chassis ds gersis

Upload: juan-carlos-mamani-mariaca

Post on 13-Apr-2018

216 views

Category:

Documents


0 download

TRANSCRIPT

  • 7/27/2019 Chassis Ds Gersis

    1/11

    1-slot or 4-slot Chassis

    Raisecom Technology Co., Ltd.

    RC001-1-DC Chassis

    Slot Number RC001/RC002-4 has 4 slots;

    RC001-1 has one slot.

    Power Supply AC: 100~240V, 50/60Hz;

    DC: -72~-36V DC

    WP: 100~240V AC or -72~-36V DC (the WP power supply connector

    will adapt to the factual power supply automatically)

    Power Protection overcurrent protection, short circuit protection

    Network management RC002-4 is a chassis with in-built SNMP agent module. The SNMP

    agent module enables the network managment over service modules in

    RC002-4 and their peer devices.

    In small-capacity situation, Raisecom presents

    its 4-slot chassis RC001-4, 4-slot network

    manageable chassis RC002-4 and single-slot chassis RC001-1 to meet customer

    requirements of installing and/or managing

    different service modules, including media

    converter, fber optic modem, PDH multiplexer,

    interface converter, G.SHDSL modem and

    CWDM cards, concentratedly on one platform.

    RC001-4 and RC002-4 have identical structure

    and dimension.The only difference is that

    RC002-4 has an in-built SNMP agent module,

    and through which the four service modules

    in RC002-4 can be network managed.

    Fixed in RC001-1 series single-slot chassis,Raisecom's modular devices become stand-

    alone equipments, and can be either placed

    on table or mounted on wall or rack with

    accessories. The employment of power supply

    connector of RC001-1 depends on customer's

    need. Except for traditional connector for AC

    or DC power supply, an option of connector

    for wide-range power supply is provided.

    Feature

    RC001/RC002-4 Chassis

    Compliance

    Standards UL,CE,FCC, CSAcomplied with IP30

    SpecifcationDimension RC001/002-4:

    440x44x266mm (WxHxD)

    RC001-1:158x40x200mm (WxHxD)

    Power

    Consumption

    RC001/002-4:40W

    RC001-1:10W

    Working

    Temperature

    0~45 degree Celsius

    Relative Humidity 5%~95%

    Storing

    ambience

    -40~70 degree Celsius

    Ordering InformationRC001-1-AC 1U, 1-slot chassis, with AC power supply connector

    RC001-1-DC 1U, 1-slot chassis, with DC power supply connector

    RC001-1-WP 1U, 1-slot chassis, with WP wide-range power supply connector that adapts

    to the factual power supply (AC or DC) automatically

    RC001-1 Rack-

    Mount Tray

    Accessory for installing RC001-1 chassis on 19" rack, two RC001-1 can be

    placed on one tray.

    RC001-1 Rack-

    Mount Angle

    Accessory for installing RC001-1 chassis on 19" rack, one RC001-1 uses

    two rack-mount angles

    RC001-1 Wall-

    Mount Angle

    Accessory for installing RC001-1 chassis on wall, one RC001-1 users two

    wall-mount angles

    RC001-4-AC 1U, 4-slot chassis, with AC power supply connector

    RC001-4-DC 1U, 4-slot chassis, with DC power supply connector

    RC002-4-AC 1U, 4-slot chassis with in-built SNMP management agent and AC power

    supply connector

    RC002-4-DC 1U, 4-slot chassis with in-built SNMP management agent and DC power

    supply connector

    Datasheet

    RC001-1-AC/WP Chassis

    Bossestasse 9,06484 Quedlinburg,Deutschland

    Andreas GeroldTel.: + 49(0) 3946 - 91 99 90Fax: + 49(0) 3946 - 91 99 91Mobil: + 49(0) 171 - 74 262 76E-mail: [email protected]

    Michael LitvinkoTel.: + 375 17 259 11 03Fax: + 375 17 259 11 18Mobil: + 375 297 600 103E-mail: [email protected]

    www.sis-group.com

  • 7/27/2019 Chassis Ds Gersis

    2/11

    RC001-1D single-slot chassis

    Raisecom Technology Co., Ltd.

