    Circulating Water System

    This presentation is designed to provide you the information you need to

    understand and operate the Circulating Water System. You should view

    all slides and read and study the information presented.

    The presentation slides are advanced by clicking on the

    button.

    You can also advance to a selected section by using the topic buttons..

    Industrial Resources, Inc.

    Big Cajun Power Plant

  • 8/14/2019 Circ Water System Vo

    2/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    In this module we will:

    Describe the function of the Circulating Water System.

    Describe the flow paths and major components associated withthe Circulating Water System.

    Describe the Circulating Water System process control loops and

    associated methods of control.

    Describe the steps required to prepare for and startup theCirculating Water System.

    Describe the steps taken during normal operation of theCirculating Water System.

    Describe the steps required to shut down the Circulating WaterSystem.

  • 8/14/2019 Circ Water System Vo

    3/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Circulating Water System Function

  • 8/14/2019 Circ Water System Vo

    4/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    The Circulating Water System Condenses Low

    Pressure Turbine Exhaust Steam.

    Main Steam

    Cold Reheat

    Steam

    Hot Reheat

    Steam

    LP Turbine

    Exhaust

    Condenser

    CirculatingWater Inlet

    Circulating

    Water Outlet

    Condensate PumpHotwell

  • 8/14/2019 Circ Water System Vo

    5/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Cooling Tower

  • 8/14/2019 Circ Water System Vo

    6/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Flow Path

    Cooling

    Tower

    Basin

    Circ Water Pump

    Condenser

  • 8/14/2019 Circ Water System Vo

    7/89Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Circulating Water System

    Flow Path

  • 8/14/2019 Circ Water System Vo

    8/89Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Cooling Tower

  • 8/14/2019 Circ Water System Vo

    9/89Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Circulating Water System Data

  • 8/14/2019 Circ Water System Vo

    10/89Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Review QuestionsWhat is the function of the Circulating Water System?

    What process is used to realease the heat from the

    Circulating water in the Cooling Tower?

    How is the Circulating Water cooled as it flows

    through the Cooling Tower?

    Click to Review

    Click to Review

    Click to Review

    When you are sure you can correctly answer these question

    click the Button to continue

  • 8/14/2019 Circ Water System Vo

    11/89Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Major Components

    Circulating Water Pumps

    Cooling Tower

    Condenser

  • 8/14/2019 Circ Water System Vo

    12/89Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Circulating Water Pumps

  • 8/14/2019 Circ Water System Vo

    13/89Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Circulating Water Pumps

  • 8/14/2019 Circ Water System Vo

    14/89Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Circulating Water Pumps Valves

  • 8/14/2019 Circ Water System Vo

    15/89Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Circulating Water Pumps Data

  • 8/14/2019 Circ Water System Vo

    16/89Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Condenser

    Circ Water

    InletCirc Water

    OutletTube

    Sheet

    Tubes

    Hotwell

    Outlet

    Waterbox

    Inlet

    Waterbox

    Waterbox

    Vent

    LP HeaterExtractionPiping

  • 8/14/2019 Circ Water System Vo

    17/89Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Condenser Waterbox Valves

  • 8/14/2019 Circ Water System Vo

    18/89Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Condenser Data

    Circ Water Inlet

    Temperatures

    Circ Water Inlet

    Temperatures

    DP Indication

    Condenser

    Backpressure

  • 8/14/2019 Circ Water System Vo

    19/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Cooling Tower

    Cells

    Risers

  • 8/14/2019 Circ Water System Vo

    20/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Cooling Tower

  • 8/14/2019 Circ Water System Vo

    21/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Cooling Tower Fans

    Risers

    Bypass

    Intake Screen

    Cooling Tower Fans

  • 8/14/2019 Circ Water System Vo

    22/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Cooling Tower Basin

    Bypass

    Makeup

    Screen

  • 8/14/2019 Circ Water System Vo

    23/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Cooling Tower Data

  • 8/14/2019 Circ Water System Vo

    24/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Cooling Tower Fans Data

  • 8/14/2019 Circ Water System Vo

    25/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Review Questions

    Click to Review

    What is the function of the

    Circulating Water Pumps?

