Unit with hermetic scroll type compressor and propeller fans  TERMINAL U NIT GEOTHER MIC CLOSECONTROL Unit with hermetic scroll type compressor and propeller fans Cooling capacity [1] Cooling capacity [1] Heating capacity [2] Shipping weight Sound pressu re level [3] No. & Type of Compressors No. & Type of fans - External Secti on Fans Dimensions Cooling capacity [1] Cooling capacity [1] Heating capacity [2] Shipping weight Sound press ure level [3] No. & Type of fans - External Secti on Fans No. & Type of Compressors Dimensions 20 ,7 25 ,7 28, 1 33, 9 37, 6 43 ,5 52 ,7 56 ,9 6 3,0 7 8,3 9 3,5 10 1, 5119, 1131, 6140, 3151, 1 35 ,0 40 ,6 44,2 52,1 56,4 61,2 77,8 90,9 10 4, 4 11 9, 2 13 2, 0 14 1, 1148,1 4 0, 9 47 ,1 5 2, 3 60,2 66,2 72,3 8 6, 7 10 0, 9 115, 4 12 9, 8 14 8, 0 15 5,8166,4 220 275 280 380 400 485 580 585 590 1347 1473 1548 1666 1695 1746 1789 60 59 59 60 60 60 60 60 60 72 74 75 77 77 77 77 2 Scroll 3 Scrol l 4 Scroll 1 Axi al 2 Axial 4 Axial 6 Axial 2 Axial 3 Axial 1435 1530 1530 1563 1563 1563 2098 2098 2098 3250 3250 3250 3250 32 50 32 50 32 50 67 8 67 8 67 8 11 07 11 07 11 07 11 07 11 07 11 07 10 95 10 95 10 95 10 95 10 95 10 95 10 95 1000 1530 1530 1570 1570 1570 1570 1570 1570 2030 2030 2030 2030 2030 20 30 20 30 4,4 5,6 6,8 8,0 10,0 12,0 14,4 16,0 18,6 21,3 26,5 31,3 4,7 5,8 7,1 8,2 10,2 11,7 14,6 16,1 19,6 21,9 27,4 33,1 5,5 6,9 8,2 9,7 12,0 14,2 17,1 19,2 23,2 27,6 30,0 36,2 94 94 102 102 136 136 182 182 175 215 270 275 53 55 55 56 58 60 60 60 60 61 60 61 1 Scroll 1 Axial 2 Axial 1 Axial 2 Axial 895 895 895 895 1040 1040 1325 1325 1435 1435 1530 1530 359 359 359 359 411 411 555 555 678 678 678 678 895 895 1095 1095 1175 1175 1225 1225 1000 1000 1530 1530 Regulation a series o f units insta lled to ope rate in the same circuit communicate with each other to optimise the management of the various components. Remote control management a perso nal comp uter can be used to manage all the functions of the unit and display all the operating parameters.  This allows preventive remote service and the diagnosis of any malfunctions.  Air cooled water chiller for outdoor installation    8    2   ÷    6    0    4 WSAT  Air to water heat pump for outdoor installation WSAN  ® WSAT - WSAN 82 102 122 142 162 182 202 222 242 292 323 404 464 524 564 604 data refer to the following conditions: [1] evaporator water = 12/7°C; room temperature = 35°C; [2] evaporator air intake = 6.1°C WB; condenser water outlet temperature 45°C; [3] The sound levels refer to the unit at full load, in the rated test conditions. The sound pressure level refers to a distance of 1m from the external surface of the units operating in an open field. Ready to install the unit doe s not requi re an external hydronic assembly, as it is already fitted as standard with a pump. Setting Logic in systems with widel y varyin g loads, the reduced load phases are managed intelligently so as to minimise energy consumption. Possible Configurations Unit for production of chilled water to -8°C Partial recovery of condensing heat, up to 25%  Total condensing heat recovery Built-in free-cooling system Standard B D R FC S 11      H      Y      D      R      O      N      I      C Sizes DIVISION   R407C R22 CLIVET is an active member of the EUROVENT certification program. Wsat R407C Wsan R22 Wsan R22 Length Depth Height kW kW kW Kg dB(A) mm mm mm CLIVET is an active member of the EUROVENT certification program. Can be installed anywhere the comp act over all dime nsions, together with the minimum functional clearances, make it extremely easy to find the right location. qui et operat ion. constru ction mat erials wit h excellen t weather resistance. WSAN WSAT  Air to water heat pump for outdoor installation  Air cooled water chiller for outdoor installation  ® data refer to the following conditions: [1] evaporator water = 12/7°C; room temperature = 35°C; [2] evaporator air intake = 6.1°C WB; condenser water outlet temperature 45°C; [3] The sound levels refer to the unit at full load, in the rated test conditions. The sound pressure level refers to a distance of 1m from the external surface of the units operating in an open field. 10 Everything you need from a chiller integr ated fros t prevent ion systems . high energy ef ficien cy: abov e average COP. Time is precious unit read y for opera tion, only re quire s the water and electrical connections. manag ement of t he pump s and stora ge tanks in the unit. hydro nic assembly and sto rage integrated into the unit. Possible Configurations Operation with chilled fluid, outlet temperature to -7°C Possibility of automatic set point modification Serial communication module to interface with the most modern supervisor systems DIVISION      1    7   ÷    1    2    1      H      Y      D      R      O      N      I      C R407C R22 HYDRONIC SPLIT SYSTEM PACKAGED WSAT - WSAN 17 21 25 31 41 51 61 71 81 91 101 121 Wsat R407C Wsan R22 Wsan R22 Length Depth Height kW kW kW Kg dB(A) mm mm mm Sizes Low speed axial fan directly couple d by electrical motor Hermetic compressor Scroll type Tandem Compressors Scroll type Braze welded plate exchanger ST LN Configuration: Standard Low noise

Upload: sean-thomas

Post on 19-Feb-2018

259 views

Category:

Documents


1 download

TRANSCRIPT

7/23/2019 Clivet Toplotne Pumpe

http://slidepdf.com/reader/full/clivet-toplotne-pumpe 1/15

Unit with hermetic scroll type compressor andpropeller fans

 TERMINAL U NIT  GEOTHERMIC CLOSECONTROL

Unit with hermetic scroll type compressor andpropeller fans

Cooling capacity [1]

Cooling capacity [1]

Heating capacity [2]

Shipping weight

Sound pressure level [3]

No. & Type of Compressors

No. & Type of fans - External Secti on Fans

Dimensions

Cooling capacity [1]

Cooling capacity [1]

Heating capacity [2]

Shipping weight

Sound pressure level [3]

No. & Type of fans - External Secti on Fans

No. & Type of Compressors

Dimensions

2 0, 7 2 5, 7 28 ,1 33 ,9 37 ,6 4 3, 5 5 2, 7 5 6,9 6 3,0 7 8,3 9 3,5 1 01 ,5 1 19 ,1 1 31 ,6 1 40 ,3 1 51 ,1

35, 0 40, 6 44, 2 52, 1 56, 4 61, 2 77, 8 90, 9 104,4 119,2 132,0 141,1148, 1

40, 9 47, 1 52, 3 60, 2 66, 2 72, 3 86, 7 100,9 115,4 129,8 148,0 155,8166, 4

220 275 280 380 400 485 580 585 590 1347 1473 1548 1666 1695 1746 1789

60 59 59 60 60 60 60 60 60 72 74 75 77 77 77 77

2 Scroll 3 Scroll 4 Scroll

1 Axial 2 Axial 4 Axial 6 Axial 2 Axial 3 Axial

1435 1530 1530 1563 1563 1563 2098 2098 2098 3250 3250 3250 3250 3250 3250 3250

6 78 6 78 6 78 1 10 7 1 10 7 1 10 7 1 10 7 1 10 7 1 10 7 1 09 5 1 09 5 1 095 1 095 1 09 5 1 09 5 1 09 5

1000 1530 1530 1570 1570 1570 1570 1570 1570 2030 2030 2030 2030 2030 2030 2030

4,4 5,6 6,8 8,0 10,0 12,0 14,4 16,0 18,6 21,3 26,5 31,3

4,7 5,8 7,1 8,2 10,2 11,7 14,6 16,1 19,6 21,9 27,4 33,1

5,5 6,9 8,2 9,7 12,0 14,2 17,1 19,2 23,2 27,6 30,0 36,2

94 94 102 102 136 136 182 182 175 215 270 275

53 55 55 56 58 60 60 60 60 61 60 61

1 Scroll

1 Axial 2 Axial 1 Axial 2 Axial

895 895 895 895 1040 1040 1325 1325 1435 1435 1530 1530

359 359 359 359 411 411 555 555 678 678 678 678

895 895 1095 1095 1175 1175 1225 1225 1000 1000 1530 1530

Regulation

• a series of units installed to operate in

the same circuit communicate with

each other to optimise the management

of the various components.

Remote control management

• a personal computer can be used to

manage all the functions of the unit and

display all the operating parameters.

 This allows preventive remote service

and the diagnosis of any malfunctions.

 Air cooled water chiller for

outdoor installation

   8   2  ÷   6   0   4

WSAT Air to water heat pump for

outdoor installation

WSAN

 ® 

WSAT - WSAN82 102 122 142 162 182 202 222 242 292 323 404 464 524 564 604

data refer to the following conditions:[1] evaporator water = 12/7°C; room temperature = 35°C;[2] evaporator air intake = 6.1°C WB; condenser water outlet temperature 45°C;

[3] The sound levels refer to the unit at full load, in the rated test conditions. The sound pressure level refers to adistance of 1m from the external surface of the units operating in an open field.

Ready to install

• the unit does not require an external

hydronic assembly, as it is already fitted

as standard with a pump.

Setting Logic

• in systems with widely varying loads,

the reduced load phases are managed

intelligently so as to minimise energy

consumption.

Possible Configurations

Unit for production of chilled water to

-8°C

Partial recovery of condensing heat,

up to 25%

 Total condensing heat recovery

Built-in free-cooling system

Standard

B

D

R

FC

S

11

     H     Y     D     R     O     N     I     C

Sizes

DIVISION   

R407C

R22

CLIVET is an active member of the

EUROVENT certification program.

Wsat R407C

Wsan R22

Wsan R22

Length

Depth

Height

kW

kW

kW

Kg

dB(A)

mm

mm

mm

CLIVET is an active member of the

EUROVENT certification program.

