![Page 2: Oxidation of Ni-30%Cr according to the Wagner Model](https://reader036.vdocuments.pub/reader036/viewer/2022062323/5681633c550346895dd3cbfb/html5/thumbnails/2.jpg)
Pt-30%Ni Ni-30%Cr The oxidation of an alloy
2
Alloy
x0
Oxide
0 xΔxmetal
Δxoxide
Initial Situation After oxidation during dt
Alloy
![Page 3: Oxidation of Ni-30%Cr according to the Wagner Model](https://reader036.vdocuments.pub/reader036/viewer/2022062323/5681633c550346895dd3cbfb/html5/thumbnails/3.jpg)
I) Presentation of the Wagner model described for Ni-Pt
II) Analysis of the results obtained by the Wagner model on Ni-30%Pt
III) My experimental study on Ni-30%Cr
Conclusion
3
![Page 4: Oxidation of Ni-30%Cr according to the Wagner Model](https://reader036.vdocuments.pub/reader036/viewer/2022062323/5681633c550346895dd3cbfb/html5/thumbnails/4.jpg)
• Theoretical analysis of the diffusion processes.
Published in 1952, under the title :Theoretical Analysis of the Diffusion Processes Determining the
Oxidation Rate of Alloys, by Carl Wagner.
4
C. Wagner, “Theoretical Analysis of the Diffusion Process Determining the Oxidation Rate of Alloys”, Journal of the Electrochemical Society, 99 [10] (1952) 369-380.
![Page 5: Oxidation of Ni-30%Cr according to the Wagner Model](https://reader036.vdocuments.pub/reader036/viewer/2022062323/5681633c550346895dd3cbfb/html5/thumbnails/5.jpg)
The diffusion process
5
x
Ni-Pt alloyNiO
2e- , Ni2+Ni
Pt
NA(i)
NA(e)
Ni2++2 e- + ½ O2-> NiO
air
NA(b)
![Page 6: Oxidation of Ni-30%Cr according to the Wagner Model](https://reader036.vdocuments.pub/reader036/viewer/2022062323/5681633c550346895dd3cbfb/html5/thumbnails/6.jpg)
The main assumptions of the Wagner model :In the alloy Migration of nickel ions takes place by jumping of nickel ions from
normal lattice sites to adjacent vacant sites. No variation of the interdiffusion coefficient D
In the oxide Thermodynamic equilibrium in the oxide scale The oxidation rate follows a parabolic law :
6
![Page 7: Oxidation of Ni-30%Cr according to the Wagner Model](https://reader036.vdocuments.pub/reader036/viewer/2022062323/5681633c550346895dd3cbfb/html5/thumbnails/7.jpg)
The Flux of metal ions :
Equilibrium condition for the reaction 2 Ni (alloy) + O2 (gaz) = 2 NiO :
7
(NA(e)is « equilibrium mole fraction « for a given ambient partial pressure, at the oxide-air interface .)
