Pre-Construction Report
GlenMartin Holding Co., LLC
Site Name:
Contractor Name:
Notes: Inspected tower to measure for diminsions for installation of structural reinforcement. Also noted is additional maintenance that needs to be addressed, see below fo
more detail. Site is approximately 1.8 miles from gate and sign. Must access through a second gate, then proceed an additional 1/4 to 1/2 mile to tower.
2/14/2013Date of Inspection:
GlenMartin Holding Co., LLC
SITE VISIT INFORMATION
BLUE MTSite Number: TX-5076
Add ress : 1604A Business Loop I-70WCity/State: Columbia, MO 65202Inspection Completed By: J ack Ray, Above All Tower Climbing, LLC
Contact Phone Number: 314-496-2406Client/Customer Name: Global Tower PartnersAdd ress : www.gtpsites.com
City/State:
City/State:
Contact Name:
Contact Phone Number: 866-487-8977
GENERAL SITE INFORMATION
Site Owner Name: Global Tower Partners
Add ress : www.gtpsites.com
Contact Name:
Contact Phone Number: 866-487-8977Site Address: Blue Mountain Peak Ranch Rd
Tower Height: 199'
City/Sate Mason, TXLatitude: 30.56472222
Longitude: -99.45361111Gate Combo: 1801
TOWER INFORMATION
Structure Type: Guyed
Overall Structure Height: 201'Tower Manufacturer: UnknownNumber of Tower Legs: 3
ADDITIONAL INFORMATION
Climbing/Safety Device: Pegs on one side of "A" Leg with Safe Climb CableFCC/ASR Number: 1047020AM Detu nin g ? : N/A
Additionalmaintenanceneededtobeaddressed:(1) Towerpainthasdeterioratedtoapproximatelyonly5%to10%ofthetowercovered.Ref.picTX5076.2. (2)Noneofthecoaxispainted.Ref.picTX5076.2(3) Thereisnoicebridgeprotectingthecoaxrunningfrombuilding#2.Ref.picTX5076.4.(4)Climbingpegsareonlylocatedonthesouthsideofthe"A"leg.Thismakesitextremelydifficult,almostcounterproductivetousethesafeclimbcablewhen
ascendingthetower.Notallholesarepresentforpegsonthenorthsideofthe"A"leg.Holesmustbedrilledtoinstallpegs. (5) Guywiresafetycableoffof
Regardingstructuralreinforcement : Existinghorizontalsareflat,anglesteel. Thehorizontalsinthespecifiedareaareallunobstructedwiththeexceptionofone ThehorizontalontheA/BFaceofthetower,facingnorth@185'hasthreecoaxlinesattachedtoit.
-
7/27/2019 Pre Con Inspection
2/8
Guyed Tower
GlenMartin Holding Co., LLC
Base Plate Grouted?:
See Additional
No Height of pivot section: N/A
N/A Face wid th @ top : 36"
Leg splice type (flange, lap, butt) Flange with 1/2" Bolts
N/A Face wid th @ taper change: N/A
N/A Elevation of taper change: N/A
No Azim uth of "A" Leg? : 270 degrees
N/A Center to center face width @ bottom: 36"
6"X6" Anc hor Bol t Separation: N/A
1/2" Which leg/face is the ladder/pegs on? A
3'x3'x3' Anc hor Bol t Quan ti ty: 3
Square Anc hor Bol t Patt ern: Single b olt per plat e
Tower Base InformationTri-Angle Anc hor Bol t Size: 5/8"
Inspection Completed By:
Date of Inspections:
Site Name:
Site Number:
BLUE MT
TX-5076
J ack Ray, Above All Tower Climbing, LLC
2/14/2013
Foundation Shape:
Foundation Size:
Base Plate Shape:
Base Plate Dimensions:
Base Plate Thickness:
Base Plate Stiffeners?:
Quantity:
Height:
Width:Thickness
Tower Section Diagrams
-
7/27/2019 Pre Con Inspection
3/8
GlenMartin Holding Co., LLC
1 72
2 73
3 74
4 75
5 76
6 77
7 78
8 79
9 80
10 8111 82
12 83
13 84
14 85
15 86
16 87
17 88
18 89
19 90
20 91
21 92
22 9323 94
24 95
25 96
26 97
27 98
28 99
29 100
30 101
31 102
32 103
33 10434 105
35 106
36 107
37 108
38 109
39 110
40 111
41 112
42 113
43 114
44 115
45 11646 117
47 118
48 119
49 120
50 121
51 122
52 123
53 124
PHOTO LIST
TX-5076.1- Site Sign
TX-5076.2- Over All Site
TX-5076.3- Site Building 1
TX-5076.4- Site Building 2
TX-5076.11- Coax Mounted on North Side of "A" Leg @ 185'
TX-5076.12- Antenna Mount @ 185'-8" on "B" Leg
TX-5076.13- Antenna @ 185'-8" on "B" Leg
Addt'l 1 Guy Safety Cable not connected
Addt'l 2 U-Bolt missing from add-on horizontal
Addt'l 3 Foundation deteriorated on "A" corner, re-bar exposed
TX-5076.5- Tower Foundation
TX-5076.6- Tower Section Connecting Flange with bolt spacing
TX-5076.7- Bottom of Guy Mount at 184'
TX-5076.8- Top of Guy Mount at 189"
TX-5076.9- 180' Mark on Tower
TX-5076.10- 191' Mark on "A" Leg with Safe Climb Attachment
Addt'l 10 Temporary safety cable installed on guy anchors
Addt'l 11 Secured Coax to tower
Addt'l 4 Foundation deteriorated on "C" face, re-bar exposed
Addt'l 5 No ice bridge protecting coax from Building 2 to tower
Addt'l 6 Bolt Holes misaligned on guy mounts
Addt'l 7 Bolts Missing from lower guy mount
Addt'l 8 Bolts missing from upper leg of guy mount
Addt'l 9 Coax not secured below topmost antenna (blowing in wind)
Site Name:
Site Number:
Date of Inspection:
Inspection Completed By:
BLUE MT
TX-5076
J ack Ray, Above All Tower Climbing, LLC
2/14/2013
-
7/27/2019 Pre Con Inspection
4/8
TX5076.1 TX5076.2
TX5076.3 TX5076.4
-
7/27/2019 Pre Con Inspection
5/8
TX5076.7 TX5076.8
TX5076.9 TX5076.10
-
7/27/2019 Pre Con Inspection
6/8
TX5076.13 Addtl1
Addtl2 Addtl3
-
7/27/2019 Pre Con Inspection
7/8
Addtl6 Addtl7
Addtl8 Addtl9
-
7/27/2019 Pre Con Inspection
8/8
45"