Can be installed anywhere

• the compact overall dimensions,

together with the minimum functional

clearances, make it extremely easy to

find the right location.

• quiet operation.

• construction materials with excellent

weather resistance.

WSANWSAT Air to water heat pump for

outdoor installation

 Air cooled water chiller for

outdoor installation

 ® 

data refer to the following conditions:[1] evaporator water = 12/7°C; room temperature = 35°C;[2] evaporator air intake = 6.1°C WB; condenser water outlet temperature 45°C;

[3] The sound levels refer to the unit at full load, in the rated test conditions. The sound pressure levelrefers to a distance of 1m from the external surface of the units operating in an open field.10

Everything you need from a chiller

• integrated frost prevention systems.

• high energy efficiency: above average

COP.

Time is precious

• unit ready for operation, only requires

the water and electrical connections.

• management of the pumps and storage

tanks in the unit.

• hydronic assembly and storage

integrated into the unit.

Possible Configurations

Operation with chilled fluid, outlet

temperature to -7°C

Possibility of automatic set point

modification

Serial communication module to interface

with the most modern supervisor systems

DIVISION   

   1   7  ÷   1   2   1

     H     Y     D     R     O     N     I     C

R407C

R22

HYDRONIC SPLIT SYSTEM PACKAGED

WSAT - WSAN 17 21 25 31 41 51 61 71 81 91 101 121

Wsat R407C

Wsan R22

Wsan R22

Length

Depth

Height

kW

kW

kW

Kg

dB(A)

mm

mm

mm

Sizes

Low speed axial fan

directly coupled byelectrical motor

Hermetic compressor

Scroll type

Tandem Compressors

Scroll type

Braze welded plate

exchanger

ST

LN

Configuration:

Standard

Low noise

7/23/2019 Clivet Toplotne Pumpe

http://slidepdf.com/reader/full/clivet-toplotne-pumpe 2/15

Unit with semi-hermetic screw compressor andpropeller fans

 TERMINAL U NIT  GEOTHERMIC CLOSECONTROL

Unit with semi-hermetic screw compressorand propeller fans

Cooling capacity [1]

Shipping weight

Sound pressure level [3]

No. & Type of Compressors

No. & Type of fans - External Secti on Fans

Dimensions

810,6 855,1 912,7 963,1 1013,61064,0 1112,91181,0 1234,81285,4 1334,71383,9 1482,3

6705 7046 7327 7762 8631 8800 8969 10175 10586 10765 10929 11096 11272

85 85 85 85 86 86 86 87 87 87 87 87 87

3 Single Screw 4 Single Screw

16 Axial 17 Axial 18 Axial 23  Axial 24 Axial

7918 7918 8938 8938 9840 9840 9840 11790 11790 11790 11790 11790 11790

2326 2326 2326 2326 2326 2326 2326 2326 2326 2326 2326 2326 2326

2443 2443 2443 2443 2443 2443 2443 2443 2443 2443 2443 2443 2443

Control Logic

• analyses the thermal requirements of the

system, optimising the compressor starts

and stops.

Regulation

• the sophisticated electronics used control

not only of the normal unit operating

parameters, but also the environmental

conditions, thus activating the defrosts

only when strictly required. This allows

more regular operation and significant

energy savings.

 Air cooled water chiller for

outdoor installation

   3 .   3   9   0  ÷   4 .   7   2   0

WSAT

 ® 

WSAT3.390 3.410 3.430 3.450 3.480 3.510 3.540 4.580 4.600 4.630 4.660 4.690 4.720

data refer to the following conditions[1] evaporator water = 12/7°C; room temperature = 35°C;

[2] the sound levels refer to the unit at full load, in the rated test conditions. The sound pressure level refers to adistance of 1m from the external surface of the units operating in an open field.

Energy saving

• part or all of the normally-lost condensing

energy can be recovered, for the

production of hot water for a variety of 

uses.

• continuous and instant optimisation of 

fan operation for maximum energy

savings.

Possible Configurations

Unit for production of chilled

water to -8°C

Partial recovery of condensing

heat, up to 15%

 Total condensing heat recovery

Built-in free-cooling system

Standard

B

D

R

FC

S

13

     H     Y     D     R     O     N     I     C

Sizes

DIVISION   

R407C

R22

CLIVET is an active member of the

EUROVENT certification program.

Wsat R407C

Length

Depth

Height

kW

Kg

dB(A)

mm

mm

mm

CLIVET is an active member of the

EUROVENT certification program.

• outside air heat exchangers with

innovative shape, especially designed to

guarantee maximum efficiency and

continuity over time.

Time is precious

• the careful design allows the unit to be

handled, positioned and connected on

site with extreme simplicity.

WSANWSAT Air to water heat pump for

outdoor installation

 Air cooled water chiller for

outdoor installation

 ® 

data refer to the following conditions:[1] evaporator water = 12/7°C; room temperature = 35°C;[2] evaporator air intake = 6.1°C WB; condenser water outlet temperature 45°C;

[3] The sound levels refer to the unit at full load, in the rated test conditions. The sound pressure levelrefers to a distance of 1m from the external surface of the units operating in an open field.12

Suitable for any kind of installation

• for renovations and all cases where

space is limited, the compact

dimensions of the unit simplify

installation.

• for installations in particularly aggressive

environments, the air-side exchangers

can be made using special materials or

coatings that increase resistance to

corrosive agents.

High efficiency 

• uprated heat exchangers can be

requested in the event of high outside

temperatures or to increase energy

efficiency in all conditions.

Possible Configurations

Unit for production of chilled

water to -8°C

Partial recovery of condensing

heat, up to 15%

 Total condensing heat recovery

Built-in free-cooling system

Standard

DIVISION   

   2 .   9   0  ÷   2 .   3   6   0

     H     Y     D     R     O     N     I     C

R407C

R22

Single screw compressor

with satellites

Microprocessor control

panel

S ingle s crew compre ss or Bra ze we lded plate

exchanger

HYDRONIC SPLIT SYSTEM PACKAGED

Cooling capacity [1]

Cooling capacity [1]

Heating capacity [2]

Shipping weight

Sound pressure level [3]

No. & Type of Compressors

No. & Type of fans - External Secti on Fans

Dimensions

194,2 237,0 260,7 277,0 297,4 339,5 367,2 416,3 482,5 538,2 592,1 642,7 691,9 741,1

205,2 237,6 260,9 291,7 320,5 353,2 379,6 438,8

284,2 324,1 362,6 397,4 429,9 467,1 501,1 570,3

2706 2941 3166 3250 3295 3595 3681 3891 4315 4491 5070 5539 5689 5840

81 81 82 82 82 82 83 83 83 83 84 84 84 84

2 Single Screw

4 Axial 5 Axial 6 Axial 7 Axial 8 Axial 9 Axial 10 Axial 11 Axial 12 Axial

3950 3950 3950 3950 3950 3950 3950 3950 4880 4880 5900 5900 5900 5900

2040 2040 2040 2040 2040 2326 2326 2326 2326 2326 2326 2326 2326 2326

2104 2104 2104 2104 2104 2443 2443 2443 2443 2443 2443 2443 2443 2443

WSAT - WSAN

Wsat R407C

Wsan R22

Wsan R22

Length

Depth

Height

kW

kW

kW

Kg

dB(A)

mm

mm

mm

Sizes

B

D

R

FC

S

2 .9 0 2 .10 0 2 .1 10 2 .1 25 2. 14 0 2 .1 55 2 .17 0 2. 20 0 2 .2 30 2 .2 60 2 .2 80 2 .30 0 2. 33 0 2 .3 60

ST

SC

LN

EN

Configuration:

Standard

Sound-proof compressorenclosures

Low noise

Extremely low noise

ST

SC

LN

EN

Configuration:

Standard

Sound-proof compressorenclosures

Low noise

Extremely low noise

7/23/2019 Clivet Toplotne Pumpe

http://slidepdf.com/reader/full/clivet-toplotne-pumpe 3/15

Unit with semi-hermetic screw compressor andpropeller fans

 TERMINAL U NIT  GEOTHERMIC CLOSECONTROL

Unit with semi-hermetic screw compressor andpropeller fans

Cooling capacity [1]

Shipping weight

Sound pressure level [2]

No. & Type of Compressors

No. & Type of fans - External Secti on Fans

Dimensions

206,5 240,3 273,4 298,5 321,8 381,3 436,1 461,9 491,8

2920 3170 3336 3446 3562 4239 4638 4749 5019

79 79 80 81 81 82 82 82 82

2 Single Screw

4 Axial 5 Axial 6 Axial 7 Axial 8 Axial

3950 3950 3950 3950 3950 4880 4880 4880 4880

2040 2040 2040 2040 2040 2326 2326 2326 2326

2104 2104 2104 2104 2104 2443 2443 2443 2443

Cooling capacity [1]

Shipping weight

Sound pressure level [2]

No. & Type of Compressors

No. & Type of fans - External Secti on Fans

Dimensions

541,5 593,7 619,2 688,7 715,0 741,2 817,4 872,2 898,0 927,9 953,7 983,6

6485 6875 7255 7526 7645 7765 9307 9705 9816 10086 10197 10467

83 83 84 84 84 84 85 85 85 85 85 85

3 Single Screw 4 Single Screw

12 Axial 13 Axial 14 Axial 15 Axial 16 Axial

7918 7918 7918 7918 7918 7918 9750 9750 9750 9750 9750 9750

2326 2326 2326 2326 2326 2326 2326 2326 2326 2326 2326 2326

2443 2443 2443 2443 2443 2443 2443 2443 2443 2443 2443 2443

Low noise Level

• wherever silent operation is required, the

units can be configured for reduced

noise emissions and transmission of 

vibrations to the support structures.

Control Logic

• the unit dynamically modulates the

temperature of the chilled fluid according

to the outside temperature, thus

optimising energy efficiency.

Can be installed anywhere

• the special structure with base made

from thick galvanised steel plate section

bars ensures uniform weight distribution.

 Air cooled water chiller for

outdoor installation

   3 .   2   6   0  ÷   4 .   4   8   0

WSAT

 ® 

WSAT3.260 3.280 3.300 3.320 3.340 3.360 4.380 4.400 4.420 4.440 4.460 4.480

data refer to the following conditions[1] evaporator water = 12/7°C; room temperature = 35°C;

[2] the sound levels refer to the unit at full load, in the rated test conditions. The sound pressure level refersto a distance of 1m from the external surface of the units operating in an open field.