    RC001-1D Front Panel

    Power Supply

    Connector

    AC power supply connector for AC power supply

    or DC power supply connector for DC power supplyor WP power supply connector adapted to the factual power

    supply (AC or DC) automaticallyPower Protection overcurrent protectionSlot Number 1 slot, with the width of 2 slot of RC002-16

    RC001-1D is a single-slot chassis designed

    for service modules that take up 2 slots in

    RC002-16. It is applicable for telecom carrierand important enterprise user in the feld of

    fnance, electric power, petroleum industry, and

    etc. To provide high service capacity, some of

    Raisecom's modular devices, including Ethernet

    to 4/8E1 interface converters, PDH multiplexers

    providing 4/8 E1 channels, and multi-service

    multiplexers providing 4/8/16 plus 1 Ethernet

    service, occupies 2 slots in RC002-16 . Fixed

    in RC001-1D, these modular devices become

    stand-alone equipments, and can be eitherplaced on table or mounted on wall or rack with

    accessories. The employment of power supply

    connector depends on user's need. Except

    for traditional connector for AC or DC power

    supply, an option of connector for wide-range

    power supply is provided.

    Feature

    Datasheet

    Compliance

    Ordering Information

    Standards CE and UL

    SpecifcationsDimension 158x64x200mm(WxHxD)

    Power Supply AC 100~240V, 50/60Hz

    DC -36V~-72V

    Power

    Consumption

    less than or equal to 15W

    Working

    Temperature

    -5~55 degree Celsius

    Humidity 5%~95%

    Storing

    Temperature

    -40~70 degree Celsius

    Application

    RC001-1D-AC single-slot chassis, with a connector for AC power supplyRC001-1D-DC single-slot chassis, with a connector for DC power supplyRC001-1D-WP single-slot chassis, with a connector automatically adapted to

    the factual power supply (AC or DC)Rack-Mount Tray accessory for fxing RC001-1D on to 19-inch rackRack-Mount Angle accessory for fxing RC001-1D on to 19-inch rackWall-Mount Angle accessory for mounting RC001-1D on wall

    Service Modules in RC001-1D

    Ethernet to E1 Interface Converters

    RC954-FE(FX)4E1, RC954-2FE4E1-BL,

    RC954-2FE8E1-BLPDH Multiplexer

    RC832-120L, RC832-240L(-BL)

    Multi-Service PDH Multiplexer

    RCMS2802-120LFE(-BL), RCMS2802-

    240LFE(-BL), RCMS2802-120LGE(-BL),

    RCMS2802-240LGE(-BL)

    Bossestasse 9,06484 Quedlinburg,Deutschland

    Andreas GeroldTel.: + 49(0) 3946 - 91 99 90Fax: + 49(0) 3946 - 91 99 91Mobil: + 49(0) 171 - 74 262 76E-mail: [email protected]

    Michael LitvinkoTel.: + 375 17 259 11 03Fax: + 375 17 259 11 18Mobil: + 375 297 600 103E-mail: [email protected]

    www.sis-group.com

  • 7/27/2019 Chassis Ds Gersis

    3/11

    RC001-1M single-slot network-manageable chassis

    Raisecom Technology Co., Ltd.

    RC001-1M Front Panel

    Power Supply AC power supply, or DC power supply, or both AC and DC

    power supplyPower Protection overcurrent protection, short circuit protection, overheat

    protectionSlot Number 1 slotInterfaceType 1 SNMP interface for network management

    1 CONSOLE interface for initial confguration of SNMPNetwrok

    Managementnetwork management over the service module in the RC001-

    1M and the device on the opposite side of the communication

    RC001-1M is a single-slot chassis with in-built

    SNMP management module. It is designed for

    telecom carrier and important enterprise user

    in the feld of fnance, electric power, petroleum

    industry, and etc. Fixed in RC001-1M, modular

    media converters, PDH multiplexers, interface

    converters, G.SHDSL modems and other

    modules designed for 1U slots become stand-

    alone and network-manageable equipments.

