Cryogenic accelerometer and sphere without DLC in Toshiba Dan Chen Cryogenic meeting 12th Dec. 2012 1 121212日水曜日

Upload: others

Post on 16-Mar-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Cryogenic accelerometer and sphere without DLC in …gwdoc.icrr.u-tokyo.ac.jp/DocDB/0014/G1201423/002/121212...Cryogenic accelerometer and sphere without DLC in Toshiba Dan Chen Cryogenic

Cryogenic accelerometer andsphere without DLC in Toshiba

Dan ChenCryogenic meeting 12th Dec. 2012

112年12月12日水曜日

Page 2: Cryogenic accelerometer and sphere without DLC in …gwdoc.icrr.u-tokyo.ac.jp/DocDB/0014/G1201423/002/121212...Cryogenic accelerometer and sphere without DLC in Toshiba Dan Chen Cryogenic

Out line

2

<1>Cryogenic accelerometer(1)Adaptor for new cryogenic cooler(2)Vacuum test(3)The tilt of the radiation shield

<2>The cooling test of a sphere without DLC in TOSHIBA

(1)Suspending in the radiation shield

12年12月12日水曜日

Page 3: Cryogenic accelerometer and sphere without DLC in …gwdoc.icrr.u-tokyo.ac.jp/DocDB/0014/G1201423/002/121212...Cryogenic accelerometer and sphere without DLC in Toshiba Dan Chen Cryogenic

3

Measurement of the vibration on the radiation shield.

Heat links

T=20K

8K80K

laser

Radiation shield

Cryo cooler

Cryo cooler

Purpose

This vibration is expected to be same with the ground.

Cooling pole

The vibration of the radiation shield may swing the test mass through the heat links.The scattering laser may be reflected by the shield and recombine into main laser.

We will measure the vibration on this radiation shield with cryocooler ON.The real measurement will be run in Toshiba(Yokohama-city) in December.

12年12月12日水曜日

Page 4: Cryogenic accelerometer and sphere without DLC in …gwdoc.icrr.u-tokyo.ac.jp/DocDB/0014/G1201423/002/121212...Cryogenic accelerometer and sphere without DLC in Toshiba Dan Chen Cryogenic

AccelerometerWe will have a cooling test of this

accelerometer.

4

Fixed mirror

Mirror with

coil ac

tuator

PD

PD

Optical fiberNew one

Chamber Cooler

12年12月12日水曜日

Page 5: Cryogenic accelerometer and sphere without DLC in …gwdoc.icrr.u-tokyo.ac.jp/DocDB/0014/G1201423/002/121212...Cryogenic accelerometer and sphere without DLC in Toshiba Dan Chen Cryogenic

Adaptor for new cooler

5

Adaptor

New cooler

The design is almost done.I will check the size.

Tokoku-san12年12月12日水曜日

Page 6: Cryogenic accelerometer and sphere without DLC in …gwdoc.icrr.u-tokyo.ac.jp/DocDB/0014/G1201423/002/121212...Cryogenic accelerometer and sphere without DLC in Toshiba Dan Chen Cryogenic

Vacuum test ofthe chamber

6

Chamber

Cooler

Turbo pump

Diaphragm pump(ダイアフロムポンプ)

Vacuum gauge

12年12月12日水曜日

Page 7: Cryogenic accelerometer and sphere without DLC in …gwdoc.icrr.u-tokyo.ac.jp/DocDB/0014/G1201423/002/121212...Cryogenic accelerometer and sphere without DLC in Toshiba Dan Chen Cryogenic

Vacuum test ofthe chamber

7

The pressure which we can switch on the cryo-cooler: 10�4[mbar]

The time to reach the above pressure: ~1 night

The minimum pressure: 10�6[mbar]

No problem

12年12月12日水曜日

Page 8: Cryogenic accelerometer and sphere without DLC in …gwdoc.icrr.u-tokyo.ac.jp/DocDB/0014/G1201423/002/121212...Cryogenic accelerometer and sphere without DLC in Toshiba Dan Chen Cryogenic

8

The tilt of the radiation shieldThe radiation shield can have initial tilt angle.

