conversion from sewercad to inforworkses

20
CONVERSION FROM SEWERCAD TO INFOWORKS

Upload: kelechinobi

Post on 05-Nov-2015

33 views

Category:

Documents


6 download

DESCRIPTION

Workflow for converting files from sewerCAD to InfoWorks via QGIS

TRANSCRIPT

  • CONVERSION FROM SEWERCAD

    TO INFOWORKSTO INFOWORKS

  • Working in SewerCAD

    Open SewerCAD model for Foul Water Project

    -Create flex table for Manholes, Conduits and Outfalls for required attributes

    -Create shape files from flex tables

  • Create Flextables For Mhs, Conduits and Outfalls in SewerCAD

  • Create Shape Files For Mhs, Conduits and Outfalls in SewerCAD

  • Create Shape Files For Mhs, Conduits and Outfalls in SewerCAD

  • Working in GIS

    - Open cadastral file in GIS to get PIN no. for each plot

    - Map PIN no. of plots to the MH no. and Population provided in Excel sheet

    - Create shape file for plots, manholes and population

  • Open Cadastral File in GIS

  • Map PIN nos. to Corresponding MHs and Population in GIS

  • Create shape file for Plots in GIS

  • Working in Infowroks CS

    Open InfoWorks Admin to Create a new master dataabse

    - Database new master database

    - Browse to preferred folder and give database a name

    - Database select master database

    - There are two boxes in the dialog: select preferred folder for Local root

    - InfoWorks will create a folder with a long name in this location, for new

    projects (for existing projects there needs to be a local root folder here)projects (for existing projects there needs to be a local root folder here)

    - Browse to location of preferred master database and select OK

    - View InfoWorks Explorer (opens active database)

    - For a new project create a new catchment group / model group as per

    project

    - Close IW Admin

  • Creating a new master database

  • Selecting a master database

  • Selecting a master database from list of recently used databases

  • Viewing a master database in InfoWorks Admin

  • Creating a Catchment or Model Group

  • Working in InfoWorks Proper

    Open InfoWorks CS For a Foul Water Project

    - Select Master Database (similar to Admin)

    - Create a new network

    - Import Full Flag Set

    - Set up User Defined Defaults

    - Import from SewerCAD using Open Data Import Centre (ODIC)

    - Note Import Nodes first (coordinate data): Elevation; Label and Dia- Note Import Nodes first (coordinate data): Elevation; Label and Dia

    - Outfalls are special types of nodes change type during import

    - Import Links next: Dia; USIL; DSIL; Start node; Stop node

    - Import subcatchments from GIS-cadastral - PIN

  • Create a new network in InfoWorks

  • Import User Defined Flags

  • Update User Defined Defaults

  • Import Network Objects using ODIC