    The SNMP agent module built in RC001-1M

    realizes network management function like

    confguration management, diagnostics, loop

    activation, monitoring and fault management.There is one console port, one Ethernet port

    and one slot for modular device on the front

    panel. The AC and DC power supply connectors

    on the rear panel of RC001-1M provides users

    with the fexibility of using AC power supply, or

    DC power supply or both of them.

    Feature

    Datasheet

    RC001-1M Rear Panel

    Compliance

    Ordering InformationRC001-1M single-slot chassis, with inbuilt SNMP network management

    agent module, 1 AC and 1 DC power supply connector

    Standards CE and UL

    SpecifcationsDimension 260x38x190mm(WxHxD)

    Power Supply AC 100~240V,0.35A,50/60Hz

    DC -48V,0.6A

    Power

    Consumption

    less than or equal to 15W

    Working

    Temperature

    0~45 degree Celsius

    Humidity 5%~95%

    Storing

    Temperature

    -40~70 degree Celsius

    Application

    Service modules working and managed in RC001-1M

    RC1~RC6 series media converters

    RC8xx series PDH multiplexers providing 1/2/4 E1 channels or 1 DS1 channel or

    1 DS3/E3 channel

    Multi-service PDH multiplexer RCMS2x01 series and RCMS2802-60GE-BL

    RC9xx series Ethernet to E1, Ethernet to DS3/E3, Ethernet to V.35, V.35 to E1

    interface converters

    OPCOM200 series CWDM modular equipmentsRC1102 series G.SHDSL modem

    Bossestasse 9,06484 Quedlinburg,Deutschland

    Andreas GeroldTel.: + 49(0) 3946 - 91 99 90Fax: + 49(0) 3946 - 91 99 91

    Mobil: + 49(0) 171 - 74 262 76E-mail: [email protected]

    Michael LitvinkoTel.: + 375 17 259 11 03Fax: + 375 17 259 11 18Mobil: + 375 297 600 103E-mail: [email protected]

    www.sis-group.com

  • 7/27/2019 Chassis Ds Gersis

    4/11

    RC001-2M dual-slot network-manageable chassis

    Raisecom Technology Co., Ltd.

    RC001-2M Front Panel

    Power Supply Single AC power supply, or single DC power supply, or both

    AC and DC power supply with two individual connectors or a

    auto-sensing connectorPower Protection overcurrent protection, short circuit protection, overheat

    protectionSlot Number 2 slotsInterfaceType 1 SNMP interface for network management

    1 CONSOLE interface for initial confguration of SNMPNetwrok

    Managementnetwork management over the service module in the RC001-

    2M and the device on the opposite side of the communication

    RC001-2M is a dual-slot chassis with in-built

    SNMP management module. It is designed for

    telecom carrier and important enterprise user

    in the feld of fnance, electric power, petroleum

    industry, and etc. Fixed in RC001-2M, modular

    media converters, PDH multiplexers, interface

    converters, G.SHDSL modems and other

    modules that take up 2 slots in RC002-16

    become stand-alone and network-manageable

    equipments.The SNMP agent module built

    in RC001-2M realizes network management

    function like confguration management,

    diagnostics, loop activation, monitoring and

    fault management. There is one console port,one Ethernet port and two slots for two units

    of individual single-slot width modular device

    or one unit of 2-slot width modular device on

    the front panel. The AC and DC power supply

    connectors on the rear panel of RC001-2M

    provides users with the fexibility of using AC

    power supply, or DC power supply or both of

    them.

