em -ii - qb -rec edition

Upload: madhes14

Post on 14-Apr-2018

214 views

Category:

Documents


0 download

TRANSCRIPT

  • 7/29/2019 EM -II - QB -Rec Edition

    1/6

    www.Vidyarthiplus.com

    www.Vidyarthiplus.com

    Page 1

    www.Vidyarthiplus.com

    DEPARTMENT OF ELECTRICAL AND ELECTRONIC

    ENGINEERING

    EE2302 ELECTRICAL MACHINES II

    QUESTION BANK

    Short Answer Questions

    1. Calculate the distribution factor for a 36- slot, 4 -pole, single layer three phasewinding.

    2. Define voltage regulation of an alternator.3. What are the two components of field current required for the predetermination of

    regulation by MMF method ?

    4. What are the conditions to be fulfilled for connecting two alternators in parallel ?5. Define short circuit ratio of an alternator.6. Why is the field system of an alternator made as a rotor?7. Sketch salient pole and non salient pole rotors.8. What is synchronous reactance?9. Define Pitch factor.10.Calculate the distribution factor for an 18 slots, 4-pole three-phase winding.11.Draw the phasor diagram of synchronous motor working with lagging power

    factor.

    12.Sketch the V and inverted V- curve of a synchronous motor, clearly indicating theX and Y axes for each curve.

    13.State the differences in construction between squirrel cage and slip ring rotors ofan induction motor.

    14.A 3 phase, 4 pole, 50 Hz induction motor runs at a speed of 1425 rpm. Calculatethe slip and frequency of the rotor EMF.

    15.Sketch the circle diagram of a 3 phase induction motor.

  • 7/29/2019 EM -II - QB -Rec Edition

    2/6

    www.Vidyarthiplus.com

    www.Vidyarthiplus.com

    Page 2

    16.Calculate the pitch factor for a 36 slot, 4 pole winding having a coil pitch of 6slots.

    17.A 5 MVA, 10 kV, 1500 rpm, 3 phase, 50 Hz, 4 pole, star connected alternator isoperating on infinite bus bars. Determine the synchronizing power per mechanical

    degree of displacement under no-load condition. Xs = 20 %.

    18.When is a synchronous motor said to be under excited? What will be the nature ofpower factor under that condition?

    19.What is hunting in a synchronous motor?20.Under what condition, the slip in an induction machine is i) negative ii) greater

    than one?

    21.How do you reverse the direction of rotation of a 3 phase induction motor?22.

    Show the construction of a double cage rotor.

    23.How much is the line current and starting torque reduced in a 3-phase inductionmotor, when a star-delta starter is used, compared to direct on line starting?

    24.What are the four possible speeds that could be obtained in the cascaded operationof two induction motors with pole numbers, P1 and P2?

    25.Draw the phasor diagram of a single- phase capacitor start induction motor,showing the stator applied voltage and the main and auxiliary winding currents.

    Summary questions

    1.The open circuit and short circuit test readings obtained on a 3 phase, star

    connected, 1000 kVA, 2000 V , 50 Hz alternator are :

    Field Current, A 10 20 25 30 40 50

    OC terminalvoltage , V 800 1500 1760 2000 2350 2600

    SC armature

    current, A - 200 250 300 - -

    The effective armature resistance is 0.2 per phase. Draw the characteristic

    curves and estimate the full-load regulation at a power factor of 0.8 lagging bysynchronous impedance method.

    2.Derive the EMF equation of an alternator.

  • 7/29/2019 EM -II - QB -Rec Edition

    3/6

    www.Vidyarthiplus.com

    www.Vidyarthiplus.com

    Page 3

    3 What do you understand by direct and quadrature axis reactance in a salientpole alternator? Draw the phasor diagram of this alternator for a lagging

    power factor load

    4. Derive the expression for power developed in a 3 phase synchronous motor in

    terms of E, V, Zs, and .

    5. Sketch an excitation circle and a power circle of a synchronous motor and statewhat each one represents

    6. Using relevant phasor diagrams, describe the effect of changing the excitation,

    on the armature current and power factor of a synchronous motor and therebyobtain V and inverted V curves.

    7. Deduce the Equivalent circuit of 3 phase induction motors

    8. The power input to a 3 phase, 500 V, 50 Hz, 6 Pole, induction motor is 40 kW.

    The motor runs at a speed of 975 rpm. The stator losses amount to 1 kW andthe friction and windage losses amount to 2 kW. Calculate the i) slip ii) rotorcopper loss iii) hp output and iv) efficiency.

    9. Draw the Circle diagram for a 5.6 kW, 400 V, 3 phase, star connected 4 pole50 Hz slip ring induction motor which gave the following test data :

    No-load: 400 V, 6 A, 360 W : Blocked rotor : 100 V, 12 A, 720 W

    The ratio of stator to rotor turns is 2.6. The stator resistance per phase = 0.67 .

