Contrast scanner with static Teach-in on mark and background When especially high precision is required for contrast detection, e.g., in detecting marks on highly polished materials, the time (or – more precisely – the millisecond) is ripe for the KT5W-2___6 contrast scanner. Thanks to its three-color LED, the equipment can activate the optimum transmitter light source for every contrast. Additionally, it has an especially accurate, static Teach-in procedure. The gray values of the mark to be detected are taught-in sepa- rately here either via the Teach-in button on the equipment or an external control wire. The scanner sets the ideal switching threshold from the two determined gray values. The high precision of the contrast detection, automatic shine adjustment with material to be scanned with high reflectance, scan- ning distances of 10 mm, 20 mm and 40 mm, switching sequence of 10 kHz and in- dividual alignment and attachment options cover numerous tasks in which it is a ques- tions of “brilliant” detection results. Contrast Scanners KT5W-2 ___ 6 2 SICK 2007-09-05

Upload: amijoski6051

Post on 13-Jul-2016

2 views

Category:

Documents


1 download

DESCRIPTION

aContrast scanner with staticTeach-in on mark andbackground assaxa

TRANSCRIPT

Contrast scanner with staticTeach-in on mark and background

When especially high precision is required for contrast detection, e.g., in detecting marks

on highly polished materials, the time (or – more precisely – the millisecond) is ripe for

the KT5W-2___6 contrast scanner.

Thanks to its three-color LED, the equipment can activate the optimum transmitter light

source for every contrast. Additionally, it has an especially accurate, static Teach-in

procedure. The gray values of the mark to be detected are taught-in sepa-

rately here either via the Teach-in button on the equipment or an

external control wire. The scanner sets the ideal switching

threshold from the two determined gray values.

The high precision of the contrast detection,

automatic shine adjustment with material

to be scanned with high reflectance, scan-

ning distances of 10 mm, 20 mm and 40

mm, switching sequence of 10 kHz and in-

dividual alignment and attachment options

cover numerous tasks in which it is a ques-

tions of “brilliant” detection results.

Cont

rast

Sca

nner

s KT5

W-2

__

_ 6

2 S I C K 2 0 0 7 - 0 9 - 0 5

2 0 0 7 - 0 9 - 0 5 S I C K 3

Note

sSt

atus

Teac

h-in

: set

ting

switc

hing

thre

shol

d

KT5W-2_ _ _6

RUNTEACH

RUNTEACH

Q

Light-/dark-switching not required: equipment switches for the material to be scanned, which was under the light spot at the first Teach-in procedure (mark or background).

The material speed must be zero during Teach-in (machine is idle).

The Teach-in button can be locked against unintentional activation with “Run”. A Teach-in procedure can be triggered when the switch setting is not defined.

After the first Teach-in procedure, the red transmitter light and the status indicator blink and signal that a second Teach-in procedure must be triggered.

The optimum transmission light was selected automatically.

Q

ET L+or

ET L++

ET L+or

ET L++

Switching threshold Switching threshold

Internal analogue signal QA

Output Q Output Q

Internal analogue signal QA

4 S I C K 2 0 0 7 - 0 9 - 0 5

RUN

T E A C H

Q

TEACH

6

7

5

8016

522813

3.5

25

40 5

33

0.4

21

3

2856

9

5M

M5

3

12

2

4

C U V

■ Static Teach-in to mark and back-ground via control cable or control panel on unit

■ Automatic switching threshold adjustment for detection of extremely shiny objects

■ Switching frequency 10 000/s■ Light source red, green, blue

Dimensional drawing

Cables and connectors Mounting systems Lens

3

1

All types

All types

Adjustments possible Lens (light transmission), can be replaced by item M5 mounting holes, 5.5 mm deep Blind screw, can be replaced by item 5-pin, M12 x 1 plug (rotatable through 90°) Function signal indicator (yellow) Pre-selection switch Teach-in button 7

6

5

4

3

2

1

Connection type

Accessories

KT5W-2_ _ _6 Contrast scanners

Scanning distance 10/20/40 mm

Contrast scanners KT5W-2P1116 KT5W-2P1126

KT5W-2P1316 KT5W-2N1316

ø25

.5

3.5

KT5W-2P1216 KT5W-2N1216

4.5

ø25

.6

17.4

ø26

KT5W-2B1116

5-pin, M12 x 1

1L+

Q

M

NC

ET

4

3

2

5

brn

blk

blu

wht

gra

ON

KT5W-2P1116

4-pin, M12 x 1

1L+

QP

M

QN

4

3

2

brn

blk

blu

wht

ON

KT5W-2N1116 KT5W-2P1126 KT5W-2P1216 KT5W-2P1216

KT5W-2B1116

KT5W-2N1316

2 0 0 7 - 0 9 - 0 5 S I C K 5

KT5W-2P1126

1) Average service life 100,000 h at TA = + 25 °C

2) Limit values

5) Signal transit time with resistive load6) Reference voltage 32 V DC

3) May not exceed or fall short of VS tolerances

4) Without load

7) A = VS connections reverse-polarity protected

B = Outputs short-circuit protected C = Interference pulse suppression

1018587 KT5W-2P1216 1018586 KT5W-2P1316 1018961 KT5W-2N1116 1018045 KT5W-2N1216 1019022 KT5W-2N1316 1022678

Technical data KT5W-2 P1116 P1126 P1216 P1316 N1116 N1216 N1316 B1116

KT5W-2P1116 1018044

Order no. Preferred type *)

Order information

Scanning distance 10 ± 3 mmfrom front edge of lens 20 ± 3 mm 40 ± 3 mmLight spot dimensions 1.2 x 4.2 mm 1.5 x 5.5 mm 1.1 x 4.2 mmLight source1); light type; LED; red, blue, green; Wavelength (nm) 640, 525, 470Supply voltage VS 10... 30 V DC2)

Residual ripple3) < 5 VPP

Current consumption4) < 80 mA Switching outputs PNP: HIGH = VS – < 2 V / LOW = 0 V NPN: HIGH = VS / LOW = < 2 VOutput current IA max. 100 mA short-circuit protectedResponse time5); switching frequency 50 μs; 10000/sTime delay No timing element Deactivation delay, ... 20 msTeach-in input ET PNP: Teach > 10 V...< VS

Run 0 V or unswitched NPN: Teach 0 V Run VS or unswitchedRetention time 25 ms non-volatile memoryConnection type Plug 4-pin, M12 Plug 5-pin, M12VDE protection class6) V Enclosure rating IP 67Circuit protection7) A, B, CAmbient temperature TA

Operation –10 ... +55 °C Storage –25 ... +75 °CShock load To IEC 68 Weight Approx. 400 gHousing Cast zinc

KT5W-2_ _ _6

Scanning distance 40 mm 3

Scanning distance 20 mm 2

Scanning distance 10 mm 1

Scanning distance

1

3

2

(mm) 10 20 30 40 50

100

90

80

70

60

50

40

30

20

10

0Rela

tive

sens

itivi

ty in

% *) Further types on request

KT5W-2B1116 1043006