    Feature

    Datasheet

    RC001-2M Rear Panel

    Compliance

    Ordering InformationRC001-2M-AC/DC Dual-slot chassis, with in-built SNMP network management

    agent module, 1 AC and 1 DC power supply connecters

    RC001-2M-WP Dual-slot chassis, with in-built SNMP network managementagent module, 1 AC/DC auto-sensing power supply connecter

    RC001-2M-AC Dual-slot chassis, with in-built SNMP network management

    agent module, AC power supplyRC001-2M-DC Dual-slot chassis, with in-built SNMP network management

    agent module, DC power supply

    Standards CE and UL

    SpecifcationsDimension 320x65x200mm(WxHxD)

    Power Supply AC 100~240V,0.35A,50/60Hz

    DC -48V,0.6A

    Power

    Consumption

    less than or equal to 15W

    Working

    Temperature

    0~45 degree Celsius

    Humidity 5%~95%

    Storing

    Temperature

    -40~70 degree Celsius

    Preliminary

    Bossestasse 9,06484 Quedlinburg,Deutschland

    Andreas GeroldTel.: + 49(0) 3946 - 91 99 90Fax: + 49(0) 3946 - 91 99 91Mobil: + 49(0) 171 - 74 262 76E-mail: [email protected]

    Michael LitvinkoTel.: + 375 17 259 11 03Fax: + 375 17 259 11 18Mobil: + 375 297 600 103E-mail: [email protected]

    www.sis-group.com

  • 7/27/2019 Chassis Ds Gersis

    5/11

    RC001-2M dual-slot network-manageable chassis

    Raisecom Technology Co., Ltd.

    Datasheet

    Typical Application

    Dual-slot-width service modules working and managed in RC001-2M (02/2008)RC8xx series PDH multiplexers

    RCMS series Multi-service PDH multiplexers

    RC9xx series Ethernet over PDH(E1s) inverse multiplexers

    One-slot-width service modules working and managed in RC001-2M (02/2008)

    RC1xx~RC6xx series media converters

    RC8xx series PDH modem and multiplexers

    RCMS series Multi-service PDH multiplexers

    RC9xx series Ethernet over E1(s), Ethernet over DS3/E3, Ethernet over V.35, V.35 to E1 interfaceconverters and inverse multiplexers

    OPCOM200 series CWDM modular equipments

    RC1102 series G.SHDSL modems

    Warning: The total power consumption of the 2 one-slot-width service modules working in

    RC001-2M must not exceed 12W.

    Preliminary

    Bossestasse 9,06484 Quedlinburg,Deutschland

    Andreas GeroldTel.: + 49(0) 3946 - 91 99 90Fax: + 49(0) 3946 - 91 99 91Mobil: + 49(0) 171 - 74 262 76E-mail: [email protected]

    Michael LitvinkoTel.: + 375 17 259 11 03Fax: + 375 17 259 11 18Mobil: + 375 297 600 103E-mail: [email protected]

    www.sis-group.com

  • 7/27/2019 Chassis Ds Gersis

    6/11

    RC002-16 16-slot Chassis with SNMP Management

    Raisecom Technology Co., Ltd.

    RC002-16

    Slot Number Up to 16 slots for modular converters

    Redundant Power

    Supply

    Two rear-loading, redundant, load-sharing, hot-swappable AC or DC or one

    AC and one DC power supplies

    Hot-wappable

    power supply

    RC002-16 can operate with single or dual AC or DC power supplies.

    Each power supply supports a full rack of any combination of cards.

    The redundant power supply can be replaced without affecting system

    performance

    Flexibility Single chassis for various modular converters with a variety of technologies,

    rates, interfaces and media

    Hot-swappable

    modular converters

    All cards are hot-swappable and can be replaced without interfering with the

    data transmission of other cards

    Safety Compliance CE and UL

    Effcient Heat

    dissipation

    Optimal structure for effcient heat dissipation

    Network

    Management

    The chassis can be managed by Raisecom network management platform

    Nview iEMS (graphic format), which allowing confguration management,

    diagnostics and loop activation, as well as monitoring and fault management

    Real-time

    confguration and

    monitoring

    The management software enables the user to change the setup

    confguration, get real-time alerts on system status, activate diagnostics, and

    receive statistics on system functionality in a graphic format.

