building technologies sipass networked. siemens building technologies fire & security products...
TRANSCRIPT
Building Technologies
Building Technologies
SiPass networked
Siemens Building Technologies Fire & Security Products GmbH & Co. oHG
SiPass networked 2 Building TechnologiesBuilding TechnologiesJune 2005
Overview SiPass™ Product Family
SiPass standalone SiPass integrated
The SiPass range of products are all compatible. You can install one system and then when your business grows expand the access system without the need to rewire or reinstall existing components.
SiPass networked
Siemens Building Technologies Fire & Security Products GmbH & Co. oHG
SiPass networked 3 Building TechnologiesBuilding TechnologiesJune 2005
SiPass networked
Product Description• Easy to install access control for 1 to
16 doors
Main Features• 7 clicks to install software
• Plug & Play hardware installation
• Intuitive software for easy operation
• Compatible with Windows NT4, 2000, XP
• Connection of up to 8 Dual Reader Controllers (16 doors)
• Up to 500 card holders
• Remote programming including automatic firmware upgrades
• Up to 12 programmable time schedules
• Up to 19 programmable holidays
• Starter-Kits & Extension-Kits
• Battery backup capability
• Languages: DE, EN, FR, ES, NL, PL
Siemens Building Technologies Fire & Security Products GmbH & Co. oHG
SiPass networked 4 Building TechnologiesBuilding TechnologiesJune 2005
SiPass networked
Up to 8 dual reader controller / 16 doors
Siemens Building Technologies Fire & Security Products GmbH & Co. oHG
SiPass networked 5 Building TechnologiesBuilding TechnologiesJune 2005
SiPass networked – Graphical user interface is easy to learn and logical to use
Single glance system overview
List of system activity Simple click and drag time programming
All related data on a single page
Siemens Building Technologies Fire & Security Products GmbH & Co. oHG
SiPass networked 6 Building TechnologiesBuilding TechnologiesJune 2005
SiPass networked – Door control unit
• Power supply 100-240 V AC, 50/60 Hz
• Prepared for battery backup
• Two relay outputs (NO/NC) (door opener)
• 5 Inputs(2 REX, 2 DC und 1 Tamper)
• Firmware/database in flash memory
• Connection of up to two card readers
Siemens Building Technologies Fire & Security Products GmbH & Co. oHG
SiPass networked 7 Building TechnologiesBuilding TechnologiesJune 2005
SiPass networked – Connection diagram
240Vac24Vdc Power supply
Door control unitBattery
12V/7.2Ah
(optional)
J5
J12
2
J8
Tamper
2x0,75mm²+2x0,22mm²
J6
2x0,22mm²
2x0,22mm²
2x0,75mm²
Door 1
J7
J10
2x0,22mm²RS232/485
J11
BUS
RELAY1
RELAY2
REX
DOOR FR
AUX IN1
AUX IN2
AUX IN3
Reader 2
J2 12Vdc/1A
Door 2
Reader 1
Siemens Building Technologies Fire & Security Products GmbH & Co. oHG
SiPass networked 8 Building TechnologiesBuilding TechnologiesJune 2005
SiPass networked – Part number explanation
AKN nn nn - xx
41 – Starter kit
42 – Extension kit
00 – without reader
10 – Reader without keypad
20 – Reader with keypad
CP – Proximity reader
MX – Multifunction reader
Siemens Building Technologies Fire & Security Products GmbH & Co. oHG
SiPass networked 9 Building TechnologiesBuilding TechnologiesJune 2005
So
ftwa
re &
Ma
nu
al
RS
23
2/R
S4
85
Co
nve
rte
r
Co
ntr
olle
r in
ho
usi
ng
with
po
we
r su
pp
ly
Re
ad
er
pro
xim
ity
AR
63
31
-CP
Re
ad
er
pro
xim
ity
with
ke
yp
ad
AR
63
32
-CP
Re
ad
er
Mu
ltifu
nct
ion
AR
61
81
-MX
Re
ad
er
Mu
ltifu
nct
ion
with
ke
ypa
d
AR
61
82
-MX
20
Pro
xim
ity c
ard
s
20
Mifa
re c
ard
s
AKN4100 X X X
AKN4200 X
AKN4110-CP X X X X X
AKN4210-CP X X
AKN4120-CP X X X X X
AKN4220-CP X X
AKN4110-MX X X X X X
AKN4210-MX X X
AKN4120-MX X X X X X
AKN4220-MX X X
SiPass networked – Available in Kits for no-hassle, no mistake ordering
Siemens Building Technologies Fire & Security Products GmbH & Co. oHG
SiPass networked 10 Building TechnologiesBuilding TechnologiesJune 2005
SiPass networked – Improvements in the latest release (MP 2.1)
Product enhancements:
•Integration of Siemens biometric fingertip reader•«SiPass networked» now supports the most popular
installed access control readers• Support for HID / Kerry compatible Wiegand readers
• Flexible Wiegand format definition is adaptable to most installed readers
•Automatic reader reset after reader tamper
•Use second relay as intrusion interface in one door mode
•Manual relay commands
•Export database in «SiPass integrated» format for migration
•CE, C-Tick approvals
Siemens Building Technologies Fire & Security Products GmbH & Co. oHG
SiPass networked 11 Building TechnologiesBuilding TechnologiesJune 2005
SiPass networked –Integration of Siemens biometric reader
• Fingertip reader AR6332-BI in mullion reader design
• Identification or verification with PIN
• Up to 450 patterns
• Download of the patterns via LAN
• Compatible with other Siemens readers
Siemens Building Technologies Fire & Security Products GmbH & Co. oHG
SiPass networked 12 Building TechnologiesBuilding TechnologiesJune 2005
Easy upgrade path to «SiPass integrated» allows the system to grow with the customer
Hardware components and database are reused:
• Change firmware of the «SiPass networked» controller with «SiPass integrated» tools
• Use of the same card technology
• And SiPass also fully supports other card technologies
• Export database in «SiPass integrated» format
• Move the «SiPass networked» controller cable from the PC to the ACC
• Install «SiPass integrated» , and import the database
SiPass networked –Upgrade to SiPass integrated
Siemens Building Technologies Fire & Security Products GmbH & Co. oHG
SiPass networked 13 Building TechnologiesBuilding TechnologiesJune 2005
SiPass networked –Upgrade to SiPass integrated
SiPass Client workstation
SiPass Client workstation
SiPass Server
ACCACC
In reader
Exit reader
ACC
DRIOPM IPM
WAN/LAN
ACC
RS485
Inreader
Exitreader
Siemens Building Technologies Fire & Security Products GmbH & Co. oHG
SiPass networked 14 Building TechnologiesBuilding TechnologiesJune 2005
SiPass networked
A simple and effective Access Control System to secure and monitor up to 16 doors.
Summary