Download - 02_UPA 150S-34
-
7/27/2019 02_UPA 150S-34
1/2
50 Hz UPA 150S
42
UPA 150S - 34 for Well Diameters of 150 mm (6 inches) and above
Pumps with submersible motors for ... - Type of current / voltage three-phase (3~) / 400 V. . . . . . . . . . . . . . . . . . . . . . . . . . .- Starting d.o.l. (D) or star-delta (Y-$&. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pump + motor Pump Motor Motor lead 2), flat
Dischargehead
Q = 0 m 3 /h
Ratedpower
Max. temperatureof the fluid pumped
v 0.2 m/s (= 0 m/s)
Ratedcurrent
Effi-ciency
Powerfactor
Number x cross-section ofconductors (use under water,
400 V and +30 C)
UPA 150S - 34 / .. + ...H0m
P NkW
Tmax 1)C
INA
M%
cos- - -
D.o.l.mm 2
Y- 5)mm 2
1 + DN 100-1.1 13.2 1.1 30 (30) 3.1 73.5 0.71 4 x 1.5 - -
2 + DN 100-2.2 26 2.2 30 (30) 5.7 75.0 0.75 4 x 1.5 - -
3 + DN 100-3.7 39.5 3.7 30 (30) 8.7 77.5 0.80 4 x 1.5 - -
4 + DN 100-5.5 6) 54 5.5 30 (30) 13.0 76.5 0.80 4 x 1.5 - -
5 + DN 100-5.5 6) 67 5.5 30 (30) 13.0 76.5 0.80 4 x 1.5 - -
6 + UMA 150D 7/21 81 6.5 36 (32) 15.3 77.5 0.79 4 x 2.5 3/4 x 2.5
6 + DN 150-7.5 80 7.5 30 (30) 16.0 79.0 0.86 4 x 4.0 4/4 x 4.0
7 + UMA 150D 7/21 93 7.5 32 (26) 17.2 76.5 0.82 4 x 2.5 3/4 x 2.5
7 + DN 150-7.5 92 7.5 30 (30) 16.0 79.0 0.86 4 x 4.0 4/4 x 4.0
8 + UMA 150D 9/21 107 9.0 33 (27) 20.1 78.0 0.83 4 x 2.5 3/4 x 2.5
8 + DN 150-9.3 107 9.3 30 (30) 20.7 81.0 0.80 4 x 4.0 4/4 x 4.0
9 + UMA 150D 9/21 120 9.3 28 (22) 20.7 78.0 0.83 4 x 2.5 3/4 x 2.5
9 + DN 150-9.3 119 9.3 30 (30) 20.7 81.0 0.80 4 x 4.0 4/4 x 4.0
10 + UMA 150D 13/21 136 11.0 35 (30) 25.2 81.0 0.78 4 x 2.5 3/4 x 2.5
10 + DN 150-11 132 11.0 30 (30) 23.1 81.0 0.85 4 x 4.0 4/4 x 4.0
11 + UMA 150D 13/21 149 12.0 32 (27) 26.8 80.5 0.80 4 x 2.5 3/4 x 2.5
11 + DN 150-15 148 15.0 30 (30) 31.2 81.0 0.86 4 x 4.0 4/4 x 4.0
12 + UMA 150D 13/21 161 13.0 30 (24) 28.6 80.5 0.82 4 x 2.5 3/4 x 2.5
12 + DN 150-15 161 15.0 30 (30) 31.2 81.0 0.86 4 x 4.0 4/4 x 4.0
14 + UMA 150D 15/21 187 15.0 30 (24) 32.0 81.5 0.83 4 x 4.0 3/4 x 2.5
14 + DN 150-15 185 15.0 30 (30) 31.2 81.0 0.86 4 x 4.0 4/4 x 4.0
17 + UMA 150D 18/21 228 18.5 28 (21) 40.0 82.0 0.82 4 x 4.0 3/4 x 2.5
17 + DN 150-18.5 224 18.5 30 (30) 38.3 82.0 0.85 4 x 4.0 4/4 x 4.0
19 + UMA 150D 22/21 256 21.0 32 (26) 45.0 83.5 0.81 4 x 4.0 3/4 x 2.5
19 + DN 150-22 253 22.0 30 (30) 44.6 83.0 0.86 4 x 4.0 4/4 x 4.0
21 + UMA 150D 22/21 281 22.0 29 (22) 46.9 83.5 0.81 4 x 4.0 3/4 x 2.5
21 + DN 150-22 277 22.0 30 (30) 44.6 83.0 0.86 4 x 4.0 4/4 x 4.01) Also see pages 3 and 35. 2) 3/4 = 1 x 3-core + 1 x 4-core, 90 spacing. 5) Motors DN 100 for d.o.l. starting only .6) With UMA 150D motors on request.
Dimensions / Weights / Horizontal Installation 1)LP LA mm m A in kg D max in mm Installation 2) A
mmStandard Special Standard Special D.o.l. Y- $
mm
UPA150S - 34/ .. UMA DN UMA DN UMA DN UMA DN UMA DN UMA12345
495495605715825
-----
795850
116014201530
-----
795850
116014201530
-----
2226384446
-----
2327394547
143143143143143
-----
-----
v + hv + hv + hv + hv + h
560590800985
1095
6789
10
9701080119013001410
16901800194020502240
16201730187019802125
17001810195020602250
-----
6971757785
6264687074
7173777988
-----
147147147147147
149149149149149
v + hv + hv + hv + hv + h
vvvvv
12451355148015901740
1112141719
21
15201630185021802400
2620
23502460272531003410
3630
23002410263030253310
3530
23602470273531103420
3640
-----
-
909299
108119
123
848689
101111
114
9294
101110122
125
-----
-
147147147147147
147
149149149149149
149
v + hv + h
vvv
v
vvvvv
v
18501960
---
-1) Including check valve with threaded end and standard motor leads.2) v = vertical and h = horizontal.
-
7/27/2019 02_UPA 150S-34
2/2
UPA 150S - 34 /..(Tolerances toISO 9906 Class 2 / Annex A)
Operating range:
Qmin = 7 m 3 /hQmax = End of characteristic curve
UPA 150S50 Hz
43
UPA 150S - 34 / ..
SelectionThe pressure losses H v in the check valve are notconsidered in the pump characteristic curves.For more details and a selection example refer topage 8.Legend ...Hv : Head losses in the check valve' p: Pump efficiency
(not considering check valve)NPSH: Net positive suction head
required by the pump
Pump End G 3 / DN 80The information given below is based on themodel with check valve / connection branch andthreaded end.The outside diameter D max on flanged end models (available with adapter) is as follows:Flanged end DN 80: D max = 200 mmThreaded end to DIN ISO 228, Part 1.Flange mating dimensions to DIN EN 1092-2.