HESP
HESP
G 1"1/4 (33x42)
CGAX - CXAX035 - 040 - 046 - 052 - 060
57351392 Sheet 1 of 4Date: Revision: C
08-JUN-2015
H1 H2 H3 H4
CGAX 035 ... 060CXAX 035 ... 052
SN1417
15241747
1854LN 1747 2077
CXAX 060SN
16171724
19472054
LN 1947 2277
3" OD ( 76,1mm)VICTAULIC ®1 2
DETAIL A
3 4
A
6
21
4
3
5
14
2
3
12
4
3
1
2
3
4
1 2 3
5 5
RELEASED 29/Jun/2015 06:20:06 GMT
47 2142 47
38
2160
38
15
(2236)
(2236)
CGAX - CXAX035 - 040 - 046 - 052 - 060
57351392 Sheet 2 of 4Date: Revision: C
08-JUN-2015
kg ( 5%)
TOTAL
CHARGE PAR POINTS - PUNKLASTEN - POINT LOADCARICHI PUNTUALI - PUNTBELASTINGPESOS EN LOS PUNTOS DE SOPORTE
1 2 3 4
CGAX
035 887 287 254 150 196040 973 296 306 182 190046 983 300 311 182 190052 1004 300 325 180 199060 1029 311 337 181 200035 981 293 289 201 198040 1067 322 321 213 212046 1081 327 324 214 216052 1098 327 340 211 220060 1123 311 377 239 196035 1849 507 503 421 417040 1936 537 534 433 431046 1946 541 538 434 433052 1967 541 554 431 441060 1992 551 565 433 443
CXAX
035 974 295 300 188 192040 1072 330 336 201 205046 1072 330 336 201 205052 1093 309 370 230 184060 1163 357 367 217 222035 1068 322 313 220 214040 1166 357 348 233 229046 1166 357 348 233 229052 1187 363 357 234 232060 1257 385 379 248 245035 1936 535 527 439 434040 2034 570 562 454 448046 2034 570 562 454 448052 2056 576 571 456 453060 2127 600 594 468 464
1
2
3
4
5
B
DETAIL B
1
2
3
1
2
3
RELEASED 29/Jun/2015 06:20:06 GMT
A
A
121
219
5025
30
CGAX - CXAX035 - 040 - 046 - 052 - 060
57351392 Sheet 3 of 4Date: Revision: C
08-JUN-2015
8
1x Ø461x Ø29
1x Ø461x Ø29
# 250A : S max : 150mm²
L1 L2 L3
PE
5 9
7 7
10
11
2x Ø46
6x ISO202x ISO25
7
7
SECTION A-A
12
Ø11
Ø8
8
6
RELEASED 29/Jun/2015 06:20:06 GMT
CGAX - CXAX035 - 040 - 046 - 052 - 060
TEIL-WÄRMERÜCKGEWINNUNGWASSER-EINTRITTSANSCHLUSS
(OPTION)
CONEXIÓN DE ENTRADA DEAGUA RECUPERACIÓN DE
CALOR PARCIAL (OPCIONAL)TEIL-WÄRMERÜCKGEWINNUNG
WASSER-AUSTRITTSANSCHLUSS(OPTION)
WATER UITTREDE AANSLUITINGGEDEELTELIJKE WARMTETE-
RUGWINNING (OPTIE)
CONEXIÓN DE SALIDA DEAGUA RECUPERACIÓN DE
CALOR PARCIAL (OPCIONAL)
57351392 Sheet 4 of 4Date: Revision: C
08-JUN-2015
FRANCAIS DEUTSCH ENGLISH ITALIANO NEDERLANDS ESPANOL
CONNEXION ENTREE EAUEVAPORATEUR
VERDAMPFER WASSER-EINTRITTSANSCHLUSS
EVAPORATOR WATERINLET CONNECTION
RACCORDO ENTRATAACQUA EVAPORATORE
VERDAMPER WATER INTREDE AANSLUITING
CONEXIÓN DE ENTRADADE AGUA DEL EVAPORADOR
CONNEXION SORTIE EAUEVAPORATEUR
VERDAMPFER WASSER-AUSTRITTSANSCHLUSS
EVAPORATOR WATEROUTLET CONNECTION
RACCORDO USCITAACQUA EVAPORATORE
VERDAMPER WATERUITTREDE AANSLUITING
CONEXIÓN DE SALIDADE AGUA DEL EVAPORADOR
CONNEXION ENTREE EAURECUPERATION PARTIELLE
DE CHALEUR (OPTION)
PARTIAL HEAT RECOVERYWATER INLET CONNECTION
(OPTION)
COLLEGAMENTO INGRESSOACQUA RECUPERO PARZIALE
DI CALORE(OPZIONE )
WATER INTREDE AANSLUITINGGEDEELTELIJKE WARMTETE-
