Download - Aac Aaac Acsr & Aacsr
8/6/2019 Aac Aaac Acsr & Aacsr
http://slidepdf.com/reader/full/aac-aaac-acsr-aacsr 1/8D-1
AAC,AAAC,ACSR & AACSR
Operation circumstancesContinuous operating temperature should be less than 70
Installing temperature should not be lower than -20
Allowed bending diameter should be larger than 12 times of
the diameter for the product itself.
Over load operating is strictly forbidden.
Install method
Stock & transportation requirements
Model,name,product sizes and standards
Model,name,product sizes and standards
Name standardsProduct sizes (mm2)model No.
Copper core PVC insulated wire
Aluminum core PVC insulated wire
Copper core PVC insulated PVC sheathed flat wire
Aluminum core PVC insulated PVC sheathed flat wire
1.5 mm2-185 mm2
2.5 mm2-185 mm2
2x1.5 mm2-3x10 mm2
GB5023-1997
JB8734-19982x1.5 mm2-3x10 mm2
BV
BLV
BVVB
BLVVB
Main applications
Overhead lines of medium, high, and very high voltage.
Name standardsProduct sizes (mm2
)Model No.
Aluminum alloy stranded conductor steel reinforced
(anticorrosive)
Aluminum Steel reinforced (anticorrosive)
Aluminum alloy stranded conductor steel reinforced
(anticorrosive)
16-800
16-800
DIN
48201/48204/48206
IEC 1089
GB1179-83/1129,
1129-83,9392-8816-800
ACCSR
ACSR (F)
ACCSR (F)
PVC INSULATED WIRE
Operation circumstances
Uo/U is 450/750V or 300/500V.
Installing temperature should not be lower than 0 . Allowed bending diameter should be larger than 4 times of the
product.
Main applications
Lines of AC 450/750V for motivation device, daily used electrical
appliances, instruments and telecommunication applications.
All aluminum stranded conductor
All aluminum alloy stranded conductor
Aluminum stranded conductor steel reinforced
16-800
16-800
ASTM
B231/B232/B339/B711
BS 215/324216-800
AAC
AAAC
ACSR
8/6/2019 Aac Aaac Acsr & Aacsr
http://slidepdf.com/reader/full/aac-aaac-acsr-aacsr 2/8D-2
overhead power cable pvc/pe insulated
operation circumstances
Rated voltages Uo/ U is 0.3/1KV or 10/12KV or 35/42KV.
Continuous operating temperatuer should be less than 70 .
Installing temperature should not be lower than -20 .
Allowed bending diameter should be 12 times of the product diameter.
Main applications
Overhead line for fixed installation and in/out line.
Model,name,product sizes and standards
Name standardsProduct sizes (mm2)Model
Copper core PVC insulated overhead cable
ALuminum core PVC insulated overhead cable
Al. alloy core PVC insulated overhead cable
ACSR core PVC insulated overhead cable
Copper core PE insulated overhead cable
Aluminum core PE insulated overhead cable
10-240
10-240
25-240
10-240 GB12527-90 for 0.6/1KV
GB14049-93 for 10/12KV
and 35/42KV
10-240
10-240
JKY
JKLV
JKLHV
JKLGV
JKY
JKLY
Al. al loy core PE insulated overhead cable 10-240JKLHY
ACSR core PE insulated overhead cable 25-240JKLGY
Aluminum core PE insulated overhead cable 10-240JKLY/Q
Al. al loy core PE insulated overhead cable 10-240JKLHY/Q
ACSR core PE insulated overhead cable 25-240JKLGY/Q
8/6/2019 Aac Aaac Acsr & Aacsr
http://slidepdf.com/reader/full/aac-aaac-acsr-aacsr 3/8D-3
PLASTIC CONTROL CABLES
COMMUNICATION CABLES
Main performance
Brief product introduction
The rated voltage 450/750V PVC and 0.6/1KV XLPE control cable are used for the
controlling, return circuit and protecting facilities for the rated voltage 450/750V and0.6/1KV or below separately. The working temperature of PVC and XLPE control
cable are 70 and 90 separately.
Our factory developes 0.6/1KV XLPE insulated control cable based on PVC insu-
lated and sheathed control cable. and 450/750V PVC insulated control cables are in
accordance with the GB9330. 0.6/1KV XLPE insulated control cable meets the re-
lated criterions of IEC60502.1 The electrical properties of flame retardant and fire
resistant control cables are in accordance with GB9330 on plastic insulated control
cable. The property of flame retardant meets the requirements of class A, B or C of
GB/T12666.5 about test on bunched wires or cable correspondingly. The property
of fire resistant meets the class A or B requirements of the GB/T12666.6 test on fire
resisting characteristics of wire or cable.