High efficiency 

• outside air heat exchangers with

innovative shape, especially designed to

guarantee maximum efficiency and

continuity over time.

Energy saving

• part or all of the normally-lost

condensing energy can be recovered,

for the production of hot water for a

variety of uses.

Possible Configurations

unit for production of chilled

water to -8°C

partial recovery of condensing

heat, up to 15%

total condensing heat recovery

built-in free-cooling system

standard

B

D

R

FC

S

15

     H     Y     D     R     O     N     I     C

Sizes

DIVISION   

R134a

CLIVET is an active member of the

EUROVENT certification program.

Wsat R134a

Length

Depth

Height

kW

Kg

dB(A)

mm

mm

mm

CLIVET is an active member of the

EUROVENT certification program.

Energy savings

• in systems with widely varying loads,

the reduced load phases are managed

intelligently so as to minimise energy

consumption.

Maximum respect for the environment

• with the ecological refrigerant the unit

complies with the strictest pollution

control and environmental protection

standards.

WSAT Air cooled water chiller for

outdoor installation

 ® 

data refer to the following conditions[1] evaporator water = 12/7°C; room temperature = 35°C;

[2] the sound levels refer to the unit at full load, in the rated test conditions. The sound pressure level refersto a distance of 1m from the external surface of the units operating in an open field.14

Control logic

• a series of units installed to operate in

the same circuit communicate with

each other to optimise the management

of the various components.

Suitable for any kind of installation

• for renovations and all cases where

space is limited, the compact

dimensions of the unit simplify

installation.

Reliability and build quality 

• guaranteed quality of all the

components installed.

DIVISION   

   2 .   9   0  ÷   2 .   2   4   0

     H     Y     D     R     O     N     I     C

R134a

HYDRONIC SPLIT SYSTEM PACKAGED

WSAT 2.90 2.110 2.130 2.145 2.160 2.180 2.200 2.220 2.240

Wsat R134a

Length

Depth

Height

kW

Kg

dB(A)

mm

mm

mm

Sizes

Possible Configurations

unit for production of chilled

water to -8°C

partial recovery of condensing

heat, up to 15%

total condensing heat recovery

built-in free-cooling system

standard

 Axial fan with profiled

blades

Microprocessor control

panel

Single screw compressor

with satellites

B

D

R

FC

S

Shell and tube heat

exchanger

ST

SC

LN

EN

Configuration:

Standard

Sound-proof compressorenclosures

Low noise

Extremely low noise

ST

SC

LN

EN

Configuration:

Standard

Sound-proof compressorenclosures

Low noise

Extremely low noise

7/23/2019 Clivet Toplotne Pumpe

http://slidepdf.com/reader/full/clivet-toplotne-pumpe 4/15

Unit with semi-hermetic reciprocating compressorand propeller fans

 TERMINAL U NIT  GEOTHERMIC CLOSECONTROL

Unit with semi-hermetic double screw compressorand propeller fans

Cooling capacity [1]

Shipping weight

Sound pressure level [3]

No. & Type of Compressors

No. & Type of fans - External Secti on Fans

Dimensions

299,4 319,9 338,1 361,9 382,8 422,6 485,6 510,7 535,8 574,9 613,9

3402 3509 3603 3645 3658 4319 5001 5104 5202 5470 5577

82 83 84

2 Double Screw

6 Axial 7 Axial 8 Axial 10 Axial 12 Axial

3950 3950 3950 3950 3950 3950 4880 4880 4880 5900 5900

2040 2040 2040 2040 2040 2326 2326 2326 2326 2326 2326

2104 2104 2104 2104 2104 2443 2443 2443 2443 2443 2443

Cooling capacity [1]

Cooling capacity [1]

Heating capacity [2]

Shipping weight

Sound pressure level [3]

No. & Type of Compressors

No. & Type of fans - External Section Fans

Dimensions

Wrat and Wran R22 up to size 2.120

High efficiency 

• uprated heat exchangers can be

requested in the event of high outside

temperatures or to increase energy

efficiency in all conditions.

Suitable for any kind of installation

• for renovations and all cases where

space is limited, the compact

dimensions of the unit simplify

installation.

 Air cooled water chiller for

outdoor installation

   2 .   7   0  ÷   2 .   1   4   0

WRAT Air to water heat pump for

outdoor installation

WRAN

 ® 

WRAN - WRAT

data refer to the following conditions[1] evaporator water = 12/7°C; room temperature = 35°C;[2] evaporator air intake = 10°C WB (R.H. = 80%); condenser water outlet temperature 40/45°C;

[3] the sound levels refer to the unit at full load, in the rated test conditions. The sound pressure level refersto a distance of 1m from the external surface of the units operating in an open field.

Regulation

• a series of units installed to operate in

the same circuit communicate with

each other to optimise the management

of the various components.

Control logic

• in systems with widely varying loads,

the reduced load phases are managed

intelligently so as to minimise energy

consumption.

Possible Configurations

Unit for production of chilled

water to -8°C

Partial recovery of condensing

heat, up to 25%

 Total condensing heat recovery

Built-in free-cooling system

Standard

B

D

R

FC

S

17

     H     Y     D     R     O     N     I     C

Sizes

DIVISION   

R407C

R22

CLIVET is an active member of the

EUROVENT certification program.

Wrat R407C

Wrat R22

Wran R22

Length

Depth

Height

kW

kW

kW

Kg

dB(A)

mm

mm

mm

CLIVET is an active member of the

EUROVENT certification program.

Reliability and build quality 

• twin-screw compressor for maximum

sturdiness and reliability over time.

• the use of plate exchangers, specifically

designed for use with ecological gas and

with perfectly opposing flows, optimises

the heat exchange of the water on the

utility side.

WDAT Air cooled water chiller for

outdoor installation

 ® 

data refer to the following conditions[1] evaporator water = 12/7°C; room temperature = 35°C;

[2] the sound levels refer to the unit at full load, in the rated test conditions. The sound pressure level refersto a distance of 1m from the external surface of the units operating in an open field.16

Control Logic

• analyses the thermal requirements of the

system, optimising the compressor

starts and stops.Remote control management

• a personal computer can be used to

manage all the functions of the unit and

display all the operating parameters.

 This allows preventive remote service

and the diagnosis of any malfunctions.

Can be installed anywhere

• for installations in particularly aggressive

environments, the air-side exchangers

can be made using special materials or

coatings that increase resistance to

corrosive agents.

DIVISION   

   2 .   1   4   0  ÷   2 .   2   8   0

     H     Y     D     R     O     N     I     C

R407C

R22

HYDRONIC SPLIT SYSTEM PACKAGED

WDAT 2.140 2.150 2.160 2.170 2.180 2.200 2.220 2.235 2.250 2.265 2.280

Wdat R407C

Length

Depth

Height

kW

Kg

dB(A)

mm

mm

mm

Sizes

Double screw

compressor rotors

Reciprocating

compressor

Possible Configurations

Unit for production of chilled

water to -8°C

Partial recovery of condensing

heat, up to 15%

 Total condensing heat recovery

Built-in free-cooling system

Standard

B

D

R

FC

S

138,6 154,0 167,2 186,4 202,2 226,4 246,5 272,5 286,8

163,7 179,8 192,5 215,2 234,2 257,0 272,8

202,6 222,9 243,2 272,1 293,2 320,4 347,6

1890 1982 2066 2203 2410 2402 2463 2487 2492

81 83 85

2 Reciprocating

4 Axial

2950 2950 2950 2950 2950 2950 2950 2950 2950

2040 2040 2040 2040 2040 2040 2040 2040 2040

2113 2113 2113 2113 2113 2113 2113 2113 2113

2.70 2.75 2.80 2.90 2.100 2.110 2.120 2.130 2.140

Double screw

compressor rotors

 Axial fan with profiled

blades

ST

SC

LN

EN

Configuration:

Standard

Sound-proof compressorenclosures

Low noise

Extremely low noise

ST

SC

LN

EN

Configuration:

Standard

Sound-proof compressorenclosures

Low noise

Extremely low noise

7/23/2019 Clivet Toplotne Pumpe

http://slidepdf.com/reader/full/clivet-toplotne-pumpe 5/15

Unit with hermetic scroll type compressorand centrifugal fans

 TERMINAL U NIT  GEOTHERMIC CLOSECONTROL

Unit with semi-hermetic reciprocating compressorand propeller fans

Possible Configurations

Unit for production of chilled

water to -8°C

Partial recovery of condensing

heat, up to 15%

 Total condensing heat recovery

Standard

Cooling capacity [1]

Cooling capacity [1]

Heating capacity [2]

Shipping weight

Sound pressure level [3]

No. & Type of Compressors

No. & Type of fans - External Secti on Fans

Dimensions

Everything you need from a chiller

• fan inverter to optimise energy

consumption.

• high energy efficiency: above averageCOP.

Time is precious

• all the static pressure requirements are

satisfied by the use of a wide range of 

motors.

• unit ready for operation, only requires

the water and electrical connections.

• management of the pumps in the unit.

 Air cooled water chiller for

indoor installation

   2   1  ÷   1   2   1

WRA  Air to water heat pump

for indoor installation

WRN

 ® 

WRN - WRA 

data refer to the following conditions[1] evaporator water = 12/7°C; ambient air temperature = 30°C;[2] evaporator air intake = 6.1°C WB; condenser water outlet temperature 45°C;

[3] the sound levels refer to the unit at full load, in the rated test conditions. The sound pressure level refersto a distance of 1m from the external surface of the units operating in an open field.

Can be installed anywhere

• can be installed in ceilings, garages,

service rooms and basements, without

having to modify the existing structures.• fitted for connection to various types of 

ducting.

• soundproofed panelling that guarantees

reduced noise levels.

Possible Configurations

Remote control

Serial communication module to interface

with the most modern supervisor systems

Operation with chilled fluid, outlet

temperature to -7°C

19

     H     Y     D     R     O     N     I     C

Sizes

DIVISION   

R407C

R22

CLIVET is an active member of the

EUROVENT certification program.

Wra R407C

Wrn R22

Wrn R22

Length

Depth

Height

kW

kW

kW

Kg

dB(A)

mm

mm

mm

Cooling capacity [1]

Heating capacity [2]

Shipping weight

Sound pressure level [3]

No. & Type of Compressors

No. & Type of fans - External Secti on Fans

Dimensions

CLIVET is an active member of the

EUROVENT certification program.

