chairman : dr.hung -chi yang presenter : ping-yang liao adviser : dr. yi-chun du
DESCRIPTION
A determination of the existence of a relationship between applied occlusal load and dental articulating paper mark area. Chairman : Dr.Hung -Chi Yang Presenter : Ping-Yang Liao Adviser : Dr. Yi-Chun Du. By Jason P. Carey, Mark Craig, Robert B. Kerstein and John Radke - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: Chairman : Dr.Hung -Chi Yang Presenter : Ping-Yang Liao Adviser : Dr. Yi-Chun Du](https://reader033.vdocuments.pub/reader033/viewer/2022061413/5681671f550346895ddba082/html5/thumbnails/1.jpg)
A determination of the existence of a relationship between applied
occlusal load and dental articulating paper mark area
Chairman: Dr.Hung-Chi YangPresenter: Ping-Yang LiaoAdviser: Dr. Yi-Chun Du
By Jason P. Carey, Mark Craig, Robert B. Kerstein and John RadkeThe Open Dentistry Journal
![Page 2: Chairman : Dr.Hung -Chi Yang Presenter : Ping-Yang Liao Adviser : Dr. Yi-Chun Du](https://reader033.vdocuments.pub/reader033/viewer/2022061413/5681671f550346895ddba082/html5/thumbnails/2.jpg)
Introduction Material and Methods Results Discussion and Conclusions References
Outline
![Page 3: Chairman : Dr.Hung -Chi Yang Presenter : Ping-Yang Liao Adviser : Dr. Yi-Chun Du](https://reader033.vdocuments.pub/reader033/viewer/2022061413/5681671f550346895ddba082/html5/thumbnails/3.jpg)
IntroductionArticulating paper mark size has been
widely accepted in the dental community to be descriptive of occlusal load.
The objective of this study is to determine if any direct relationship exists between articulating paper mark area and applied occlusal load.
![Page 4: Chairman : Dr.Hung -Chi Yang Presenter : Ping-Yang Liao Adviser : Dr. Yi-Chun Du](https://reader033.vdocuments.pub/reader033/viewer/2022061413/5681671f550346895ddba082/html5/thumbnails/4.jpg)
IntroductionT-Scan III
![Page 5: Chairman : Dr.Hung -Chi Yang Presenter : Ping-Yang Liao Adviser : Dr. Yi-Chun Du](https://reader033.vdocuments.pub/reader033/viewer/2022061413/5681671f550346895ddba082/html5/thumbnails/5.jpg)
Material and MethodsArticulating paper
Natural tooth occlusal adjustments Dental prosthesis
Occlusal contact intensity, Evenness, and Simultaneity
![Page 6: Chairman : Dr.Hung -Chi Yang Presenter : Ping-Yang Liao Adviser : Dr. Yi-Chun Du](https://reader033.vdocuments.pub/reader033/viewer/2022061413/5681671f550346895ddba082/html5/thumbnails/6.jpg)
Material and Methods
Variables to eliminate that will interfere with consistent Paper Marking per testTooth movement during loading
![Page 7: Chairman : Dr.Hung -Chi Yang Presenter : Ping-Yang Liao Adviser : Dr. Yi-Chun Du](https://reader033.vdocuments.pub/reader033/viewer/2022061413/5681671f550346895ddba082/html5/thumbnails/7.jpg)
Variables to eliminate that will interfere with consistent Paper Marking per test
Tooth wear from repeated loadingMandibular flexureSalivaAngular mandibular movement
![Page 8: Chairman : Dr.Hung -Chi Yang Presenter : Ping-Yang Liao Adviser : Dr. Yi-Chun Du](https://reader033.vdocuments.pub/reader033/viewer/2022061413/5681671f550346895ddba082/html5/thumbnails/8.jpg)
Material and MethodsMTS uniaxial testing
machine (MTS Systems Corporation, Eden Prairie, MN, USA.)
A uniaxial testing machine repeatedly applied a compressive load
Fig. (1). MTS testing machine - open prior to test.
![Page 9: Chairman : Dr.Hung -Chi Yang Presenter : Ping-Yang Liao Adviser : Dr. Yi-Chun Du](https://reader033.vdocuments.pub/reader033/viewer/2022061413/5681671f550346895ddba082/html5/thumbnails/9.jpg)
Material and Methods
Fig. (2). MTS testing machine - closed with casts intercuspated and articulating paper horseshoe interposed.