When at 20 the conductor resistance should conform to the standard GB/T3956.
The finished cable should withstand the power frequent test voltage of 3kv for 5min
and does not breakdown.
Application
It’s widely used for telephone trunk line, of exchange zone jointing line shelf, switch-
board & the machines in the switchboard, short distance wiring of wire network
used for telecommunication circuit in the cities, towns, villages, enterprises, etc.
The self-supporting aerial cable type HYAC,HYFAC,HYPAC,HYATC,HYATC,
HYPATC and screened core cable (PCM) as well as steel tape armoured and
steel wire armoured cable may be manufactured at the request of customers.
Types and
Type Discription
HYA Copper conductor solid polyolefine insulated unfilled
communication cable with alpeth sheath
HYFA Copper conductor foam polyolefine insulated unfilled
communication cable with alpeth sheath
HYPA Copper conductor foam-skin polyolefine insulated unfilledcommunication cable with alpeth sheath
HYATCopper conductor solid polyolefine insulated filled
communication cable with alpeth sheath
HYFATCopper conductor foam polyolefine insulated filled
communication cable with alpeth sheath
HYVCopper conductor polythene insulated communication cable
with sheath
HYPATCopper conductor foam-skin polyolefine insulated filled
communication cable with alpeth sheath
8/6/2019 Aac Aaac Acsr & Aacsr
http://slidepdf.com/reader/full/aac-aaac-acsr-aacsr 4/8D-4
EARTHWIRE/STAY WIRE
Galvanised steel wire in mild steel, medium carbon and high carbon steel are
available with Eritech as individual wires & also in stranded forms. Individual
wires are supplied in each coil weighing 70 to 135 kg or as prescribed by the
customer.
Stranded wire are produced as-
1) Overhead Groundwire or static wire for earthing of the electrical Power
Transmission lines.
2) Stay or Guy wire strands are produced for use with poles, towers or anyother
form of guying and can be used for telephone, power & CATV sets.
Stranded wires are packed in steel drums if required by the customer, other-
wise in coils wrapped and palletised for eqports.
These wires are available as per ASTM-A-475 & BS-183 specification.
8/6/2019 Aac Aaac Acsr & Aacsr
http://slidepdf.com/reader/full/aac-aaac-acsr-aacsr 5/8D-5
Construction
Number of wires/
wire diameter
Approximate strand
diameter Grade 350
kg/km
Minimum breaking load of strand
Grade 480 Grade 700 Grade 850 Grade 1000 Grade 1150 Grade 1300
Approx.
weitht
m m k N k N k N k N k N k N k N
3/1.80
3/2.65
3/3.25
3/4.00
4/1.80
4/2.65
4/3.25
4/4.00
5/1.50
5/1.85
5/2.65
5/3.25
5/4.00
7/0.56
7/0.71
7/0.85
7/0.90
7/1.00
7/1.25
7/1.40
7/RS++
7/1.60
7/1.80
7/2.00
7/2.36
7/2.65
7/3.00
7/3.15
7/3.25
7/3.65
7/4.00
7/4.25
7/4.75
19/1.00
19/1.25
19/1.40
19/1.60
19/2.00
19/2.50
19/3.00
19/3.55
19/4.00
19/4.75
3.9
5.7
7.0
8.6
4.4
6.4
7.9
9.7
4.1
4.9
7.2
8.8
10.8
1.7
2.1
2.6
2.7
3.0
3.8
4.2
4.3
4.8
5.4
6.0
7.1
8.0
9.0
9.5
9.8
11.0
12.0
12.8
14.0
5.0
6.3
7.0
8.0
10.0
12.5
15.0
17.8
20.0
23.8
2.65
5.80
8.70
13.20
3.55
7.70
11.60
17.60
3.10
4.45
9.65
14.50
22.00
0.360
0.97
1.39
1.55
1.92
3.01
3.75
3.85
4.90
6.23
7.70
10.70
13.50
17.30
19.10
20.30
25.60
30.90
34.75
43.40
5.22
8.16
10.24
13.37
20.90
32.65
47.00
65.80
83.55
117.85
3.66
7.95
11.95
18.10
4.90
10.60
15.90
24.10
4.24
6.10
13.25
19.90
30.15
0.83
1.33
1.90
2.14
2.64
4.10
5.17
5.28
