    Quality Services Division Ambassador Apartment, 61A, Park Street, 3rd Floor, Flat No. 34, Kolkata - 700 016

    Telephone cum Fax: 033 - 2226 8335; E-mail: [email protected]

    Registered Office: “Mithona Towers -1”, 1-7-80 to 87, Opp. Wesley Co-ed Jr. College,Prenderghast Road, Secunderabad - 500 003 TEL. (EPBAX): 91 40-66238801; FAX: 91 40-66172535,

    E-Mail: [email protected]  www.tataprojects.com 

    Ref.: TPK/QS/070 November 13, 2013

    To,

    M/s. FLSmidth Private Limited - Minerals

    FLSmidth House, Kelambakkam

    Tamilnadu – 603 103

    Kind Attn.: Mr. K. Rajasekar, Assistant Manager – QC

    Dear Sir,

    Sub: Discrepancy in shaft dimension of Drive Pulley supplied by M/s. TRF Ltd., Jamshedpur.

    Ref.: 1) Your E-mail dated 29-10-2013.

    2) Our corresponding customer complaint reference no. CHE12FLS006/KOL/CC/05/291013 

    acknowledged through E-mail dated 29-10-2013.

    Brief description of complaint:

    Drive Pulley DC-1, serial numbers 5 and 6, face to tapper portion is 93 mm as per drawing

    but actual dimension measured is 188 mm due to this bearing block centre to centre

    dimension could not be maintained.

    Documents referred:

    1.  PO: FLSM/B/19876 Ver.0 dated 14-02-2011

    2.  GA Drawing: 60091003 Ver. 5.0 dated 14-09-2011

    3.  QAP: 60098593 Ver. 2.0 dated 31-10-2011

    4. TPL Inspection Reports: CHE11FLM004/KOLTRF0106121PTB,CHE11FLM004/KOLTRF2407121IMA, CHE12FLS006/JAMTRF1304131DBX and

    CHE12FLS006/KOLTRF2504131BBN

    Findings:

    Based on the complaint referred above, we have further investigated the matter and

    following are the findings.

    Drive Pulley marked DC1, serial numbers 5 and 6 were offered for inspection before and

    after the rubber lagging. Our Surveyors carried out visual, dimensional, run-out, static

    balancing inspection as per the QAP and accepted vide inspection reports -

    CHE11FLM004/KOLTRF2407121IMA and CHE12FLS006/KOLTRF2504131BBN. No dimensionaldeviations on the shafts were noticed during the inspection by our Surveyor.

    On further investigation and interaction with the supplier, we understand that the

    dimension (H+G) at coupling end of the shaft was made 440 mm instead of (382+157) 539

    mm as per the drawing which resulted into shifting of bearing centre at the drive end. We

    agree that this discrepancy in shaft dimension should have been noticed by our Surveyors

    during inspection of the pulleys and highlighted in the inspection reports.

  • 8/18/2019 FLSmidth TRF Pulley

    2/2

     

    Conclusion:

    The concerned Surveyors have been briefed appropriately.

    We sincerely regret for the inconvenience caused and assuring you of our best services at all

    times.

    Very truly yours,

    For TATA PROJECTS LIMITED 

    ( Susanta Chatterjee )

    Centre Head - Kolkata