Coromatic Mission
• Vi designer, bygger og leverer
forretningskritisk infrastruktur baseret på
vores kunders forretningsbehov
• Vi drifter og optimerer de kritiske
faciliteter hele deres livscyklus igennem
• Grundlagt 1992
• Samlet omsætning 2014: 140+ MEUR
• 460 medarbejdere
• 15 afdelinger i Norden
• 75 forretningsskritiske anlæg leveret
årligt
• Flere end 3.600 servicekontrakter
• Mulighed for global levering
Om koncernen
Critical Facility Management
– Sikring af virksomhedskritiske funktioner
Drift
Optimering
Muliggøre adgang
Strøm
Kommunikation
DC
Energi-
optimering
Distribution af strøm
Overvågning
og analyse
Køling
Perimeter-
kontrol
Mobil-
dækning
Brandforebyggelse
Design og konstruktion
Service-
administration
Kabling
Lavspændings-
belysningRådgivning
Forhindre adgang
Business AreasVi bygger bygningen
- Brandsikre døre
- ADK adgangskontrol
- AIA/ABA
- CCTV overvågningVi leverer, implementerer og drifter UPS
30+ års erfaring
Ledende i Norden
Bredt produktsortiment
Specialtilpassede løsninger
Plug-bare og installerbare
(fra 600VA til 5,4 MVA)
Køl installation:
• Chiller
• Fancoils
• Frikøling
• rørinstallation mv.
• PLC styring
• lækage detekteringOvervågning/
Vi sørger for:
- EDB gulv
- Kabling
- Racks
- PDUer
Vi leverer, implementerer og drifter Brandslukning ARS
El-installationer:
- Forsyninger
- EL tavler
- kanalskinner / BUS-bar
- Føringsveje- Kabling: kobber og fiber
- Udligning
- Belysning
Vi leverer, implementerer
og drifter Generatorer.
- Tilpassede løsninger
- Egen produktion
- Flere leverandører
Batterier
Lang erfaring med salg og produktion
Industribatterier
Bredt udvalg af bly (pb) og
Nickel Cadmium (NiCd)
Fritventilerede, og
ventilregulerede vrla-batterier
Solar batterier
Fra 1,2V til 13000 Ah
Nordisk centrallager
Tier Topology
• Tier I – Basic Capacity
• Tier II – Redundant Components
• Tier III – Concurrent Maintainable
> Applies to Each and Every component and path
• Tier IV – Fault Tolerant
> Considers a Single event, but Consequential impact
• Tier Standard : Operational Sustainability> Management and operation of a built environment
Gold, Silver, Bronze
Power distribution
Cooling
Design & Construct
Service
Management
Cabling
Fundamentals in data center design
• Redundancy, N, N+1, N+2, 2N, A+B etc.
• Capacity components in data center *
• Nothing outside the facility is reliable except
fiber and air *
• Compartmentalization
• Continuous cooling
N+1 components
N=2
* According to Tier Standards
• Redundant capacity components and independent distribution paths
• Some elements of a distribution path may be inactive
• Standard is based on dual-corded IT equipment
• No runtime limits on engine-generator capacity at design load• Each and Every capacity component and distribution path element can be
taken out of service for maintenance, repair or replacement without impacting
the critical environment or IT processes
• Operations: Human errors may lead to site disruption
Tier III: Concurrently Maintainable
Case Study: Mærsk Olie og Gas A/S
Design objective:
• Tender
• Tier III certified data center
• Maximum total critical load 140 kW
• Full A+B redundancy
• Data Center As a Service operated by Coromatic A/S, Denmark
Mærsk outcome!
- Vi ved at det er Tier III DC og ikke ”blot” tror
- Vi vurderer at det ikke har været dyrere at få certificeringen med – vi valgte
at det er et leverandør ansvar at få certificeringen.
- Teknisk bedste all arround løsning. Som eksempel var der 15% forskel på
energi forbrug på løsningsforslag 1 og 2