TRIC Training Log: 07-22-04
Client: Salinas Brothers, Oxnard, CAJob: Residence, to front property line, replacing 4”
VCPPull: uphill / 45’ / 4” / SDR17
2004-0722CA
technical archives
www.trictrenchless.com
We at TRIC Tools have specific requirements for the use and maintenance of our equipment with regard to safety and
efficiency on the job. Our written and verbal recommendations coincide with safety regulations set by
local, state, and national government agencies. Our clients may have standards over and above industry regulations. However, the safety equipment, apparel, and operating
procedures demonstrated by our clients in this presentation may or may not comply with above mentioned government
regulations.
2004-0722CA
technical archives
www.trictrenchless.com
Pulling hole: A hole roughly 2’ wide by 4’ long allows easy use of the extender cage.
Smaller (shorter) holes require wood cribbing to complete the pull.
2004-0722CA
technical archives
www.trictrenchless.com
Pipe length: Allow enough extra for “bumping” new pipe with a sledge hammer at the end of the pull. This usually means between 5’ and 10’ more than the length of pipe
being replaced.
2004-0722CA
technical archives
www.trictrenchless.com
Trimming the pipe: Carefully check alignment in the jig before and after trimming.
2004-0722CA
technical archives
www.trictrenchless.com
Keep it clean: Remove trimmings after each use of the blade, so as not to interfere with heating or fusing. This is especially true of the smaller jig (shown
here).
2004-0722CA
technical archives
www.trictrenchless.com
Heating the pipe: Make firm, even contact with heating iron, then use neutral pressure. Fusing time and temperatures are also affected by weather.
2004-0722CA
technical archives
www.trictrenchless.com
Fusing the head: Depending on the length of the pull, the end where the head is attached can make a big difference in convenience of entry.
2004-0722CA
technical archives
www.trictrenchless.com
Property line: Clearing pipe from the entry hole, which in this case is downstream.
2004-0722CA
technical archives
www.trictrenchless.com
Cable ready: Attaching the pulling head to the cable.
2004-0722CA
technical archives
www.trictrenchless.com
Ready to go: Interference with traffic (pedestrian and automotive) is usually minimal.
2004-0722CA
technical archives
www.trictrenchless.com
A good start: Guide the head into its entry point to assure the best angle of attack.
2004-0722CA
technical archives
www.trictrenchless.com
Steady progress: Watching a good entry.
2004-0722CA
technical archives
www.trictrenchless.com
Go with the bend: Note how the cable clevis and head core “hinge” on the clevis pin.
2004-0722CA
technical archives
www.trictrenchless.com
Least resistance: Strive for a clean , direct, and unobstructed entry.
2004-0722CA
technical archives
www.trictrenchless.com
Traffic control: After assisting optimal entry angle, and after 4 or 5 feet of pull, pipe can be flexed back to a tighter arc to keep it out of the public right-of-
way.
2004-0722CA
technical archives
www.trictrenchless.com
Watching the pressure: Whether the pull is 30 feet or 300 feet, the pressure gauge is an indispensable trouble shooter.
2004-0722CA
technical archives
www.trictrenchless.com
Simple and versatile: Ram can swivel 360º on pulley base, and pulley can operate at various angles against resistance plate.
2004-0722CA
technical archives
www.trictrenchless.com
Detensioning: Removing tension O-rings at end of pull to facilitate release of jaws.
2004-0722CA
technical archives
www.trictrenchless.com
Extender cage: For that all-important last foot.
2004-0722CA
technical archives
www.trictrenchless.com
Almost there: Keep debris away from pulley assembly to allow clear vision of pulley and cable terminator.
2004-0722CA
technical archives
www.trictrenchless.com
Arrival: Stop when clevis (cable terminator) is just visible inside pulley housing.Keep clevis sheath away from pulley wheel.