caratteristiche tecniche technical features act es - … · (punto di rugiada a pressione...

2
ACT ES - ACT VS Energy Saving Dryer Series CARATTERISTICHE TECNICHE TECHNICAL FEATURES I dati riportati sono riferiti alle seguenti condizioni nominali: temperatura ambiente 25°C, con aria in ingresso a 7 barg e 35°C e un punto di rugiada in pressione di 3°C (punto di rugiada a pressione atmosferica -22°C). Max. condizioni di esercizio : temperatura ambiente 50°C per gli ES e 45°C per i VS, temperatura ingresso aria 70°C e pressione ingresso aria 14 barg (16 barg ACT 3…12 ES). Data refer to the following nominal conditions: ambient temperature of 25°C, with inlet air at 7 barg and 35°C and 3°C pressure Dew Point (-22°C atmospheric pressure Dew Point). Max. working conditions: ambient temperature 50°C for ES models, 45°C for VS models, inlet air temperature 70°C and inlet air pressure 14 barg (16 barg ACT 3…12 ES). Friulair S.r.l. Via Cisis, 36 - S.S. 352 km 21 - Fraz. Strassoldo 33052 Cervignano del Friuli (UD) - Italy Tel. +39.0431.939416 Fax +39.0431.939419 e-mail: [email protected], www.friulair.com “La Friulair S.r.l. si riserva il diritto di apportare modifiche tecniche senza alcun preavviso, errori ed omissioni non esclusi” “Friulair S.r.l reserves the right to make technical changes without prior notice, errors and omissions excepted” FATTORE DI CORREZIONE AL VARIARE DELLA PRESSIONE DI ESERCIZIO / CORRECTION FACTOR FOR OPERATING PRESSURE CHANGES: Pressione aria entrata / Inlet air pressure barg 4 0.77 5 0.86 6 0.93 7 1.00 8 1.05 10 1.14 12 1.21 14 1.27 Fattore / Factor FATTORE DI CORREZIONE AL VARIARE DELLA TEMP. AMBIENTE / CORRECTION FACTOR FOR AMBIENT TEMPERATURE CHANGES: Temperatura aria / Ambient temperature °C 25 1.00 30 0.96 35 0.90 40 0.82 45 0.72 50 0.60 Fattore / Factor FATTORE DI CORREZIONE AL VARIARE DELLA TEMP. ARIA ENTRATA / CORRECTION FACTOR FOR INLET AIR TEMPERATURE CHANGES: Temperatura aria / Air temperature °C 25 1.20 30 1.12 35 1.00 40 0.83 45 0.69 50 0.59 55 0.50 60 65 70 0.44 0.39 0.37 Fattore / Factor FATTORE DI CORREZIONE AL VARIARE DEL PUNTO DI RUGIADA (DEW POINT) / CORRECTION FACTOR FOR DEW POINT CHANGES: Punto di rugiada / Dew Point °C 3 1.00 5 1.09 7 1.19 10 1.37 Fattore / Factor MADE IN ITALY E N V I R O M E N T A L L Y F R I E N D L Y ISO 9001 C E R T I F I E D Q U A L I T Y S Y S T E M ACT 210 VS ACT 300 VS ACT 360 VS ACT 400 VS ACT 600 VS ACT 720 VS ACT 900 VS ACT 1100 VS ACT 1200 VS ACT 1500 VS ACT 1800 VS 3/400/50 3/400/50 3/400/50 3/400/50 3/400/50 3/400/50 3/400/50 3/400/50 3/400/50 3/400/50 3/400/50 248 282 317 470 549 621 843 954 1.071 1.218 1.450 0.21 0.19 0.26 0.21 0.20 0.26 0.20 0.26 