Self-calibrating / zeroing program that was calibrated and zeroed prior
The dental cast base plates were secured to the MTS by means of machined rods with alignment holes that ensured precise alignment.
![Page 10: Chairman : Dr.Hung -Chi Yang Presenter : Ping-Yang Liao Adviser : Dr. Yi-Chun Du](https://reader033.vdocuments.pub/reader033/viewer/2022061413/5681671f550346895ddba082/html5/thumbnails/10.jpg)
Material and Methods
Fig. (3). Photographic set up–camera placed at 900 directly over cast.
25N~450NA total of 600 (n =
12 Area x 10 force levels x 5 repetitions = 600)
ImageJ software (developed at the National Institutes of Health, Washington, DC, USA)
![Page 11: Chairman : Dr.Hung -Chi Yang Presenter : Ping-Yang Liao Adviser : Dr. Yi-Chun Du](https://reader033.vdocuments.pub/reader033/viewer/2022061413/5681671f550346895ddba082/html5/thumbnails/11.jpg)
Material and Methods
Fig. (4). Maxillary cast - 6 consistent red articulating paper markings.
Fig. (5). Mandibular cast-6 consistent blue articulating paper markings.
![Page 12: Chairman : Dr.Hung -Chi Yang Presenter : Ping-Yang Liao Adviser : Dr. Yi-Chun Du](https://reader033.vdocuments.pub/reader033/viewer/2022061413/5681671f550346895ddba082/html5/thumbnails/12.jpg)
Similar sized marks on nearby teeth = similar loads
![Page 13: Chairman : Dr.Hung -Chi Yang Presenter : Ping-Yang Liao Adviser : Dr. Yi-Chun Du](https://reader033.vdocuments.pub/reader033/viewer/2022061413/5681671f550346895ddba082/html5/thumbnails/13.jpg)
Similar sized marks on nearby teeth = similar loads
![Page 14: Chairman : Dr.Hung -Chi Yang Presenter : Ping-Yang Liao Adviser : Dr. Yi-Chun Du](https://reader033.vdocuments.pub/reader033/viewer/2022061413/5681671f550346895ddba082/html5/thumbnails/14.jpg)
Results Incremental load increase did not result in an equal
incremental Mark Area size increase on any individual tooth.
Highest loads yielded smaller markings than median loads.
At lower occlusal loads, paper mark size may not show any increase in Mark Area as loads increase.
Only 21% of the time did similar loads result in similar Mark Area (120/600 marks)
![Page 15: Chairman : Dr.Hung -Chi Yang Presenter : Ping-Yang Liao Adviser : Dr. Yi-Chun Du](https://reader033.vdocuments.pub/reader033/viewer/2022061413/5681671f550346895ddba082/html5/thumbnails/15.jpg)
Discussion and Conclusions It is not possible to determine from the Mark
Area of multiple marks on multiple teeth which contact has the most applied load.
Choosing the most forceful contact(s) based upon Mark Area (size) is an erroneous process.
The data suggests that, similar sized marks do not demonstrate “evenness and equal intensity intensity”.
![Page 16: Chairman : Dr.Hung -Chi Yang Presenter : Ping-Yang Liao Adviser : Dr. Yi-Chun Du](https://reader033.vdocuments.pub/reader033/viewer/2022061413/5681671f550346895ddba082/html5/thumbnails/16.jpg)
References• [1] Dawson PE. Functional occlusion: from TMJ to smile design. Vol. 1. St. Louis (MO): Mosby and Co. 2007. p. 347.• [2] Glickman I. Clinical Periodontics. 5th ed. Philadelphia (PA): Saunders and Co; 1979. p 951.• [3] McNeil C. Science and practice of occlusion. Carol Stream (IL): Quintessence Publishing; 1997. p 421.• [4] Harper KA, Setchell DA. The use of shimstock to assess occlusal contacts; a laboratory study. Int J Prosthodont.
2002;15:347-52.• [5] Okeson, J. Management of temporomandibular disorders and occlusion. 5th ed. St. Louis, (MO) Mosby and Co,
2003. p. 416, 418, 605.• [6] Kleinberg I. Occlusion practice and assessment. Oxford (UK): Knight Publishing; 1991. p 128.• [7] Smukler H. Equilibration in the natural and restored dentition. Chicago (IL): Quintessence Publishing; 1991. p.
