AgendaAgendaAgendaAgendal Define of Explosion Proof

l Zone classifiedl Protection Method

l ATEX and IECex & NEMA l To be a inspector

Page 3: Explosion proof(20110909) [호환 모드] - Pneumatix · 2012-05-30 · /ice-proof. Has provisions for drainage and locking. Type 3SDust-Tight, Raintight and Sleet-/Ice-proof-For

방폭의방폭의의미의미및및목적목적방폭의방폭의의미의미및및목적목적

l 방폭이란?– 폭발방지의줄임말.– 기본개념 / 가연성물질은적당한농도에서점화원을만나면폭발하게되는데, 이중전기기기및전기설비가점화원이되지못하도록하는것

Page 4: Explosion proof(20110909) [호환 모드] - Pneumatix · 2012-05-30 · /ice-proof. Has provisions for drainage and locking. Type 3SDust-Tight, Raintight and Sleet-/Ice-proof-For

방폭의방폭의의미의미및및목적목적방폭의방폭의의미의미및및목적목적

l Primary explosion protection- Preventing the existence of hazardous area( 위험지역의존재예방)

ex) 공기제거, 발화제교체및밀도조정.l Secondary explosion protection

- Preventing an explosion in a hazardous area.(위험지역에서의폭발예방)

ex) 폭발가능한지역에서발화를피한다.

Page 5: Explosion proof(20110909) [호환 모드] - Pneumatix · 2012-05-30 · /ice-proof. Has provisions for drainage and locking. Type 3SDust-Tight, Raintight and Sleet-/Ice-proof-For

ATEX DirectiveATEX DirectiveATEX DirectiveATEX DirectiveDirective 1999/92/EC, ATEX 137 (user)

Directive 94/9/EC, ATEX 95 (manufacturer)

• Obligation of the employer• Directive made for health reasons and safety of the employee

Directive is applicable 1 July 2006.

• For the manufacturer• Specially to eliminate the barriers for tradeon import and export

Directive is applicable 1 July 2003.

Page 6: Explosion proof(20110909) [호환 모드] - Pneumatix · 2012-05-30 · /ice-proof. Has provisions for drainage and locking. Type 3SDust-Tight, Raintight and Sleet-/Ice-proof-For

폭발의폭발의 33요소요소폭발의폭발의 33요소요소

Page 7: Explosion proof(20110909) [호환 모드] - Pneumatix · 2012-05-30 · /ice-proof. Has provisions for drainage and locking. Type 3SDust-Tight, Raintight and Sleet-/Ice-proof-For

폭발성폭발성 Gas Gas 의의분류분류 –– IEC IEC -- GapGap폭발성폭발성 Gas Gas 의의분류분류 –– IEC IEC -- GapGapl MESG(Maximum Experimental Safe Gap) 에 의한 Gas 등급

- II A : 0.9 mm 이상- II B : 0.5~0.9 mm - II C : 0.5 mm 미만

Page 8: Explosion proof(20110909) [호환 모드] - Pneumatix · 2012-05-30 · /ice-proof. Has provisions for drainage and locking. Type 3SDust-Tight, Raintight and Sleet-/Ice-proof-For

공기의공기의혼합율과혼합율과폭발관계폭발관계(LEL~UEL)(LEL~UEL)Lower Explosive Limit, Upper Explosive LimitLower Explosive Limit, Upper Explosive Limit공기의공기의혼합율과혼합율과폭발관계폭발관계(LEL~UEL)(LEL~UEL)Lower Explosive Limit, Upper Explosive LimitLower Explosive Limit, Upper Explosive Limit

l Acetylene : 1.5% ~ 100% IICl Hydrogen : 4.0% ~ 75% IICl Propane : 2.0% ~ 9.5% IIAl Ethylene : 2.7% ~ 34% IIB

Page 9: Explosion proof(20110909) [호환 모드] - Pneumatix · 2012-05-30 · /ice-proof. Has provisions for drainage and locking. Type 3SDust-Tight, Raintight and Sleet-/Ice-proof-For

폭발성폭발성 Gas Gas 의의분류분류 –– IEC IEC -- EnergyEnergy폭발성폭발성 Gas Gas 의의분류분류 –– IEC IEC -- EnergyEnergy

l Acetylene : mJ 19 IICl Hydrogen : mJ 85 IIBl Propane : mJ 260 IIAl Ethylene : mJ 19 IIC

Page 10: Explosion proof(20110909) [호환 모드] - Pneumatix · 2012-05-30 · /ice-proof. Has provisions for drainage and locking. Type 3SDust-Tight, Raintight and Sleet-/Ice-proof-For