0.20 0.26 0.22 790 790 790 1.135 1.135 1.135 1.300 1.300 1.400 1.400 1.547 1.000 1.000 1.000 1.205 1.205 1.205 1.750 1.750 2.200 2.200 2.270 1.465 1.465 1.465 1.745 1.745 1.745 1.810 1.810 1.870 1.870 2.440 R 134.a R 407C R 407C R 407C R 407C R 407C R 407C R 407C R 407C R 407C R 407C DN80 PN16 DN80 PN16 DN80 PN16 DN100 PN16 DN100 PN16 DN100 PN16 DN150 PN16 DN150 PN16 DN200 PN16 DN200 PN16 DN200 PN16 1.260 1.800 2.208 2.400 3.600 4.416 5.400 6.624 7.200 8.832 10.800 21.000 30.000 36.800 40.000 60.000 73.600 90.000 110.400 120.000 147.200 180.000 742 1.060 1.300 1.413 2.119 2.600 3.178 3.900 4.238 5.200 6.360 Modello Model Refrig. Refrig. Attacchi Connections Alimentazione Power Supply PesoPower Weight Caduta di Pressione Pressure Drop Portata Flow-Rate Dimensioni [mm] Dimensions [mm] [Type] [l/min] A [m3/h] B [scfm] C [ Ø ] [Ph/V/Fr] [kg] R 134.a R 134.a R 134.a R 134.a R 134.a R 134.a R 407C R 407C R 407C R 407C R 407C R 407C R 407C R 407C R 407C R 134.a R 134.a R 134.a R 134.a R 407C R 407C R 407C G 1/2” BSP-F G 1/2” BSP-F G 1/2” BSP-F G 1/2” BSP-F G 1” BSP-F G 1” BSP-F G 1.1/4” BSP-F G 1.1/4” BSP-F G 1.1/2” BSP-F G 1.1/2” BSP-F G 2” BSP-F G 2” BSP-F G 2.1/2” BSP-F G 2.1/2” BSP-F G 2.1/2” BSP-F G 1.1/2” BSP-F G 1.1/2” BSP-F G 2” BSP-F G 2” BSP-F G 2.1/2” BSP-F G 2.1/2” BSP-F G 2.1/2” BSP-F 1/230/50-60 1/230/50-60 1/230/50-60 1/230/50-60 1/230/50-60 1/230/50 1/230/50 1/230/50 1/230/50 1/230/50 1/230/50 1/230/50 1/230/50 1/230/50 1/230/50 3/400/50 3/400/50 3/400/50 3/400/50 3/400/50 3/400/50 3/400/50 28 29 31 34 36 36 49 50 60 63 92 94 141 150 161 72 75 100 102 158 160 170 0.02 0.03 0.08 0.11 0.13 0.17 0.15 0.20 0.15 0.18 0.09 0.13 0.07 0.13 0.15 0.15 0.18 0.09 0.13 0.07 0.13 0.15 21 33 51 72 108 138 186 240 330 372 486 630 750 870 960 330 372 486 630 750 870 960 345 345 345 345 345 345 485 485 555 555 555 555 665 665 665 555 555 555 555 665 665 665 350 550 850 1.200 1.800 2.300 3.100 4.000 5.500 6.200 8.100 10.500 12.500 14.500 16.000 5.500 6.200 8.100 10.500 12.500 14.500 16.000 420 420 420 420 420 420 455 455 580 580 625 625 725 725 725 580 580 625 625 725 725 725 12 19 30 42 64 81 109 141 194 219 286 371 441 512 565 194 219 286 371 441 512 565 740 740 740 740 740 740 825 825 885 885 975 975 1.105 1.105 1.105 885 885 975 975 1.105 1.105 1.105 ACT 3 ES ACT 5 ES ACT 8 ES ACT 12 ES ACT 18 ES ACT 23 ES ACT 30 ES ACT 40 ES ACT 55 ES ACT 60 ES ACT 80 ES ACT 100 ES ACT 120 ES ACT 140 ES ACT 160 ES ACT 55 ES 3~ ACT 60 ES 3~ ACT 80 ES 3~ ACT 100 ES 3~ ACT 120 ES 3~ ACT 140 ES 3~ ACT 160 ES 3~ Su richiesta modelli ACT23…1800 con alimentazione a 60Hz - On request models ACT23…1800 with 60Hz power supply. [bar] Edizione Aprile 2017

