2(3#8+1#8+1#10T) Cu
AutoCAD SHX Text
3#1/0+1#2T Cu
AutoCAD SHX Text
1%%C3" PVC
AutoCAD SHX Text
PLANTA DE
AutoCAD SHX Text
EMERGENCIA
AutoCAD SHX Text
3#6+1#4+1#8T Cu
AutoCAD SHX Text
1%%C1½" EMT
AutoCAD SHX Text
BANDEJA TIPO MALLA
AutoCAD SHX Text
54X100 mm
AutoCAD SHX Text
BANDEJA TIPO MALLA
AutoCAD SHX Text
54X100 mm
AutoCAD SHX Text
PROYECCION REJILLAS VENTILACION
AutoCAD SHX Text
DUCTOS/REJILLAS VENTILACION, VER A312
AutoCAD SHX Text
DUCTOS/REJILLAS VENTILACION, VER A312
AutoCAD SHX Text
REJILLA VENTILACION A SUPERFICIE, VER PLANO A312
AutoCAD SHX Text
BANDEJA TIPO MALLA
AutoCAD SHX Text
54X300 mm
AutoCAD SHX Text
BANDEJA TIPO MALLA
AutoCAD SHX Text
54X100 mm
AutoCAD SHX Text
BANDEJA TIPO MALLA
AutoCAD SHX Text
54X100 mm
AutoCAD SHX Text
CORTE A-A'
AutoCAD SHX Text
ESCALA 1:50
AutoCAD SHX Text
CORTE B-B'
AutoCAD SHX Text
LIBERTAD
AutoCAD SHX Text
SALIDA PARA TOMA MONOFASICA DOBLE
AutoCAD SHX Text
SALIDA PARA TOMA REGULADA CON TIERRA AISLADA
AutoCAD SHX Text
TUBERIA POR TECHOS Y MUROS
AutoCAD SHX Text
TUBERIA POR PISOS
AutoCAD SHX Text
TABLERO DE CIRCUITOS
AutoCAD SHX Text
SALIDA PARA TOMA PATATRABADA
AutoCAD SHX Text
- LAS SALIDAS DE ALUMBRADO FLUORESCENTE TERMINAN EN UNA CAJA DE SALIDA CON TOMA
AutoCAD SHX Text
CORRIENTE MONOFASICO DE LA CUAL SE CONECTA UN CABLE ENCAUCHETADO DE 3X14 AWG LSHF QUE
AutoCAD SHX Text
BAJA A LA LÁMPARA CON SU RESPECTIVO ENCHUFE, CONSERVANDO UNA LONGITUD QUE NO GENERE
AutoCAD SHX Text
ESFUERZOS MECÁNICOS.
AutoCAD SHX Text
- DEBE IR A LO LARGO DE TODA LA INSTALACION ELECTRICA UN CONDUCTOR DESNUDO #12 AWG PARA
AutoCAD SHX Text
LA CONTINUIDAD DE TODOS LOS CIRCUITOS ELÉCTRICOS
AutoCAD SHX Text
OHMIOS ASI COMO GARANTIZAR QUE LA TENSION ENTRE EL NEUTRO Y LA TIERRA SEA MENOR QUE 1
AutoCAD SHX Text
- SE DEBE MEDIR Y VERIFICAR LA RESISTENCIA DE PUESTA A TIERRA LA CUAL DEBE SER MENOR A 10
AutoCAD SHX Text
- LOS TRABAJOS DEBEN EJECUTARSE DE ACUERDO CON LAS NORMAS DE CONSTRUCCION DEL OR, LA
AutoCAD SHX Text
NORMA NTC 2050 Y RETIE SIENDO EJECUTADAS POR UN INGENÍERO O FIRMA DE INGENIEROS
AutoCAD SHX Text
- LAS CÁMARAS CS-274, 275 Y 276 LLEVAN DESAGUE EL CUAL SE CONECTARÁ A LA RED GENERAL
AutoCAD SHX Text
- LOS MATERIALES UTLIZADOS EN EL PROYECTO DEBEN CUMPLIR CON LAS ESPECIFICACIONES EXIGIDAS
AutoCAD SHX Text
POR EL REGLAMENTO TÉCNICO DE INSTALACIONES ELÉCTRICAS "RETIE".