    Which Circulating Water System Valve,

    when open, allows a single Circulating

    Water Pump to supply both condenser

    sides?

    What component mounted in the

    channel between the stop gate and the

    intake structure prevents debris from

    entering the pump suction?

    When you are sure you can correctly answer these question

    click the Button to continue

    Click to Review

    Click to Review

  • 8/14/2019 Circ Water System Vo

    26/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Component Controls

    Circulating Water Pump Controls

    Cooling Tower Bypass Valve Controls

    Cooling Tower Fans Automatic Controls

  • 8/14/2019 Circ Water System Vo

    27/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Circulating Water Pump

    Suction Valve Controls

    A

    BA

    B

  • 8/14/2019 Circ Water System Vo

    28/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Circulating Water Pump

    Discharge Valve Controls

    A

    B

  • 8/14/2019 Circ Water System Vo

    29/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Pump Cooling Water Supply

  • 8/14/2019 Circ Water System Vo

    30/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Circulating Water Pump

    Start/Stop Controls

    Start/Stop

    Soft Keys

  • 8/14/2019 Circ Water System Vo

    31/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Pump Permits and

    Process Trips

  • 8/14/2019 Circ Water System Vo

    32/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Pump Lockout/Tagout

    Lockout

    Tagout

  • 8/14/2019 Circ Water System Vo

    33/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Circulating Water Pump

    Discharge Valve Controls

  • 8/14/2019 Circ Water System Vo

    34/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Cooling Tower Controls

  • 8/14/2019 Circ Water System Vo

    35/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Cooling Tower

    Bypass Valve Control

    Bypass Valve

  • 8/14/2019 Circ Water System Vo

    36/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Cooling Tower

    Bypass Valve Control

  • 8/14/2019 Circ Water System Vo

    37/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Cooling Tower Fan Controls

  • 8/14/2019 Circ Water System Vo

    38/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Fan Remote Start/Stop Controls

  • 8/14/2019 Circ Water System Vo

    39/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    De-icing Control

  • 8/14/2019 Circ Water System Vo

    40/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Review Questions

    How is each Circulating Water Pump

    motor operated suction valve typically

    controlled?

    How is each Circulating Water Pumpmotor operated discharge valve typically

    controlled?

    How is De-icing of the Cooling Tower

    performed?

    Click to Review

    Click to Review

    Click to Review

    When you are sure you can correctly answer these question

    click the Button to continue

  • 8/14/2019 Circ Water System Vo

    41/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Process Control

  • 8/14/2019 Circ Water System Vo

    42/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Cooling Tower

    Makeup Valve Control

    Make

    up

    Valve

    Basin Level

    Level Controller

  • 8/14/2019 Circ Water System Vo

    43/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Cooling Tower Basin Level

    Controller

    A in the grey background

    indicates that the level

    setpoint is not in automatic.

    L in a white background

    indicates that the operator

    has local control over the

    Basin Level setpoint.

    Brown arrows indicate

    basin level upper and lower

    limits.

    Level Setpoint

    Measured Flow

    Valve Output

    percent

  • 8/14/2019 Circ Water System Vo

    44/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Auto/Manual Control

    A in the grey background

    indicates that the level

    setpoint is not in automatic.

    L in a white background

    indicates that the operator

    has local control over the

    Basin Level setpoint.

    Brown arrows indicate

    upper and lower Basin

    Level limits.

    Level Setpoint

    Measured Flow

    Valve Output

    percent

  • 8/14/2019 Circ Water System Vo

    45/89

    Basin Level Setpoint

    A in the grey background

    indicates that the level

    setpoint is not in automatic.

    L in a white background

    indicates that the operator

    has local control over the

    Basin Level setpoint.

    Brown arrows indicate

    upper and lower valve

    output limits.