Upload: others

Post on 05-Feb-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: CARATTERISTICHE TECNICHE TECHNICAL FEATURES ACT ES - … · (punto di rugiada a pressione atmosferica -22°C). Max. condizioni di esercizio : temperatura ambiente 50°C per gli ES

ACT ES - ACT VSEnergy Saving Dryer Series

CARATTERISTICHE TECNICHETECHNICAL FEATURESI dati riportati sono riferiti alle seguenti condizioni nominali: temperatura ambiente 25°C, con aria in ingresso a 7 barg e 35°C e un punto di rugiada in pressione di 3°C (punto di rugiada a pressione atmosferica -22°C). Max. condizioni di esercizio : temperatura ambiente 50°C per gli ES e 45°C per i VS, temperatura ingresso aria 70°C e pressione ingresso aria 14 barg (16 barg ACT 3…12 ES).

Data refer to the following nominal conditions: ambient temperature of 25°C, with inlet air at 7 barg and 35°C and 3°C pressure Dew Point (-22°C atmospheric pressure Dew Point). Max. working conditions: ambient temperature 50°C for ES models, 45°C for VS models, inlet air temperature 70°C and inlet air pressure 14 barg (16 barg ACT 3…12 ES).

Friulair S.r.l. Via Cisis, 36 - S.S. 352 km 21 - Fraz. Strassoldo33052 Cervignano del Friuli (UD) - ItalyTel. +39.0431.939416 Fax +39.0431.939419e-mail: [email protected], www.friulair.com

“La Friulair S.r.l. si riserva il diritto di apportare modifiche tecniche senza alcun preavviso, errori ed omissioni non esclusi”“Friulair S.r.l reserves the right to make technical changes without prior notice, errors and omissions excepted”

FATTORE DI CORREZIONE AL VARIARE DELLA PRESSIONE DI ESERCIZIO / CORRECTION FACTOR FOR OPERATING PRESSURE CHANGES:Pressione aria entrata / Inlet air pressure barg 4

0.775

0.866

0.937

1.008

1.0510

1.14 12

1.2114

1.27Fattore / Factor

FATTORE DI CORREZIONE AL VARIARE DELLA TEMP. AMBIENTE / CORRECTION FACTOR FOR AMBIENT TEMPERATURE CHANGES:Temperatura aria / Ambient temperature °C 25

1.0030

0.9635

0.9040

0.8245

0.7250

0.60 Fattore / Factor

FATTORE DI CORREZIONE AL VARIARE DELLA TEMP. ARIA ENTRATA / CORRECTION FACTOR FOR INLET AIR TEMPERATURE CHANGES:Temperatura aria / Air temperature °C 25

1.2030

1.1235

1.0040

0.8345

0.6950

0.59 55

0.5060 65 70

0.44 0.39 0.37Fattore / Factor

FATTORE DI CORREZIONE AL VARIARE DEL PUNTO DI RUGIADA (DEW POINT) / CORRECTION FACTOR FOR DEW POINT CHANGES:Punto di rugiada / Dew Point °C 3

1.005

1.097

1.1910

1.37Fattore / Factor

MADE IN ITALY

ENVIROME

NTALLY FRIENDLY ISO 9001

CERTIFIED

QUALITY SYSTEM

ACT 210 VSACT 300 VSACT 360 VSACT 400 VSACT 600 VSACT 720 VSACT 900 VSACT 1100 VSACT 1200 VSACT 1500 VSACT 1800 VS

3/400/503/400/503/400/503/400/503/400/503/400/503/400/503/400/503/400/503/400/503/400/50

248282317470549621843954

1.0711.2181.450

0.210.190.260.210.200.260.200.260.200.260.22

790790790

1.1351.1351.1351.3001.3001.4001.4001.547

1.0001.0001.0001.2051.2051.2051.7501.7502.2002.2002.270

1.4651.4651.4651.7451.7451.7451.8101.8101.8701.8702.440

R 134.aR 407CR 407CR 407CR 407CR 407CR 407CR 407CR 407CR 407CR 407C

DN80 PN16DN80 PN16DN80 PN16DN100 PN16DN100 PN16DN100 PN16DN150 PN16DN150 PN16DN200 PN16DN200 PN16DN200 PN16

1.2601.8002.2082.4003.6004.4165.4006.6247.2008.83210.800

21.00030.00036.80040.00060.00073.60090.000110.400120.000147.200180.000

7421.0601.3001.4132.1192.6003.1783.9004.2385.2006.360

ModelloModel

Refrig.Refrig.

AttacchiConnections

AlimentazionePower Supply

PesoPower Weight

Caduta di PressionePressure Drop

PortataFlow-Rate

Dimensioni [mm]Dimensions [mm]

[Type] [l/min] A[m3/h] B[scfm] C[ Ø ] [Ph/V/Fr] [kg]R 134.aR 134.aR 134.aR 134.aR 134.aR 134.aR 407CR 407CR 407CR 407CR 407CR 407CR 407CR 407CR 407CR 134.aR 134.aR 134.aR 134.aR 407CR 407CR 407C