Reliability and build quality 

• outside air heat exchangers with

innovative shape, especially designed to

guarantee maximum efficiency andcontinuity over time guaranteed quality of 

all the components installed.

Energy saving

• part or all of the normally-lost condensing

energy can be recovered, for the

production of hot water for a variety of 

uses.

WRANWRAT Air to water heat pump for

outdoor installation

 Air cooled water chiller for

outdoor installation

 ® 

data refer to the following conditions[1] evaporator water = 12/7°C; room temperature = 35°C;[2] evaporator air intake = 10°C WB (R.H. = 80%); condenser water outlet temperature 40/45°C;

[3] the sound levels refer to the unit at full load, in the rated test conditions. The sound pressure level refersto a distance of 1m from the external surface of the units operating in an open field.18

Low noise Level

• wherever silent operation is required,

the units can be configured for

reduced noise emissions andtransmission of vibrations to the

support structures.

Control Logic

• the unit dynamically modulates the

temperature of the chilled fluid

according to the outside temperature,

thus optimising energy efficiency.

Can be installed anywhere

• the special structure with base made

from thick galvanised steel plate

section bars ensures uniform weight

distribution.

DIVISION   

   4 .   1   4   0  ÷   4 .   2   4   0

     H     Y     D     R     O     N     I     C

R22

HYDRONIC SPLIT SYSTEM PACKAGED

WRAT - WRAN

Wrat R22

Wran R22

Length

Depth

Height

kW

kW

Kg

dB(A)

mm

mm

mm

Sizes

Reciprocating compressor

B

D

R

S

321,0 381,6 428,3 473,4 514,0 546,4

405,2 486,4 544,2 586,4 640,8 695,2

3397 3596 3974 4333 4400 4416

86 86 86 86 88 89

4 Reciprocating

8 Axial

5900 5900 5900 5900 5900 5900

2040 2040 2040 2040 2040 2040

2113 2113 2113 2113 2113 2113

4.140 4.160 4.180 4.200 4.220 4.240

 Axial fan with profiledblades

5,7 6,7 7,8 11,8 15,5 21,0 25,0 30,0

5,9 7,1 8,5 12,4 17,2 22,7 26,3 32,1

6,8 8,0 9,4 14,0 19,1 27,0 29,5 35,6

97 123 125 170 329 347 400 420

57 59 60 65 61 60 60 62

1 Scroll

1 Centrifugal

790 935 935 1165 1517 1517 1780 1780

538 630 630 703 758 758 846 846

648 648 648 723 1130 1130 1205 1205

21 25 31 51 71 91 101 121

Fan Inverter to optimise

energy consumption

Hermetic compressor

Scroll type

Shell and tube heat

exchanger

STSC

LN

EN

Configuration:

Standard

Sound-proof compressorenclosures

Low noise

Extremely low noise

7/23/2019 Clivet Toplotne Pumpe

http://slidepdf.com/reader/full/clivet-toplotne-pumpe 6/15

Unit with semi-hermetic reciprocatingcompressor and centrifugal fans

 TERMINAL U NIT  GEOTHERMIC CLOSECONTROL

Unit with hermetic scroll typecompressor and centrifugal fans

Cooling capacity [1]

Shipping weight

Sound pressure level [2]

No. & Type of Compressors

No. & Type of fans - External Secti on Fans

Dimensions

Low noise Level

• wherever silent operation is required,

the units can be configured for reduced

noise emissions and transmission of vibrations to the support structures.

Control Logic

• a series of units installed to operate in

the same circuit communicate with

each other to optimise the management

of the various components.

 Air cooled water chiller for

indoor installation

   2 .   7   0  ÷   2 .   1   2   0

WRA 

 ® 

WRA 

data refer to the following conditions[1] evaporator water = 12/7°C; ambient air temperature = 35°C;

[2] the sound levels refer to the unit at full load, in the rated test conditions. The sound pressure level refersto a distance of 1m from the external surface of the units operating in an open field.

Can be installed anywhere

• the special structure with base made

from thick galvanised steel plate section

bars ensures uniform weight distribution.Reliability and build quality 

• outside air heat exchangers with

innovative shape, especially designed to

guarantee maximum efficiency and

continuity over time.

Possible Configurations

Unit for production of chilled

water to -8°C

Partial recovery of condensing

heat, up to 15%

 Total condensing heat recovery

Standard

B

D

R

S

21

     H     Y     D     R     O     N     I     C

Sizes

DIVISION   

R407C

R22

CLIVET is an active member of the

EUROVENT certification program.

Wra R407C

Length

Depth

Height

kW

Kg

dB(A)

mm

mm

mm

Cooling capacity [1]

Cooling capacity [1]

Heating capacity [2]

Shipping weight

Sound pressure level [3]

No. & Type of Compressors

No. & Type of fans - External Secti on Fans

Dimensions

CLIVET is an active member of the

EUROVENT certification program.

Suitable for any kind of installation

• for renovations and all cases where

space is limited, the compact

dimensions of the unit simplifyinstallation.The wide range of 

motor/drive possibilities makes the unit

easily adaptable to any type of air

discharge ducting.

Time is precious

• the careful design allows the unit to be

handled, positioned and connected on

site with extreme simplicity.

WRNWRA  Air to water heat pump for

indoor installation

 Air cooled water chiller for

indoor installation

 ® 

data refer to the following conditions[1] evaporator water = 12/7°C; ambient air temperature = 35°C;[2] evaporator air intake = 7°C WB (R.H. = 85%); condenser water outlet temperature 40/45°C;

[3] the sound levels refer to the unit at full load, in the rated test conditions. The sound pressure level refersto a distance of 1m from the external surface of the units operating in an open field.20

Control Logic

• analyses the thermal requirements of the

system, optimising the compressor starts

and stops.• the unit dynamically modulates the

temperature of the chilled fluid according

to the outside temperature, thus

optimising energy efficiency.

• in systems with widely varying loads, the

reduced load phases are managed

intelligently so as to minimise energy

consumption.

DIVISION   

   1   4   2  ÷   6   0   4

     H     Y     D     R     O     N     I     C

R407C

R22

HYDRONIC SPLIT SYSTEM PACKAGED

WRA - WRN

Wra R407C

Wrn R22

Wrn R22

Length

Depth

Height

kW

kW

kW

Kg

dB(A)

mm

mm

mm

Sizes

Possible Configurations

Unit for production of chilled

water to -8°C

Partial recovery of condensing

heat, up to 25%

Standard

B

D

S

Reciprocating

compressor

Hermetic compressor

Scroll type

31,0 42,0 50,0 60,0 72,1 81,5 93,5 99,9 109,1 111,4 121,4 137,3 143,6

34,7 45,4 52,0 64,3 75,7 86,6 96,0 110,1 104,8 115,2 124,3 139,3 147,8

38,0 49,0 58,0 68,0 91,4 102,8 116,7 139,5 124,1 139,6 152,6 169,8 182,4

629 670 760 772 920 950 1050 1070 1500 1550 1580 1675 1700

62 60 61 62 59 64 66 66 61 61 61 63 64

2 Scroll 2 Reciprocating 2 Tandem Scroll

1 Centrifugal 2 Centrifugal 3 Centrifugal

2230 2230 2230 2230 2478 2478 2478 2478 3308 3308 3308 3308 3308

978 978 978 978 974 974 974 974 1152 1152 1152 1152 1152

1430 1430 1705 1705 1672 1672 1672 1672 2275 2275 2275 2275 2275

142 182 202 242 292 322 362 422 404 464 524 564 604

140,0 151,2 160,0 186,1 195,1 213,7 226,0

2068 2128 2155 2390 2489 2619 2635

74 75 76 76 77 79 80

2 Reciprocating

4 Centrifugal

4400 4400 4400 4400 4400 4400 4400

1140 1140 1140 1140 1140 1140 1140

2270 2270 2270 2270 2270 2270 2270

2.70 2.75 2.80 2.90 2.100 2.110 2.120

Fan Inverter to optimise

energy consumption

ST

SC

Configuration:

Standard

Sound-proof compressorenclosures

7/23/2019 Clivet Toplotne Pumpe

http://slidepdf.com/reader/full/clivet-toplotne-pumpe 7/15

Unit with hermetic scroll type compressor

 TERMINAL U NIT  GEOTHERMIC CLOSECONTROL

Unit with hermetic scroll type compressor

Cooling capacity [1]

Heating capacity [2]

Shipping weight

Sound pressure level [3]

No. & Type of Compressors

Dimensions

Cooling capacity [1]

Heating capacity [2]

Shipping weight

Sound pressure level [3]

No. & Type of Compressors

Dimensions

Water cooled water chiller

for indoor installation

   1   0   2  ÷   4   2   2

WRHWater to water heat pump

reversible on the refrigerant circuit

for indoor installation

WRHN

 ® 

WRHN - WRH

data refer to the following conditions:[1] evaporator water = 12/7°C; condenser water = 16/30°C;[2] evaporator water = 12/7°C; condenser water outlet temperature 45°C;

[3] the sound levels refer to the unit at full load, in the rated test conditions. The sound pressure level refersto a distance of 1m from the external surface of the units operating in an open field.

Everything you need from a chiller

• high energy efficiency: above average

COP.• management of the pumps and storage

tanks in the unit.

Time is precious

• reversal on the refrigerant circuit = time

saving.

• reversal on the refrigerant circuit = less

components in the water circuit.

Can be installed anywhere

• quiet operation

• the compact overall dimensions,

together with the minimum functional

clearances, make it extremely easy to

find the right location.

Possible Configurations

 Version available with reversal on the water

circuit (WRH-H)

Remote control

Operation with chilled fluid, outlet

temperature to -7°C

Possibility of automatic set point

modification

Serial communication module to interface

with the most modern supervisor systems

23

     H     Y     D     R     O     N     I     C

Sizes

DIVISION   

R407C

R22

CLIVET is an active member of the

EUROVENT certification program.

Wrh R407C

Wrhn R407C

Length

Depth

Height

kW

kW

Kg

dB(A)

mm

mm

mm

5,4 6,7 8,1 9,3 12,0 14,3 17,2 19,0 20,8 24,8 29,2 35,6

6,2 7,8 9,4 10,9 15,6 16,5 19,6 22,0 24,5 29,3 34,1 41,8

86 89 94 96 102 104 107 109 129 129 134 140

49 49 49 49 50 50 50 50 59 59 60 62

1 Scroll

402 402 402 402 402 402 402 402 402 402 402 402

487 487 487 487 602 602 602 602 602 602 602 602

790 790 790 790 790 790 790 790 915 915 915 915

CLIVET is an active member of the

EUROVENT certification program.