    Level Setpoint

    Measured Flow

    Valve Output

    percent

  • 8/14/2019 Circ Water System Vo

    46/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Review QuestionsHow is the Cooling Tower Makeup Valveactuated and controlled?

    What does the Cooling Tower Makeup

    Valve Controller Output Control?

    Where does the Cooling Tower Basin Level

    setpoint come from?

    When you are sure you can correctly answer these question

    click the Button to continue

    Click to Review

    Click to Review

    Click to Review

  • 8/14/2019 Circ Water System Vo

    47/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Circulating Water System

    Operation Startup Prerequisites

    System Startup Normal Operation

    System Shutdown

  • 8/14/2019 Circ Water System Vo

    48/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Startup Prerequisites

    CIRCULATING WATER SYSTEM

  • 8/14/2019 Circ Water System Vo

    49/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    CIRCULATING WATER SYSTEM

    STARTUP

    Ensure Basin Level is established and

    maintained

    Ensure Circulating Water Pumps areready for Startup

    Ensure system valves are properly aligned

    Ensure support systems are available forservice.

  • 8/14/2019 Circ Water System Vo

    50/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Prepare the Cooling Tower

  • 8/14/2019 Circ Water System Vo

    51/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Establish Basin Level

    Make

    up

    Valve

    Basin Level

    Level Controller

  • 8/14/2019 Circ Water System Vo

    52/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Circulating Water Pump

    Rack in pump andvalve breakers

    OPEN each pumpssuction valve

    Verify motor bearingoil levels are ok.

    Valve in instrument

    air and cooling water. CLOSE the circulating

    water cross-tie Circulating Water Pumps

  • 8/14/2019 Circ Water System Vo

    53/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Cooling Tower Fans

  • 8/14/2019 Circ Water System Vo

    54/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Align System Valves

    Suction

    Valves

    Waterbox

    Inlet

    Valves

    Waterbox

    Outlet

    Valves

    Discharge Cross-tie

    Valve

  • 8/14/2019 Circ Water System Vo

    55/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Open the Cooling Tower Bypass

    START the A circ lating ater

  • 8/14/2019 Circ Water System Vo

    56/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    START the A circulating water

    pump

    M

    A

  • 8/14/2019 Circ Water System Vo

    57/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Check Pump Data

  • 8/14/2019 Circ Water System Vo

    58/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    A

  • 8/14/2019 Circ Water System Vo

    59/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Close the Cooling Tower Bypass

  • 8/14/2019 Circ Water System Vo

    60/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Start Cooling Tower Fans

    At 50 Percent Load prepare for

  • 8/14/2019 Circ Water System Vo

    61/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    At 50 Percent Load, prepare for

    and start the 2ndCirc Water Pump

    A

    M

    M

    M

    Cross-tie

    Valve

    B

    M

  • 8/14/2019 Circ Water System Vo

    62/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Re-open the Discharge Cross-tie

    A

    M

    M

    M

    B

    M

    MCross-tie Valve

  • 8/14/2019 Circ Water System Vo

    63/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    NORMAL OPERATION

    Monitor Circulating Water System

  • 8/14/2019 Circ Water System Vo

    64/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Monitor Circulating Water System

    process variables from DCS displays.

  • 8/14/2019 Circ Water System Vo

    65/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Check Cooling Tower Fans

  • 8/14/2019 Circ Water System Vo

    66/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    De-ice Cooling Tower If Required

  • 8/14/2019 Circ Water System Vo

    67/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Circulating Water Pumps

  • 8/14/2019 Circ Water System Vo

    68/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    SHUT DOWN

  • 8/14/2019 Circ Water System Vo

    69/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Shut Down One Circ. Pump

    M

    M

    M

    M

    A

    Cross-tie

    Valve

    B

    M

    Select the Cooling Tower Fan

  • 8/14/2019 Circ Water System Vo

    70/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Select the Cooling Tower Fan

    Stop Auto Sequence

    OPEN the

  • 8/14/2019 Circ Water System Vo

    71/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    OPEN the

    Cooling Tower Bypass Valve

    STOP the Operating Circulating

  • 8/14/2019 Circ Water System Vo

    72/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    STOP the Operating Circulating

    Water Pump

    M

    M

    M

    M

    M

    A

    Cross-tie

    Valve

    B

  • 8/14/2019 Circ Water System Vo

    73/89

  • 8/14/2019 Circ Water System Vo

    74/89

    Exit ProgramMajor Components Component Controls Process Control System OperationSystem Function

    Review QuestionsDuring preparation for Circulating Water

    System Startup, what are the four majorsteps involved?