AutoCAD SHX Text
TELEFONOS, SISTEMAS Y ALARMAS DEBEN SER METALICAS DEL TIPO EMT PARA USO INTERIOR EN
AutoCAD SHX Text
UNA DISPOSICION EXPUESTA Y POR MUROS FALSOS HECHOS EN DRYWALL Y PVC PARA
AutoCAD SHX Text
A SER CONSTRUIDAS, POR TANTO PARA SU EJECUCIÓN SE DEBE TENER EN CUENTA EL SISTEMA
AutoCAD SHX Text
- LA TUBERIA A EMPLEAR PARA LAS INSTALACIONES ELECTRICAS INTERIORES DE: POTENCIA,
AutoCAD SHX Text
CONSTRUCTIVO, ESTRUCTURAL Y ARQUITECTONICO SE PODRAN HACER AJUSTES Y DERIVACIONES
AutoCAD SHX Text
MENORES SIEMPRE Y CUANDO SE TENGA Vo.Bo. DE LA INTERVENTORIA O DIRECCION DEL PROYECTO.
AutoCAD SHX Text
- LOS PLANOS MUESTRAN ESQUEMATICAMENTE LAS INSTALACIONES ELECTRICAS Y DE COMUNICACION
AutoCAD SHX Text
- TODO CONDUCTOR SERA EN COBRE CALIBRE No.12 AWG LSHF EXCEPTO DONDE SE INDIQUE LO
AutoCAD SHX Text
- TODA LA TUBERIA ELECTRICA SERA DE DIAMETRO %%C1/2" EXCEPTO DONDE SE INDIQUE LO CONTRARIO.
AutoCAD SHX Text
- TODOS LOS TOMACORRIENTES DEBEN ESTAR A 30CM DEL PISO TERMINADO A MENOS QUE ESTE
AutoCAD SHX Text
- SIN IMPORTAR QUE LA TUBERÍA ELÉCTRICA SEA METÁLICA, TODOS LOS CIRCUITOS DEBEN LLEVAR
AutoCAD SHX Text
CONDUCTOR DE CONTINUIDAD A TIERRA.
AutoCAD SHX Text
- TODO CONDUCTOR DEBERÁ DIFERENCIARSE EN SU CHAQUETA AISLANTE CUMPLIENDO CON EL CODIGO
AutoCAD SHX Text
DE COLORES PARA CONDUCTORES DE LA TABLA 13 DEL RETIE.
AutoCAD SHX Text
- TODOS LOS CIRCUITOS MONOFÁSICOS PARA RED NORMAL DEBEN DE TENER UN CONDUCTOR DE
AutoCAD SHX Text
NEUTRO INDEPENDIENTE DESDE EL TABLERO, ES DECIR QUE NO SE ACEPTA UN NEUTRO COMÚN PARA
AutoCAD SHX Text
- TODOS LOS INTERRUPTORES DEBEN ESTAR A 90CM DEL PISO TERMINADO.
AutoCAD SHX Text
DOS O TRES CIRCUITOS
AutoCAD SHX Text
- TODA LA TUBERIA DE COMUNICACIONES SERA DE DIAMETRO %%C1" EXCEPTO DONDE SE INDIQUE LO
AutoCAD SHX Text
CONTRARIO.
AutoCAD SHX Text
- TODOS LOS TOMACORRIENTES O SALIDAS ELÉCTRICAS EN LA ZONA DE COCINA DEBEN ESTAR
AutoCAD SHX Text
SEPARADOS COMO MÍNIMO A 0.35 m DE LAS SALIDAS DE GAS.
AutoCAD SHX Text
- TODAS LAS SALIDAS DE TELEFONOS Y TV DEBEN ESTAR A 30CM DEL PISO TERMINADO A MENOS QUE
AutoCAD SHX Text
ESTE ACOTADO.
AutoCAD SHX Text
SUBTERRANEAS, EN MUROS, MAMPOSTERIA Y EMBEBIDAS EN LOZA.
AutoCAD SHX Text
DE DESAGUES.
AutoCAD SHX Text
CONTRARIO.
AutoCAD SHX Text
ACOTADO.
AutoCAD SHX Text
ELECTRICISTAS
AutoCAD SHX Text
SALIDA PARA FLUXOMETRO