    Number of slot 16

    Power supply Two hot-swappable AC or DC

    power supplies

    Input power

    supply voltage

    AC: 185V-265V, 50/60Hz

    DC: -36V- -72V

    Rated Current 20A

    Short CurrentProtection

    Yes

    Over Current

    Protection

    30A

    Noise 100mVp-p

    Port

    specifcation

    (For NMS1

    network

    management

    card)

    CONSOLE: RJ-45

    ETH (for SNMP and Telnet):

    RJ-45

    Cascading port: RJ45

    Indicators PWR: for power supply

    PS1-5: PS1 for modulesPS1-12: PS1 for 1st fan

    PS2-5: PS2 for modules

    PS2-12: PS2 for 2nd fan

    Dimension 442x130.5x350mm (WxHxD)

    Power

    consumption

    80W (at max load)

    Working

    ambience

    Temp: 0~50 degree Celsius

    RH: 5~90% non-condensing

    Storage

    ambience

    Temp: -40~85 degree Celsius

    RH: 20~90% non-condensing

    Safety

    compliance

    CE marking

    UL

    RC002-16 is a 19" rack-mountable 3U platform

    which supports two rear-loading, redundant,

    load-sharing, hot-swappable AC or DC power

    supplies. Up to 16 modular converters can be

    installed in the chassis, providing a CO/POP

    site solution for connecting up to 16 remote

    users (15 with SNMP function).

    RC002-16 is manageable access system for

    providing full convergence of the Last Mile

    with a variety of technologies, rates, interfaces

    and media. The system supports standard

    technologies G.703/704, G.SHDSL and

    IEEE802.3. Each card in the RC002-16 works in

    a point-to-point confguration opposite a remote

    unit with no connection to the adjacent cards.

    This allows each card to support a different

    rate, interface or media.All cards are hot-wappable and can be replaced

    without interfering with the data transmission of

    other cards.

    RC002-16 supports SNMP management with

    NMS1 card inserted. The network management

    software iEMS enables the user to change

    the setup confguration, get real-time alerts on

    system status, active diagnostics, and receive

    statistics on system functionality in a graphic

    format.

    Specifcation

    Feature

    Ordering InformationRC001-NMS1 Network management master module for RC series modules, installed into

    3U 16-slot chassis

    RC001-NMS2 Network management slave module for RC series modules, installed into 3U

    16-slot chassis

    RC002-16AC/S 3U, 16-slot chassis with one AC power supply connector

    RC002-16AC/D 3U, 16-slot chassis with two AC power supply connector

    RC002-16DC/S 3U, 16-slot chassis with one DC power supply connector

    RC002-16DC/D 3U, 16-slot chassis with two DC power supply connector

    RC009-2AC Redundant AC power supply for RC002-16

    RC009-2DC Redundant DC power supply for RC002-16

    Mount Angle 21 Accessory for installing RC002-16 on 21" rack, two angles for one chassis

    Mount Angle 23 Accessory for installing RC002-16 on 23" rack, two angles for one chassisNote: The RC002-16 chassis can be installed on 19" rack directly without any accessory.

    Datasheet

    RC001-NMS1

    Bossestasse 9,06484 Quedlinburg,Deutschland

    Andreas GeroldTel.: + 49(0) 3946 - 91 99 90Fax: + 49(0) 3946 - 91 99 91Mobil: + 49(0) 171 - 74 262 76E-mail: [email protected]

    Michael LitvinkoTel.: + 375 17 259 11 03Fax: + 375 17 259 11 18Mobil: + 375 297 600 103E-mail: [email protected]

    www.sis-group.com

  • 7/27/2019 Chassis Ds Gersis

    7/11

    Raisecom Technology Co., Ltd.

