140G-G, 140G-H, 140G-I, 140G-J auxiliary contacts 250V-24V ((1)TUAL; (1)AX+(1)AL; (2)AX+(1)AL; (3)AX+(1)AL; (3)AX+(2)AL; (2)AX+(2)AL+(1)TUAL); (1)AX; (1)AL
Contatti ausiliari 250V-24V
Hilfskontakte 250V-24V
Contacts auxiliaires 250V-24V
Contactos auxiliares 250V-24V
DIR 1000719R0615 Version 05
Bul. 140G/140MGDIR 1000719R0615 Version 05 - 140G-G-EA_, 140G-H-EA_
WARNING: To prevent electrical shock, disconnect from power source before installing or servicing. Install in suitable enclosure. Keep free from contaminants. (Follow NFPA70E requirements).
AVVERTENZA: Per prevenire infortuni, togliere tensione prima dell'installazione o manutenzione. Installare in custodia idonea. Tenere lontano da contaminanti.
WARNUNG: Vor Installations- oder Servicearbeiten Stromversorgung zur Vermeidung von elektrischen Unfällen trennen. Die Geräte müssen in einem passenden Gehäuse eingebaut und gegen Verschmutzung geschützt werden.
AVERTISSEMENT: Avant le montage et la mise en service, couper l'alimentation secteur pour éviter toute décharge. Prévoir une mise en coffret ou armoire appropriée. Protéger le produit contre les environnements agressifs.
ADVERTENCIA: Desconéctese de la corriente eléctrica, antes de la instalación o del servicio, a fin de impedir sacudidas eléctricas. Instálelo en una caja apropiada. Manténgalo libre de contaminantes.
ATENÇÃO: Para evitar choques, desconectar da corrente elétrica antes de fazer a instalação ou a manutenção. Instalar em caixa apropriada. Manter livre de contaminantes.
Installation - Installazione - Instalación Instalação - -
(1)TUAL
(2)AX+(2)AL+(1)TUAL
(3)AX+(2)AL
(3)AX+(1)AL
(2)AX+(1)AL
(1)AX+(1)AL AL/1+AX/2
AL/1+AX/1+AX/2
AL/1+AX/1+AX/2+AX/3
AL/1+AL/2+AX/1+AX/2+AX/3
AL/1+AL/2+AX/2+AX/3+TUAL
TUAL(1)TUAL
(2)AX+(2)AL+(1)TUAL
(3)AX+(2)AL
(3)AX+(1)AL
(2)AX+(1)AL
(1)AX+(1)AL
NO
NO
NO
NO
OK
OK
OK
OK
OK
OK
OK
OK
NO
NO
NO
OK
OK
OK
OK
OK
OK
OK
OK
OK
CABLES/CAVI
KABEL/CÂBLES
AL/1
95-96-98
AL/2
15-16-18
AX/1
11-12-14
AX/2
21-22-24
AX/3
31-32-34
TUAL
05-06-08
1
1
-
-
-
-
1
1
-
-
-
-
TUAL ONLY
(1)AX+(1)AL
OK OK OK OK(1)AL
140G-G
OK
140G-H
OK
140G-I
OK
140G-J
OK(1)AX
AL/1(1)AL - -
AX/2(1)AX - -
警告:感電事故防止のため、取付けまたは修理の際は電源から取り外してください。適切なケース内に取付けてください。また、汚染物質がないことを確認してください。
警告:为了防止触电,在安装或维修之前必须先切断电源。安装在合适的设备箱内。防止接触污染 。物
(not present with
140G-G-EA1AU)
Screw
Electricaldiagram label
140G-G-EA_ _A
140G-G-EA_ _J
LENGTH M
8 mm (0.31 ") M 3.5
Voltage max current min current
IEC 24Vdc 0.1 A @ 24Vdc 1 mA @ 5Vdc
1 25Vac 0.1 A -
30Vdc 0.1 A -UL
AC-1 5 AC-1 4 AC-1 3 DC-1 4 DC-1 3 DC-1 2
250Vac 4A 5A 6A - - -
1 25Vac 5A 6A 6A - - -
250Vdc - - - 0.03A 0.03A 0.3A
1 1 0Vdc - - - 0.05A 0.05A 0.5A
Catego ry / CurrentVo ltage
AUX-C 250V, AUX-SA-C 250V
IEC
Uimp = 2.5kVUi = 300V
IEC60947-5-1
Vo ltage max current
250Vac 3A
1 25Vac 5A
250Vdc 0.2A
1 25Vdc 0.4A
UL
GB14048-5
(2)
1 2
11140G-G 140G-I 140G-H 140G-J
CLACK CLACK
140G-G, 140G-I 140G-H, 140G-J
5
5
6
CLICK
4
2
2
3
3
4
1
12
31
3
2
- If present- Se presente- Falls vorhanden- Si présent- Si lo hay
- If present- Se presente- Falls vorhanden- Si présent- Si lo hay