• reversal on the refrigerant circuit = less

components in the water circuit.

Can be installed anywhere• can be installed anywhere, such as

simply the under the sink.

• quiet operation.

• the compact overall dimensions, together

with the minimum functional clearances,

make it extremely easy to find the right

location.

WRHNWRHWater to water heat pump

reversible on the refrigerant circuit

for indoor installation

Water cooled water chiller

for indoor installation

 ® 

data refer to the following conditions:[1] evaporator water = 12/7°C; condenser water = 16/30°C;[2] evaporator water = 12/7°C; condenser water outlet temperature 45°C;

[3] the sound levels refer to the unit at full load, in the rated test conditions. The sound pressure level refersto a distance of 1m from the external surface of the units operating in an open field.22

Everything you need from a chiller

• high energy efficiency: above average

COP.

• management of the pumps and storagetanks in the unit.

• units for geothermal applications.

Time is precious

• water pump and expansion vessel fitted

in version P.

• reversal on the refrigerant circuit = time

savings.

Possible Configurations

 Version available with reversal on the water

circuit (WRH-H)

Operation with chilled fluid, outlet

temperature to -7°C

Possibility of automatic set point

modification

Serial communication module to interface

with the most modern supervisor systems

Remote control

DIVISION   

   1   7  ÷   1   2   1

     H     Y     D     R     O     N     I     C

R407C

R22

HYDRONIC SPLIT SYSTEM PACKAGED

WRH - WRHN 17 21 25 31 41 51 61 71 81 91 101 121

Wrh R407C

Wrhn R407C

Length

Depth

Height

kW

kW

Kg

dB(A)

mm

mm

mm

Sizes

Hermetic compressor

Scroll type

Braze welded plate

exchanger

Electronic

microprocessor control

Hermetic compressor

Scroll type

28,6 38,1 42,3 49,5 58,4 64,8 71,5 93,2 108,0 123,4 148,1

33,0 44,0 48,6 58,6 68,2 75,9 83,7

180 200 248 250 260 266 271 450 490 520 580

53 53 62 62 63 64 65 66 66 66 66

2 Scroll

802 802 802 802 802 802 802 1062 1062 1062 1062

602 602 602 602 602 602 602 580 580 580 580

790 790 915 915 915 915 915 1538 1538 1538 1538

102 142 162 182 202 222 242 292 322 362 422

7/23/2019 Clivet Toplotne Pumpe

http://slidepdf.com/reader/full/clivet-toplotne-pumpe 8/15

Unit with semi-hermetic screw type compressor

 TERMINAL U NIT  GEOTHERMIC CLOSECONTROL

Unit with semi-hermetic screw type compressor

Cooling capacity [1]

Heating capacity [2]

Shipping weight

Sound pressure level [3]

No. & Type of Compressors

Dimensions

Control Logic

• a series of units installed to operate in

the same circuit communicate with

each other to optimise the managementof the various components.

Suitable for any kind of installation

• for renovations and all cases where

space is limited, the compact

dimensions of the unit simplify

installation.

High efficiency 

• new generation water exchangers for

eliminating the heat with solutions

Water cooled water chiller

for indoor installation

   3 .   3   9   0  ÷   4 .   7   2   0

WSHWater to water heat pump

(reversible water circuit) for indoor

installation

WSHH

 ® 

WSHH - WSH

data refer to the following conditions:[1] size 3.390÷3.540; evaporator water = 13/7 °C; condenser water = 30/35 °C;

size 4.560÷4.720; evaporator water = 12/7 °C; condenser water = 29/35 °C;[2] size 3.390÷3.540; condenser water = 40/45 °C; evaporator water = 13/7 °C;

size 4.560÷4.720; condenser water = 39/45 °C; evaporator water = 12/7 °C;

[3] the sound levels refer to the unit at full load, in the rated test conditions. The sound pressure level refersto a distance of 1m from the external surface of the units operating in an open field.

designed to obtain maximum efficiency

over time.

Maximum respect for the environment

• with the ecological refrigerant the unitcomplies with the strictest pollution

control and environmental protection

standards.

Energy saving

• part or all of the normally-lost

condensing energy can be recovered, for

the production of hot water for a variety

of uses.

Possible Configurations

Unit for production of chilled

water to -8°C

Partial recovery of the condensing

heat up to 10%

 Total condensing heat recovery

Water to water heat pump with

reversal on the water circuit

Standard

B

D

R

H

S

25

     H     Y     D     R     O     N     I     C

Sizes

DIVISION   

R407C

R22

CLIVET is an active member of the

EUROVENT certification program.

Wsh R407C

Wshh R407C

Length

Depth

Height

kW

kW

Kg

dB(A)

mm

mm

mm

Cooling capacity [1]

Heating capacity [2]

Shipping weight

Sound pressure level [3]

No. & Type of Compressors

Dimensions

CLIVET is an active member of the

EUROVENT certification program.

Reliability and build quality 

• the use of plate exchangers, specifically

designed for use with ecological gas

and with perfectly opposing flows,optimises the heat exchange of the

water on the utility side.

Energy saving

• in systems with widely varying loads,

the reduced load phases are managed

intelligently so as to minimise energy

consumption.

WSHHWSHWater to water heat pump

(reversible water circuit) for indoor

installation

Water cooled water chiller

for indoor installation

 ® 

data refer to the following conditions:[1] evaporator water = 12/7°C; condenser water = 30/35°C;[2] evaporator water = 12/7°C; condenser water outlet temperature 40/45°C;

[3] the sound levels refer to the unit at full load, in the rated test conditions. The sound pressure level refersto a distance of 1m from the external surface of the units operating in an open field.24

Low noise Level

• wherever silent operation is required,

the units can be configured for reduced

noise emissions and transmission of vibrations to the support structures.

Control Logic

• the unit dynamically modulates the

temperature of the chilled fluid

according to the outside temperature,

thus optimising energy efficiency.

Suitable for any kind of installation

• the condensing heat can be rejected by

water to waste (well) or a closed circuit

(tower), to suit a variety of systems

needs.

DIVISION   

   2 .   9   0  ÷   2 .   3   6   0

     H     Y     D     R     O     N     I     C

R407C

R22

HYDRONIC SPLIT SYSTEM PACKAGED

WSH - WSHH

Wsh R407C

Wshh R407C

Length

Depth

Height

kW

kW

Kg

dB(A)

mm

mm

mm

Sizes

Single screw compressor

with satellites

Braze welded plate

exchanger

240,2 289,2 324,1 345,0 386,6 407,7 436,3 490,9 578,2 659,8 730,8 801,9 838,3 874,8

285,0 337,3 377,5 403,5 458,3 482,6 516,5 587,0 688,6 783,2 864,4 945,6 1006,51067,5

1531 1696 1829 1878 1931 2279 2294 2397 2447 2587 2900 3226 3272 3318

74 74 75 76 77 77 77 78 78 79 79 79 80 80

2 Single Screw

3620 3620 3620 3620 3620 3780 3780 3780 3780 4150 4150 4150 4150 4150

1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200

2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000

2 .9 0 2 .10 0 2 .1 10 2 .1 25 2. 14 0 2 .1 55 2 .17 0 2. 20 0 2 .2 30 2 .2 60 2 .2 80 2 .30 0 2. 33 0 2 .3 60

866,0 938,91000,41080,51130,71180,91231,21321,51381,41455,31503,41561,01609,01666,8

1063,91143,01213,71304,11378,31452,41526,51590,01660,41742,91815,01896,81968,82050,6

3759 4324 4664 5004 5045 5086 5127 6443 6740 7008 7040 7072 7104 7136

80 80 80 80 81 81 81 82 82 82 83 83 83 83

3 Single Screw 4 Single Screw

4300 4300 4300 4300 4300 4300 4300 4600 4600 4600 4600 4600 4600 4600

1815 1815 1815 1815 1815 1815 1815 2340 2340 2340 2340 2340 2340 2340

2150 2250 2250 2300 2300 2300 2300 1900 1900 1900 1900 1900 1900 1900

3 .390 3 .410 3 .430 3 .450 3 .480 3 .510 3 .540 4 ,560 4 ,580 4 .600 4 .630 4 .660 4 .690 4 .720

Possible Configurations

Unit for production of chilled

water to -8°C

Partial recovery of the condensing

heat up to 10%

 Total condensing heat recovery

Water to water heat pump

with reversal on the water circuit

Standard

B

D

R

H

S

S in gl e s cr ew co mp re ss or S he ll an d t ub e h ea t

exchanger

ST

LNEN

Configuration:

Standard

Low noise

Extremely low noise

ST

LNEN

Configuration:

Standard

Low noise

Extremely low noise

7/23/2019 Clivet Toplotne Pumpe

http://slidepdf.com/reader/full/clivet-toplotne-pumpe 9/15

Unit with semi-hermetic screw type compressor

 TERMINAL U NIT  GEOTHERMIC CLOSECONTROL

Unit with semi-hermetic screw type compressor

Cooling capacity [1]

Heating capacity [2]

Shipping weight

Sound pressure level [3]

No. & Type of Compressors

Dimensions

6 19 ,0 6 80, 0 7 54 ,5 7 81 ,9 8 16 ,7 8 44, 8 94 6, 3 1 012 ,6 10 38 ,5 1 06 4,4 1 10 7, 6 1 15 0, 8

697,9 768,0 845,1 877,1 915,3 948,1 1060, 8 1132, 4 1165, 6 1198, 8 1247, 1 1295, 5

3958 4169 4604 4632 4661 4689 6319 6516 6551 6572 6602 6628

77 77 77 78 78 78 79 79 80 80 80 80

3 Single Screw 4 Single Screw

4300 4300 4300 4300 4300 4300 4650 4650 4650 4650 4650 4650

1815 1815 1815 1815 1815 1815 2340 2340 2340 2340 2340 2340

2150 2150 2200 2200 2200 2200 1700 1700 1700 1700 1700 1700

Low noise Level

• wherever silent operation is required, the

units can be configured for reduced

noise emissions and transmission of vibrations to the support structures.

Control Logic

• the unit dynamically modulates the

temperature of the chilled fluid according

to the outside temperature, thus

optimising energy efficiency.

