Download - Precise wavelength reference for Spirou F. Pepe, F. Wildi, B. Chazelas, C. Lovis, S. Udry
![Page 1: Precise wavelength reference for Spirou F. Pepe, F. Wildi, B. Chazelas, C. Lovis, S. Udry](https://reader031.vdocuments.pub/reader031/viewer/2022013012/56649e875503460f94b8b716/html5/thumbnails/1.jpg)
Precise wavelengthreference for Spirou
F. Pepe, F. Wildi, B. Chazelas, C. Lovis, S. Udry
![Page 2: Precise wavelength reference for Spirou F. Pepe, F. Wildi, B. Chazelas, C. Lovis, S. Udry](https://reader031.vdocuments.pub/reader031/viewer/2022013012/56649e875503460f94b8b716/html5/thumbnails/2.jpg)
The wavelength calibration
px
λi ref
xi
λx
Thorium lines
Achieved Δλλ: (Absolute) accuracy: 5 x 10-8
Scale factor: 3 x 10-8 Repeatability: 6 x 10-10 (= 20 cms-1)
![Page 3: Precise wavelength reference for Spirou F. Pepe, F. Wildi, B. Chazelas, C. Lovis, S. Udry](https://reader031.vdocuments.pub/reader031/viewer/2022013012/56649e875503460f94b8b716/html5/thumbnails/3.jpg)
The perfect calibrator
Cover full spectral range
Constant line spacing
Lines width < spectrograph resolution
High density of lines, up to one per ~2-3 SE
All wavelengths precisely known and stable
Homogeneous line intensities, high ‘brightness’
Fabry-Pérot or Laser frequency comb
![Page 4: Precise wavelength reference for Spirou F. Pepe, F. Wildi, B. Chazelas, C. Lovis, S. Udry](https://reader031.vdocuments.pub/reader031/viewer/2022013012/56649e875503460f94b8b716/html5/thumbnails/4.jpg)
The perfect calibrator
![Page 5: Precise wavelength reference for Spirou F. Pepe, F. Wildi, B. Chazelas, C. Lovis, S. Udry](https://reader031.vdocuments.pub/reader031/viewer/2022013012/56649e875503460f94b8b716/html5/thumbnails/5.jpg)
HARPS FPCS System
Vacuum control
Temperature control
Light source
![Page 6: Precise wavelength reference for Spirou F. Pepe, F. Wildi, B. Chazelas, C. Lovis, S. Udry](https://reader031.vdocuments.pub/reader031/viewer/2022013012/56649e875503460f94b8b716/html5/thumbnails/6.jpg)
HARPS Fabry-Pérot Assembly
![Page 7: Precise wavelength reference for Spirou F. Pepe, F. Wildi, B. Chazelas, C. Lovis, S. Udry](https://reader031.vdocuments.pub/reader031/viewer/2022013012/56649e875503460f94b8b716/html5/thumbnails/7.jpg)
Fabry-Pérot at La Silla
Calibration Unit
![Page 8: Precise wavelength reference for Spirou F. Pepe, F. Wildi, B. Chazelas, C. Lovis, S. Udry](https://reader031.vdocuments.pub/reader031/viewer/2022013012/56649e875503460f94b8b716/html5/thumbnails/8.jpg)
FPCS Spectrum with HARPS
![Page 9: Precise wavelength reference for Spirou F. Pepe, F. Wildi, B. Chazelas, C. Lovis, S. Udry](https://reader031.vdocuments.pub/reader031/viewer/2022013012/56649e875503460f94b8b716/html5/thumbnails/9.jpg)
FPCS Specifications
![Page 10: Precise wavelength reference for Spirou F. Pepe, F. Wildi, B. Chazelas, C. Lovis, S. Udry](https://reader031.vdocuments.pub/reader031/viewer/2022013012/56649e875503460f94b8b716/html5/thumbnails/10.jpg)
FPCS short-term RV-stability
Time series of 7 hours
![Page 11: Precise wavelength reference for Spirou F. Pepe, F. Wildi, B. Chazelas, C. Lovis, S. Udry](https://reader031.vdocuments.pub/reader031/viewer/2022013012/56649e875503460f94b8b716/html5/thumbnails/11.jpg)
FPCS long-term RV-stability
Nightly calibration over 80 nights
![Page 12: Precise wavelength reference for Spirou F. Pepe, F. Wildi, B. Chazelas, C. Lovis, S. Udry](https://reader031.vdocuments.pub/reader031/viewer/2022013012/56649e875503460f94b8b716/html5/thumbnails/12.jpg)
New-generation FPCS
Mechanics instead of glass work (maintenance)
New white light source (reliability and costs)
Mirrors instead of lenses (wide range, IR) for collimator and camera
Optimize etalon for stability and throughput over the specified spectral range
Etc.