폭발성폭발성 Gas Gas 의의분류분류 –– IEC IEC -- CurrentCurrent폭발성폭발성 Gas Gas 의의분류분류 –– IEC IEC -- CurrentCurrentl Ignition Energy에 의한 Gas 등급

- AceII A : Current > 0.8 (Ratio Methane ( 1 ) MIC)- II B : 0.45~0.8 - II C : < 0.45

Page 11: Explosion proof(20110909) [호환 모드] - Pneumatix · 2012-05-30 · /ice-proof. Has provisions for drainage and locking. Type 3SDust-Tight, Raintight and Sleet-/Ice-proof-For

대륙별대륙별사용사용 codecode대륙별대륙별사용사용 codecode

Page 12: Explosion proof(20110909) [호환 모드] - Pneumatix · 2012-05-30 · /ice-proof. Has provisions for drainage and locking. Type 3SDust-Tight, Raintight and Sleet-/Ice-proof-For

국제국제방폭방폭기준기준 --IECIEC국제국제방폭방폭기준기준 --IECIEC

l Group I – Mine ( Methane gas)- category M1- category M2

l Group II – Mine 이외의지역 ( Gas & Dust)- category 1G/1D à Zone 0,20- category 2G/2D à Zone 1,21- category 3G/3D à Zone 2,22

Page 13: Explosion proof(20110909) [호환 모드] - Pneumatix · 2012-05-30 · /ice-proof. Has provisions for drainage and locking. Type 3SDust-Tight, Raintight and Sleet-/Ice-proof-For

국제국제방폭방폭기준기준 --IECIEC국제국제방폭방폭기준기준 --IECIEC

Page 14: Explosion proof(20110909) [호환 모드] - Pneumatix · 2012-05-30 · /ice-proof. Has provisions for drainage and locking. Type 3SDust-Tight, Raintight and Sleet-/Ice-proof-For

국제국제방폭방폭기준기준 --IECIEC국제국제방폭방폭기준기준 --IECIEC

Page 15: Explosion proof(20110909) [호환 모드] - Pneumatix · 2012-05-30 · /ice-proof. Has provisions for drainage and locking. Type 3SDust-Tight, Raintight and Sleet-/Ice-proof-For

국제국제방폭방폭기준기준 –– NEC(2002)NEC(2002)국제국제방폭방폭기준기준 –– NEC(2002)NEC(2002)

l Class I (Gas)- Division 1 - Division 2

l Class II (Dust)- Division 1 - Division 2

l Class III ( Fiber)

Group A,B,C,D

Group E,F,G

Page 16: Explosion proof(20110909) [호환 모드] - Pneumatix · 2012-05-30 · /ice-proof. Has provisions for drainage and locking. Type 3SDust-Tight, Raintight and Sleet-/Ice-proof-For

국제국제방폭방폭기준기준 –– IEC vs NECIEC vs NEC국제국제방폭방폭기준기준 –– IEC vs NECIEC vs NEC

Page 17: Explosion proof(20110909) [호환 모드] - Pneumatix · 2012-05-30 · /ice-proof. Has provisions for drainage and locking. Type 3SDust-Tight, Raintight and Sleet-/Ice-proof-For

국제국제방폭방폭기준기준 –– IEC vs NECIEC vs NEC국제국제방폭방폭기준기준 –– IEC vs NECIEC vs NEC

Page 18: Explosion proof(20110909) [호환 모드] - Pneumatix · 2012-05-30 · /ice-proof. Has provisions for drainage and locking. Type 3SDust-Tight, Raintight and Sleet-/Ice-proof-For

Gas GroupGas GroupGas GroupGas Group

Page 19: Explosion proof(20110909) [호환 모드] - Pneumatix · 2012-05-30 · /ice-proof. Has provisions for drainage and locking. Type 3SDust-Tight, Raintight and Sleet-/Ice-proof-For

폭발성폭발성 Gas Gas 의의분류분류 -- NECNEC폭발성폭발성 Gas Gas 의의분류분류 -- NECNEC

Page 20: Explosion proof(20110909) [호환 모드] - Pneumatix · 2012-05-30 · /ice-proof. Has provisions for drainage and locking. Type 3SDust-Tight, Raintight and Sleet-/Ice-proof-For

TemperatureTemperatureTemperatureTemperature

Page 21: Explosion proof(20110909) [호환 모드] - Pneumatix · 2012-05-30 · /ice-proof. Has provisions for drainage and locking. Type 3SDust-Tight, Raintight and Sleet-/Ice-proof-For

