edwards ava devices advanced venous access 美商愛德華公司: gina chen

11
Edwards AVA Devices Advanced Venous Access 美美美美美美美Gina Chen

Upload: cameron-crawford

Post on 18-Dec-2015

286 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: Edwards AVA Devices Advanced Venous Access 美商愛德華公司: Gina Chen

Edwards AVA DevicesAdvanced Venous Access

美商愛德華公司: Gina Chen

Page 2: Edwards AVA Devices Advanced Venous Access 美商愛德華公司: Gina Chen

AVA - Increase Your Options

• Reduces risk of infection, only one site• Reduces insertion time for clinician• Reduces nurse line maintenance • Less irritation to patient

Page 3: Edwards AVA Devices Advanced Venous Access 美商愛德華公司: Gina Chen

AVA - Increase Your Options

• TRIPLE lumen infusion + sheath + catheter insertion

• Employ only one insertion site which may reduce device complications and infection

• Maximize flow rates with FLEXIBLE lumen walls

• Increase flexibility for rapid response to patients requiring a second catheter insertion

• With AMC thromboshield

Page 4: Edwards AVA Devices Advanced Venous Access 美商愛德華公司: Gina Chen

AAdvanced dvanced VVenous enous AAccess Devicesccess DevicesAVA

Patients’ needs change by the minute, but there their central venous access shouldn’t

AVA 3Xi 8.5F

AVA High-Flow 9F

Page 5: Edwards AVA Devices Advanced Venous Access 美商愛德華公司: Gina Chen

Comparison of AVA Devices

AVA HF AVA 3Xi

Patient Type High-risk medical/surgical patients High infusion/volume need

Fast-track and routine cardiac surgical patients involving multiple access lines

French Size 9F

(11 cm)

8.5F

(11cm)

Swan-Ganz Size Up to 8F Up to 7.5F

Page 6: Edwards AVA Devices Advanced Venous Access 美商愛德華公司: Gina Chen

Competencies in extrusion Innovation and technology

AVA Devices

Flexible Inner LumensIncreased flow rates

Cross sections of AVA

• Empty Gravity – medical lumen Gravity-medical+7.5F PAC

Page 7: Edwards AVA Devices Advanced Venous Access 美商愛德華公司: Gina Chen

AVA High-FlowAVA High-Flow

• Capable of 96000 ml/hr without catheterCapable of 96000 ml/hr without catheter

• 9F Distal lumen accommodates 8F Swan-Ganz catheter9F Distal lumen accommodates 8F Swan-Ganz catheter

• Introducer valve is integral to devices backformIntroducer valve is integral to devices backform

Page 8: Edwards AVA Devices Advanced Venous Access 美商愛德華公司: Gina Chen

Flow Rate of AVA

  AVA HF   AVA 3Xi  

  Gravity 300mmHg Gravity 300mmHg

Proximal 1 6,028 ml/hr 36,900 ml/hr 9180 ml/hr 24720 ml/hr

Proximal 2 6,334 ml/hr 36,700 ml/hr 9180 ml/hr 25900 ml/hr

Distal 28,900 ml/hr 70,800 ml/hr 46800 ml/hr 88200 ml/hr

all 3 lumens     44700 ml/hr 96000 ml/hr

with PAC 22690 ml/hr 79420 ml/hr 8520 ml/hr 23700 ml/hr

Page 9: Edwards AVA Devices Advanced Venous Access 美商愛德華公司: Gina Chen

Content inside package

1. Vessel dilator 1ea

2. Guidewire with straight & J tips, 0.035” dia. × 45 cm 1ea

3. 22 gauge needle × 1.5” 1ea

4. 18 gauge catheter 2.5” over 20

gauge needle 1ea

5. 18gauge ×2.5” thin wall needle 1ea

6. 5 ml syringe 1ea

7. 4-way stopcock 1ea

8. Catheter locking contamination

shield 1ea

9. Disposable scalpel #11 blade 1ea

10. Interlink injection sites 2ea

Page 10: Edwards AVA Devices Advanced Venous Access 美商愛德華公司: Gina Chen

Indications of using AVA

• High-risk CABG (re-dos, multi-vessel)• Valve repair of replacement• Major Vascular repair/replacement• Transplants (non-kidney but AVA 3Xi only)• Trauma (ED as a rapid infusion device)• Burns

Page 11: Edwards AVA Devices Advanced Venous Access 美商愛德華公司: Gina Chen