Suitable for any kind of installation

• the condensing heat can be rejected by

water to waste (well) or a closed circuit

(tower), to suit a variety of systems

needs.

Water cooled water chiller

for indoor installation

   3 .   2   6   0  ÷   4 .   4   8   0

WSHWater to water heat pump

(reversible water circuit) for

indoor installation

WSHH

 ® 

WSHH - WSH

data refer to the following conditions:[1] evaporator water = 12/7°C; condenser water = 30/35°C;[2] condenser water = 40/45°C; evaporator water = 10/5°C;

[3] the sound levels refer to the unit at full load, in the rated test conditions. The sound pressure level refersto a distance of 1m from the external surface of the units operating in an open field.

Maximum respect for the environment

• with the ecological refrigerant the unit

complies with the strictest pollution

control and environmental protectionstandards.

High efficiency 

• part or all of the normally-lost

condensing energy can be recovered,

for the production of hot water for a

variety of uses.

Possible Configurations

Unit for production of chilled

water to -8°C

Partial recovery of the condensing

heat up to 10%

Water to water heat pump with

reversal on the water circuit

 Total condensing heat recovery

Standard

B

D

H

R

S

27

     H     Y     D     R     O     N     I     C

Sizes

DIVISION   

R134a

CLIVET is an active member of the

EUROVENT certification program.

Wsh R134a

Wshh R134a

Length

Depth

Height

Kw

Kw

Kg

dB(A)

mm

mm

mm

CLIVET is an active member of the

EUROVENT certification program.

Reliability and build quality 

• exclusive single-screw compressors

with avant-garde technology offering

excellent performance.Everything you need from a chiller

• our units stand out on the market for

their excellent performance and

competitive costs.

Time is precious

• the careful design allows the unit to be

handled, positioned and connected on

site with extreme simplicity.

WSHHWSHWater to water heat pump

(reversible water circuit) for

indoor installation

Water cooled water chiller

for indoor installation

 ® 

data refer to the following conditions:[1] evaporator water = 12/7 °C; condenser water = 30/35 °C;[2] evaporator water = 10/5 °C; condenser water = 40/45 °C;

[3] the sound levels refer to the unit at full load, in the rated test conditions. The sound pressure level refersto a distance of 1m from the external surface of the units operating in an open field.26

Control Logic

• analyses the thermal requirements of 

the system, optimising the compressor

starts and stops.• in systems with widely varying loads,

the reduced load phases are managed

intelligently so as to minimise energy

consumption.

Can be installed anywhere

• the special structure with base made

from thick galvanised steel plate section

bars ensures uniform weight

distribution.

DIVISION   

   2 .   9   0  ÷   2 .   2   4   0

     H     Y     D     R     O     N     I     C

R134a

HYDRONIC SPLIT SYSTEM PACKAGED

Possible Configurations

Unit for production of chilled

water to -8°C

Partial recovery of the

condensing heat up to 10%

Water to water heat pump with

reversal on the water circuit

 Total condensing heat recovery

Standard

B

D

H

R

S

Shell and tube heat

exchanger

3.260 3.280 3.300 3.320 3.340 3.360 4.380 4.400 4.420 4.440 4.460 4.480

Single screw compressor

with satellites

S in gl e s cr ew co mp re ss or S he ll an d t ub e h ea t

exchanger

Cooling capacity [1]

Heating capacity [2]

Shipping weight

Sound pressure level [3]

No. & Type of Compressors

Dimensions

WSH - WSHH

Wsh R134a

Wshh R134a

Length

Depth

Height

kW

kW

Kg

dB(A)

mm

mm

mm

Sizes

238,6 281,5 313,3 344,5 381,0 440,0 506,3 532,2 575,4

270,1 316,4 355,1 386,8 424,8 494,6 566,2 599,4 647,8

1791 1940 2033 2152 2327 2808 3241 3251 3335

71 73 73 75 75 76 77 77 77

2 Single Screw

3200 3400 3700 3700 3700 4600 4600 4600 4600

895 1000 1000 1000 1000 1200 1200 1200 1200

1300 1500 1500 1500 1500 1800 1800 1800 1800

2.90 2.110 2.130 2.145 2.160 2.180 2.200 2.220 2.240

ST

LNEN

Configuration:

Standard

Low noise

Extremely low noise

ST

LNEN

Configuration:

Standard

Low noise

Extremely low noise

7/23/2019 Clivet Toplotne Pumpe

http://slidepdf.com/reader/full/clivet-toplotne-pumpe 10/15

Unit with hermetic scroll type compressor

 TERMINAL U NIT  GEOTHERMIC CLOSECONTROL

Unit with semi-hermetic reciprocating type compressor

Cooling capacity [1]

Shipping weight

Sound pressure level [2]

No. & Type of Compressors

Dimensions

Discrete

• compact dimensions.

• quiet operation.

Everything you need from a chiller

• our units stand out on the market for

their excellent performance and

competitive costs.

Condenserless water

chiller for indoor installation

with remote condenser

   1   7  ÷   1   2   1

ME

 ® 

ME

data refer to the following conditions:[1] evaporator water = 12/7°C; condensing temperature = 50°C;

[2] the sound levels refer to the unit at full load, in the rated test conditions. The sound pressure level refersto a distance of 1m from the external surface of the units operating in an open field.

Extremely versatile

• hydronic assembly installed in the unit.

Possible Configurations

Operation with chilled fluid, outlet

temperature to -7°C

Remote control

Serial communication module to interface

with the most modern supervisor systems

29

     H     Y     D     R     O     N     I     C

Sizes

DIVISION   

R407C

R22

CLIVET is an active member of the

EUROVENT certification program.

Me R407C

Length

Depth

Height

kW

Kg

dB(A)

mm

mm

mm

Cooling capacity [1]

Heating capacity [2]

Shipping weight

Sound pressure level [3]

No. & Type of Compressors

Dimensions

CLIVET is an active member of the

EUROVENT certification program.

High efficiency 

• new generation water exchangers for

eliminating the heat with solutions

designed to obtain maximum efficiencyover time.

Time is precious

• the careful design allows the unit to be

handled, positioned and connected on

site with extreme simplicity.

WRHHWRHWater to water heat pump

(reversible water circuit) for

indoor installation

Water cooled water chiller

for indoor installation

 ® 

data refer to the following conditions:[1] condenser water = 12/7°C; evaporator water = 30/35°C;[2] condenser water = 40/45°C; evaporator water = 12/7°C;

[3] the sound levels refer to the unit at full load, in the rated test conditions. The sound pressure level refersto a distance of 1m from the external surface of the units operating in an open field.28

Control Logic

• a series of units installed to operate in

the same circuit communicate with

each other to optimise the managementof the various components.

• in systems with widely varying loads,

the reduced load phases are managed

intelligently so as to minimise energy

consumption.

Suitable for any kind of installation

• for renovations and all cases where

space is limited, the compact

dimensions of the unit simplify

installation.

DIVISION   

   2 .   7   0  ÷   2 .   1   4   0

     H     Y     D     R     O     N     I     C

R407C

HYDRONIC SPLIT SYSTEM PACKAGED

WRH - WRHH

Wrh R407C

Wrhh R407C

Length

Depth

Height

kW

kW

Kg

dB(A)

mm

mm

mm

Sizes

Possible Configurations

Unit for production of chilled

water to -8°C

Partial recovery of condensingheat, up to 15%

Water to water heat pump withreversal on the water circuit

 Total condensing heat recovery

Standard

B

D

H

R

S

178,8 200,8 218,9 238,2 256,5 292,0 317,2 349,1 364,6

213,8 239,1 260,0 277,5 299,2 345,6 376,2 417,4 443,0

1139 1182 1213 1369 1480 1515 1559 1575 1573

80 80 80 81 81 81 81 84 86

2 Reciprocating

2750 2750 2750 2750 2750 2750 2750 2750 2750

770 770 770 770 770 770 770 770 770

1360 1360 1360 1360 1360 1360 1360 1360 1360

2.70 2.75 2.80 2.90 2.100 2.110 2.120 2.130 2.140

5,0 6,2 7,6 8,7 11,2 13,4 15,9 17,8 19,5 23,4 27,2 33,5

77 80 85 87 91 92 93 93 113 113 113 119

49 49 49 49 50 50 50 50 59 59 60 62

1 Scroll

402 402 402 402 402 402 402 402 402 402 402 402

487 487 487 487 602 602 602 602 602 602 602 602

790 790 790 790 790 790 790 790 915 915 915 915

17 21 25 31 41 51 61 71 81 91 101 121

Braze welded plate

exchanger

Reciprocating

compressor

Hermetic compressor

Scroll type

ST

LNEN

Configuration:

Standard

Low noise

Extremely low noise

7/23/2019 Clivet Toplotne Pumpe

http://slidepdf.com/reader/full/clivet-toplotne-pumpe 11/15

Unit with semi-hermetic screw type compressor

 TERMINAL U NIT  GEOTHERMIC CLOSECONTROL

Unit with hermetic scroll type compressor

Cooling capacity [1]

Shipping weight

Sound pressure level [2]

No. & Type of Compressors

Dimensions

Control Logic

• analyses the thermal requirements of 

the system, optimising the compressor

starts and stops.Can be installed anywhere

• the special structure with base made

from thick galvanised steel plate section

bars ensures uniform weight

distribution.

Reliability and build quality 

• exclusive single-screw compressors

with avant-garde technology offering

excellent performance.

Condenserless water

chiller for indoor installation

with remote condenser

   2 .   9   0  ÷   2 .   3   6   0

MSE

 ® 

MSE

data refer to the following conditions:[1] evaporator water = 12/7°C; condensing temperature = 45°C;[2] the sound levels refer to the unit at full load, in the rated test conditions. The sound pressure level refers

to a distance of 1m from the external surface of the units operating in an open field.

High efficiency 

• the use of plate exchangers, specifically

designed for use with ecological gas

and with perfectly opposing flows,optimises the heat exchange of the

water on the utility side.

Energy saving

• part or all of the normally-lost

condensing energy can be recovered,

for the production of hot water for a

variety of uses.

Possible Configurations

Unit for production of chilled

water to -8°C

Partial recovery of condensing

heat, up to 15%

Standard

B

D

S

31

     H     Y     D     R     O     N     I     C

Sizes

DIVISION   

R407C

R22

CLIVET is an active member of the

EUROVENT certification program.