RUGWINNING (OPTIE)CONNEXION SORTIE EAU
RECUPERATION PARTIELLEDE CHALEUR (OPTION)
PARTIAL HEAT RECOVERYWATER OUTLET CONNECTION
(OPTION)
COLLEGAMENTO USCITAACQUA RECUPERO PARZIALE
DI CALORE(OPZIONE )
COFFRET ELECTRIQUE STEUERTAFEL CONTROL PANEL PANNELLO DI CONTROLLO BEDIENINGSPANEEL PANEL DE CONTROL
AIRE NECESSAIRE POURENTREE D'AIR ET
MAINTENANCE
MINDESTABSTAND(LUFTEINTRITT
UND WARTUNG)
MINIMUM CLEARANCE(AIR ENTERING AND
MAINTENANCE)
SPAZIO MINIMO(ARIA IN ENTRATAE MANUTENZIONE)
MINIMUM VRIJE RUIMTE(LUCHT AANVOEREN ONDERHOUD)
ESPACIO MÍNIMO(PARA LA ENTRADA DE AIRE
Y EL MANTENIMIENTO)
ACCES RACCORDEMENTELECTRIQUE
STROMVERSORGUNGS-EINLASS POWER SUPPLY INLET INGRESSO ALIMENTAZIONE VOEDINGSKABEL
INVOEROPENINGENTRADA DE
ALIMENTACIÓN ELÉCTRICA
INTERRUPTEUR / SECTIONNEUR TRENNSCHALTER DISCONNECT SWITCH SEZIONATORE HOOFDSCHAKELAAR SECCIONADOR GENERAL
AFFICHEUR DISPLAY DISPLAY DISPLAY DISPLAY PANTALLA
MODULES DE CONTROLEUNITE STANDARD HAUPTPROZESSORMODUL MAIN PROCESSOR
MODULEMODULO PROCESSORE
PRINCIPALEHOOFD PROCESSOR
MODULEMÓDULO DEL
PROCESADOR PRINCIPAL
MODULE CONTROLE CLIENT
(OPTION)
HILFSMODULKUNDENSTEUERUNG
(OPTION)
AUXILIARY MODULE CUSTOMER CONTROL
(OPTION)
CONTROLLO CLIENTEMODULO AUSILIARIO
(OPZIONE)HULP MODULE KLANTSTURINGEN (OPTIE)
MÓDULO AUXILIAR DECONTROL DEL CLIENTE
(OPCIÓN)MODULE
CHAUFFAGE AUXILIAIRE(OPTION)
HILFSMODULZUSATZHEIZUNG (OPTION)
AUXILIARY MODULE SUPPLEMENTAL HEAT
(OPTION)
CALORE SUPPLEMENTAREMODULO AUSILIARIO
(OPZIONE)
HULP MODULEAANVULLENDE
VERWARMING (OPTIE)
MÓDULO AUXILIARDE CALEFACCIÓN
SUPLEMENTARIA (OPCIÓN)
UNITE STANDARD GRUNDGERÄT STANDARD UNIT UNITÀ BASE BASIS MODEL UNIDAD BÁSICA
UNITE AVEC MODULEHYDRAULIQUE
GERÄT MIT PUMPEN-SPEICHER-EINHEIT
UNIT WITH HYDRAULICMODULE
UNITÀ CON MODULOIDRAULICO
UITVOERING METHYDRAULISCHE MODULE
UNIDAD CON MÓDULOHIDRÁULICO
UNITE AVEC MODULEHYDRAULIQUE
ET BALLON TAMPON
GERÄT MIT PUMPEN-SPEICHER-EINHEIT
UND PUFFERSPEICHER
UNIT WITH HYDRAULICMODULE
AND BUFFER TANK
UNITÀ CON MODULOIDRAULICO E SERBATOIO
D'ACCUMULO
UITVOERING METHYDRAULISCHE MODULE
EN BUFFERVAT
UNIDAD CON MÓDULOHIDRÁULICO Y
DEPÓSITO DE INERCIA
NON MONTES SURCGAX-CXAX 035
NICHT INSTALLIERT ANCGAX-CXAX 035
NOT MOUNTED ONCGAX-CXAX 035
NON MONTATO SUCGAX-CXAX 035
NIET GEMONTEERD OP DECGAX-CXAX 035
MONTAJE NO REALIZADOEN EL CGAX-CXAX 035
RACCORD ET TUBE LISSE(OPTION)
KUPPLUNG UNDGLATTE LEITUNG
(OPTION)COUPLING AND
SMOOTH PIPE (OPTION)RACCORDO E TUBO LISCIO
(OPZIONE)GLAD PIJPSTUK
EN KOPPELING (OPTIE)ACOPLAMIENTO Y TUBO
LISO (OPCIÓN)
CHEMINEMENT CABLE PUISSANCE CLIENT
VERLEGEN DERNETZKABEL, BAUSEITIG
ROUTING POWER CABLESCUSTOMER
INSTRADAMENTO DEI CAVIDI ALIMENTAZIONE
DEL CLIENTEVOEDINGSKABEL LOOP
KLANTENRUTAMIENTO DE LOS
CABLES DE ALIMENTACIÓN,CLIENTE
1
2
3
4
5
6
7
8
9
11
1
2
3
4
5
6
7
8
9
10
11
12
10
12
1
2
3
4
5
6