6.75
8.55
10.55
14.70
18.50
23.75
26.20
27.85
35.15
42.20
47.65
59.45
7.16
11.19
14.04
18.34
28.65
44.80
64.50
90.27
114.6
161.6
-
-
-
-
-
-
-
35.20
6.18
8.90
19.30
29.00
43.95
1.20
1.94
2.80
3.1
3.85
6.00
7.54
7.70
9.85
12.45
15.40
21.40
27.00
34.65
38.20
40.65
51.25
61.60
69.50
86.80
10.45
16.32
20.47
26.75
41.78
65.29
94.00
131.6
167.1
235.7
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
9.16
9.35
11.95
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
50.74
79.28
114.1
159.9
203.0
286.0
-
-
-
-
-
-
-
-
-
-
-
-
-
1.70
2.75
3.95
4.45
5.50
8.55
10.75
11.00
14.10
17.80
22.00
30.60
38.60
49.50
54.55
58.05
73.25
88.00
99.30
124.0
14.92
23.32
29.25
38.20
59.69
93.27
134.3
188.0
238.7
336.7
-
-
-
-
-
-
-
-
-
-
-
-
-
1.98
3.19
4.57
5.12
6.32
9.88
12.35
12.65
16.20
20.50
25.30
35.20
44.40
56.90
62.75
66.80
84.20
101.0
114.0
142.7
17.16
26.81
33.64
43.93
68.64
107.3
154.5
216.3
274.6
387.2
-
-
-
-
-
-
-
-
-
-
-
-
-
2.24
3.60
5.15
5.80
7.15
11.15
14.00
14.30
18.30
23.20
28.60
39.80
50.20
64.30
70.90
75.50
95.20
114.00
129.00
161.3
19.40
30.31
38.02
49.66
77.60
121.3
174.6
244.5
310.4
437.7
60
130
195
295
80
172
260
390
69
95
220
320
490
14
28
31
35
43
67
84
86
110
140
170
240
300
392
430
460
570
690
780
970
120
180
230
300
470
730
1050
1470
1870
2630
EARTHWIER/STAY WIRE
BS:183 Specn
8/6/2019 Aac Aaac Acsr & Aacsr
http://slidepdf.com/reader/full/aac-aaac-acsr-aacsr 6/8D-6
Construction
Number of wires/
wire diameter
Approximate strand
diameter
kg/km
Simens Martin
GradeApprox. weitht
(inch) k N k N k N
3/2.64
3/3.05
3/3.05
3/3.30
3/3.68
3/4.19
7/1.04
7/1.32
7/1.57
7/1.65
7/1.83
7/2.03
7/2.36
7/2.64
7/2.77
7/3.05
7/3.68
7/4.19
7/4.78
7/5.26
19/2.54
19/2.87
19/3.18
19/3.81
19/4.50
19/5.08
37/3.63
37/4.09
37/4.55
m m
High Strength
Grade
Extra-High Strength
Grade
7/32
1/4
1/4
9/32
5/16
3/8
1/8
5/32
3/16
3/16
7/32
1/4
9/32
5/16
5/16
3/8
7/16
1/2
9/16
5/8
1/2
9/16
5/8
3/4
7/8
1
1
11.8
11/4
5.56
6.35
6.35
7.14
7.94
9.25
3.18
3.97
4.76
4.76
5.56
6.35
7.14
7.94
7.94
9.25
11.11
12.70
14.29
15.88
12.70
12.49
15.88
19.05
22.22
25.40
25.40
28.58
31.75
10.409
13.523
-
15.035
18.193
24.732
4.048
6.539
8.452
11.387
14.012
18.905
23.798
-
30.915
41.591
53.823
69.837
84.961
54.492
71.616
80.513
116.543
159.691
209.066
205.508
262.000
324.720
15.569
21.040
-
23.398
28.246
37.187
5.916
9.519
12.677
17.126
21.129
28.469
35.583
-
48.040
65.499
83.627
108.981
131.677
84.961
107.202
124.995
181.487
248.211
325.610
319.827
407.457
505.318
21.796
29.981
-
33.362
40.479
52.489
8.140
13.078
17.748
24.020
29.581
39.812
49.820
-
68.503
92.523
119.657
155.688
188.605
118.768
149.905
178.819
259.331
354.523
464.839
456.832
581.827
721.502
131
174
174
204
256
328
49
76
108
118
145
181
243
305
335
407
594
768
991
1211
751
948
1184
1719
2352
2384
3061
4006
4833
EARTHWIER/STAY WIRE ASTM:A-475 Specn
7 WIRE STARND
19 WIRE STARND
19 WIRE GLAVANIZED STEEL STRAND
GUY, MESSNGER STRAND & WIRE
8/6/2019 Aac Aaac Acsr & Aacsr
http://slidepdf.com/reader/full/aac-aaac-acsr-aacsr 7/8D-7
Clipped to a
surface or on a
cable traybunched &
unenclosed two
cables single
phase at 35
Current Rating
m m m m Kg/Km
1.0 re
1.5 re
1.5 rm
2.5 re
2.5 rm
4.0 rm
6.0 rm
10 rm
16 rm
16 rm
25 rm
25 rm
35 rm
50 rm
70 rm
95 rm
120 rm
150 rm
185 rm
240 rm
300 rm
400 rm
500 rm
m mm m2
Bunched and
enclosed in
conduit two cablesSingle phase at
35
Approx.