110.• [8] Kerstein RB, Grundset K. Obtaining bilateral simultaneous occlusal contacts with computer analyzed and guided
occlusal adjustments. Quintessence Int. 2001; 32: 7-18.• [9] Kerstein RB, Lowe M, Harty M, Radke J. A Force reproduction analysis of two recording sensors of a
computerized occlusal analysis system. Cranio. 2006; 24: 15-24.• [10] Schelb E, Kaiser D, and Brukl C. Thickness and marking characteristics of occlusal registration strips. J Prosthet
Dent1985; 54: 122-6.• [11] Halperin G, Halperin A, Norling B. Thickness, strength, and plastic deformation of occlusal registration strips. J
Prosthet Dent 1982; 48: 575-8.• [12] Lyons MF, Cadden SW, Baxendale RH, Yemm R. Twitch interpolation in the assessment of the maximum force-
generating capacity of the jaw-closing muscles in man. Arch Oral Biol 1996; 41: 1161-8.• [13] Proeschel PA, Morneburg T. Task-dependence of activity/ biteforce relations and its impact on estimation of
chewing force from EMG. J Dent Res 2002; 81: 464-8.
![Page 17: Chairman : Dr.Hung -Chi Yang Presenter : Ping-Yang Liao Adviser : Dr. Yi-Chun Du](https://reader033.vdocuments.pub/reader033/viewer/2022061413/5681671f550346895ddba082/html5/thumbnails/17.jpg)
T-Scan®Computerized Occlusal Analysis
Chairman: Dr.Hung-Chi YangPresenter: Ping-Yang LiaoAdviser: Dr. Yi-Chun Du
Tekscan, Inc, Boston, MA
![Page 18: Chairman : Dr.Hung -Chi Yang Presenter : Ping-Yang Liao Adviser : Dr. Yi-Chun Du](https://reader033.vdocuments.pub/reader033/viewer/2022061413/5681671f550346895ddba082/html5/thumbnails/18.jpg)
Introduction T-Scan III technology is a bite analysis
system that measures the efficiency of how teeth come together and separate to protect natural teeth, restored teeth, implants, and muscles.
![Page 19: Chairman : Dr.Hung -Chi Yang Presenter : Ping-Yang Liao Adviser : Dr. Yi-Chun Du](https://reader033.vdocuments.pub/reader033/viewer/2022061413/5681671f550346895ddba082/html5/thumbnails/19.jpg)
Sensor and Support Handle assembly Computer software Printer
![Page 20: Chairman : Dr.Hung -Chi Yang Presenter : Ping-Yang Liao Adviser : Dr. Yi-Chun Du](https://reader033.vdocuments.pub/reader033/viewer/2022061413/5681671f550346895ddba082/html5/thumbnails/20.jpg)
![Page 21: Chairman : Dr.Hung -Chi Yang Presenter : Ping-Yang Liao Adviser : Dr. Yi-Chun Du](https://reader033.vdocuments.pub/reader033/viewer/2022061413/5681671f550346895ddba082/html5/thumbnails/21.jpg)
Two modes 1. Time analysis 2. Force analysis *Provides information on the location
and timing of contact displaying on the screen with the first , second and third or more contact in different colour.
*Relative force in 5 different colours. * Instant * Sequential
![Page 22: Chairman : Dr.Hung -Chi Yang Presenter : Ping-Yang Liao Adviser : Dr. Yi-Chun Du](https://reader033.vdocuments.pub/reader033/viewer/2022061413/5681671f550346895ddba082/html5/thumbnails/22.jpg)
Order of occlusal contact while simultaneously measures the changes in force percentages of the same contacting to maximum intercuspation.
1. Premature contact and interference can be identified. 2. Centre of Occlusal force(COF) , Asymmetry index of occlusal force(AOF). 3. Disclusion time and Clusion time. 4. Implant Restorative Dentistry. 5. Temporomandibular Disorder 6. Orthodontics. 7. Prosthodontics 8. Oral and maxillofacial surgery.
![Page 23: Chairman : Dr.Hung -Chi Yang Presenter : Ping-Yang Liao Adviser : Dr. Yi-Chun Du](https://reader033.vdocuments.pub/reader033/viewer/2022061413/5681671f550346895ddba082/html5/thumbnails/23.jpg)
Improrperly restored tooth can cause several problem like
* Headache * TMD related problem * Fracture of tooth / restoration * Save time of finishing of restoration.