방폭방폭구조구조방폭방폭구조구조

l 내압방폭 “d” ( Flameproof enclosure)

점화원이될우려가있는부분즉불꽃아아크또는과열이생길우려가있는부분을밀폐구조인용기에넣어만일외부의폭발성가스가내부로침입해서폭발을하였을때용기가그압력에견디어파손되지않고폭발한고열가스가용기의접합부틈으로부터외부로유출되는일이있어도그동안에냉각되어외부의폭발성가스에점화가파급될우려가없도록하는구조.1. Spark and arcs in Normal condition

2. 6 threads provided

Page 22: Explosion proof(20110909) [호환 모드] - Pneumatix · 2012-05-30 · /ice-proof. Has provisions for drainage and locking. Type 3SDust-Tight, Raintight and Sleet-/Ice-proof-For

방폭방폭구조구조방폭방폭구조구조

l 안전증방폭 “e” (Increased Safety )

정상적인운동중불꽃또는과열이생겨선안될부분에이러한것들의발생을방지하기위해구조와온도상승에대해특히안전도를증가시킨구조

1. Reducing Current

2. Enhanced Insulation

3. Creepage and Clearance

4. No spark & arcs in Normal Condition

5. Max. 11 Kv Concept

6. Do not self loosing conductor connection

7. Keep stability up to at least 20K for Insulation material

8. Enclosure min. IP54. IP66 & 67 has drainage

9. Cable entry min. IP54 Plastic cable gland EC certified

Page 23: Explosion proof(20110909) [호환 모드] - Pneumatix · 2012-05-30 · /ice-proof. Has provisions for drainage and locking. Type 3SDust-Tight, Raintight and Sleet-/Ice-proof-For

방폭방폭구조구조방폭방폭구조구조

l 몰딩 “m” ( Encapsulation)

전기기기나부품을주위환경의영향에충분히견디는수지로몰딩시켜그수지내부에서발생하는스파크나열에의해점화가일어나지않도록만든구조

1. EEx ma : Zone 0,1,2

2. EEx mb : Zone 1,2

Page 24: Explosion proof(20110909) [호환 모드] - Pneumatix · 2012-05-30 · /ice-proof. Has provisions for drainage and locking. Type 3SDust-Tight, Raintight and Sleet-/Ice-proof-For

방폭방폭구조구조방폭방폭구조구조

l 본질안전 “i” (Intrinsically Safety )

잠재적인폭발환경에서의점화를야기시키는정상또는비정상상태하에서전기적에너지나열적효과를제한하도록한구조

1. Low voltage & Current

2. Nominal volt : 24VDC

3. Current : less than 100mA

Page 25: Explosion proof(20110909) [호환 모드] - Pneumatix · 2012-05-30 · /ice-proof. Has provisions for drainage and locking. Type 3SDust-Tight, Raintight and Sleet-/Ice-proof-For

방폭방폭구조구조방폭방폭구조구조l 본질안전 “i” (Intrinsically Safety )

1. Simple device(Not exceed 1.2volts, 0.1amps, 25mW or 20mJ) : No need approval : Switch, LED, thermocouples

2. Complex device : Need approval by 3th party : Transmitters, Solenoid valve –Store energy

3. Barrier : Limit current by resistor, Limit voltage with zener diode

4. Keep energy level below ignition curves when fault condition

5. 1 Resistor + 2 Zener diode + 1 fuse (protect burning Zener diode)

6. Keep below 30V combination 150mA (Can reach Hydrogen gas)

7. Light Blue Coding for Terminal Blocks

Page 26: Explosion proof(20110909) [호환 모드] - Pneumatix · 2012-05-30 · /ice-proof. Has provisions for drainage and locking. Type 3SDust-Tight, Raintight and Sleet-/Ice-proof-For

방폭방폭구조구조방폭방폭구조구조

l Intrinsically Safety - Barrier1. Zener Barrier : Passive device – Grounding

2. Isolation Barrier : No need grounding : additional electronics – Has function switching Temp. measurement or 4~20mA reading

3. Remote I/O : Combining Intrinsically safe barrier + I/O – Reducing cost and cable loss – Can use Bus system

Page 27: Explosion proof(20110909) [호환 모드] - Pneumatix · 2012-05-30 · /ice-proof. Has provisions for drainage and locking. Type 3SDust-Tight, Raintight and Sleet-/Ice-proof-For

방폭방폭구조구조방폭방폭구조구조l Intrinsically Safety – NAMUR (German-DIN19234,

EN60947-5-6)1. Proximity switch with Amplifier

2. 2 wire system, 8.2V

3. Operating proximity switch 1.2mA ~ 2.1mA (Normally 1.55mA)

4. Amplifier provide 8.2V and 8mA Loop power

Page 28: Explosion proof(20110909) [호환 모드] - Pneumatix · 2012-05-30 · /ice-proof. Has provisions for drainage and locking. Type 3SDust-Tight, Raintight and Sleet-/Ice-proof-For

방폭방폭구조구조방폭방폭구조구조

l 유입방폭 “o” (Immersion )

스위치기어나트랜스포머에사용되는기술로위험의원인이될수있는장비를무기질의 Oil에잠기게함으로써폭발가능한환경을제거하도록한구조.

