Transcript
  • 7/25/2019 6SL3224 0XE42 0UA0 Datasheet En

    1/2

    6SL3224-0XE42-0UA0

    Data sheet for SINAMICS Power Module PM240

    Ordering data

    Figure similar

    Rated data

    Ambient conditions

    General tech. specifications

    Input

    Output

    Ambient temperature

    Relative humidity

    Number of phases

    Max. operation

    Storage

    Transport

    Operation LO

    Cooling air requirement

    Cooling

    Installation altitude

    Rated power (LO)

    Rated voltage

    Number of phases

    Line voltage

    Line frequency

    Rated current with line reactor

    Rated current without line reactor

    Rated power (HO)

    Power factor

    Offset factor cos

    Sound pressure level (1m)

    Power loss

    Rated current (LO)

    Pulse frequency

    Rated current (HO)

    Max. output current

    Output frequency for V/f control

    Overload capability

    Output frequency for vector control

    200.00 kW / 300.00 hp

    250.00 kW / 400.00 hp

    400 V

    2 kHz

    0.95

    69 dB

    5.50 kW

    477.00 A

    370.00 A

    592.00 A

    442.00 A

    354.00 A

    0.360 m/s

    1000 m

    Internal air cooling

    1.1 output current rating (i.e., 110 % overload) for 57 s with a cycle t ime of 300 s 1.5 output current rating (i.e., 150 % overload) for 3 s with a cycle time of 300 s

    Consignment no. :

    Remarks :

    Item no. :

    Offer no. :Order no. :

    Project :

    Client order no. :

    1.36 output current rating (i.e., 136% overload) for 57 s with a cycle time of 300 s 1.6 output current rating (i.e., 160% overload) for 3 s with a cycle time of 300 s

    3 AC

    3 AC

    380 ... 480 V 10 %

    47 ... 63 Hz

    0 ... 200 Hz

    0 ... 550 Hz95 % RH, condensation not permitted

    -25 ... 55 C (-13 ... 131 F)

    -40 ... 70 C (-40 ... 158 F)

    0 ... 40 C (32 ... 104 F)

    0.85

    High Overload (HO)

    Low Overload (LO)

    Operation HO 0 ... 40 C (32 ... 104 F)

    Efficiency 0.98

    Technical data are subject to change! There may be discrepancies between calculated and rating plate values.Generated Sat Feb 20 23:58:00 CET 2016Page 1 of2

  • 7/25/2019 6SL3224 0XE42 0UA0 Datasheet En

    2/2

    6SL3224-0XE42-0UA0

    Data sheet for SINAMICS Power Module PM240

    Ordering data

    Figure similar

    Compliance with standards

    CE marking

    Standards

    According to low-voltage directive2006/95/EC

    UL, cUL, CE, C-Tick (RCM), SEMI F47

    Mechanical data

    547.0 mm

    Degree of protection IP20

    326.0 mm

    Height

    Net weight 174.00 kg

    Depth

    Size

    Width

    1533.0 mm

    FSGX

    M10 bolt

    Version

    Unshielded 300 m

    Version

    185.00 ... 240.00 mm

    Max. motor cable length

    Conductor cross-section

    Connections

    M10 bolt

    Motor end

    200 m

    Line side

    Conductor cross-section

    185.00 ... 240.00 mm

    Shielded

    Converter losses to EN 50598-2*

    Comparison with the reference converter (90% /100%)

    Efficiency class

    -58.01 %

    IE2

    3000.7 W (0.91 %)

    5731.3 W (1.73 %)

    f

    4703.0 W (1.42 %)

    25%

    100%

    2655.1 W (0.80 %)

    4037.3 W (1.22 %)

    1868.1 W (0.57 %)

    50%

    1978 W (0.60 %)

    50%2401.0 W (0.73 %)

    90%

    I

    The diagram shows the losses for the points (as per standard EN 50598) of the relative torque

    generating current (I) over the relative motor stator frequency(f). The values are valid for the basic

    version of the converter without options/components.

    The percentage values show the losses in relation to the rated apparent power of the converter.

    *calculated values; increased by 10% according to the standard

    Technical data are subject to change! There may be discrepancies between calculated and rating plate values.Generated Sat Feb 20 23:58:00 CET 2016Page 2 of2