Weight
Approx.
overall
diameter
Nominal
thickness of
insulation
No. and
nominal
diameter of wires
Nominal
cross
sectionalarea of
conductor
Amp Amp
1/1.13
1/1.38
7/0.50
1/1.78
7/0.67
7/0.85
7/1.04
7/1.35
7/1.70
19/1.01
7/2.14
19/1.30
19/1.53
19/1.78
19/2.14
19/2.52
37/2.03
37/2.25
37/2.52
61/2.25
61/2.52
61/2.85
61/3.20
0.7
0.7
0.7
0.8
0.8
0.8
0.8
1.0
1.0
1.0
1.2
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2
2.4
2.6
2.8
2.8
3.3
3.5
3.9
4.2
4.8
5.4
6.8
8.0
8.1
9.8
9.9
11.0
13.0
15.0
17.0
19.0
21.0
23.5
26.5
29.5
33.5
37.0
17
22
23
35
35
35
75
115
178
180
280
280
390
525
720
1005
1227
1535
1891
2458
3055
4078
5048
13
16
16
22
22
30
38
52
70
70
91
91
112
136
173
216
244
-
-
-
-
-
-
16
20
20
28
28
37
47
63
85
85
110
110
136
164
207
253
291
333
381
452
526
639
752
COVERED COPPER CONDUCTORS
8/6/2019 Aac Aaac Acsr & Aacsr
http://slidepdf.com/reader/full/aac-aaac-acsr-aacsr 8/8D 8
Approximate
mass per km
of covered
conductor
m m Ohm KN
25
50
100
150
150
175
175
200
200
m mm m2
Approximate
overall
diameter of
covered
conductor
Approximate
breaking load
Calculated
resistance
per km at
20
Approximate
overall
diameter of
bare
conductor
Stranding and wire dinameter
Nominal
aluminium
area
m m k gType 16 Type 16
PVC-COVERED STRANDED ALL ALUMINIUM CONDUCTOR (AAC)
(Weather resistant Line Wire)
PVC-COVERED ALUMINIUM CONDUCTOR, STEEL REINFORCED (ACSR)
(Weather resistant Line Wire)
PVC-COVERED ALUMINIUM ALLOY STRANDED CONDUCTOR (AAAC)
Approximate
mass per km
of covered
conductor
m m Ohm KN
22
50
100
200
m mm m2
Approximate
overall
diameter of
covered
conductor
Approximate
breaking load
Calculated
resistance
per km at
20
Approximate
overall
diameter of
bare
conductor
Stranding
and wire
dinameter
Nominal
aluminium
area
m m k g
Type 8 Type 8
Approximate
mass per km
of covered
conductor
m m Ohm KN
25
50
100
150
175
m mm m2
Approximate
overall
diameter of
covered
conductor
Approximate
breaking load
Calculated
resistance
per km at
20
Approximate
overall
diameter of
bare
conductor
Stranding
and wire
dinameter
Nominal
aluminium
area
m m k g
Type 16 Type 16
Aluminium Steel
m m
7/2.06
7/3.10
7/4.39
19/3.78
6.18
9.30
13.17
18.90
1.227
0.5419
0.2702
0.1349
3.99
8.28
16.00
32.40
8.2
11.7
16.0
21.7
100
200
360
690
6/2.36
6/3.35
6/4.72
30/2.59
18/3.25
18/2.79
18/3.61
30/3.00
18/3.86
7/2.34
7/3.30
7/4.65
19/3.48
19/3.76
7.02
9.90
13.95
17.40
18.80
1.094
0.5498
0.2769
0.1830
0.1568
8.44
16.80
33.30
50.65
59.10
10.6
13.9
18.0
21.4
22.8
170
280
470
680
780
1/2.36
1/3.35
7/1.57
7/2.59
1/3.35
7/2.79
1/3.61
7/3.00
1/3.86
7.08
10.05
14.15
18.13
16.75
19.53
18.05
21.00
19.30
1.093
0.5426
0.2733
0.1828
0.1815
0.1576
0.1563
0.1363
0.1367
0.61
18.35
32.70
69.20
35.70
79.80
41.10
92.25
46.55
10.7
14.1
18.2
22.2
20.8
23.6
22.1
25.0
23.3
190
330
550
920
680
1050
780
1190
870
COVERED ALUMINIUM CONDUCTORS