    The rotor resistance per phase = 0.185 . Calculate the full load current and

    maximum output.

    10. With neat diagrams , explain the working of any two types of starters used for

    starting 3 phase squirrel cage induction motors.11. Describe the following methods of speed control of slip ring induction motors:

    i) Using external rotor resistanceii) Slip power recovery scheme

    12. Based on double field revolving theory and using the torque speed

    characteristics, explain the operation of single- phase induction motors.

    ii) Draw the equivalent circuit of single-phase induction motor.

    13. Describe the constructional features and the operation of the following:

  • 7/29/2019 EM -II - QB -Rec Edition

    4/6

    www.Vidyarthiplus.com

    www.Vidyarthiplus.com

    Page 4

    i) Stepper motorii) Shaded pole motoriii)Hysteresis motor

    14. A 3 phase star connected synchronous motor is rated for 6600 V. For a particular

    load, the motor takes 50 A line current from the supply. The effective armatureresistance is 1.0 per phase and synchronous reactance is 20 per phase.

    Calculate (a) the power supplied to the motor and (b) induced EMF for a power

    factor of 0.8 lag.

    15. Explain why a synchronous motor is not self starting. Describe the method of

    starting the synchronous motor using damper winding.

    16. A 415 V, 29.84 kW, 50 Hz, 3 phase delta connected induction motor gave thefollowing test data:

    No load test: 415 V 21 A 1250 WBlocked rotor test: 100 V 45 A 2730 W

    Calculate the parameters of the equivalent circuit, draw the circuit and then insert

    the values. Stator resistance per phase = 0.3 .

    17. Derive the equation for torque developed by a 3 phase induction motor. Draw atypical torque-slip curve and deduce the condition for maximum torque.

    -------------------------

    18. Derive from fundamentals, the emf equation of an alternator

    19. A 3 phase, 16 pole, star connected alternator has 144 slots with 10 conductors per

    slot. The flux per pole = 0.03 Wb. The speed = 375 rpm. The coil span = 7 slots.

    Calculate the phase and line induc3ed emfs.

    20. A 3 phase, star connected alternator is rated at 1800 kVA, 11kV.The armature

    effective resistance and synchronous reactance are 1.4

    and 28

    respectively perphase. Calculate the percentage regulation for a load of 1250 kW at 0.8 p.f. lag.

    21. A 3 phase, star connected alternator supplies a load of 1000kW at a p.f. of 0.8 lag

    with a terminal voltage of 11kV. Its armature resistance is 0.4 /phase while

  • 7/29/2019 EM -II - QB -Rec Edition

    5/6

    www.Vidyarthiplus.com

    www.Vidyarthiplus.com

    Page 5

    synchronous reactance is 3/phase. Calculate the line value of emf generated and

    the regulation at this load

    22 What are the advantages of stationary armature and rotating field type of

    alternators compared to the other type? What are the two types of rotors used in

    alternators of rotating field type?

    23 Derive from fundamentals, the EMF equation of an alternator.

    24 Calculate the no-load phase and line voltage of a star connected 3-phase, 6-pole

    alternator which runs at 1200 rpm having a flux per pole of 0.1 Wb sinusoidally

    distributed. The stator of the alternator has 54 slots with 18 conductors per slot. The

    coil span is 7 slots.

    25 Discuss the nature of armature MMF in an alternator, bringing out its effect on

    field MMF at various power factors.

    26.A 25 kVA, 400 V, 3-phase, 50Hz star connected alternator gives rated current onshort circuit with a field current of 2 A. The same field current gives 200 V on

    open circuit. The effective armature resistance per phase is 1.0 . Calculate the

    full load voltage regulation at a Power Factors of i) 0.8 lag and ii) 0.8 lead.27.What are the advantages of stationary armature and rotating field type of

    alternators compared to the other type? What are the two types of rotors used in

    alternators of rotating field type?

    28.Derive from fundamentals, the EMF equation of an alternator.29.Calculate the no-load phase and line voltage of a star connected 3-phase, 6-pole

    alternator which runs at 1200 rpm having a flux per pole of 0.1 Wb sinusoidally

    distributed. The stator of the alternator has 54 slots with 18 conductors per slot.

    The coil span is 7 slots.

    30.A 25 kVA, 400 V, 3-phase, 50Hz star connected alternator gives rated current onshort circuit with a field current of 2 A. The same field current gives 200 V on

  • 7/29/2019 EM -II - QB -Rec Edition

    6/6

    www.Vidyarthiplus.com

    www.Vidyarthiplus.com

    Page 6

    open circuit. The effective armature resistance per phase is 1.0 . Calculate the

    full load voltage regulation at a Power Factors of i) 0.8 lag and ii) 0.8 lead.