![Page 13: Precise wavelength reference for Spirou F. Pepe, F. Wildi, B. Chazelas, C. Lovis, S. Udry](https://reader031.vdocuments.pub/reader031/viewer/2022013012/56649e875503460f94b8b716/html5/thumbnails/13.jpg)
Spirou FPCS configurationSupercontinuum laser or LDLS (laser-driven Xe)
Fiber-link from source to vacuum vessel
Vacuum vessel (fiber in- and output)
Thermal control
FPCS opto-mechanics (support and mirrors)
FP etalon
Fiber from vacuum vessel to calibration unit
Interface: Standard FC or SMA fiber connector (Etendue TBD)
![Page 14: Precise wavelength reference for Spirou F. Pepe, F. Wildi, B. Chazelas, C. Lovis, S. Udry](https://reader031.vdocuments.pub/reader031/viewer/2022013012/56649e875503460f94b8b716/html5/thumbnails/14.jpg)
LDLS light source
Up to 2400 nm !(like 10’000 K BB)
![Page 15: Precise wavelength reference for Spirou F. Pepe, F. Wildi, B. Chazelas, C. Lovis, S. Udry](https://reader031.vdocuments.pub/reader031/viewer/2022013012/56649e875503460f94b8b716/html5/thumbnails/15.jpg)
New opto-mechanics design (in progress)
![Page 16: Precise wavelength reference for Spirou F. Pepe, F. Wildi, B. Chazelas, C. Lovis, S. Udry](https://reader031.vdocuments.pub/reader031/viewer/2022013012/56649e875503460f94b8b716/html5/thumbnails/16.jpg)
Spirou FPCS capital cost
Light source: 25’000 EUR
FP etalon: 20’000 EUR
Vacuum vessel: 10’000 EUR
Vacuum gauges and control: 15’000 EUR (TBC)
FPCS opto-mechanics: 25’000 EUR
Thermal control: 5’000 EUR
Fibers: 2’000 EUR
Total: 102’000 EUR (TBC)
![Page 17: Precise wavelength reference for Spirou F. Pepe, F. Wildi, B. Chazelas, C. Lovis, S. Udry](https://reader031.vdocuments.pub/reader031/viewer/2022013012/56649e875503460f94b8b716/html5/thumbnails/17.jpg)
Spirou FPCS manpower costs
Requirements definition: 0.1 FTE
Design optimization: 0.3 FTE
Procurement of components: 0.2 FTE
Opto-mechanics manufacturing: 0.5 FTE
Assembling and adjusting: 0.2 FTE
Testing and tuning: 0.2 FTE
Total: 1.5 FTE (TBC)
![Page 18: Precise wavelength reference for Spirou F. Pepe, F. Wildi, B. Chazelas, C. Lovis, S. Udry](https://reader031.vdocuments.pub/reader031/viewer/2022013012/56649e875503460f94b8b716/html5/thumbnails/18.jpg)
Spirou FPCS travel costs
Roughly 10’000 EUR per phase (depends strongly on number of meetings and reviews)
Total: 40’000 EUR (TBC)
Does not include participation to (other) workgroups