    RC002 Cascade

    With management agent master

    module RC001-NMS1 and

    slave module RC001-NMS2

    connecting in the manner shown

    on the right, four RC002-16chassis forms a cascade.

    At most sixty pairs of

    equipments at both local and

    remote sites can be managed

    through one IP address which

    is the IP address of RC001-

    NMS1.

    Typical Application

    Bossestasse 9,06484 Quedlinburg,Deutschland

    Andreas GeroldTel.: + 49(0) 3946 - 91 99 90Fax: + 49(0) 3946 - 91 99 91Mobil: + 49(0) 171 - 74 262 76E-mail: [email protected]

    Michael LitvinkoTel.: + 375 17 259 11 03Fax: + 375 17 259 11 18Mobil: + 375 297 600 103E-mail: [email protected]

    www.sis-group.com

  • 7/27/2019 Chassis Ds Gersis

    8/11

    RC004-16 Chassis for PDH FOM Modular Devices

    Raisecom Technology Co., Ltd.

    RC004-16 16-slot Chassis

    with SNMP Management

    RC004-16 is a 19" rack mountable 10U

    16-slot chassis for Raisecom modular type

    Fiber Optical Modem (4E1, 8E1, 16E1and 8E1+4ETH) and it has rear-loading,

    redundant, load-sharing,hot-swappable AC or

    DC power supply. Each card in the RC004-16

    works in a point-to-point mode with a remote

    unit and so as to provide a CO/POP site

    solution for Fiber Optical Modem users. All

    cards are hot-swappable and can be replaced

    without interferring with the data transmission

    of other cards. RC004-16 supports SNMP

    network management with RC004-16NMS1

    card inserted in slot 0, and along with theRC004-16NMS2 card cascade can be realized

    up to 4 RC004-16 chassis. The network

    management software NNM enables users to

    change the setup confguration, get real-time

    alerts on system status, active diagnostics,

    and receive statistics on system functionality

    in a graphic format.

    Feature

    Datasheet

    Slot Number Up 16 slots for modular converters

    Redundant Power

    Supply

    Two rear-loading, redundant, load-sharing, hot-swappable AC or DC or one

    AC and one DC power supplies

    Hot-wappable

    power supply

    RC004-16 can operate with single or dual AC or DC power supplies.

    Each power supply supports a full rack of any combination of cards.

    The redundant power supply can be replaced without affecting system

    performance

    Flexibility Single chassis for various modular converters with a variety of technologies,

    rates, interfaces and media

    Hot-swappable

    modular converters

    All cards are hot-swappable and can be replaced without interfering with the

    data transmission of other cards

    High Reliability NEBS Compliant

    Safety Compliance CE and UL

    Effcient Heat

    dissipation

    Optimal structure for effcient heat dissipation

    Power supply Two hot-swappable AC or DC

    power supplies

    Input power

    supply voltage

    AC: 185V-265V, 50/60Hz

    DC: -36V- -72VShort Current

    Protection

    Yes

    Dimension 436(W)*440(H)*360(D)mm

    Power

    consumption

    150W (at max load)

    Working

    ambience

    Temp: 0~50 centigrade

    RH: 5~90% non-condensing

    Storage

    ambience

    Temp: -40~85 centigrade

    RH: 20~90% non-condensing

    Specifcation

    Compliance

    Standard UL

    Ordering InformationRC004-16NMS1 Master agent module for network management, installed in slot 0 of

    RC004-16 chassis

    RC004-16NMS2 Cascade module for network management, installed in slot 0 of RC004-16

    chassis

    RC004-16AC 10U, 16-slot chassis with one AC power supply

    (can provide redundant power supply)

    RC004-16DC 10U, 16-slot chassis with one DC power supply

    (can provide redundant power supply)

    RC007-2AC Redundant power supply for RC004-16 chassis, ACRC007-2DC Redundant power supply for RC004-16 chassis, DC

    Mount Angle 19

    Center

    Accessory for installing RC004-16 chassis on 19" center mounted rack

    Note: RC004-16 chassis can be directly installed on normal front mounted

    19" rack and need no additioinal mount angle.