Page 29: Explosion proof(20110909) [호환 모드] - Pneumatix · 2012-05-30 · /ice-proof. Has provisions for drainage and locking. Type 3SDust-Tight, Raintight and Sleet-/Ice-proof-For

방폭방폭구조구조방폭방폭구조구조

l 압력방폭 “P” (Pressusrised Enclosure)

점화의원인이될우려가있는부분을용기내에넣고보호기체를용기내부에주입하여내부의압력을유지하여폭발성가스가침입하지않도록한구조.

P1>P2 이면외부의폭발성가스가침입할수없다.

P1

P2

Page 30: Explosion proof(20110909) [호환 모드] - Pneumatix · 2012-05-30 · /ice-proof. Has provisions for drainage and locking. Type 3SDust-Tight, Raintight and Sleet-/Ice-proof-For

방폭방폭구조구조 (Zone 2 apparatus)(Zone 2 apparatus)방폭방폭구조구조 (Zone 2 apparatus)(Zone 2 apparatus)

l 비점화방폭 “n” (Non-sparking enclosure)l No need certified by 3th party• nC : Hermetically sealed, Enclosed-Break, Non-incentive

deviceFree internal volume ≤20 cm³ The encapsulation must permit a permanent temperature of ≥10 K compared to the maximum operating temperature The combination of the parts is tightly sealed or The design of the contacts will extinguish any incipient flame Limited to AC 254 V and 16 A. L and C are part of the test. Explosion hazard subgroups II A, II B and II C are to be treated differentlyl nL(Energy Limited) : Similar to intrinsic safetyl nR(Restricted-breathing enclosure) : Keep 3mbar & IP54

min. Inside of enclosure not exceed outside Temp. over 10Kl nP(Simplified pressurization)

Page 31: Explosion proof(20110909) [호환 모드] - Pneumatix · 2012-05-30 · /ice-proof. Has provisions for drainage and locking. Type 3SDust-Tight, Raintight and Sleet-/Ice-proof-For

참고참고사항사항참고참고사항사항

l 일반적으로현장에서는내압방폭 “d” 와본질안전방폭 “ I” 를 사용.

l 본질안전방폭의이점.-최소비용.( SOV 자체는비싸지만 plant 전체적으로는저렴해진다.)

-전원 “ON” 상태에서도보수가가능하다.-낮은전압과전류값으로인해작업자가안전하다.

Page 32: Explosion proof(20110909) [호환 모드] - Pneumatix · 2012-05-30 · /ice-proof. Has provisions for drainage and locking. Type 3SDust-Tight, Raintight and Sleet-/Ice-proof-For

방폭방폭구조구조별별 Cover rangeCover range방폭방폭구조구조별별 Cover rangeCover range

Page 33: Explosion proof(20110909) [호환 모드] - Pneumatix · 2012-05-30 · /ice-proof. Has provisions for drainage and locking. Type 3SDust-Tight, Raintight and Sleet-/Ice-proof-For

PROTECTION PROTECTION -- IP codeIP codePROTECTION PROTECTION -- IP codeIP code

Page 34: Explosion proof(20110909) [호환 모드] - Pneumatix · 2012-05-30 · /ice-proof. Has provisions for drainage and locking. Type 3SDust-Tight, Raintight and Sleet-/Ice-proof-For

PROTECTION PROTECTION -- NEMA standrdNEMA standrdPROTECTION PROTECTION -- NEMA standrdNEMA standrdNEMA TYPE ENCLOSURE TYPE

Type 1 General Purpose - For indoor use where oil, dust or water is not a problem. Primarily intended to prevent accidental contact by personnel with the enclosed equipment.

Type 2 Drip-proof/Drip-Tight - Similar to Type 1 with drip shields added to protect the enclosed equipment against falling noncorrosive liquids and dirt.

Type 3 Dust-Tight, Raintight, and Sleet-/Ice-Resistant - For outdoor use protects against windblown dust and water no dust - and snowproof. Has provisions for watertight connection in conduit entrance and provisions for locking.