![Page 24: Chairman : Dr.Hung -Chi Yang Presenter : Ping-Yang Liao Adviser : Dr. Yi-Chun Du](https://reader033.vdocuments.pub/reader033/viewer/2022061413/5681671f550346895ddba082/html5/thumbnails/24.jpg)
Thanks for your attention
![Page 25: Chairman : Dr.Hung -Chi Yang Presenter : Ping-Yang Liao Adviser : Dr. Yi-Chun Du](https://reader033.vdocuments.pub/reader033/viewer/2022061413/5681671f550346895ddba082/html5/thumbnails/25.jpg)
T-Scan®Computerized Occlusal Analysis
Chairman: Dr.Hung-Chi YangPresenter: Ping-Yang LiaoAdviser: Dr. Yi-Chun Du
Tekscan, Inc, Boston, MA
![Page 26: Chairman : Dr.Hung -Chi Yang Presenter : Ping-Yang Liao Adviser : Dr. Yi-Chun Du](https://reader033.vdocuments.pub/reader033/viewer/2022061413/5681671f550346895ddba082/html5/thumbnails/26.jpg)
Introduction T-Scan III technology is a bite analysis
system that measures the efficiency of how teeth come together and separate to protect natural teeth, restored teeth, implants, and muscles.
![Page 27: Chairman : Dr.Hung -Chi Yang Presenter : Ping-Yang Liao Adviser : Dr. Yi-Chun Du](https://reader033.vdocuments.pub/reader033/viewer/2022061413/5681671f550346895ddba082/html5/thumbnails/27.jpg)
Sensor and Support Handle assembly Computer software Printer
![Page 28: Chairman : Dr.Hung -Chi Yang Presenter : Ping-Yang Liao Adviser : Dr. Yi-Chun Du](https://reader033.vdocuments.pub/reader033/viewer/2022061413/5681671f550346895ddba082/html5/thumbnails/28.jpg)
![Page 29: Chairman : Dr.Hung -Chi Yang Presenter : Ping-Yang Liao Adviser : Dr. Yi-Chun Du](https://reader033.vdocuments.pub/reader033/viewer/2022061413/5681671f550346895ddba082/html5/thumbnails/29.jpg)
Two modes 1. Time analysis 2. Force analysis *Provides information on the location
and timing of contact displaying on the screen with the first , second and third or more contact in different colour.
*Relative force in 5 different colours. * Instant * Sequential
![Page 30: Chairman : Dr.Hung -Chi Yang Presenter : Ping-Yang Liao Adviser : Dr. Yi-Chun Du](https://reader033.vdocuments.pub/reader033/viewer/2022061413/5681671f550346895ddba082/html5/thumbnails/30.jpg)
Order of occlusal contact while simultaneously measures the changes in force percentages of the same contacting to maximum intercuspation.
1. Premature contact and interference can be identified. 2. Centre of Occlusal force(COF) , Asymmetry index of occlusal force(AOF). 3. Disclusion time and Clusion time. 4. Implant Restorative Dentistry. 5. Temporomandibular Disorder 6. Orthodontics. 7. Prosthodontics 8. Oral and maxillofacial surgery.
![Page 31: Chairman : Dr.Hung -Chi Yang Presenter : Ping-Yang Liao Adviser : Dr. Yi-Chun Du](https://reader033.vdocuments.pub/reader033/viewer/2022061413/5681671f550346895ddba082/html5/thumbnails/31.jpg)
Improrperly restored tooth can cause several problem like
* Headache * TMD related problem * Fracture of tooth / restoration * Save time of finishing of restoration.
![Page 32: Chairman : Dr.Hung -Chi Yang Presenter : Ping-Yang Liao Adviser : Dr. Yi-Chun Du](https://reader033.vdocuments.pub/reader033/viewer/2022061413/5681671f550346895ddba082/html5/thumbnails/32.jpg)
References• http://www.tekscan.com/ Tekscan• http://www.bioresearchinc.com/ Bio researchinc• http://www.specialtydentist.com/t-scan.html Specialty Dentist• http://www.vectordiagnostics.com/ Vector Diagnostics• http://bvdl.com/blog/ BVDL• http://www.awotek.com/ Awotek• http://www.slideshare.net/ Slideshare
![Page 33: Chairman : Dr.Hung -Chi Yang Presenter : Ping-Yang Liao Adviser : Dr. Yi-Chun Du](https://reader033.vdocuments.pub/reader033/viewer/2022061413/5681671f550346895ddba082/html5/thumbnails/33.jpg)
Thanks for your attention