evaporador russell sla57-50
TRANSCRIPT
-
Slim - TempIOM 112INSTALLATION OPERATIONAND MAINTENANCE INSTRUCTIONS
DIMENSIONS (Inches)MODEL W
16-1/220-1/2
2431-1/2
4053-1/253-1/2
D13-1/213-1/214-1/214-1/214-1/214-1/214-1/2
H4-3/44-3/44-3/44-3/44-3/44-3/46-3/4
B C6-3/46-3/46-3/46-3/46-3/46-3/46-3/4
2-1/42-1/42-1/42-1/42-1/42-1/42-1/4
E13-3/413-3/414-3/414-3/414-3/414-3/414-3/4
F G14-3/418-3/4
7/87/8
22-1/429-3/4
7/87/8
38-1/451-1/4
7/87/8
51-1/4 7/8
J7/87/87/87/87/87/87/8
K1-1/161-1/161-1/161-1/161-1/161-1/161-1/16
L N SUC. LIQ.M2-3/43-3/4
33
11-3/411-3/4
33
6-3/48-1/2
33
5-1/4
4-3/44-3/4
3/8 ODS3/8 ODS
1/2 FN1/2 FN
4-3/44-3/4
3/8 ODS1/2 ODS
1/2 FN1/2 FN
4-3/44-3/4
1/2 ODS1/2 ODS
1/2 FN1/2 FN
5-3/4 1/2 ODS 1/2 FN
DRAINWT.LBS.
1/2 OD1/2 OD
15182229374561
1/2 OD1/2 OD1/2 OD1/2 OD1/2 OD4
SLA17-10SLA17-13SLA27-17SLA27-23SLA37-30SLA47-40SLA57-50
CONNECTIONS
GENERALRECEIPT AND EXAMINATIONCarefully check all items against bill of lading to be sure everything has been received as ordered. Carefully inspect all items for dam-age and, if any is found, report it immediatley to the carrier and file damage claim with same.
INSTALLATIONLOCATION AND MOUNTINGThe SLA is designed to mount on the ceiling only. The unit should be installed so that there are no restrictions on the air inlet or outletas this will cause the refrigeration system to operate less efficiently.
Remove the unit from the carton. Using the fastner holes in the unit as a guide, locate the mounting fasteners in the ceiling of thewalk-in or reach-in cooler. Use #10 screws or 1/4 diameter bolts to secure the unit to the ceiling. The unit must be installed so as toallow drainage of condensate coming off the coil.
The National Sanitation Foundation (NSF) requires that any flush mounted unit be properly and completely sealed, with an approvedNSF sealant, between the unit and the mounting surface.
ELECTRICALSystem electrical installation should conform to all applicable codes and practices. All models will require the connection of power tothe fan motor according to the nameplate motor circuit electrical ratings.
REPLACEMENT PARTSTo order replacement parts, contact your local representative or contact the factory (800) 288-9488 for the location of the nearest HTPwholesaler. Always provide the evaporator model number, serial number, unit voltage and a complete description of the part required.
Part No. 08499042
SLA17-10SLA17-13SLA27-17SLA27-23SLA37-30SLA47-40SLA57-50
43 WATT43 WATT43 WATT43 WATT43 WATT43 WATT43 WATT
3000300030003000300030003000
102249005102249005102249005102249005102249005102249005102249005
1/41/41/41/41/41/41/4
621 CW621 CW621 CW621 CW621 CW621 CW621 CW
105849001105849001105849001105849001105849001105849001105849001
6666666
205932000205932000205932000205932000205932000205932000205932000
20997400209976002099780020996600209968002099700020997200
MODEL MOTORHPMOTOR
RPM BORE DESCRIPTIONPART
NUMBER DIA.PART
NUMBERPART
NUMBERPART
NUMBER
FAN MOTOR FAN BLADE FAN GUARD DRAIN PAN
NATIO
NAL
S AN I T
A T I O N F O UNDATIO
N
ULC US