flat top block presentation 18.05.13

14
SUSTAINABILITY PRESENTATION

Upload: carraroe

Post on 12-Nov-2014

391 views

Category:

Business


1 download

DESCRIPTION

 

TRANSCRIPT

Page 1: Flat Top Block Presentation 18.05.13

SUSTAINABILITY PRESENTATION

Page 2: Flat Top Block Presentation 18.05.13

DESIGN OVERVIEW

• Maximise Site• Existing balconies and access decks• New access deck and balcony structure • Retain as much of the fabric as possible • Use sustainable materials

Page 3: Flat Top Block Presentation 18.05.13

SITE

• Maximise site• Sedum roof• Planting• Bike store• Solar Panels

Page 4: Flat Top Block Presentation 18.05.13

CARBON EMISSIONS & ENERGY USE

EXISTING BER PROPOSED BER

A2

E1

Page 5: Flat Top Block Presentation 18.05.13

SUSTAINABLE COMMUNITY

• Community Space• Enclosed site• Communal garden • Play ground• Apartment mix

Page 6: Flat Top Block Presentation 18.05.13

HEALTH & WELLBEING

• Tenants retain location • Apartment size increased• Balcony size increased• Part M compliance• Communal gardens/

playground • Fuel poverty • VOC• Daylighting • Minimise LTB, Eliminate

mould

Page 8: Flat Top Block Presentation 18.05.13

U VALUES

Page 9: Flat Top Block Presentation 18.05.13

LINEAR THERMAL BRIDGELocation of Junction Reference

L2D l x U Wall/ Floor 1 l x U Wall/ Floor 2 Ψ Note

U factor l m L2D U l l x U U l l x U L2D- (l1 x U1+ l1 x U1)

Ground Floor/ External Wall 1 0.1099 5 0.5495 0.1314 1 0.1314 0.0956 4 0.3824 0.0357

External Wall/ GF Ceiling &FF Floor 2 0.0783 4 0.3132 0.1314 1 0.1314 0.1314 1 0.1314 0.0252divided by 2

Timber Prefab Panel Party Wall/ External Wall 3 0.0768 4 0.3072 0.1314 1 0.1314 0.1314 1 0.1314 0.0222divided by 2

Timber Prefab Panel Lintels 4 0.114 1.176 0.134064 0.1314 1 0.1314 0 0.0027

Timber Prefab Panel Sill 5 0.1145 1.206 0.138087 0.1314 1 0.1314 0.0067

Timber Prefab Panel Jamb 6 0.114 1.176 0.134064 0.1314 1 0.1314 0.0027

Ground Threshold 7 0.1251 4.261 0.533051 0 0.0956 4 0.3824 0.1507

Timber Prefab Panel Gable Corner 8 0.1282 3.285 0.421137 0.0967 2.265 0.219026 0.1314 1 0.1314 0.0707

Existing Gable Wall/ Ground 9 0.1415 6.284 0.889186 0.0967 2.265 0.219026 0.0956 4 0.3824 0.2878

Ground Gable Ceiling 10 0.0709 6.6 0.46794 0.0967 2.265 0.219026 0.0967 2.265 0.219026 0.0149divided by 2

First Floor Ceiling 11 0.0719 5.619 0.404006 0.1314 1 0.1314 0.0991 2.235 0.221489 0.0256divided by 2

Existing Cavity Wall/ Party Wall 12 0.0751 6.445 0.48402 0.0991 2.235 0.221489 0.0991 2.235 0.221489 0.0205divided by 2

Existing Cavity Wall Lintels 13 0.089 2.616 0.232824 0.0991 2.235 0.221489 0.0113

Existing Cavity Wall Jambs 14 0.089 2.616 0.232824 0.0991 2.235 0.221489 0.0113

Existing Cavity Wall Sill 15 0.0862 2.659 0.229206 0.0991 2.235 0.221489 0.0077

Balcony Door/ Slab 16 0.0246 2.497 0.061426 0.0307divided by 2

Page 10: Flat Top Block Presentation 18.05.13

CONDENSATION RISK

TSI Te TI fRsi

19.5 0 20 0.9819.8 0 20 0.9919.8 0 20 0.9919.7 0 20 0.9919.8 0 20 0.9919.7 0 20 0.9918.1 0 20 0.9119.5 0 20 0.9818.2 0 20 0.9119.8 0 20 0.9919.8 0 20 0.9919.8 0 20 0.9919.7 0 20 0.9919.7 0 20 0.9919.8 0 20 0.9919.8 0 20 0.99

TEMPERATURE FACTOR

FRsi= (Tsi-Te)/(Ti-Te)=(or greater than FCRsi)0.75

Ground Floor/ External Wall

External Wall/ GF Ceiling &FF Floor

Timber Prefab Panel Party Wall/ External Wall

Timber Prefab Panel Lintels

Timber Prefab Panel Sill

Timber Prefab Panel Jamb

Ground Threshold

Timber Prefab Panel Gable Corner

Existing Gable Wall/ Ground

Ground Gable Ceiling

First Floor Ceiling

Existing Cavity Wall/ Party Wall

Existing Cavity Wall Lintels

Existing Cavity Wall Jambs

Existing Cavity Wall Sill

Balcony Door/ Slab

LTB LOCATION

Page 11: Flat Top Block Presentation 18.05.13

EXISTING BUILDING EMBODIED CARBON

Page 12: Flat Top Block Presentation 18.05.13

SYSTEMS

Page 13: Flat Top Block Presentation 18.05.13

BREEAM

FLAT TOP BLOCK

Page 14: Flat Top Block Presentation 18.05.13