    What position must the Circ. Water

    Discharge Cross-tie valve be in prior to

    starting the 2ndCirculating Water Pump?

    During Normal Operation, how is ice removed

    from the Cooling Tower?

    When you are sure you can correctly answer these question

    click the Button to continue

    Click to Review

    Click to Review

    Click to Review

  • 8/14/2019 Circ Water System Vo

    75/89

  • 8/14/2019 Circ Water System Vo

    76/89

    Cooling Tower

    Return to

    Review Questions

  • 8/14/2019 Circ Water System Vo

    77/89

    Cooling Tower

    Return to

    Review Questions

    C

  • 8/14/2019 Circ Water System Vo

    78/89

    Circulating Water Pumps

    Return to

    Review Questions

    Ci l i W P V l

  • 8/14/2019 Circ Water System Vo

    79/89

    Circulating Water Pumps Valves

    Return to

    Review Questions

    C li T B i

  • 8/14/2019 Circ Water System Vo

    80/89

    Cooling Tower Basin

    Bypass

    Makeup

    ScreenReturn to

    Review Questions

    Circulating Water Pump

  • 8/14/2019 Circ Water System Vo

    81/89

    Circulating Water Pump

    Suction Valve Controls

    A

    BA

    B

    Return to

    Review Questions

    Circulating Water Pump

  • 8/14/2019 Circ Water System Vo

    82/89

    Circulating Water Pump

    Discharge Valve Controls

    A

    B

    Return to

    Review Questions

    D i i C t l

  • 8/14/2019 Circ Water System Vo

    83/89

    De-icing Control

    Return to

    Review Questions

    Cooling Tower

  • 8/14/2019 Circ Water System Vo

    84/89

    Cooling Tower

    Makeup Valve Control

    Make

    up

    Valve

    Basin Level

    Level Controller

    Return to

    Review Questions

    Cooling Tower

  • 8/14/2019 Circ Water System Vo

    85/89

    Cooling Tower

    Makeup Valve Control

    Make

    up

    Valve

    Basin Level

    Level Controller

    Return to

    Review Questions

    B i L l S t i t

  • 8/14/2019 Circ Water System Vo

    86/89

    Basin Level Setpoint

    A in the grey background

    indicates that the level

    setpoint is not in automatic.

    L in a white background

    indicates that the operator

    has local control over the

    Basin Level setpoint.

    Brown arrows indicate

    upper and lower valve

    output limits.

    Level Setpoint

    Measured Flow

    Valve Output

    percent

    Return to

    Review Questions

    CIRCULATING WATER SYSTEM

  • 8/14/2019 Circ Water System Vo

    87/89

    CIRCULATING WATER SYSTEM

    STARTUP

    Ensure Basin Level is established and

    maintained

    Ensure Circulating Water Pumps areready for Startup

    Ensure system valves are properly aligned

    Ensure support systems are available forservice.

    Return to

    Review Questions

    Ci l ti W t P

  • 8/14/2019 Circ Water System Vo

    88/89

    Circulating Water Pump

    Rack in pump andvalve breakers

    OPEN each pumpssuction valve

    Verify motor bearingoil levels are ok.

    Valve in instrumentair and cooling water.

    CLOSE the circulatingwater cross-tie Circulating Water Pumps

    Return to

    Review Questions

    D i C li T If R i d

  • 8/14/2019 Circ Water System Vo

    89/89

    De-ice Cooling Tower If Required