And the angle can change during the cooling test of the cryostat.

chamber

8K shield

80K shield

Initial tilt

chamber

8K shield80K shield

chamber

8K shield80K shield

Change because of the temperature change

Can our accelerometer work?12年12月12日水曜日

Page 9: Cryogenic accelerometer and sphere without DLC in …gwdoc.icrr.u-tokyo.ac.jp/DocDB/0014/G1201423/002/121212...Cryogenic accelerometer and sphere without DLC in Toshiba Dan Chen Cryogenic

9

PDφ2mm

the diameter of the laser ~ 1mm

100mm

The tilt of the radiation shieldThe initial tilt is OK because we can adjust the

alignments at the room temperature.

Change of the tilt angle

The requirement from our accelerometers is 6mrad(~0.34degree).

The change of the beam spot < 0.1mm

12年12月12日水曜日

Page 10: Cryogenic accelerometer and sphere without DLC in …gwdoc.icrr.u-tokyo.ac.jp/DocDB/0014/G1201423/002/121212...Cryogenic accelerometer and sphere without DLC in Toshiba Dan Chen Cryogenic

10

The tilt of the radiation shield

The requirement from Luca’s accelerometers is ~10mrad(~0.57degree).

The requirement from our accelerometers is 6mrad(~0.34degree).

The requirement value is 6mrad.

12年12月12日水曜日

Page 11: Cryogenic accelerometer and sphere without DLC in …gwdoc.icrr.u-tokyo.ac.jp/DocDB/0014/G1201423/002/121212...Cryogenic accelerometer and sphere without DLC in Toshiba Dan Chen Cryogenic

How much can the radiation shield tilt?(at the worst)

11

chamber8K shield

I assume these legs are 0K.

I assume these legs are 100K.

The tilt angler of the radiation shield is 1.4mrad(~0.08degree).

80K shield

No problem12年12月12日水曜日

Page 12: Cryogenic accelerometer and sphere without DLC in …gwdoc.icrr.u-tokyo.ac.jp/DocDB/0014/G1201423/002/121212...Cryogenic accelerometer and sphere without DLC in Toshiba Dan Chen Cryogenic

How much can the radiation shield tilt?(at the worst)

12

I assume these legs are 0K.I assume these

legs are 100K.

The tilt angler of the radiation shield is 1.4mrad(~0.08degree).

No problem

There are supports attached on the radiation shield.

12年12月12日水曜日

Page 13: Cryogenic accelerometer and sphere without DLC in …gwdoc.icrr.u-tokyo.ac.jp/DocDB/0014/G1201423/002/121212...Cryogenic accelerometer and sphere without DLC in Toshiba Dan Chen Cryogenic

The cooling test of a sphere without DLC in TOSHIBA

13

We are going to measure the temperature change of a sphere(without

DLC and with DLC) in the cryostat.

To confirm the scale law of the experiment of Sakakibara-kun

Last week, we suspended a sphere without DLC in the cryostat.

12年12月12日水曜日

Page 14: Cryogenic accelerometer and sphere without DLC in …gwdoc.icrr.u-tokyo.ac.jp/DocDB/0014/G1201423/002/121212...Cryogenic accelerometer and sphere without DLC in Toshiba Dan Chen Cryogenic

The cooling test of a sphere without DLC in TOSHIBA

14

10cm

There are two thermometers in

the sphere

12年12月12日水曜日

Page 15: Cryogenic accelerometer and sphere without DLC in …gwdoc.icrr.u-tokyo.ac.jp/DocDB/0014/G1201423/002/121212...Cryogenic accelerometer and sphere without DLC in Toshiba Dan Chen Cryogenic

The cooling test of a sphere without DLC in TOSHIBA

15

Kevlar wire

12年12月12日水曜日

Page 16: Cryogenic accelerometer and sphere without DLC in …gwdoc.icrr.u-tokyo.ac.jp/DocDB/0014/G1201423/002/121212...Cryogenic accelerometer and sphere without DLC in Toshiba Dan Chen Cryogenic

The impression in the radiation shield

16I am the first person of KAGRA who enter the KAGRA radiation shield!

Although the chamber is not so big inside, 3 or 4 person can work in the chamber.

2 person can work in the radiation shield.(using some footing)

Because the roof is not so high, you have to bend in the radiation shield.