G 1/2” BSP-FG 1/2” BSP-FG 1/2” BSP-FG 1/2” BSP-FG 1” BSP-FG 1” BSP-F

G 1.1/4” BSP-FG 1.1/4” BSP-FG 1.1/2” BSP-FG 1.1/2” BSP-F

G 2” BSP-FG 2” BSP-F

G 2.1/2” BSP-FG 2.1/2” BSP-FG 2.1/2” BSP-FG 1.1/2” BSP-FG 1.1/2” BSP-F

G 2” BSP-FG 2” BSP-F

G 2.1/2” BSP-FG 2.1/2” BSP-FG 2.1/2” BSP-F

1/230/50-601/230/50-601/230/50-601/230/50-601/230/50-60

1/230/501/230/501/230/501/230/501/230/501/230/501/230/501/230/501/230/501/230/503/400/503/400/503/400/503/400/503/400/503/400/503/400/50

282931343636495060639294

1411501617275

100102158160170

0.020.030.080.110.130.170.150.200.150.180.090.130.070.130.150.150.180.090.130.070.130.15

21335172108138186240330372486630750870960330372486630750870960

345345345345345345485485555555555555665665665555555555555665665665

350550850

1.2001.8002.3003.1004.0005.5006.2008.10010.50012.50014.50016.0005.5006.2008.10010.50012.50014.50016.000

420420420420420420455455580580625625725725725580580625625725725725

121930426481109141194219286371441512565194219286371441512565

740740740740740740825825885885975975

1.1051.1051.105885885975975

1.1051.1051.105

ACT 3 ESACT 5 ESACT 8 ESACT 12 ESACT 18 ESACT 23 ESACT 30 ESACT 40 ESACT 55 ESACT 60 ESACT 80 ESACT 100 ESACT 120 ESACT 140 ESACT 160 ES

ACT 55 ES 3~ACT 60 ES 3~ACT 80 ES 3~ACT 100 ES 3~ACT 120 ES 3~ACT 140 ES 3~ACT 160 ES 3~

Su richiesta modelli ACT23…1800 con alimentazione a 60Hz - On request models ACT23…1800 with 60Hz power supply.

[bar]

Ediz

ione

Apr

ile 2

017

Page 2: CARATTERISTICHE TECNICHE TECHNICAL FEATURES ACT ES - … · (punto di rugiada a pressione atmosferica -22°C). Max. condizioni di esercizio : temperatura ambiente 50°C per gli ES

L’ESSICCATORE FINALIZZATO AL RISPARMIO ENERGETICOL’EVOLUZIONE DELLA SERIE ACT FRIULAIRTHE ENERGY SAVING DRYER THE EVOLUTION OF THE ACT FRIULAIR SERIES

I modelli ACT ES sono equipaggiati dell’innovativo strumento elettronico DMC51 che monitorando costantemente la temperatura di Dew Point comanda l’accensione e lo spegnimento del compressore frigorifero. Quando la temperatura

si avvicina alla soglia minima lo strumento spegne il compressore; successivamente, all’aumentare della temperatura, il compressore viene riacceso. Le caratteristiche dello scambiatore in alluminio ALU-DRY abbinate all’applicazione di una serie di valvole, combinano la funzione di massa termica ai vantaggi del sistema a espansione diretta.

The ACT ES models are equipped with an innovative DMC51 electronic controller which measures the Dew Point temperature and controls the switching on and off of the refrigerant compressor. When the temperature approaches the minimum threshold the DMC51 switches off the compressor; then, when temperature increases, the compressor is turned on again. The characteristics of the ALU-DRY aluminium heat exchanger and the application of a series of valves combine the function of a thermal mass with the advantages of a direct expansion system.

ACT 3…160 ES

ACT 210…1800 VSLa totale gestione dell’essiccatore ACT VS è affidata all’innovativo controllore DMC50, il quale monitorando costantemente i valori di pressioni e temperature di funzionamento, calcola l’attuale carico termico e regola di conseguenza la velocità di rotazione del compressore e dei ventilatori. In questo modo viene garantito un dewpoint estremamente stabile a qualsiasi condizione operativa ed un

consumo elettrico pressoché proporzionale all’effettivo carico termico applicato. Il display di tipo touch screen oltre ad essere particolarmente ampio e ricco di informazioni offre un’interfaccia intuitiva per l’operatore. I parametri attuali di funzionamento sono costantemente visualizzati, mentre ulteriori informazioni quali data logger, manutenzioni programmate, conta ore, risparmio energetico e accesso alla memoria degli allarmi, sono facilmente consultabili. L’interfaccia RS485 è già inclusa per una gestione remota dell’essiccatore.