with aNiO=1 and aNi=NA
![Page 8: Oxidation of Ni-30%Cr according to the Wagner Model](https://reader036.vdocuments.pub/reader036/viewer/2022062323/5681633c550346895dd3cbfb/html5/thumbnails/8.jpg)
The equilibrium of flux of nickel atoms in the interface alloy-oxide gives us :
The Fick’s second law :
We define :
8
(1)
(2)
(3)
![Page 9: Oxidation of Ni-30%Cr according to the Wagner Model](https://reader036.vdocuments.pub/reader036/viewer/2022062323/5681633c550346895dd3cbfb/html5/thumbnails/9.jpg)
By (1), we have :
So, I define :
The equation (2) become :
So,
with erf the error function :
9
![Page 10: Oxidation of Ni-30%Cr according to the Wagner Model](https://reader036.vdocuments.pub/reader036/viewer/2022062323/5681633c550346895dd3cbfb/html5/thumbnails/10.jpg)
With :
we find :
For NA(i)= 0.22 and NA(b) = 0.3, α=0.99 and γ= 100 :
10
(4)
(NA(b) = 0.3 = « bulk mole fraction »)
![Page 11: Oxidation of Ni-30%Cr according to the Wagner Model](https://reader036.vdocuments.pub/reader036/viewer/2022062323/5681633c550346895dd3cbfb/html5/thumbnails/11.jpg)
By (1), we find the molar fraction of nickel at the interface alloy-oxide NA(i) verify :
11
(5)
We recall that :
![Page 12: Oxidation of Ni-30%Cr according to the Wagner Model](https://reader036.vdocuments.pub/reader036/viewer/2022062323/5681633c550346895dd3cbfb/html5/thumbnails/12.jpg)
Influence of D or γ (=D/k°c) on the value of NA(i) :At T = 850°C, for Ni-Pt, we have : NA(e)= 6.4. 10-7, K°c= 4.1. 10-12 cm²/sec
and D ≈ 3.1. 10-12 cm²/sec, and γ=0.76.I do vary D from 5.10-14 to 1.10-9 ie γ from 0.012 to 243.
12
![Page 13: Oxidation of Ni-30%Cr according to the Wagner Model](https://reader036.vdocuments.pub/reader036/viewer/2022062323/5681633c550346895dd3cbfb/html5/thumbnails/13.jpg)
13
NA(i) = f(Log(gamma))
![Page 14: Oxidation of Ni-30%Cr according to the Wagner Model](https://reader036.vdocuments.pub/reader036/viewer/2022062323/5681633c550346895dd3cbfb/html5/thumbnails/14.jpg)
Analysis of the oxidation at 950°C of three samples oxidized during 1h, 10h and 100h and quenched in the liquid nitrogen before observation
• Observation in Metallography • Observation of the concentration profile in the SEM by EDX• Observation of the concentration profile by Auger
Spectroscopy ...
14
![Page 15: Oxidation of Ni-30%Cr according to the Wagner Model](https://reader036.vdocuments.pub/reader036/viewer/2022062323/5681633c550346895dd3cbfb/html5/thumbnails/15.jpg)
Why we use both EDX and Auger Spectroscopy?
15
Analysis by EDX of the μm scaleAnalysis by Auger
Spectroscopyof the nm scale
Oxide Scale
AES + ion eatching
![Page 16: Oxidation of Ni-30%Cr according to the Wagner Model](https://reader036.vdocuments.pub/reader036/viewer/2022062323/5681633c550346895dd3cbfb/html5/thumbnails/16.jpg)
16
First results obtained by Metallography
Sample oxidized during 1h x100 Sample oxidized during 10h x100
![Page 17: Oxidation of Ni-30%Cr according to the Wagner Model](https://reader036.vdocuments.pub/reader036/viewer/2022062323/5681633c550346895dd3cbfb/html5/thumbnails/17.jpg)
With the Wagner model, it is possible to obtain the concentration profile of the Chromium in the alloy.
NA(i) strongly depends on the value of diffusion coefficient!
My future study is aimed to validate (or not) the utilization of Wagner model to describe the concentration profile of the Chromium in the alloy.
17
![Page 18: Oxidation of Ni-30%Cr according to the Wagner Model](https://reader036.vdocuments.pub/reader036/viewer/2022062323/5681633c550346895dd3cbfb/html5/thumbnails/18.jpg)
Thank you for your attention
18
![Page 19: Oxidation of Ni-30%Cr according to the Wagner Model](https://reader036.vdocuments.pub/reader036/viewer/2022062323/5681633c550346895dd3cbfb/html5/thumbnails/19.jpg)
19
y = 0.3
• Interpretation Mathematics :
• Interpretation Physics :
For γ<10, the diffusion in the alloy is too slow.Each time a Cr atom arrives to the alloy-oxide interface, it diffuses « instantaneously » into the oxide scale…