/ 20 30 50
20 30 50
20 40 60
() Vb
Vb = PTV Np / 1000 [m 3]
PTV ()
Np (-)
Q Q = Vb cp T [kWh]
Vb [m3]
p [kWh/m 3K]
T [K]
= 1360 [W/m 2] = 800 1000 [W/m 2]
2
-
8/2/2019 Preporaki Za Koristenje Na Soncevata Energija Za Podgotovka Na Sanitarna Topla Voda
3/16
[W/m2] 600 - 1000 200 400 50 150
[%] 10 - 20 20 - 80 80 - 100
.
kWh/m 2 ( - )
I II III IV V VI VII VIII IX X XI XII . ..
44 65 102 135 177 179 197 182 131 82 44 33 1367 41.45N
Sz() = 197 [kWh/m 2] / 31 = 6,3 kWh / m 2Sz() = 33 [kWh/m 2] / 31 = 1,1 kWh / m 2
[kWh/m2/.]
3
-
8/2/2019 Preporaki Za Koristenje Na Soncevata Energija Za Podgotovka Na Sanitarna Topla Voda
4/16
: Q k = Sz k [kWh/m2] : Q ss = Sz k sis = Q k sis [kWh/m2]
- s s - (, .../ 0,8/)
: Nk = Q / Qk (100% )
Nk = 0.5 Q / Qk (50% )
, :
,
..()
/
40 16.5 40 63.5
!
(Tks-Tvoz )/ G t [m 2K/W]
Tks = 55 oC
Tvoz = 30 oC
G T = 800 W/m 2
= 0,62
Tks = 50 oC
Tvoz = 10 oC
G T = 800 W/m 2
= 0,52
4
-
8/2/2019 Preporaki Za Koristenje Na Soncevata Energija Za Podgotovka Na Sanitarna Topla Voda
5/16
-
: , : 41.45 ,
16.5
, 63.5 40
, (). 0,8 1,2 , , .
: 25 , 100 . : V b = 25 4 1,2 = 120 .
, . 90% 120% .
( ) [m2] [mm] []
1 2 16
4 6 20
10 12 25 1
15 20 32 1
25 - 30 40 1
. .
. , . . () .
5
-
8/2/2019 Preporaki Za Koristenje Na Soncevata Energija Za Podgotovka Na Sanitarna Topla Voda
6/16
()
()
*[m2]
**[m2]
50 50 75 1.0 1.5 0.9 1.3
100 100 150 2.0 3.0 1.5 2.5200 200 300 3.5 4.5 3.0 4.0300 300 450 4.5 6.0 4.0 5.0500 500 750 7.5 10 6.0 8.51000 1000 - 1500 15 - 20 12 - 16
* ; **
. ( ) .
[W/mK]
50 210
380
. ! () , . (0.3 - 2.5 ), (
2.5 50 ), . : : 0 < 0.2, > 0.9 : 0.2 < 0.5, > 0.9 : 0.5 < 1.0, > 0.9
, . , .. , . . .
6
-
8/2/2019 Preporaki Za Koristenje Na Soncevata Energija Za Podgotovka Na Sanitarna Topla Voda
7/16
[mm] [kg/m2]
* 4 10 0.84
4 10 0.84
4 10 0.91
4 10 0.95
PMMA ( ) 16 5.0 0.77
PMMA (..) 16 5.6 0.72*
. , . , , . , .
. [oC]
[kg/m3] [W/ mK] 20oC
> 200 60 200 0.040
> 200 30 100 0.040
> 200 130 150 0.048
< 130 30 80 0.030
< 80 30 - 50 0.034
() (). , , , . :
()
7
-
8/2/2019 Preporaki Za Koristenje Na Soncevata Energija Za Podgotovka Na Sanitarna Topla Voda
8/16
1.
1 1 .
1.1
. , 20 998,4 kg/
m3
, 80
971,6 kg/m3
, 3% . , , . , .
. . , .
1.2 ( 1) ( ) . 0 . , .
, , . ( 1). - () .
0,
, . , - .
1 () 1 - ()
8
-
8/2/2019 Preporaki Za Koristenje Na Soncevata Energija Za Podgotovka Na Sanitarna Topla Voda
9/16
, , . . .
, ( ), . , , .
.. icS- ( ) 2. .
2
1.3
, 160 45 . :
: / = 0,7 1,2 0,7 1,2 m 2 ()
= 0,4 1 m : / = 0,4 0,7 (
2m2)
20 mm. ,
.
9
-
8/2/2019 Preporaki Za Koristenje Na Soncevata Energija Za Podgotovka Na Sanitarna Topla Voda
10/16
, () 0,5 0,6, 50 60% (160/ 45 10 oc, Q = 8543920 kJ 2373 kWh ) . 1187 1424kWh 300 400 kWh/m 2.
2.
. 200 300 3 6 m 2, ( ).
3 . , (). - , , , , .
3
. , . 20 , .
10
-
8/2/2019 Preporaki Za Koristenje Na Soncevata Energija Za Podgotovka Na Sanitarna Topla Voda
11/16
2.1
4 .
, , , . . () . . ( 6 10 ), . , . , . . . 95 , ( . 45 ).
2.2
:
1 1,5 m 2 () 75 m 2 .
4
, 1500 kWh ( 4 ) 50 60% . 150 150 m 3 .
11
-
8/2/2019 Preporaki Za Koristenje Na Soncevata Energija Za Podgotovka Na Sanitarna Topla Voda
12/16
3.
, , , . , m 2 , m 2 .
3.1
.. ( 5) .
: , , . () . , , , .
( 6). 10% . , .
. , . : , , .
5
12
-
8/2/2019 Preporaki Za Koristenje Na Soncevata Energija Za Podgotovka Na Sanitarna Topla Voda
13/16
6
() , 3. , , .
,
. ( 7) .
7
3.2
, . , , . ( . ) . , ,
. , .
13
-
8/2/2019 Preporaki Za Koristenje Na Soncevata Energija Za Podgotovka Na Sanitarna Topla Voda
14/16
, 4 . , .
, , . , , , . , .. .
() ,
:
2 m 2 65 70 ( 60 ) () 50 /m 2
, 30%.
4. , :
:
1500 kWh/
. ( ):
7 /kWh
.: 95% 7,35 /kWh
.: 3% 9,88 /kWh (10 .)
: 27.675,00 /m2 x 3 = 83.025,00
: 1500 kWh X 9,88 = 14.820,00
: 83.025,00 / 14.820,00 = 5,6