PENETRAMETER
-
8/12/2019 Penetra Meter
2/19
It is a device that is used inradiographictesting to
evaluate the quality of
radiographic images.
-
8/12/2019 Penetra Meter
3/19
Radiography It is type Non-destructive Testing.
Technique is suitable for the detection
of internal defects.
Rays generated are penetrating
radiation which is differentially
absorbed by the material through
which it passes.
-
8/12/2019 Penetra Meter
4/19
Radiography
In proportion to the intensity of theradiation reaching the film, and
therefore forming a latent image.
Image developed in a similar way to
normal photographic film.
Usually X-rays or Gamma rays are
used.
-
8/12/2019 Penetra Meter
5/19
-
8/12/2019 Penetra Meter
6/19
Penetrameter
Image quality indicators (IQIs).
Indicates change in material thicknesswill be detectable in the radiograph.
They come in a wide range of shapes,size
and configurations.
Made from the same type of material as
the specimen being tested.
-
8/12/2019 Penetra Meter
7/19
Image sharpness
Image contrast Good
IQI
Image Noise
The quality of a radiographic image
can be assessed in terms of three
factors:
-
8/12/2019 Penetra Meter
8/19
There are four broad patterns of
IQI
1. Wire type
2. Step/hole type
3. Hole-in-plaque type
4. Duplex wire type
-
8/12/2019 Penetra Meter
9/19
-
8/12/2019 Penetra Meter
10/19
Hole-Type IQIs This consists of a small rectangular
piece of metal with holes.
Notching system is incorporated for if
IQI is the correct material type.
Image quality levels are typically
designated using a two part
expression such as 2-2T.
-
8/12/2019 Penetra Meter
11/19
Hole-TypeIQIs
-
8/12/2019 Penetra Meter
12/19
Hole-Type
IQIs
-
8/12/2019 Penetra Meter
13/19
Wire type It consists of a number of wires of various
diameters are held parallel to one another
in a low density plastic mount.
A typical wire IQI will contain six or sevenwires arranged in order of increasing
diameter.
Diameter of the thinnest discernible wire
is taken as a measure of IQI (wire)
sensitivity
-
8/12/2019 Penetra Meter
14/19
Wire sizes that correspond to
various hole-type quality levelscan be found
-
8/12/2019 Penetra Meter
15/19
IQI (wire) sensitivity
-
8/12/2019 Penetra Meter
16/19
Placement of IQIs
-
8/12/2019 Penetra Meter
17/19
Placement of IQIs
Place the IQI on the side of thespecimen facing the radiation source.
Most tables of IQI values assume thatthe IQI is in this position.
IQI image is completely insensitive togeometric un-sharpness factors such
as source-to-film distance.
-
8/12/2019 Penetra Meter
18/19
Conclusions
None of the existing designs of IQIs issufficiently sensitive to image
sharpness parameters .
wire can be drawn suitable for use onthin specimens, are available .
For non-metals, the step/hole type is
the most convenient . used to measure just the quality of the
radiographic image.
-
8/12/2019 Penetra Meter
19/19