The complete management of the ACT VS dryer is entrusted to the innovative DMC50 electronic control unit, which continuously monitors the pressure and operating temperature, calculates the heat load and adjusts the rotation speed of the compressor and fans. This ensures an extremely stable Dew Point in all operating conditions and a power consumption proportional to the applied heat load. The large touch screen display, rich in information, provides an intuitive operator interface. The current operating parameters are constantly displayed, while additional information such as data loggers, scheduled maintenance, hour meter, energy saving and memory of the alarms, are easily accessible. The RS485 interface is already included for remote management of the dryer.

FRIULAIR introduce la gamma completa di essiccatori ACT ES - ACT VS Energy Saving nata dall’esigenza di abbinare la qualità del trattamento dell’aria compressa al risparmio energetico. La nuova gamma si avvale delle caratteristiche costruttive della serie ACT, già apprezzate dal mercato dell’industria dell’aria compressa, combinate a soluzioni innovative volte a ottimizzare il consumo elettrico.

FRIULAIR has released the full range of ACT ES and ACT VS Energy Saving dryers. This new range comes from the need to match compressed air treatment quality with energy saving. The new range uses the design characteristics of the ACT series, which are already appreciated by the compressed air industry market, combined with innovative solutions focused to reduce the electric consumption.

QUANTO SI RISPARMIA CON L’ESSICCATORE ACT ENERGY SAVINGHOW MUCH CAN BE SAVED WITH AN ACT ENERGY SAVING DRYER

LA GAMMA - THE RANGESulla consolidata base della serie ACT (standard) é stata sviluppata la gamma ACT Energy Saving nelle versioni ACT 3...160 ES e ACT 210...1800 VS cosí distinte in funzione della tecnologia applicata.

From the ACT series bases (standard) has been developed the ACT Energy Saving range in the versions of ACT 3...160 ES and ACT 210...1800 VS depending on the applied technolgy.

SCARICATORE DI CONDENSA - DRAIN CONDENSATE SYSTEMPer ottimizzare il risparmio eneregetico l’intera gamma ACT ES - ACT VS è dotata di uno scaricatore capacitivo di tipo Zero Loss Drain.

To maximize the Energy Savings the full ACT ES and ACT VS range is equipped with an electronic Zero Loss Drain.

E’ buona norma dimensionare gli essiccatori considerando le condizioni operative piu’ gravose specifiche dell’installazione, ovvero alla portata massima di impianti con forti variazioni di carico ed alle temperature massime ambiente e dell’aria compressa anche in paesi soggetti a escursioni termiche stagionali. In questo modo l’essiccatore ACT (standard), pur garantendo prestazioni ottimali in tutte le condizioni operative, ha un consumo energetico pressoché costante anche in situazioni di carico ridotto. GLI ESSICCATORI ACT ES-ACT VS INVECE SONO IN GRADO DI ADATTARE IL PROPRIO CONSUMO ENERGETICO IN FUNZIONE DEL CARICO APPLICATO CONSENTENDO UN NOTEVOLE RISPARMIO ECONOMICO ALLE CONDIZIONI TIPICHE DI UTILIZZO.

PERCHE’ SCEGLIERE L’ESSICCATORE ACT ENERGY SAVINGWHY CHOOSE THE ENERGY ACT SAVING DRYER

As known the sizing of the dryer is made considering the worst case working conditions of that specific installation. That means the maximum flow rate capacity in plants with strong load variations and the maximum ambient and compressed air temperatures in countries subjected to seasonal temperature difference. For these applications the ACT (standard), while ensuring optimum performance in all operating conditions, has a nearly constant power consumption even in reduced load situations. HOWEVER THE ACT ES AND ACT VS DRYERS ARE ABLE TO ADAPT THEIR ENERGY CONSUMPTION IN ACCORDING TO THE LOAD AND ALLOW SUBSTANTIAL ECONOMIC SAVINGS EVEN WHEN APPLIED TO TYPICAL CONDITIONS.

I due grafici mettono a confronto il consumo elettrico medio dei modelli ACT Energy Saving rispetto all’equivalente modello ACT (standard) alle diverse condizioni di carico.Le curve dei grafici evidenziano l’efficienza energetica delle versioni ACT ES e ACT VS e consentono di calcolare il risparmio energetico, e quindi economico, in condizioni di carico ridotto.

The two graphs compare the average power consumption of the ACT Energy Saving models compared to the equivalent ACT (standard) model at different load conditions.The curves of the graphs show the ACT ES and ACT VS versions’ energy efficiency and allow to calculate the energy savings, and so economic, at reduced loading conditions.

PATENT PENDING