    Mount Angle 21

    Center

    Accessory for installing RC004-16 chassis on 21" center mounted rack

    RC004-16NMS1

    Management Agent Module

    RC004-16NMS2

    Management Cascade

    Module

    Bossestasse 9,06484 Quedlinburg,Deutschland

    Andreas GeroldTel.: + 49(0) 3946 - 91 99 90Fax: + 49(0) 3946 - 91 99 91Mobil: + 49(0) 171 - 74 262 76E-mail: [email protected]

    Michael LitvinkoTel.: + 375 17 259 11 03Fax: + 375 17 259 11 18Mobil: + 375 297 600 103E-mail: [email protected]

    www.sis-group.com

  • 7/27/2019 Chassis Ds Gersis

    9/11

    RC006-1 Series single-slot chassis

    Raisecom Technology Co., Ltd.

    Construction Single-slot, 19 inch, 1Unit highPower Supply Single AC, or single DC, or AC/DC redundant power supplies

    RC006-1 non-management chassis

    RC006-1M SNMP interface for management, Console interface for SNMP initial

    confguration.

    In support of management over service modules in the chassis and

    remote devices

    In support of online upgrade

    Features

    Ordering InformationRC006-1-X single-slot chassis for modules in RC006-12

    RC006-1M-X single-slot chassis for modules in RC006-12, SNMP managementXindicates the optical port specifcation:

    AC: 220V/230VAC power supply;

    DC: -48VDC power supply;

    AC/DC: AC and DC redundant power supply

    Raisecom modem pool RC006-12 could

    feed high speed and legacy data service,

    leased line service and backhauling of mobile

    BTS and connectivity WiMAX CPE of MetroEthernet simultaneously. It could hybrid support

    for multiple levels PDH products including

    E1 extension PDH fber optical multiplexer,

    PCM multiplexer, Ethernet over PDH Inverse

    Multiplexer. All of the module in central offce

    Datasheet

    RC006-1, RC006-1M

    modem pool RC006-12 could be deployed in

    remote site with single-slot chassis RC006-1

    as well to enable customer to save cost for

    inventory. Raisecom also offers the single-slotchassis with SNMP & console ports RC006-1M

    for single module application in central offce.

    SpecifcationConsole port RS-232 standard

    RJ-45

    9600bps

    SNMP port 10/100Mbps

    FDX/HDX

    Auto-negotiation

    IEEE802.3x fow control

    Auto-MDI/MDIX

    Dimensions 430(W)*44.45(H)*266mm(D)

    Power Supply 180VAC~260VAC

    -36VDC~-72VDC

    +12VDC~+36VDCPower

    Consumption

  • 7/27/2019 Chassis Ds Gersis

    10/11

    RC006-12 12 service slots multi-service modem pool

    Raisecom Technology Co., Ltd.

    RC006-12 12 service slots

    multi-service modem pool

    Slot Number 15 slots, 12 slots for service cards, 2 slots for power supply modules and 1

    slot for network management card

    Redundant Power

    Supply

    Two front-loading, redundant, load-sharing, hot-swappable dual AC or dual

    DC or one AC and one DC power supply

    Hot-wappable

    power supply

    RC006-12 can operate with single or dual AC or DC power supplies.

    Each power supply supports a full rack of any combination of cards.

    The redundant power supply can be replaced without affecting system

    performanceFlexibility Single chassis for various modular cards with a variety of technologies,

    rates, interfaces and media, unifed SNMP management for all the modules

    Hot-swappable

    modular converters

    All cards are hot-swappable and can be replaced without interfering with the

    data transmission of other cards

    Safety Compliance CE and UL

    Effcient Heat

    dissipation

    Optimal structure for effcient heat dissipation

    Network

    Management

    The chassis can be managed by Raisecom network management platform

    Nview iEMS (GUI), which allowing confguration management, diagnostics

    and loop activation, as well as monitoring and fault management

    Real-time

    confguration andmonitoring

    The management software enables the user to change the setup

    confguration, get real-time alerts on system status, activate diagnostics, andreceive statistics on system functionality in a graphic format.