DIR 1000719R0615 Version 05
(3)
43
140G-G, 140G-I
Optional
140G-I
Ex. AL/1+AX/2
AL/1
AX/2
65
7
140G-G
Ex. AL/1+AX/2
AX/2
AL/1 AL/1
AX/2
SY/1 Q/1 Q/2
SY/1 Q/3 Q/1 Q/2
140G-I
140G-G
DIR 1000719R0615 Version 05
140G-H, 140G-J
Ex. AL/1+AX/2
TUAL
140G-H, 140G-J
Optional
140G-H, 140G-J
(4)
8
109
1211
140G-H, 140G-J
140G-H, 140G-J
Remove the plugsaccording to the auxiliaryyou have to install
Ex. AL/1+AX/2
AL/1
AX/2
AX/2
AL/1
AX/2
AL/1
AL/1
AX/2
Remove the plugs
SY/2SY/1
Q1 Q3 Q2
DIR 1000719R0615 Version 05
(5)
140G-G, 140G-I
13
TUAL
140G-H, 140G-J
TUAL ONLY
140G-H, 140G-J 14
15
16
3
42
2
1
1.1 Nm
9.7 lb-in
4
3
- If present- Se presente- Falls vorhanden- Si présent- Si lo hay
OptionalLENGTH M
8 mm (0.31") M 3.5
5
DIR 1000719R0615 Version 05
(6)
140G-H, 140G-J
1
17
2
CLICK
4
3
3
6
5
5
1.1 Nm
9.7 lb-in
8
7
6
- If present- Se presente- Falls vorhanden- Si présent- Si lo hay
DIR 1000719R0615 Version 05
18
32
34
34
AX3
32
31
31
21
21
22
22
AX2
24
2424
24
AX22
2
22
21
21
96
98
98
95
95
AL1
96 16
AL2
15
15
18
18
16 16
18
18
15
15
AL2
16
24
AX2
11
11
14
AX1
14
12
12
22
22
21
21
31
31
32
AX3
32
24
96
34
34
AL1
95
95
98
98
96
08
05
TU AL
06
06
05
0896
98
98
95
95
AL19
6
11
24
AX2
11
14
AX1
14
12
12
22
22
21
21
31
31
32
AX3
32
24
96
34
34
AL1
95
95
98
98
96
06
96
24
AX2
11
11
14
AX1
14
12
12
22
22
21
21
24
AL1
95
95
98
98
9608
05
06
TU AL
05
08
24
24
AX2
22
22
21
21
96
98
98
95
95
AL1
96
DIR 1000719R0615 Version 05 (B0871) - B1622 Copyright © 2017 Rockwell Automation, Inc. All Rights Reserved. Printed in Italy.
Allen-Bradley, Rockwell Software, and Rockwell Automation are trademarks of Rockwell Automation, Inc.Trademarks not belonging to Rockwell Automation are property of their respective companies.
Publication 140G-IN083F-MU-P - September 2017
Rockwell Automation maintains current product environmental compliance information on its website at http://www.rockwellautomation.com/rockwellautomation/about-us/sustainability-ethics/product-environmental-compliance.page
AX1 14-12-11 AX1 14-12-11
TUAL 06-08-05 TUAL 06-08-05
Q2 AX2 24-22-21 AX2 24-22-21 AX2 24-22-21 AX2 24-22-21
Q3 AX3 34-32-31 AX3 34-32-31 AX3 34-32-31
SY1 AL1 96-98-95 AL1 96-98-95 AL1 96-98-95 AL1 96-98-95
SY2 AL2 15-16-18 AL2 16-18-15
140G-G_
Function* Function* Function*Term. No.
(2-3-1)
140G-I_ 140G-H_ 140G-J_
Term. No.
(2-3-1)
Term. No.
(2-3-1)
Position
marked on
the breaker
Function*Term. No.
(2-3-1)
* 140-G-EA1AU is supplied as an unmarked universal replacement contact. See suggested wire markings.
NOT AVAILABLE
NOT AVAILABLE
14-12-11AX114-12-11AX1Q1
Supplied with 39 inches (1 meter) No. 20 AWG, 600V, Cu wire.
DIAGRAM REPRESENT MCCB IN OFF POSITION
MATERIALSIZE
FOLD
TO BE DETERMINEDBY STRATEGIC PARTNER
TO BE DETERMINEDBY STRATEGIC PARTNER
TO BE DETERMINEDBY STRATEGIC PARTNER
FLAT
This Instruction Sheet is Being Printed by Strategic Partner
Note: After folding---Printed in (Country where printed)* and instruction sheet number in lower left corner should be visible.
* The printing vendor may change the instruction sheet files to show the correct country.