Type 3R Rain-Resistant and Sleet-Ice/-Resistant - For outdoor use. Protects against rain, prevents entrance of rain at a level higher than lowest live part. Not dust-, snow-, or sleet-/ice-proof. Has provisions for drainage and locking.

Type 3S Dust-Tight, Raintight and Sleet-/Ice-proof - For outdoor use. Protects against windblown dust and water, permits operation when enclosure is covered by external ice, does not protect equipment from internal icing. Has provisions for locking and watertight connections at conduit entrance.

Type 4 Watertight and Dust-Tight - For indoor and outdoor use. Protects against water splash, water seepage, water from hoses, and severe external condensation. In sleet-resistant but not sleet-proof.

Type 4X Watertight, Dust-Tight, and Corrosion-Resistant - Has same provisions as Type 4 enclosures ; in addition, is corrosion-resistant.

Type 5 Type 5 enclosures are deleted ; superseded by Type 12 for control apparatus.

Type 6 Submersible, Watertight, Dust-Tight, and Sleet-/Ice-Resistant - For indoor and outdoor use where occasional submersion is encountered. Protects against static head of 6 feet of water for 30 minutes, dust, splashing or external condensation of noncorrosive liquids, water, lint, and seepage.

Type 7 Hazardous Areas (Groups A-B-C-D) - For indoor Class I locations containing hazardous gases or vapor ; air-break contacts.

Type 8 Hazardous Areas (Groups A-B-C-D) - For indoor Class I location containing hazardous gases or vapor ; oil-immersed contacts.

Type 9 Hazardous Areas (Group E-F-G) - For Class II locations containing hazardous dusts. Prevents entrance of explosive amounts of hazardous dust.

Type 10 Bureau of Mines - Designed to meet requirements of U.S. Bureau of Mines ; suitable for application in coal mines.

Type 11 Corrosion-Resistant and Drip-proof - For indoor use. Protects against dripping, seepage, external condensation of corrosive liquids, and corrosive effects of fumes and gases by providing for immersion of equipment in oil.

Type 12 Industrial - Dust-Tight and Drip-Tight - For indoor use. Protects against fibers, lint, dust, and dirt and light splashing, dripping, and external condensation of noncorrosive liquids. Has no holes, conduit knockouts, or openings, except when provision is made for oil-tight or dust-tight mechanisms with oil-resistant gaskets. (Type-13)

Page 35: Explosion proof(20110909) [호환 모드] - Pneumatix · 2012-05-30 · /ice-proof. Has provisions for drainage and locking. Type 3SDust-Tight, Raintight and Sleet-/Ice-proof-For

NEMA standard vs IP codeNEMA standard vs IP codeNEMA standard vs IP codeNEMA standard vs IP code

NEMA standard Enclosure Classification Designation

1 IP10

2 IP11

3 IP54

3R IP14

3S IP54

4 and 4X IP65

5 IP52

6 IP67

Page 36: Explosion proof(20110909) [호환 모드] - Pneumatix · 2012-05-30 · /ice-proof. Has provisions for drainage and locking. Type 3SDust-Tight, Raintight and Sleet-/Ice-proof-For

ATEX MarkingATEX MarkingATEX MarkingATEX Marking

Page 37: Explosion proof(20110909) [호환 모드] - Pneumatix · 2012-05-30 · /ice-proof. Has provisions for drainage and locking. Type 3SDust-Tight, Raintight and Sleet-/Ice-proof-For

Example Example Example Example

Page 38: Explosion proof(20110909) [호환 모드] - Pneumatix · 2012-05-30 · /ice-proof. Has provisions for drainage and locking. Type 3SDust-Tight, Raintight and Sleet-/Ice-proof-For

InspectionInspectionInspectionInspectionApparatus EEx d EEx e EEx NAppropriate Area Classification X X XGas Group X X XTemp. Class X X XEnclosure gaskets X XElectrical Connection tightness X XElectrical insulation clean & dry X XEnclosed break hermetically sealed undamaged XBreathing enclosure X

Page 39: Explosion proof(20110909) [호환 모드] - Pneumatix · 2012-05-30 · /ice-proof. Has provisions for drainage and locking. Type 3SDust-Tight, Raintight and Sleet-/Ice-proof-For

Certification codeCertification codeCertification codeCertification code

l Class I, Group A,B,C and D; Class II, Group E, F and GClass IIIType 3, 3S, 4, 4X, 6 or 6P

CSA certification codeCSA certification code

ATEX certification codeATEX certification codel Ex d II C T6 IP65