Mse R407C

Length

Depth

Height

kW

Kg

dB(A)

mm

mm

mm

Cooling capacity [1]

Shipping weight

Sound pressure level [2]

No. & Type of Compressors

Dimensions

CLIVET is an active member of the

EUROVENT certification program.MECondenserless water chiller

for indoor installation with

remote condenser

 ® 

data refer to the following conditions:[1] evaporator water = 12/7°C; condensing temperature = 50°C;

[2] the sound levels refer to the unit at full load, in the rated test conditions. The sound pressure level refersto a distance of 1m from the external surface of the units operating in an open field.30

Discrete

• compact dimensions.

• quiet operation.

Possible Configurations

Solution to optimize the installation

Operation with chilled fluid, outlet

temperature to -7°C

Remote control

Serial communication module to interface

with the most modern supervisor systems

DIVISION   

   1   0   2  ÷   4   2   2

     H     Y     D     R     O     N     I     C

R407C

R22

HYDRONIC SPLIT SYSTEM PACKAGED

ME

Me R407C

Length

Depth

Height

kW

Kg

dB(A)

mm

mm

mm

Sizes

25,7 34,2 37,5 45,1 52,5 58,5 64,5 82,1 96,9 112,7 137,8

158 193 232 232 239 245 250 410 445 468 520

53 53 62 62 63 64 65 66 66 66 66

2 Scroll

802 802 802 802 802 802 802 580 580 580 580

602 602 602 602 602 602 602 1062 1062 1062 1062

790 790 915 915 915 915 915 1538 1538 1538 1538

102 142 162 182 202 222 242 292 322 362 422

Single screw compressor

222,8 266,2 296,7 316,8 361,9 380,3 407,7 459,7 542,2 618,7 682,9 747,2 785,3 823,4

1381 1543 1673 1719 1769 1997 1992 2083 2127 2252 2548 2874 2920 2966

74 74 75 76 77 77 77 78 78 79 79 79 80 80

2 Single Screw

3620 3620 3620 3620 3620 3780 3780 3780 3780 4150 4150 4150 4150 4150

1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200

2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000

2 .9 0 2 .1 00 2 .1 10 2 .1 25 2 .14 0 2. 15 5 2 .1 70 2 .20 0 2 .2 30 2 .2 60 2. 28 0 2 .3 00 2 .33 0 2. 36 0

Hermetic compressor

Scroll type

Braze welded plate

exchanger

ST

LNEN

Configuration:

Standard

Low noise

Extremely low noise

7/23/2019 Clivet Toplotne Pumpe

http://slidepdf.com/reader/full/clivet-toplotne-pumpe 12/15

Cooling capacity [1]

Shipping weight

Sound pressure level [2]

No. & Type of Compressors

Dimensions

MSE 3.260-4.480

Potenzialità frigorifera [1]

Cooling capacity [1]

Shipping weight

Sound pressure level [2]

No. & Type of Compressors

Dimensions

Unit with semi-hermetic screw type compressor

 TERMINAL U NIT  GEOTHERMIC CLOSECONTROL

Unit with semi-hermetic screw type compressor

226,6 265,0 295,7 324,5 358,1 414,2 476,9 501,4 540,9

1741 1889 1981 2099 2273 2753 3185 3194 3277

71 73 73 75 75 76 77 77 772 Single Screw

3200 3400 3700 3700 3700 4600 4600 4600 4600

895 1000 1000 1000 1000 1200 1200 1200 1200

1300 1500 1500 1500 1500 1800 1800 1800 1800

3.260 3.280 3.300 3.320 3.340 3.360 4.380 4.400 4.420 4.440 4.460 4.480

5 83 ,4 6 41, 1 7 10 ,5 7 36 ,1 7 68 ,0 7 94, 3 89 1, 1 9 53 ,9 9 78 ,3 1 00 2,8 1 04 2, 3 1 08 1, 9

3898 4108 4542 4569 4597 4624 6253 6449 6483 6503 6532 6557

77 77 77 78 78 78 79 79 80 80 80 80

3 Single Screw 4 Single Screw

4300 4300 4300 4300 4300 4300 4650 4650 4650 4650 4650 4650

1815 1815 1815 1815 1815 1815 2340 2340 2340 2340 2340 2340

2150 2150 2200 2200 2200 2200 1700 1700 1700 1700 1700 1700

Can be installed anywhere

• the special structure with base made

from thick galvanised steel plate section

bars ensures uniform weightdistribution.

Flexibility of use

• exclusive single-screw compressors

with avant-garde technology offering

excellent performance.

Reliability and build quality 

• exclusive single-screw compressors

with avant-garde technology offering

excellent performance.

Condenserless water

chiller for indoor installation

with remote condenser

   2 .   9   0  ÷   2 .   2   4   0

   3 .   2   6   0  ÷   4 .   4   8   0

MSE

 ® 

MSE 2.90-2.240

MSE 3.260-4.480

data refer to the following conditions:[1] evaporator water = 12/7°C; condensing temperature = 45°C;

[2] he sound levels refer to the unit at full load, in the rated test conditions. The sound pressure level refersto a distance of 1m from the external surface of the units operating in an open field.

 Accessibility 

• all the components is easily accessible

for any maintenance or replacement

operations, with significant savings intime and money.

Energy saving

• part or all of the normally-lost

condensing energy can be recovered,

for the production of hot water for a

variety of uses.

Possible Configurations

Unit for production of chilled

water to -8°C

Partial recovery of condensing

heat, up to 15%

Standard

B

D

S

33

     H     Y     D     R     O     N     I     C

Sizes

DIVISION   

R134a

CLIVET is an active member of the EUROVENT

certification program.

Mse R134a

Length

Depth

Height

Mse R134a

Length

Depth

Height

kW

Kg

dB(A)

mm

mm

mm

kW

Kg

dB(A)

mm

mm

mm

Cooling capacity [1]

Shipping weight

Sound pressure level [2]

No. & Type of Compressors

Dimensions

CLIVET is an active member of the

EUROVENT certification program.

Suitable for any kind of installation

• for renovations and all cases where

space is limited, the compact

dimensions of the unit simplifyinstallation.

Reliability and build quality 

• guaranteed quality of all the

components installed.

MSECondenserless water chiller

for indoor installation with

remote condenser

 ® 

data refer to the following conditions:[1] size 3.390÷3.540; evaporator water = 13/7 °C; condensing temperature = 45°C;

size 4.560÷4.720; evaporator water = 12/7 °C; condensing temperature = 45°C;

[2] the sound levels refer to the unit at full load, in the rated test conditions. The sound pressure level refersto a distance of 1m from the external surface of the units operating in an open field.32

Low noise Level

• wherever silent operation is required,

the units can be configured for reduced

noise emissions and transmission of vibrations to the support structures.

Control Logic

• the unit dynamically modulates the

temperature of the chilled fluid

according to the outside temperature,

thus optimising energy efficiency.

• a series of units installed to operate in

the same circuit communicate with

each other to optimise the management

of the various components.

DIVISION   

   3 .   3   9   0  ÷   4 .   7   2   0

     H     Y     D     R     O     N     I     C

R407C

R22

HYDRONIC SPLIT SYSTEM PACKAGED

MSE

Mse R407C

Length

Depth

Height

kW

Kg

dB(A)

mm

mm

mm

Sizes

Possible Configurations

Unit for production of chilled

water to -8°C

Partial recovery of condensing

heat, up to 15%

Standard

B

D

S

830,9 900,0 958,41034,41084,01133,51183,01229,21283,11349,71398,61457,11506,01564,5

3708 4316 4656 5032 4990 5031 5071 6465 6732 7021 7052 7045 7076 7050

80 80 80 80 81 81 81 82 82 82 83 83 83 83

3 Single Screw 4 Single Screw

4300 4300 4300 4300 4300 4300 4300 4600 4600 4600 4600 4600 4600 4600

1815 1815 1815 1815 1815 1815 1815 2340 2340 2340 2340 2340 2340 2340

2150 2250 2250 2300 2300 2300 2300 1900 1900 1900 1900 1900 1900 1900

3.390 3.410 3.430 3.450 3.480 3.510 3.540 4.560 4.580 4.600 4.630 4.660 4.690 4.720 2.90 2.110 2.130 2.145 2.160 2.180 2.200 2.220 2.240

Single screw compressor

with satellites

Single screw compressorShell and tube heat

exchanger

Shell and tube heat

exchanger

ST

LNEN

Configuration:

Standard

Low noise

Extremely low noise

ST

LNEN

Configuration:

Standard

Low noise

Extremely low noise

7/23/2019 Clivet Toplotne Pumpe

http://slidepdf.com/reader/full/clivet-toplotne-pumpe 13/15

Unit with semi-hermetic reciprocating type compressor

 TERMINAL U NIT  GEOTHERMIC CLOSECONTROL

Unit with semi-hermetic reciprocating type compressor

Cooling capacity [1]

Shipping weight

Sound pressure level [2]

No. & Type of Compressors

Dimensions

Low noise Level

• wherever silent operation is required,

the units can be configured for reduced

noise emissions and transmission of vibrations to the support structures.

Regulation

• a series of units installed to operate in

the same circuit communicate with

each other to optimise the management

of the various components.

Can be installed anywhere

• the special structure with base made

from thick galvanised steel plate section

bars ensures uniform weight

distribution.

Condenserless water

chiller for indoor installation

with remote condenser

   2 .   7   0  ÷   4 .   2   4   0

ME

 ® 

ME

data refer to the following conditions:[1] evaporator water = 12/7°C; condensing temperature = 45°C;

[2] the sound levels refer to the unit at full load, in the rated test conditions. The sound pressure level refersto a distance of 1m from the external surface of the units operating in an open field.

 Accessibility 

• all the components is easily accessible

for any maintenance or replacement

operations, with significant savings intime and money.

Suitable for any kind of installation

• part or all of the normally-lost

condensing energy can be recovered,

for the production of hot water for a

variety of uses.

Possible Configurations

Unit for production of chilled

water to -8°C

Partial recovery of condensing

heat, up to 15%

Standard

B

D

S

35

     H     Y     D     R     O     N     I     C

Sizes

DIVISION   

R22

CLIVET is an active member of the EUROVENT

certification program.

Me R22

Length

Depth

Height

kW

Kg

dB(A)

mm

mm

mm

Cooling capacity [1]

Shipping weight

Sound pressure level [2]

No. & Type of Compressors

Dimensions

CLIVET is an active member of the

EUROVENT certification program.