    Number of slot 15

    12 slots for service cards

    2 slots for power supply

    modules

    1 slot for network

    management card

    Power supply Two hot-swappable AC or DCpower supplies

    Input power

    supply voltage

    AC: 85V-265V, 50/60Hz

    DC: -36V- -72V

    Rated Current 20A

    Short Current

    Protection

    Yes

    Over Current

    Protection

    Yes

    Noise 100mVp-p

    Port

    specifcation

    (For NMS1network

    management

    card)

    CONSOLE: RJ-45

    ETH (for SNMP and Telnet):

    RJ-45

    Net Weight 4.6kg (with two power

    supplies)

    Dimension 442(W)*248(H)*267(D)mm

    Power

    consumption

    300W (at max load)

    Working

    ambience

    Temp: -5~50 centigrade

    RH: 5~90% non-condensing

    Storage

    ambience

    Temp: -40~85 centigrade

    RH: 20~90% non-condensing

    RC006-12 is a ETSI complied 19" rack-

    mountable 6U high platform which supports

    two front-loading, redundant, load-sharing,

    hot-swappable AC or DC power supplies. Up

    to 12 modular service cards and one network

    management card can be installed in the

    chassis, providing a CO/POP site solution for

    connecting up to 12 remote CPE.

    RC006-12 multi-service modem pool feeds

    simultaneously high speed and legacy data

    service, analog voice service, leased line

    service and backhauling of Mobile BTS and

    connectivity WiMAX CPE to Metro Ethernet.

    It could hybrid support for multiple level PDH

    products such as: cost effective E1 extension

    PDH product up to 16E1; PCM multiplexer

    s analog voice and legacy data service for

    enterprise customers; carrier grade multi-service PDH product with up to 16 E1s

    (including 1*V.35) and 1*10/100M Ethernet

    interface.

    Redundant fber optic links and power supply

    could guarantee the maximum networking

    uptime. Switching over time from primary

    fber link to secondary is less than 50ms. This

    platform could supply SNMP management,

    TELNET, and local craft terminal management

    through RS232 interface. Full range of

    management makes carrier to easily operate

    and monitor local and remote device anywhere.

    SpecifcationFeature

    Ordering InformationRC006-12-NMS Network management module for RC006-12 chassis

    RC006-12AC/S 6U, 12 service slots chassis with one 115V or 230V AC power supply

    RC006-12AC/D 6U, 12 service slots chassis with two 115V or 230V AC power supplies

    RC006-12DC/S 6U, 12 service slots chassis with one -48V DC power supply

    RC006-12DC/D 6U, 12 service slots chassis with two -48V DC power supplies

    Bossestasse 9,06484 Quedlinburg,Deutschland

    Andreas GeroldTel.: + 49(0) 3946 - 91 99 90Fax: + 49(0) 3946 - 91 99 91Mobil: + 49(0) 171 - 74 262 76E-mail: [email protected]

    Michael LitvinkoTel.: + 375 17 259 11 03Fax: + 375 17 259 11 18Mobil: + 375 297 600 103E-mail: [email protected]

    www.sis-group.com

  • 7/27/2019 Chassis Ds Gersis

    11/11

    Raisecom Technology Co., Ltd.

    Typical Applicatioin

    Bossestasse 9,06484 Quedlinburg Deutschland

    Andreas GeroldTel.: + 49(0) 3946 - 91 99 90Fax: + 49(0) 3946 - 91 99 91Mobil: + 49(0) 171 - 74 262 76E mail: andreas gerold@gersis eu

    Michael LitvinkoTel.: + 375 17 259 11 03Fax: + 375 17 259 11 18Mobil: + 375 297 600 103E mail: mikhail litvinko@gersis eu