Reliability and build quality 

• the use of plate exchangers, specifically

designed for use with ecological gas

and with perfectly opposing flows,optimises the heat exchange of the

water on the utility side.

Time is precious

• the careful design allows the unit to be

handled, positioned and connected on

site with extreme simplicity.

MECondenserless water chiller

for indoor installation with

remote condenser

 ® 

data refer to the following conditions:[1] evaporator water = 12/7°C; condensing temperature = 45°C;

[2] the sound levels refer to the unit at full load, in the rated test conditions. The sound pressure level refersto a distance of 1m from the external surface of the units operating in an open field.34

Control Logic

• analyses the thermal requirements of 

the system, optimising the compressor

starts and stops.• the unit dynamically modulates the

temperature of the chilled fluid

according to the outside temperature,

thus optimising energy efficiency.

Suitable for any kind of installation

• for renovations and all cases where

space is limited, the compact

dimensions of the unit simplify

installation.

• in systems with widely varying loads,

the reduced load phases are managed

intelligently so as to minimise energy

consumption.

DIVISION   

   2 .   7   0  ÷   2 .   1   4   0

     H     Y     D     R     O     N     I     C

R407C

HYDRONIC SPLIT SYSTEM PACKAGED

ME

Me R407C

Length

Depth

Height

kW

Kg

dB(A)

mm

mm

mm

Sizes

Possible Configurations

Unit for production of chilled

water to -8°C

Partial recovery of condensing

heat, up to 25%

Standard

B

D

S

153,0 173,0 187,0 196,0 217,0 252,0 272,0 301,0 315,0

1040 1081 1117 1230 1329 1365 1436 1430 1437

80 80 80 81 81 81 81 84 86

2 Reciprocating

2750 2750 2750 2750 2750 2750 2750 2750 2750

770 770 770 770 770 770 770 770 770

1360 1360 1360 1360 1360 1360 1360 1360 1360

2.70 2.75 2.80 2.90 2.100 2.110 2.120 2.130 2.140

167,1 185,8 200,1 223,4 241,8 290,5 331,6 394,8 443,6 489,3 540,8 581,1

858 918 994 1123 1253 1630 1781 1978 2273 2453 2538 2642

82 82 82 82 82 85 85 85 85 85 87 88

2 Reciprocating 4 Reciprocating

2850 2850 2850 3049 3049 3080 3630 3630 3680 3680 3680 3680

700 700 700 700 700 700 950 950 950 950 950 950

1260 1290 1290 1290 1290 1365 1570 1570 1570 1570 1580 1580

2.70 2.75 2.80 2.90 2.100 2.120 4.140 4.160 4.180 4.200 4.220 4.240

Reciprocating

compressor

Reciprocating

compressor

ST

LNEN

Configuration:

Standard

Low noise

Extremely low noise

ST

LNEN

Configuration:

Standard

Low noise

Extremely low noise

7/23/2019 Clivet Toplotne Pumpe

http://slidepdf.com/reader/full/clivet-toplotne-pumpe 14/15

 TERMINAL U NIT  GEOTHERMIC CLOSECONTROLHYDRONIC SPLIT SYSTEM PACKAGED

0,300 0,450 0,300 0,450 0,550 0,750 0,450 0,550 0,750 0,900

0,80 1,20 0,80 1,20 1,50 2,00 1,20 1,50 2,00 2,40

72

87

8

800

150

65

150

600

400/3/50

600 x GPA 65 790 x GPA 150

470 x GPA 65 600 x GPA 150

790 x GPA 65 1186 x GPA 150

2 poles pump

Expansion tank 

Storage tank capacity

Safety valve regulation

Power supply

Dimensions

The hydraulic circuit is installed quickly 

• The hydraulic circuit is included in one

unit.

Control Logic• possibility of two pumps, one in reserve

to the other with automatic start.

Pumping station

   0   0  ÷   1   2

GP1Pumping station with

storage tank 

GP2

 ® 

GP1 - GP2

Ready to install: reliability and reduced

installation time

• choice of 12 pump sizes.

• storage tank available in 4 sizes.

Possible Configurations

Suitable kit available for connection

to chiller

 Three-way valve

 Auxiliary electric heating elements

 Adjustable connection from and to the

installation (GP1)

37

     H     Y     D     R     O     N     I     C

Sizes

DIVISION   

CLIVET is an active member of the

EUROVENT certification program.

Nominal power

Nominal abs. Current

Shipping weight

Capacity

Max pressure

Standard pressure

Length

Depth

Height

kW

 A 

Kg

L

kPa

kPa

L

kPa

 V/Ph/Hz

mm

mm

mm

2 poles pump

Expansion tank 

Storage tank capacity

Safety valve regulation

Power supply

Dimensions

CLIVET is an active member of the

EUROVENT certification program.

• wide range of available pump head

pressure.

• possibility to choose the right heating

inertia (2 sizes of storage tank).

GPA Pumping station with

storage tank 

 ® 

36

It does not leave empty space

• electrical panel.

• equipped with all hydraulic components

to optimize the installation.

Possible Configurations

Suitable kit available for connection

to chiller

 Adaptation for operation as primary and

secondary circuit

DIVISION   

   M   0  ÷   M   9

     H     Y     D     R     O     N     I     C

GPA 

Nominal power

Nominal abs. Current

Shipping weight

Capacity

Max pressure

Standard pressure

Length

Depth

Height

kW

 A 

Kg

L

kPa

kPa

L

kPa

 V/Ph/Hz

mm

mm

mm

Sizes

GPA 65GPA150

GPA65

GPA150

M0 M1 M2 M3 M4 M5 M6 M7 M8 M9

GP1

0,5 0,6 0,9 1,1 0,8 1,2 1,1 1,5 2 2,3 1,5 2,1 2,6

0,8 1,1 1,8 2 1,6 2,2 2 2,8 3,6 4,4 2,8 3,6 4,5

70

130xGP2(300) 170xGP2(500) 205xGP2(600) 260xGP2(1000)

12 x GP1 16 x GP2 (300 e 500L) 24 x GP2 (600L) 32 x GP2 (1000L)

800

150

300 - 500 - 600 - 1000

600

400/3/50

616 (GP1.1 - GP1.2) 831 (GP2.1 - 300-500) 1356 (GP2.2 - 600-1000)

514 (GP1.1 - GP1.2) 831 (GP2.1 - 300-500) 865 (GP2.2 - 600-1000)

1299 (GP1.1 - GP1.2) 1502 (300) 2225 (500) 1502 (600) 2225 (1000)

GP1

GP2

GP2

00 1 2 3 4 5 6 7 8 9 10 11 12

GP2

Water pump close

coupled, body instainless steel, highefficiency single impeller

Water pump close

coupled, body instainless steel, high

efficiency single impeller

7/23/2019 Clivet Toplotne Pumpe

http://slidepdf.com/reader/full/clivet-toplotne-pumpe 15/15

2 poles pump

Expansion tank 

Storage tank capacity

Safety valve regulation

Power supply

Dimensions

1,5 2,20 3,00 4,00

3,6 4,90 6,50 8,50

305 310 340 34524(600L) 32(1000L)

800

150

600 1000

600

400/3/50

1355

911

1505 x (600L) 2225 x (1000L)

Centrifugal pump

Expansion tank 

Storage tank capacity

Safety valve regulation

Power supply

Dimensions

2 4

1,5 2,2 3,0 4,0 2,2 3,0 4,0 5,5 5,5 7,5 11,0 0,75 1,5 2,2 1,1 1,5 2,2 4,0 5,5 5,5 7,5

3 ,6 4 ,9 6 ,5 8 ,5 4 ,9 6 ,5 8 ,5 11, 511,515, 522,0 2 ,1 3 ,6 5 ,2 2 ,8 3 ,6 5 ,2 8 ,7 12, 412,415, 8552 556 565 574 570 572 582 610 625 628 674 579 595 614 601 602 633 698 710 710 720

74

800

150

1200 (2400 optional)

600

400/3/50

2040

1260 (1200L) 2520 (2400 L)

2113

 TERMINAL U NIT  GEOTHERMIC CLOSECONTROLHYDRONIC SPLIT SYSTEM PACKAGED

Low noise Level

• wherever silent operation is required,

the units can be configured for reduced

noise emissions and transmission of vibrations to the support structures.

Control Logic

• possibility of two pumps, one in reserve

to the other with automatic start.

Pumping station with

storage tank 

   6   0  ÷   9   9

GPM

 ® 

GPM

Certification

• guaranteed quality of all the

components installed.

• unit manufactured according to the ISO9001 quality standards and subject to

functional testing at the end of the

production line.

Possible Configurations

Standard

Primary circuit and fitted for the

secondary

1200 litre storage

2400 litre storage

S

P

 A1

 A2

39

     H     Y     D     R     O     N     I     C

Sizes

DIVISION   

CLIVET is an active member of the

EUROVENT certification program.

Nominal power

Nominal abs. Current

Shipping weight (1200 L)

Capacity

Max pressure

Standard pressure

Length

Depth

Height

N° poles

kW

 A 

Kg

L

kPa

kPa

L

kPa

 V/Ph/Hz

mm

mm

mm

CLIVET is an active member of the

EUROVENT certification program.

Control Logic

• possibility of two pumps, one in reserve

to the other with automatic start.

GP7Pumping station with

storage tank 

 ® 

38

“There is nothing else to be added”

• The hydraulic circuit is included in one

unit.

• equipped with all hydraulic componentsto optimize the installation.

 Applicative versatility 

• wide range of available pump head

pressure.

• 600 or 1000 l. storage tank.

Possible Configurations

Suitable kit available for connectionto chiller

 Antifreeze heater with safety thermostat

 Auxiliary electric heating elements

DIVISION   

   1   /   2  p  o  m  p  e

   6   0   0   /   1   0   0   0   l

     H     Y     D     R     O     N     I     C

GP7

Nominal power

Nominal abs. Current

Shipping weight

Capacity

Max pressure

Standard pressure

Length

Depth

Height

kW

 A 

Kg

L

kPa

kPa

L

kPa

 V/Ph/Hz

mm

mm

mm

Sizes

60 61 62 63 60 61 62 63 68 69 70 71 78 79 80 83 85 87 90 91 92 93 94 98 99

Centrifugal pump Centrifugal pump